CONTROLLER 6000

Gallagher
Controller 6000
The Gallagher Controller 6000 is a powerful and intelligent modular
field controller capable of processing, storing and communicating large
amounts of data independently of the Gallagher Command Centre Server
in real time.

Controller 6000 configuration. Peer to peer relationships connected to the Gallagher Controller
The Gallagher Controller 6000 is a core can be configured directly between 6000 to allow HBUS devices to be star-
component of the Gallagher platform Gallagher Controllers. For example, inputs wired back to a secure Controller
for integration. It provides distributed on one Controller can be monitored and Cabinet.
intelligence in the field to manage access controlled by another Controller.
control and security functions. In addition, Gallagher Reader Modules
it has the ability to physically enforce The modular design of the Gallagher The Gallagher 8R Module is capable of
business rules, monitor its environment, Controller 6000 provides a cost-effective supporting up to eight Gallagher
communicate with other integrated approach to engineering a Gallagher readers or four Wiegand readers. The
systems and make enriched access system. Up to ten doors can be controlled Gallagher 4R Module is capable of
decisions based on variables from these with the Controller 6000 when paired supporting up to four Gallagher readers or
systems. with module choices available to cater two Wiegand eaders.
for a wider range of site requirements. I/O
The Gallagher Controller 6000 is one functionality is provided via the Controller Monitoring Inputs and
of the key integrated components of a Reader Modules. Other expansion options Controlling Outputs
Gallagher security system. are also available. Gallagher H and R Series Modules have
on-board inputs and outputs, that can
Gallagher Controller 6000 The Gallagher Controller 6000 be used for door monitoring and control,
variants and Reader Module architecture supports the Gallagher or for general I/O functions. Gallagher
hardware: Remote Arming Terminal for intruder H and R Series Modules monitor and
> Gallagher Controller 6000 alarms and the Gallagher Perimeter report the state of balanced inputs, and
> Gallagher Controller 6000 High Security Fence Controller and Keypad for enforce decisions to switch output relays,
Spec (HS) integrated perimeter security. if required.
> Gallagher 8H Module

> Gallagher 4H Module Gallagher HBUS compatibility Gallagher 8H and 8R Modules have 24
> Gallagher 8R Module The Gallagher Controller 6000 supports balanced inputs and eight relay outputs
> Gallagher 4R Module the following HBUS devices: on-board. Gallagher 4H and 4R Modules
> Gallagher T Series Readers (Rev 1) have 12 balanced inputs and four
The Gallagher Controller 6000 features > Gallagher F22 Fence Controller. relay outputs on-board. (Additional I/O
straightforward system architecture expansion options are also available if
providing powerful and flexible Gallagher 8H and 4H Modules can be required).

security.gallagher.co
Gallagher
Controller 6000

Four states can be monitored (using the Input/Output Expansion Options management is maintained.
default two 4k7 ohm resistors or optional The on-board number of available inputs
configurable end-of-line resistances), and outputs can be increased with Access decisions are made independently
including: the following input-output expansion of the server, based on the individual’s
options: identity, the area and time they are
> Open > Gallagher 8-Input Expansion attempting to access, as well as what
> Closed > Gallagher I/O Expansion competencies (e.g. inductions, training,
> Short Circuit (Tamper) > Gallagher High Density I/O Expansion licenses, security clearances, etc) are
> Open Circuit (Tamper) > Gallagher GBUS Universal Reader required for access to that area and
Interface (Standard or Wiegand whether or not the person holds these
The inputs on the Gallagher H and R variant) competencies.
Series Modules can be used to monitor: > Gallagher Security Fence Controller

