Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Current Limiting

UL/CSA Fuses
Low-Voltage Limiter Non Time-Delay

Circuit Protection
Catalog Number ANL (35 - 500A) Average Time-Current Curve
125Vac or Less

150
225 275

400 350
500
AMP

100
130

325
200
35
50
80
0.88" RATING
(22.2mm) 100

General Purpose
UL/CSA Fuses
0.34"
(8.7mm)

2.44" 3.19" 10
(61.9mm) (81.0mm)

TIME IN SECONDS

Purpose Fuses
Special
0.88"
(22.2mm)
1
0.34"
(8.7mm)

Amp Ratings
ANL 125Vac

Fuses & Holders


Canadian
35 130 350 .1
40 150 325
50 175 350
60 200 400
80 225 500
100 250 —

.01

1000
100

10,000
10

ANL Specifications:
Non-Time-Delay
CURRENT IN AMPS

Voltage Fuses
Medium
Voltage Rating: 80Vdc, 125Vac

Interrupting Rating: 6,000 Amps


Fuse Block 4164
Recommended Fuse Block: 4164 Holes drilled 0.217” diameter with 0.438” counterbore with
5/16-24 stud.
Characteristics:
• Isolates faults in equipment systems such as lift trucks Dimensions - inches
and other battery operated systems.
• Silver-plated copper links.
• Link element visible through mica window.
Holders & Misc.
1.563" Fuse Blocks,
1" 5
16 -24

0.483"

3-13/32"

15/16"
Section
Application

For additional information, visit www.edisonfuse.com


57

You might also like