REAR ELEVATION
LEFT SIDE ELEVATION LAND USE AND ZONING
STAIR SECTION
SCHEDULE OF SLAB
FOOTING SCHEDULE
SCHEDULE OF BEAMS
S-3 TRUSS SCHEDULE
33.1
5 7.49 SHEET NO.:
E-1 GENERAL NOTES
ELECTRICAL
2.9
4.04
LEGEND
2.99
SECOND FLOOR POWER LAYOUT
3.73
COMPUTATION OF LOAD
11.8
DETAIL OF SEPTIC TANK
P-2 GROUND FLOOR WATER LINE LAYOUT
SECOND FLOOR WATER LINE LAYOUT
5
GROUND FLOOR SANITARY LINE LAYOUT
4.04
37.4
PLAYGROUND
9
5.11
10.7
BUILDING AREA
OUTDOOR
RECREATIONAL
AREA
SANITARY
13.5
35.0
7
4
13.2
GARDEN
ELECTRICAL
9.47
9
4
12.8
4
6 33.1
A1
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY
INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT SITE DEVELOPMENT PLAN
PERSPECTIVE
-REPUBLIC ACT NO. 9266
ARCH. KATHLEEN NUÑEZ BESCASER,uap
A B C D E A B C D E
1 1
A4 A 4
18.85
3.75 2.4 7.05 3.55 2.25 17.8
6 4.4 6.2 1.2
2.25
2.25
3.26
3.26
1 W W
1
D
1 1 1
3.2
DIRTY KITCHEN &
KITCHEN W
1
LAUNDRY AREA
2 W W W
D 1 1 1
1
7.05
W
4 BEDROOM 1 BEDROOM 2
W
1.95
5.26
5
W DINING AREA T&B W
1 1
2 D
D D
1 W
W 5 4
1 2 W
4
3.1
MAID'S QUARTER
3 3 D D
18.12
18.12
19.95
19.95
1.13
D 2 2
D
1.4
1.4
W
5 T&B 5
W T&B W 4
5 5
D
4 STORAGE ROOM
2
GUEST ROOM
D
3.6
W 3 W D W
1 5 5 1
T&B
D
2
D
2
4 D
7.2
LIVING AREA W
UP 2 D
7
7
4
2 2
W W
A4 1 D 2 MASTER'S
2 GUEST ROOM
3.68
BEDROOM
W
PARKING UTILITY 1
CARPORT W
D W W D W W D W
1 4 4
1 1 1 3 1 1
5 5
1.2
1.2
BALCONY
2.25
2.25
PORCH
A2
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY
INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT SECOND FLOOR PLAN
RAL 1 RAL 1
1.9 1.04
1.9 1.52
RAL 2 RAL 2
CL CL
FFL
CARPORT FL
CARPORT FL
NGL NGL
E D C B A 5 4 3 2 1
RAL 1 RAL 1
1.9 1.04
RAL 2
2.95
2ND FLR CL 2ND FLR CL
0.4 2.7 0.3 2.7
9.05
2ND FFL 2ND FFL
CL CL
CARPORT FL CARPORT FL
NGL NGL
A3
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY
INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT REAR ELEVATION
LEFT SIDE ELEVATION
-REPUBLIC ACT NO. 9266 RIGHT SIDE ELEVATION
ARCH. KATHLEEN NUÑEZ BESCASER,uap
LEGENDS
A B C D E
INTEGRATED LED LIGHTING FIXTURE
2ND FLR CL
0.2 0.21 2.7 0.3 2.7
9.05
CL
CARPORT FL
NGL
1 CROSS SECTION
SCALE 1:100 MTS
A 4
5 4 3 2 1
RAL 1
2.95
2ND FLR CL
0.4 2.7 0.3 2.7
9.05
CL
CARPORT FL
1 REFLECTED CEILING PLAN
SCALE 1:100 MTS
A 4
NGL
2 LONGITUDINAL SECTION
SCALE 1:100M
A 4
A4
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY
INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT LONGITUDINAL SECTION
REFLECTED CEILING PLAN
-REPUBLIC ACT NO. 9266
ARCH. KATHLEEN NUÑEZ BESCASER,uap
