Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Machine Translated by Google

Technical Specification

Technical Specification For Cable

Cable Type Cable Type


70 square conductor

Polyurethane reel cable 3*50+3*16


16 square conductor
General Description Application scope

PVC strip filler


Fixed/mobile installations in industrial installations

NO. Number PUR outer sheath

Kevlar braided reinforcement

Cable ConstructionCable structure

Conductor Material conductor material Bare copper wire Bare copper wire

Conductor Section Conductor Section/mm 2 50mm2 16mm2

Conductor Structure Conductor structure/mm 1750/0.19mm 560/0.19mm

Conductor Strand OD. Strand outer diameter/mm 10.2±0.2mm 5.9±0.2mm

conductor
Insulation Material Thermoplastic Elastomer Material TPE Thermoplastic Elastomer Material TPE

Insulation Color Black No. 1-3 Yellow/Green No. 1-3

Insulation Thickness/mm 1.4±0.2mm 0.9±0.2mm

Insulation OD. Insulation outer diameter/mm 13.5±0.2mm 7.8±0.2mm

Cabling Structure 3+3 composite structure twisted cable

Cabling

BRMCFLEXCS/CABLE Filler filling

Wrapping
Galvanized flexible wire rope+Gap PP rope

Non-woven wrapped cable structure

Jacket Material sheath material Environmentally friendly nitrile mixed elastomer material PVC

Inner
Foaming Thickness/mm 2.0±0.2
sheath
inner sheath Jacket Color RLA0012 color number, black

Approximate OD. Approximate outer diameter of finished product/mm 34±0.5mm

Braiding Braiding Material Kevlar(12+12)

Braiding Coverage Braiding Coverage 50%

Jacket Material sheath material Polyurethane Polyurethane

Jackets Foaming Thickness/m m 3.5±0.2mm

Jacket Color Black Black

Approximate OD. Approximate outer diameter of finished product/mm 40±2mm

Mark printing Company Name Model Specification Voltage Meter Standard

Electric ical Character ist ics Instal lat ion ConditionsInstallation conditions

Max. DC Resistance at 20°C (ÿ/kM) Min.Bending Radius Minimum


0.272/1.21 8D
Conductor DC resistance at 20°C (ÿ/kM) bending radius during installation

Operation temperature Ambient


Rated Voltage Rated voltage (V) 0.6/1KV -40—+80ÿ
temperature during installation

You might also like