> Access controlled doors The relevant fields of the cardholder


> Intruder detection (i.e. passive infra-red Refer to the GBUS I/O Devices datasheet database, alarm configuration and
detectors, glass break detectors) for more information. security parameters are immediately
> Monitored doors downloaded to the Controller 6000
> Equipment alarms Distributed Intelligence and automatically to allow for instant access
> Any other devices providing a clean Data Storage and alarm control decisions.
switch contact. Distributed intelligence is a significant
feature of the Gallagher system All events and alarms are date and
The on-board relays can be used for: architecture. All Gallagher field devices time stamped before being sent to the
> Access controlled doors connecting to Gallagher Controllers can Gallagher Command Centre server. Each
> Alarm outputs, e.g. to activate sirens operate independently of the Gallagher Gallagher Controller 6000 is capable of
> Control outputs, e.g. to switch on air Command Centre Server. This ensures buffering events should communications
conditioning that if the site experiences network with the Command Centre server fail. The
> Time activated outputs, e.g. to switch communications problems, full operation Gallagher Controller 6000 will transfer
on lighting. of access control and alarms the buffered events to the Command

2
Centre server automatically when The Gallagher Controller 6000 Peer-to-Peer Communications
communications are reestablished. communicates with the Gallagher The Gallagher Controller 6000 can
The provided database storage space Command Centre server via TCP/IP over communicate directly with other
supports at least 500,000 card records an Ethernet network. Each controller Gallagher Controllers without requiring
and 80,000 access control events. is factory-programmed with a unique the Gallagher Command Centre
network MAC address. The Gallagher server to be online. The peer-to-peer
Communications Controller 6000 provides a standard communications enable the controllers
The Gallagher Controller 6000 has two 10/100 BaseT connection point. The to communicate with each other over
RS485 connections. Each connection Gallagher Controller 6000HS has a LAN/WAN using TCP/IP for the
may be individually configured to support dual 10/100/1000BaseT Ethernet purposes of monitoring, back-up and
HBUS, GBUS, Sensor or AperioTM connections, to provide additional control. This significant feature provides
communications. network redundancy. extensive flexibility and efficient system
configuration. For example, a Gallagher
The HBUS protocol runs at speeds up Gallagher Command Centre can be Dialler resident on a Controller 6000
to 1Mb/s, substantially faster than most programmed to dial via PSTN to a can be configured to transmit events
other RS485 based communications Gallagher Controller 6000 in response originating from any Gallagher Controller
protocols. The communications between to configuration changes or when an to a remote alarm monitoring station.
the Gallagher Controller 6000 4R or operator initiates a request.
8R Modules and Gallagher Readers Gallagher recommends that installers
use a proprietary format (Cardax IV) A USB 2.0 port is available to allow local provide a back-up power supply to the
requiring 4-core cable. Third party readers software upgrades. Upgrades are pre- Gallagher Controller 6000 so it can
communicating via the Wiegand format authorized at the reader. continue to operate for a specified period
use a 6-core cable connection. in the event of a mains supply failure.
The USB port can also be used to The back-up power supply can also be
connect to a cellular modem for alarm monitored by connecting Gallagher power
transmission. supply alarm outputs to inputs on a