LEGENDS
10.41
FF1
16.06
16.06
FF5
5.65
FF3
FF4
FF2 FF2 FF5 FF3 16
FF2
FF2 FF3
FF3
2 ROOF PLAN
A 5 SCALE 1:100 MTS
FF1
FF1
1 SCHEDULE OF FINISHES
A 5 SCALE 1:100 MTS
A5
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY
INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT ROOF PLAN
1.2 0.75
15
14
13
12
11
2.8
2.1
2.1
2.1
2.1
2.1
10
9
8
4
7
6
5
4 3 2 1 0
DESCRIPTION SEMI-SOLID PANEL DOOR SOLID PANEL DOOR ANALOK ALUMINUM SLIDING DOOR ANALOK ALUMINUM TWO-PANEL DOOR PVC DOOR W/ BOTTOM LOUVER
1.2
UP LOCATION MAIN ENTRANCE & EXIT, MAID'S QUARTER, PARKING UTILITY MASTER'S BEDROOM, BEDROOMS, PARKING UTILITY, TERRACE BALCONY T&B
QUANTITY 5 SETS GUEST ROOMS, STORAGE ROOM, MAID'S QUARTER 1 SET 1 SET 4 SETS
MARK D1 9 SETS D3 D4 D5
D2
0.3
1.2
1.2
1.2
1.2
2.1
2.1
2.1
2.1
2.1
1.8
15
0.9
0.9
0.9
1.2
14
13
12
11
10
2.2
9 DESCRIPTION ANALOK ALUMINUM SLIDING WINDOW ANALOK ALUMINUM FOUR-PANEL SLIDNG WINDOW ANALOK ALUMINUM THREE-PANEL SLIDING WINDOW ANALOK ALUMINUM ONE PANEL WINDOW ANALOK ALUMINUM AWNING WINDOW
8 LOCATION LIVING AREA, DINING AREA, KITCHEN, MASTER'S BEDROOM, LIVING AREA LIVING AREA MAID'S QUATER, MASTER'S BEDROOM, BALCONY T&B
3
7 QUANTITY BEDROOMS, GUEST ROOMS,PARKING UTILITY, STORAGE 1 SET 1 SET 6 SETS 4 SETS
6 MARK 17 SETS W2 W3 W4 W5
5 W1
4
3
0.8
2
1
0
A6
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY
INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT DETAIL OF STAIRS
SCHEDULE OF DOORS AND WINDOWS
-REPUBLIC ACT NO. 9266
ARCH. KATHLEEN NUÑEZ BESCASER,uap
A B C D
10.6
A B C-A D E
4.5 2.35 3.75
16.6
3.2
1
FB-1 RB FB-1
1.95
5.41
5.41
FB-5 FB-5
3.8
C1F2 C2F2
C2F2
3.1
C1F2 FB-2 RB FB-2
3 C2F2
C2F2 2
15.45
C1F2
2.05
RB RB RB RB
13.66
3.75
3.75
@10MM
TEMPERATURE
BARS @0.50 M
BOTHWAYS
(TYPICAL)
1.9
7.2
4.5
4.5
4.5
FB-5 FB-5
1 FOUNDATION PLAN
SCALE 1:100 MTS
2 SECOND FLOOR FRAMING PLAN
S 1 SCALE 1:100M
S 1
S1
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY
INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT SECOND FLOOR FRAMING PLAN
A B C-B D E
3. THE CONTRACTOR SHALL EXAMINE THE DRAWING 2. BARS SHALL BE CLEAN OF RUST, GREASE OR OTHER MATERIALS LIKELY YO
AND SHALL NOTIFY THE ARCHITECT/ENGINEER OF ANY
DESCRIPANCIES HE MAY FIND BEFORE PROCEEDING WITH IMPAIR BOND, ALL REINFORCING BAR BENDS SHALL BE MADE COLD.
THE WORK OR DURING CONSTRUCTION.
1.79
1.79
7. DO NOT SCALE DRAWINGS, CALLED OUT DIMENSIONS
AND STANDARD CODE REQUIREMENTS SHALL GOVERN ITEM COVER
OVER UNSCALED DRAWINGS.
