Individual Check

Nozzle dia = 8 in Node 2250


NEMA Factor = 2
N lb N-M lb-ft
Fx -608.22 -136.73 Mx -784.80 -578.86
Fy -215.82 -48.52 My -1343.97 -991.30
Fz 1451.88 326.40 Mz 667.08 492.03

FR = 357.19 lb
MR = 1248.95 lb-ft
Correction = NO
De = (16+NOMINAL DIA)/3 in

De = 8.00 in ---CORRECTION REQUIRED IF DIA IS MORE THAN 8"

3FR+MR<=500De --------------------------------------------------------LIMIT 1
3FR+MR < (500De)*FAC --------DIAMETER IS MORE THAN 8"
2320.51 8000.00
Ratio 0.29

Combine Check
N lb N-M lb-ft
Fxc 882.9 198.5 Mxc -2697.8 -1989.8
Fyc -78.5 -17.6 Myc 441.5 325.6
Fzc -824.0 -185.3 Mzc 0.0 0.0

Frc = 272.08 lb
Mrc = 2016.31 lb-ft

Inlet Flange Area = 50.27 in2


Outlet Flange Area = 153.94 in2
Total flange area = 204.20 in2

Equivalent Dia = 16.12 in ----- CORRECTION REQUIRED IF DIA IS MORE THAN 9"
= (18+Equivalent dia)/3 in

Dc 11.375
2Frc+Mrc < 250Dc*FAC --------------------------------------------LIMIT 2
2560.46 5687.42
Ratio 0.45
-----------------------------------------------------LIMIT 3 ------------------------------------------------------
Nozzle dia = 14 in Node 10

N lb N-M lb-ft
Fx 1491.12 335.22 Mx -1912.95 -1410.98
Fy 137.34 30.88 My 1785.42 1316.92
Fz -2275.92 -511.65 Mz -667.08 -492.03 Comprssor displacement at 250
Y
FR = 612.46 lb
MR = 1991.79 lb-ft Comprssor displacement at 115
Correction = YES Y
De = (16+NOMINAL DIA)/3
Comprssor displacement at 115
De = 10.00 in ---CORRECTION REQUIRED IF DIA IS MORE THAN 8"

3FR+MR<=500De Y
3FR+MR < (500De)*FAC
3829.17 10000.00
Ratio 0.38
Comprssor displacement at 250
4.53178654

Comprssor displacement at 115


1.963

Comprssor displacement at 115

-1.0807425

-533 -5228.73 152 1491.12


-2528 -24799.68 14 137.34
-400 -3924 -232 -2275.92
-837 -8210.97 -195 -1912.95
316 3099.96 182 1785.42
-68 -667.08 -68 -667.08