3
Gallagher Controller 6000 with either an Data Security Entry and exit delays can be configured to
H or R Module or connected field device. All data over the network between the give the cardholder time to enter or leave
Gallagher Controller 6000s (inter- the premises. Full event details, including
Software Upgrades controller) and the Gallagher Command the cardholder’s name, are recorded for
The Gallagher Controller 6000 can Centre server uses 256-bit AES arm/disarm operations at the Command
be enhanced in the future via software symmetric encryption and RSA-1024 Centre. A relay output may be used to
upgrades. These software upgrades bit communication access authentication. indicate the arm/ disarm status of a
can be implemented through Gallagher particular alarm zone.
Command Centre. The Gallagher Intruder Alarms
Controller 6000 software upgrade The Gallagher Controller 6000 Gallagher perimeter security
process does not affect door access provides sophisticated intruder alarm Fence Controller
during the download process. Upon management, making separate intruder The Gallagher Controller 6000 and
completion of the software download, alarm systems unnecessary. Intruder 6000HS can also manage up to 16
door access is momentarily affected. All detectors connect directly to the I/O Gallagher Security Fence Controllers per
HBUS devices also seamlessly upgrade devices supported by the Controller RS485 connection. Fence Controllers
to new software on a Gallagher Controller 6000 so alarms can be raised at the provide two high voltage circuit for
6000 upgrade. Gallagher Command Centre. Outputs can perimeter protection. Refer to the
trigger actions such as switching on lights Gallagher Security Fence Controller
The ability to download software over the when an intruder is detected. datasheet for more information.
network means enhancements
can be easily and quickly installed in Arming (setting) and disarming (unsetting) AperioTM Door Control
the future. A full speed USB 2.0 port of alarms can be implemented according The Gallagher Controller 6000 supports
provides the option of securely loading to a time schedule, via operator overrides, up to 16 lower security wireless
a controller’s software via USB memory by authorised cardholders at Gallagher managed doors per RS485 connection.
stick, even when the controller is not Readers, by keyswitch control, or by the A maximum of 20 doors per controller
networked. Gallagher Remote Arming Terminal. is supported. Refer to the AperioTM
datasheets for further information.
BULK SOFTWARE UPGRADES The Gallagher Remote Arming Terminal
Gallagher Command Centre allows also enables users to monitor alarms disturbance Sensor
groups of up to 10 Controller 6000s to in the field. Refer to the Gallagher Remote The Gallagher Controller 6000 supports
have their software upgraded via the bulk Arming Terminal datasheet for more up to 32 D21 Disturbance Sensors per
change process, significantly speeding up information. RS485 connection. Refer to the D21
the upgrade process for large sites. Disturbance Sensor datasheet for further
information.

4
KEY FEATURES OF THE GALLAGHER CONTROLLER HIGH SPEC AND 8H MODULE
DIP SWITCHES AUXILLIARY
RS232 PORT

controller POWER IN

PRIMARY 10/100/1000
BASET ETHERNET PORT
RS485 PORTs

SECONDARY 10/100/1000
BASET EtHERNET PORT
(6000hs only)

In service relay
(6000hs only) USB PORT

4 STATE BALaNCED
INPUTS
4-STATE BALANCED
INPUTS

POWER OUT POWER OUT

hbus device hbus device


CONNECTIONS CONNECTIONS

relay common relay common

relay outputs

hbus module POWER IN relay outputs

KEy features of the GALLAGHER 8r MODULE

4 STATE BALaNCED
INPUTS
4-STATE BALANCED
INPUTS

POWER OUT POWER OUT

READER reader
CONNECTIONS CONNECTIONS

relay common relay common

relay outputs

Reader module POWER IN relay outputs

5
Elevator Control The configuration is limited only by local time zone, relative to co-ordinated
The Gallagher Controller 6000 provides combinations of the following: Universal Time (UTC). This includes
elevator access control. Card readers > Up to 75 elevator levels per daylight savings settings.
may be installed in elevator cars to elevator shaft (low level)
provide restricted access to floors. > Up to 256 elevator levels per elevator Power Supply Required
When a Prox Plus reader is installed, the shaft (high level) * The Gallagher Controller 6000 runs on
cardholder can be prompted to enter > Up to 2 elevator shafts per Gallagher 13.6V DC+-15% allowing a standard
their PIN before access is granted. Controller 6000. battery backed 12V power supply to be
Floors may be ‘unlocked’ (i.e. the elevator Typically each elevator car requires used. The system monitors the power
floor select button enabled) on a time one card reader and one relay output for supply for power low and power high
schedule. each floor select button. If destination conditions.
reporting is required then one input is
Relay outputs on Gallagher H or R required for each floor select button in Gallagher Cabinets
Modules and Expansion Boards can be each elevator car. Two Gallagher Cabinets are available
configured to enable the elevator floor to accommodate the Gallagher
select buttons in an elevator car. Gallagher Controller API Controller 6000 and I/O Devices:
Inputs on Gallagher H or R Module Events can be sent to and received from > Gallagher Cabinet

or Gallagher I/O Interfaces can be third party systems within the Gallagher > Gallagher Dual Cabinet

