The main boiler system includes portion of feed water pipes, Economizer, Steam
drum (Half level) lower Ring header, water walls, down comer and connecting
pipes of boiler side.
DOCUMENT NO: AEPL/CC:027/09 Page 38 of 42
ARUCHEM
TECHNICAL SPECIFICATION FOR 4 x 600 MW
600 MW UNIT CHEMICAL CLEANING STERLITE ENERGYLTD,
JHARSUGUDA-Orissa
Boiler circulating water pump shall be used for re- circulation during
chemical cleaning.
3.3 Cleaning water capacity (Approx)
Description Water capacity
(M3) Approx
1. ALKALI FLUSHING FRONT SYSTEM
HP/LP Condenser Hot well Low level 600
Deaerator (Feed Storage tank) 200
HP heaters 30
LP heaters 50
Pipes of condensate & feed water 90
Total Alkali cleaning Volume 970 M3
2. ACID CLEANING OF BOILER
Economizer , Header and piping 200
Water wall tubes, Header , down 120
comers and risers
Steam Drum ½ level 35
Temporary pipes and cleaning tanks 20
Total Alkali cleaning Volume 375 M3
• The temporary pipes for acid cleaning inlet, outlet and drain pipes
should adopt mild steel tubes of φ219×6mm.
• The outlet pipes connect from the bottom lower ring header stubs
(100 mm). (Each one tapping from each corner side). All the
tapping connects to the common header φ219×6 mm mild steel
tubes.
• The boiler circulating water pump (CC Pump) will be used during
acid cleaning for intermediate circulation.
• The (2)two acid cleaning pumps (with one stand by) out side
cleaning tank are set parallel, make a recirculation loop with φ
219× 6 mm pipes.
• The tank drain pipe of φ108 is installed at the bottom of the tank.
• The auxiliary steam supply temporary pipes φ108×4 mm pipes and
connect to the mixing tank. The insulation should be done . Set 2-3
draining points. The parameter of steam should meet the following
requirements: Pressure is 0.8 – 1.0 MPa, temperature is 250 – 300 oC
and flow is 15 – 20 t/h.
• Acid transfer pump shall be used for transferring acid from tanker in
to mixing tank. Pump gland packing shall be PTFE materials.
• Ensure the temporary pipe should not have any debris before
erection.
• Don't install water lever gauge in drum. Use PVC transparent hose
pipe at back nozzle of water level gauge valves as temporary level
gauge.
• Connect air vent pipe from steam drum φ50 pipe for nitrogen filling
and hydrogen exhausting.
• All the valves of temporary system shall have number and Tag
nameplates. Check that all the valves are easy to operate and
reliable. The valves contacted with acid liquor should be wrapped
with plastic membrane.
• Ensure availability of illumination at boiler, fire tender and
ambulance during chemical cleaning.
• The access doors, fire observing opening, air dampers, air ducts,
and flues of boiler shall be closed.
• Fill DM water to hot well of condenser until reach the highest level.
Start condensate pump.
• Ensure flushing flow rate should be ≥ 600t/h until the water become
clean.
• While carryout water flushing, initially flush by pass circuit of HP
heaters and LP heaters, after water is clean; flush main parts of HP
heater and LP heater.
• Clear the strainer after completing water flushing.
The chemical using for alkali cleaning is 0.05 ~ 0.1 % Non Ionic Detergent
and 0.2~ 0.3 % of Tri-Sodium phosphate. The temperature should be
maintained at 55 ~ 60 o C.
Completion criteria: Ensure the out let drain water pH ≥ 7.5 and the water
should be clear without any sundries.
• DM Water flushing
• Alkali cleaning
• Water flushing after alkali cleaning
• Hydrochloric acid cleaning
• Water flushing after acid cleaning
• Citric acid rinsing
• Neutralization
• Passivation
5.2.3: Super Heater Filling & DM Water Flushing (Cold & Hot)
Fill the super heater and flush till drain water is clear, Prepare protecting
liquor of 250 PPM of hydrazine hydrate and ammonia pH 9.5~ 10. Fill the
solution to super heater. After achieving pH and hydrazine at overflow
lines through saturation steam tubes connected to steam drum (Water
sample to be collected inside the steam drum) stop filling the system.
Keep tube samples inside the steam drum; close both side steam drum
manholes.
Fill boiler with DM water to flush boiler till water is clear, check the water
quality and ensure the accepted level. Raise the temperature 70~75 Deg
C by using auxiliary steam. Circulate the hot water 4~6 hrs. Check the
water quality.
