G3 Secondary Beam Additional Bolts Calculations - 1
Based on Hilti guide, M24 bolt to be embedded at 210mm depth into RC beam
Hilti CC method which is simplified version of ETAG ANNEX C
Shear Forces
Concrete Edge Design Resistance
Vrd,c = Vrd0,c * fBV * fAr,v * Fb,v
= 18.5*1.22*2.0*0.5952
= 26.87 kN > 23.33 kN OK
where,
Vrd0,c = 18.5kN for M24 with 105mm min from concrete edge
fBV = 1.22 for Grade 30 concrete
Fb,v = 2.00