configured to monitor which floor is Controller 6000 using the Gallagher


selected, providing destination reporting Controller Application Programming The Gallagher Dual Cabinet is available
and minimising the opportunity of more Interface (API). It is ideal for interfaces to with or without a power supply. Refer to
than one floor being selected. third party systems such as imaging and the Gallagher Cabinets datasheet for
duress systems. Refer to the Gallagher further information.
The flexible design of the Gallagher Controller Application Programming
Controller 6000 enables it to be Interfaces datasheet for more
configured for almost any elevator information.
control situation. Both low level (relay
to input individually wired) and high Managing Different Time Zones
level (data interface) options from the and Daylight Savings
Gallagher Controller 6000 to elevator When the system is configured, each
controllers are supported. Gallagher Controller 6000 is assigned a

* Note: Actual number depends on the type of elevator system being interfaced to.

6
Controller 6000
Cellular Alarms
Ethernet connection to Module
Gallagher Command Centre Cellular
and other Gallagher Controllers Network

LAN/WAN To remote
IP Alarms Internet monitoring station
Transmission
Gallagher
Controller
6000 To remote
monitoring station

Gallagher Dialler
Gallagher 4H or 8H Module
(plug-in optional)
12 Inputs / 4 Outputs (4H)
24 Inputs / 8 Outputs (8H)

Maximum of
20 T Series
HBUS RS485 Readers
2 RS485
AND
runs are
25 F22 Fence
available
Controllers per
Gallagher
Controller 6000

Gallagher Gallagher Gallagher Gallagher Gallagher Gallagher


T10 T11 T12 F22 Fence T10 T11 or T12
Reader Reader Reader Controller Reader Reader
GBUS
RS485

Gallagher Gallagher Gallagher Gallagher Gallagher Gallagher


Security Remote GBUS Universal High Density 8-Input I/O
Fence Arming Reader I/O Interface Expansion Expansion
Keypad Terminal Interface Interface Interface

4 8
devices devices
maximum maximum

The diagram above notes maximum LEGEND


connectivity. System configuration, Internet Protocol
network capacities, and the volume HBUS RS485
of system activity affect performance. GBUS RS485
Please contact Gallagher Technical Plug-in Connection
Support for advice.
Dial Up Connection
Cellular Signal

7
Gallagher
Remote Alarm Transmission

The Gallagher Controller 6000 allows for encryption of the transmitted data, using The GIPAR can reside on the same PC
remote alarms transmission via multiple AES 256 bit encryption, which can be as a monitoring station’s main receiver
mediums: optionally configured between the IP software, using a virtual RS-232
> LAN/WAN networks using TCP/IP Alarms Transmitter and Receiver. connection to communicate, or on a
protocol separate PC with physical RS-232 serial
> Cellular networks, via cellular modem Cellular Network Alarms Transmission connection. Alternatively, the Gallagher
> PSTN Alarms, via Gallagher Dialler Each receiver on an IP Alarms Transmitter IP Alarms Receiver may be operated in a
can be configured to communicate stand alone mode.
Gallagher IP Alarms via either a hard-wired IP link, or via a
Controller 6000 – IP Alarms Transmitter wireless, cellular network. If the ‘Wireless’ Gallagher Dialler
The Controller 6000 can be configured option is selected for an alarms receiver, The Gallagher Dialler enables remote
with a Gallagher item, the ‘IP Alarm and the appropriate cellular hardware alarms management in conjunction with
Transmitter’ via LAN/WAN networks (C300600) is connected to the Controller either the Gallagher Command Centre
or cellular networks to enable alarms 6000, the alarms will be transmitted over software, or with an alarm monitoring
transmission. An IP Alarm Transmitter is a the installed SIM card’s cellular network. company. The Dialler also enables
logical rather than physical item, providing The cellular data transmission conforms an on-demand connection between
the linkage between the Controller to the above DC-09 protocol for secure the Gallagher Command Centre and
and one, or several, remote monitoring data communication. remote Gallagher Controller 6000, for
station’s alarm receivers. configuration and security management.
Gallagher IP Alarms Receiver
Should alarms fail to be received at The Gallagher IP Alarms Receiver The Gallagher Dialler and Gallagher
the first receiver, the transmitter can (GIPAR) is an application freely available Controller 6000 can be configured to
automatically failover to the next for remote alarms monitoring stations dial via both of these methods on the
receiver, after a pre-configured number of to receive Controller 6000 IP alarms occurrence of an alarm.
attempts. signals, should their existing receiver
software not be capable of receiving the Communications
IP Alarms Transmission - Protocol and ANSI / SIA DC-09 transmission The Gallagher Dialler dials out to the
Security protocol. Gallagher Command Centre or the alarm
Alarms sent via an IP Alarms Transmitter monitoring station over telephone lines.
conform to the ANSI / SIA DC-09-2007 The GIPAR’s primary purpose is to receive Importantly, the Gallagher Dialler is able
alarm transmission protocol. The data all IP alarms from Gallagher sites for an to seize the phone line to transmit alarms,
transmitted over this protocol is the alarm monitoring station, then translate when the line is shared with a normal
same data as currently transmitted with these into serial RS-232 AdemcoTM 685 phone or other device. The peer-to-peer
Contact ID alarm transmission. The (ContactID) protocol, commonly accepted communications between Gallagher
DC-09 protocol allows for highly secure by most alarm receiver applications. Controllers enables a controller fitted

