Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Plan Repérage

S4
12 1477

1477
772
S1

0
772 705

Pr-1222 Pr-1222 4 *Ø 18
PL10*50 PL10*50
Pr-1038 4 *Ø 18
IPE220

40

S2
105

S5
105

208
6 *Ø 22

50
Pr-1320 Pr-1194
PL12*140 PL10*193

4 *Ø 18

518 49 910
0

518

567

1477
1489

FRONT VIEW
S3 Scale 1:5

1477
772
0

772 705

4 *Ø 18 Pr-1194 Pr-1222
Pr-1320
PL12*140 PL10*193 PL10*50 4 *Ø 18
Pr-1038
IPE220
35

29 29
35

3D VIEW
Scale 1:5

6 *Ø 22
2 *Ø 18 Pr-1222
PL10*50
2 *Ø 18

TOP VIEW
Scale 1:5

ASSEMBLY MARK: BM001 - UNITS: 1 Weight= 45.1 Kg


Pr-1038 1 IPE220 x 1477 mm. S275JR 37.3

Pr-1194 1 PL10*193 x 294 mm. S275JR 2.6

Pr-1222 2 PL10*50 x 198 mm. S275JR 1.5


GENERAL NOTES Pr-1320 1 PL12*140 x 285 mm. S275JR 3.8

1.- ALL DIMENSIONS ARE IN MILLIMETERS. UNLESS INDICATED OTHERWISE. Pos. Qty. Denomination Material Standard Weight
2.- BEFORE WELDING PREHEAT THE EXCEEDING 25 mm THICK PARTS PROPERLY.
WEIGHT (KG.)
3.- ALL DIMENSIONS GIVEN IN THE LIST OF MATERIALS, ARE JUST FOR GUIDANCE. THIS DRAWING IS PROPERTY OF PHB WESERHÜTTE S. A.
THE DIMENSIONS GIVEN AT THE DRAWING, MUST ALWAYS PREVAIL. REPRODUCTION AND DIVULGATION FORBIDDEN 45.1
4.- ALL STEELS FOR SHAFTS C45E (F-114), 34CrMo4 (F-125), ETC. HAVE WHITHOUT WRITTEN PERMISSION.
001603-02-0TT-EM-1100-BM001_00 SCALE
TO BE SUPPLIED WITH NORMALIZED HEAT TREATMENT.
STEEL STRUCTURE UP TO 12m LENGTH SHALL BE IN SINGLE PIECE WITHOUT ANY BUTT WELD JOINT. DRAWN 29/05/2020 M.A.V 1:5
ABOVE 12m LENGTH , "Z" BUTT WELD BY FULL PENETRATION BUTT WELDS AND GROUND FINISH, WITH SPLICE PLATE IS ALLOWED. CHECKED 29/05/2020 J. Diaz
TOLERANCES FOR LINEAR DIMENSIONS
DIN A1 594x841

SPLICING FOR BEAMS SHOULD BE DONE NEAR THE ONE-THIRD POINT OF THE BEAM SPAN (UNO). BATTEN PLATES AND LACING (UNLESS OTHERWISE SPECIFIED)
APPROVED 29/05/2020
J. L. Moral
FOR BUILT-UP SECTIONS SHALL BE WELDED. REF. PROJECT REF. CLIENT
OVER 1 5 30 120 400 1000 2000 >4000
BUTT WELD OF STEEL STRUCTURE SHALL BE "RT" TESTED BEFORE INSTALLATION OF SPLICE PLATE. JESA-Jrof DAP/TSP 001603
UP TO 5 30 120 400 1000 2000 4000

MECHANICAL 0.1 0.2 0.3 0.5 0.8 1.2 2 3 DRAWING NUMBER PHB SHEET
TT-02
STRUCTURAL 0.3 0.5 0.8 1.2 2 3 4 * 29-05-20 M.A.V FOR ISSUED 00 001603-02-0TT-EM-1100-BM001
ASSEMBLY MARK: BM001 CLIENT NUMBER REV.
* STANDARD ISO 13920 CLASS "A" WILL BE USED FOR DIMENSIONS LONGER
THAN 4000 mm IN WELDED STRUCTURES OR STRUCTURAL ASSEMBLIES DATE NAME MODIFICATION REV. 00

You might also like