SERVICE MANUAL
TABLE OF CONTENTS
ASSEMBLY SKETCH (HOOKUP): 2
BLOCK DIAGRAM:3
SCHEMATIC DIAGRAM: 4
TEST MODE: 5-7
PARTS LIST: 8
1. Start method
When the power supply is turned on while pressing the key shown in the table below
simultaneously, it starts in a special mode.
SWITCH
MODE NOTE
WRITE CANCEL UP DOWN ASSIGN
configuration 11 click calibration ON ON off off off
Internal inspection
inspection Control device inspection ON ON ON off off
Bypass
Send program ON ON off ON off
development Receive program ON ON off ON off only AX3 series
MIDI loop back test ON ON off ON off only AX3 series
3. Internal inspection
3.1 EEPROM collation (AX3G only)
When the inspection mode of AX3G gets booted, EEPROM read/write test will run
automatically. If 7 segment LED indicates “Bd”, either read or write process is at
fault.
3.2 EEPROM collation (AX3B/AX3A/AX5G/AX5B)
(1) Position the 11 click volume where 7 segment LED indicates “0.3”.
(2) Press WRITE.
(3) The result will be indicated at 7 segment LED as below.
“ok”…………….Succeeded.
“E1”……………Failed reading or writing.
“E2”……………Read/Write succeeded, but contents differ from factory data.
3.3 Battery voltage inspection
(1) Press WRITE and CANCEL simultaneously.
(2) Tens place digit and ones place digit of AD value will be indicated at the 7
segment LED.
* AX3 series indicates the right dot of 7 segment LED when the value is over
228, and indicates the left dot then the value is below 212.
* AX5 series indicates the right dot of 7 segment LED when the value is over
236, and indicates the left dot when the value is below 219.
4. Controller inspection
Check the control device and the indication, following the matrix below.
INDICATION
CONTROL NOTE
UP DOWN VOL WAH EXP 7 SEGMENT LED
TOGG
UP off off off off indicates revision.
LE