8
gallagher dialler

with a Gallagher Dialler to support Gallagher Controller reaches a pre-


off-site alarm monitoring and operate defined threshold.
as a back-up dialler for other Gallagher
Controllers on site. Configuration
Remote alarms monitoring using the
Contact ID Protocol is supported for Contact ID protocol and the dial-up
off-site alarms monitoring. The Gallagher connection to the server are set up in the
Dialler facilitates off-site monitoring by Gallagher Command Centre.
transmitting alarms to remote monitoring
stations using industry-standard Contact They can both be configured to dial
ID format. on the occurrence of an alarm. In this
scenario, dial-up to a remote alarm
Using Contact ID, the Gallagher Dialler monitoring station occurs first followed
can be configured to: up with dial-up to the server.
> Dial on the occurrence of specific

alarms or events Housing and Power


> Provide periodic test transmissions (24 Each Gallagher Dialler is mounted on top
hour test and configurable line test) of its respective Gallagher Controller,
> Dial on the arming (setting) / disarming which is housed in the Gallagher Cabinet.
(unsetting) of alarm zones. The Gallagher Dialler is 13.6V DC
powered and can share the same power
Dial-up Connection to Gallagher source as that provided for the Gallagher
Command Centre Controller.
The Gallagher Dialler can be used to
facilitate communications between the
Gallagher Command Centre server and
Gallagher Controllers located at remote
sites. This dial-up connection can be used
for remote site configuration including
access control for cardholders and alarm
configuration.

The Gallagher Dialler will dial-up on


demand, for example when an alarm
occurs or when the event buffer of the

9
Technical Specifications
GALLAGHER CONTROLLER 6000 AUGUST 2012
Operating System Windows CE 6
Power Supply Voltage 13.6 v DC±15%
Current (measured at 13.6 V DC with module connected)* Relays Operating
No relays 4 relays 8 relays
Controller 6000 175mA 320mA 460mA
Controller 6000HS 610mA 730mA 870mA

* Note: Current measurements are indicative only and exclude external devices. Currents have been rounded up to the nearest 5mA. Controller
6000HS measurements include the use of both primary and secondary high speed ethernet ports. Please refer to the Gallagher Connectivity
Guide and product Installation Notes for detailed power supply and operating characteristics.