After completion of chemical dosing, start one Boiler circulating pump for
10~15 minutes for intermediate circulation. The same process continued
every one hour (Circulation & Choking technique). Check periodically
alkalinity, Phosphate at every 30 mints.
After complete draining of alkali solution, fill the boiler with DM water and
flush until the draining water pH ≤7.5.
Fill the boiler with DM water and raise the temperature 55~60 Deg C. add
the following chemicals one by one.
Drain the Mixing tank and fill with DM water. Open the air vent pipes of
drum and startup cleaning pump to fill water into boiler, carry out rinsing
the system till getting normal water pH 4.0 and total Fe ≤ 50 Mg/l. The
system draining is carried out under nitrogen capping in every step
starting from acid pickling up to DM rinsing.
DOCUMENT NO: AEPL/CC:027/09 Page 38 of 42
ARUCHEM
TECHNICAL SPECIFICATION FOR 4 x 600 MW
600 MW UNIT CHEMICAL CLEANING STERLITE ENERGYLTD,
JHARSUGUDA-Orissa
Citric Acid is charged into the system to obtain the concentration of 0.2 %
and the pH maintained between 3.5~4.0, by the addition of Ammonia.
The temperature shall be maintained during this process at 55~600 C.
Boiler water circulating pump should operate for 10 mints one by one.
Circulation is to be maintained for 3~4 hours. Check the inlet and outlet
sample pH and total Iron at regular intervals. Once achieved the constant
value of Iron at out let, start drain the complete system under nitrogen
capping.
Fill the Boiler system with DM water and establish circulation for ½ an hour.
Measure the iron in the inlet and return line. Drain the system under
nitrogen capping.
Again fill the Boiler system with DM water and establish circulation for 1~2
hour. Measure the iron in the inlet and out let line. The DM Rinse Operation
continued till the Iron values drop down 25 PPM. Drain the system under
nitrogen capping.
5.2.12. Neutralisation
DM Water is filled in the boiler system and the raise the temperature
80~850 C and then 0.5~1.0 % of Sodium Carbonate is inject into the boiler
through chemical circulation pump. Establish circulation through boiler
water circulating pump should operate for 30 mints one by one. All
Instrumentation tapping are flushed and venting of the system carried out
several times to get rid of Hydrogen. Keep circulation for 4 Hrs. Check the
pH values periodically; finally the entire system is drained under
atmospheric pressure.
5.2.13. Passivation:
Fill the boiler system with DM water and establish circulation. Raise the
temperature of solution up to 80-90ºC by addition of steam, add
hydrazine hydrate to get the concentration of 300~350 ppm and add
ammonia solution to raise the pH up to 9.5~10.0. Boiler water circulating
pump should be started for 30min one by one, circulation continued for
20 hours. Measure the Hydrazine concentration and pH periodically.
During passivation, the water level should be a little higher than the level
of rinsing. After complete passivation, quickly drain the passivation
solution under atmospheric pressure. The Spent solution shall be oxidised
by using Bleaching Powder.
After completion of draing, the steam drum manhole shall be opened for
natural cooling. If found any loose debris, it shall be removed manually
with cotton cloth.
Discharge hydrochloric acid waste liquor into treating pool of waste liquor
and neutralize with alkali cleaning waste liquor. Then use proper NaOH
liquor and lime powder to neutralize. The pH of wasting liquor should be at
the range of 6.0~9.0, then discharge after static.
The citric acid in passivating waste liquor could be oxidized with sodium
hypochlorite. Because phosphate is unharmful substance, so add a little
acid to neutralize ammonia to make the pH at the range of 6 ~ 9.
6.4 Discharge quality of the waste Water:
pH 6~9
COD 150 mg/l
Harmful Substance Maximum allowable discharge consistency
pH 6~9
suspend substance 150 mg/l
COD 150 mg/l
7.1 Check alkali cleaning effect with eye observation, there shall not be
oil dirty on the Inside walls of equipment.
• SH Air vent lines, Nitrogen capping lines are properly tagged and
taken in to suitable location for easy operation
• Proper neutralizing arrangement is available at site to Neutralize
and dispose off the effluent in line with local pollution control
board norms.
DOCUMENT NO: AEPL/CC:027/09 Page 38 of 42
ARUCHEM
TECHNICAL SPECIFICATION FOR 4 x 600 MW
600 MW UNIT CHEMICAL CLEANING STERLITE ENERGYLTD,
JHARSUGUDA-Orissa
• All the test team members should be well conversant with the
emergency operating instructions
• If an Eye wash bottle is used the jet should not be directed at the
front of the eye. It should be directed in from the side, so that flow
is over the surface of the eye.
• Ensure that one fire tender with operators and ambulance will be
kept ready in round the clock operation during chemical cleaning
operation in case of any emergency.
Temperature 30 55±5
Temperature 60 70±5
****************
1. M.S. TANK
1 Circulation Tank 20 M3 01 No
7. Elbows
1. Ø 10” Inch 90 Deg 2 Nos
2. Ø 8” Inch 90 Deg 30 Nos
3. Ø 6” Inch 90 Deg 30 Nos
4. Ø 4” Inch 90 Deg 50 Nos
5. Ø 3”Inch 90 Deg 25 Nos
6. Ø 2” Inch 90 Deg 50 Nos
7. Ø 1” Inch 90 Deg 20 Nos
1. INHIBITOR EVALUATION
INHIBITOR:
W1 - W2
----------- mg./sq.cm.
A
• Efficiency of the inhibitor is evaluated as follows:
• Repeat the procedure with two weighed coupons under similar
conditions of acid strength, temperature and time.
• One pre-weighed coupon should be immersed in uninhibited acid
for 60 minutes.
• The other pre-weighed coupon should be immersed in inhibited
acid for 60 minutes.
Efficiency = X-Y
------ x 100%
X
DOCUMENT NO: AEPL/CC:027/09 Page 38 of 42
ARUCHEM
TECHNICAL SPECIFICATION FOR 4 x 600 MW
600 MW UNIT CHEMICAL CLEANING STERLITE ENERGYLTD,
JHARSUGUDA-Orissa
= T.V. x 0.365
5. DETERMINATION OF IRON
Required reagents:
1. 0.01 M EDTA
2. Chloroacetic acid 10%
3. Sodium Acetate 10%
4. Sulphosalicyclic Acid 20%
5. Potassium Per-sulphate
Procedure:
• Take 10ml. of aliquot in a clean Erlenmeyer flask.
• Add 5 to 10 drops of 10% chloroacetic acid solution.
• Add 5 to 10 drops of 10% sodium acetate solution.
• Add 5 drops of 20% sulphosalicyclic acid.
• Add pinch of potasium persulphate
• Titrate against 0.01M EDTA
• End point is red to pale yellow colour.
Calculation:
Required reagents:
1. 1 N NaOH solution
2. Phenolphthalein Indicator or Thymol Blue Indicator
Procedure:
• Take 10ml. of sample in a clean conical flask
• Add 50 ml. of DM water.
• Add 3-5 drops of indicator
• Titrate it against 1N NaOH solution
• The end point is colourless to pink or blue
Calculation:
% of Citric Acid = T.V. x 1N x 70 x 100
-------------------------
100 x 1000
= T.V. x 0.70
% of Citric Acid = T.V. x 1N x 64 x 100
Monohydrate ----------------------------
100 x 1000
= T.V. x 0.64
7. DETERMINATION OF HYDRAZINE
Required Reagents:
1. 0.1N Potassium Bromate - Potassium Bromide
2. 1:1 or Con.HCl
3. Methyl orange
Procedure:
• Take 10 ml. of sample in a clean conical flask
• Add 50 ml. of distilled water.
• Add 10 ml. of conc.HCl. Mix well.
• Add 3 drops of Methyl Orange.
• Titrate it against 0.1N KBrO3 solution until yellow colour from
red.
Calculation:
N2H4 ppm = T.V. x 0.1 x 8 x 1000
--------------------------
V
Where TV = Titre volume
V = Volume of aliquot taken
DATE:
PROJECT :
UNIT :
PROCESS : Detergent Flushing/ Hot Water Flushing;
I. ADDITION OF CHEMICALS:
DATE:
PROJECT :
UNIT :
PROCESS :
ANALYTICAL DATA:
DATE:
PROJECT :
UNIT :
PROCESS : ACID CLEANING
I. ADDITION OF CHEMICALS:
DATE:
PROJECT :
UNIT :
ACTIVITY : CITRIC ACID RINSE
I. ADDITION OF CHEMICALS:
DATE:
PROJECT :
UNIT :
ACTIVITY : PASSIVATION.