Temperature Range Gallagher Controller 6000 -10o to +70o C


Gallagher Controller 6000 High Spec (HS) -10o to +55o C
Humidity 95% Noncondensing
Data Storage per Max. number of access zones Unlimited
Gallagher Controller 6000 Max. number of alarms zones 256
Max. number of access groups 2,000
Max. number of time schedules 400
Number of cardholders 500,000
Number of events 80,000
Max. number of doors 10
Max. inter-controller peer to peer connections 60
RS485 Device Communications (2 Ports) HBUS up to 1 Mbits per second
GBUS 2 wire at 38.4 Kbits per second
Sensor Bus 115.2kbits per second, 1000m max.
Aperio 19.2kbits per second, 1000m max.
Network Communications Network connection - Controller 6000 10/100 BaseT Ethernet Port
Network connection - Controller 6000 High Spec 10/100/1000 BaseT Ethernet Port

Network protocol TCP/IP - 256 bit AES symmetric


encryption for Controller to Server and
Inter-Controller communications

Compliance Standards CE, A-Tick, C-Tick, FCC and UL

GALLAGHER MODULES
Device Connectivity
Reader Connections HBUS Inputs Relay Outputs DC Outputs
Connections
Gallagher Wiegand
Gallagher 4H Module - - 4 12 4 2
Gallagher 8H Module - or - 8 24 8 4
Gallagher 4R Module 4 2 - 12 4 2
Gallagher 8R Module 8 4 - 24 8 4

10
Technical Specifications
GALLAGHER MODULES AUGUST 2012
Data Format 4R / 8R Modules Cardax IV & Wiegand Readers
4H / 8H Modules HBUS Readers & F22 Fence Controllers
Relay Specifications Resistive load 3 A at 24 V DC/AC
Inductive load 1 A at 24 V DC/AC
DC Outputs 0.5 A per output
Elevator Control Max. Number of shafts per Controller 6000 2
Max number of floors per shaft 75 (low level)
256 (high level)*
Gallagher Cabinets Refer to Gallagher Cabinet datasheet

GALLAGHER DIALLER
Dimensions Gallagher Dialler 113 x 54mm
Power Supply 13.6V ± 15%, 300mA
Temprature Range (ambient) -10 to +55°C
Mounting Gallagher Dialler plugs vertically into the serial port on the
Gallagher Controller
Communication RS232
Dial-Up Communications Dial up model Gallagher Dialler operating PPP protocol
Network Service PPP protocol using PSTN (telephone line)
connection

Contact ID protocol using PSTN


Alarm Monitoring Service
(telephone line) connection
Compliance Standards NZ Telepermit, A Tick C-Tick, CE

PART NUMBERS
Gallagher Controller 6000 C300100
Gallagher Controller 6000 High Spec C300101
Gallagher 4H Module C300142
Gallagher 8H Module C300182
Gallagher 4R Module C300141
Gallagher 8R Module C300181
Gallagher Cabinet C200104
Gallagher Dual Cabinet (with power supply) C200105
Gallagher Dialler C200620

Notes:
1. Compliance with other international standards will be proven as required. Please contact Gallagher for the latest list of approvals. All
Gallagher products must be installed in accordance with the Installation Notes to comply with international standards.
2. System configuration, network capabilities, and the volume of system activity affect performance. Please contact Gallagher technical
support for advice.

* Elevator system dependant

11
Gallagher World Headquarters REGIONAL OFFICES Disclaimer: System configuration, network capacities and the
volume of system activity affect performance. Please contact
Kahikatea Drive, Hamilton 3206 New Zealand............................................. +64 7 838 9800
Gallagher for advice. In accordance with the Gallagher policy of
Private Bag 3026, Hamilton 3240 Americas...................................................+1 888 430 0770 continuing development, design and specifications are subject
New Zealand Asia................................................................+852 2910 7912 to change without notice. Gallagher Group Limited is an ISO
Australia....................................................+61 2 9412 4477 9001:2008 Certified Supplier. Copyright © Gallagher Group
Limited 2012. All rights reserved.
TEL: +64 7 838 9800 India..........................................................+91 80 2661 1590
3E2057 – 08/12

EMAIL: sales@security.gallagher.co Middle East...................................................+9615 808728


South Africa............................................+27 11 974 4740
United Kingdom / Europe..........+44 2476 64 1234

security.gallagher.co

You might also like