CONCRETE CAST AGAINST EARTH 75 MM 2-B
8. SPECIAL NOTE: DIMENSIONS INDICATED ON THE STRUCTURAL EXPOSED TO EXTERIOR OF WEATHER 38 MM
DRAWINGS SHALL BE COORDINATED WITH THE ARCHITECTURAL
DRAWINGS. ARCHITECTURAL DRAWINGS SHALL BE USED TO FORMED SURFACE BELOW GRADE 50 MM
DEFINE DETAILED CONFIGURATIONS, ELEVATIONS, OPENINGS,
5.41
5.42
JOINTS, SLOPES, ETC. SLAB ON GRADE 50 MM
COLUMNS / BEAMS 38 MM
15.45
STRENGTH. 3
A. 210 KG/CM^2 (3000 PSI) TYPICAL CONCRETE DENSITY=2400 KG/CM^2 (150 PCF)
FORMWORKS
3.75
B. 175 KG/CM^2 (2500 PSI) MAX SLUMP (TYPICAL) = 100 MM (4 INCH)
3.95
1. INFORM ARCHITECT/ENGINEERS OF OTHER MISCELLANEOUS CONCRETE STRUCTURAL 1. FORMWORKS SHALL BE PROVIDED FOR ALL CONCRETE INDICATED UNLESS SECURED
ELEMENT NOT SHOWN ABOVE TO DETERMINE THEIR RESPECTIVE COMPRESSIVE STRENGTH OTHERWISE FORMS SHALL BE SET THRU TO LINE AND GRADE AND MAINTAINED
SO AS TO INSURE COMPLETED WORK WITHIN THE ALLOWABLE TOLERANCES
STRUCTURAL ELEMENTS CONCRETE AGGREGATES
SPECIFIED AND SHALL BE MORTAR TIGHT. 4
FOUNDATION 19 CM (3 4 INCH) 2. FORMS AND THEIR SUPPORTS SHALL BE DESIGNED SO AS NOT TO DAMAGE
PREVIOUSLY PLACED STRUCTURE.
SLAB ON GRADE 19 CM (3 4 INCH)
4.5
3. NO CONSTRUCTION LOAD SHALL BE SUPPORTED ON NOR ANY SHORING REMOVED
4.3
SUSPENDED SLAB 19 CM (3 4 INCH) FROM ANY PART OF THE STRUCTURE UNDER CONSTRUCTION EXCEPT WHEN THAT
PORTION OF THE STRUCTURE IN COMBINATION WITH THE REMAINING FORMING
MASONRY WALL FOOTING 19 CM (3 4 INCH) AND SHORING SYSTEM HAS SUFFICIENT STRENGTH TO SUPPORT SAFELY ITS
WEIGHT AND THE ADDITIONAL IMPOSED LOADS.
STAIRS 19 CM (3 4 INCH)
4. FORMS SHALL BE REMOVED IN SUCH MANNER AS NOT TO IMPAIR SAFETY 5
1.2
AND SERVICE ABILITY OF THE STRUCTURE.
ARE IMPOSED
1. ALL NON LOAD BEARING TYPE BLOCKS SHALL HAVE A UNIT WEIGHT NOT TO EXCEED 80 PCF.
3. UNLESS OTHERWISE NOTED, SCLID GROUT SHALL MEAN ALL CESS WITH OR
WITHOUT REINFORCING BE GROUTED.
S2
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY
INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT CONCRETE NOTES
CONSTRUCTION JOINTS
FORMWORKS
F1 2 1.40 1.40 12-16 MM 7-16 MM 1.50 B-1 4.5 0.25 0.4 PROVIDE 10 MM DIAMETER STIRRUPS FOR SHORT SPAN
10 MM STIRRUPS 2 @ 50 MM, 2 @ 75 MM, 2 @ 100 MM,
STIRRUPS: 2 @ 0.05
2 @ 150 MM, REST @ 200 MM FROM FACE OF COLUMN
2@ 50MM, F2 21 1.60 1.60 10-16 MM 5-16 MM 1.50 B-1 2.35 0.25 0.4 5 @ 0.075
400
400
200
4@ 75MM, 5 @ 0.10 PROVIDE 10 MM DIAMETER STIRRUPS FOR 60 METER SPAN
2 @ 50 MM, 5 @ 75 MM, 5 @ 100 MM,
6@ 100MM 200 REST @ 0.20 MM O.C. 5 @ 150 MM, REST @ 200 MM FROM FACE OF COLUMN
REST AT F3 1 1.00 1.00 10-16 MM 5-16 MM 1.00 B-1 3.75 0.25 0.4
150 MM 200 250
4-12 MM
B-2 5.41 0.25 0.4
8-16 MM 8-16 MM
REBARS W/ REBARS W/ REBARS W/ LEGEND:
10MM TIES 10MM TIES 10MM TIES B-2 3.75 0.25 0.4 100 MM CONCRETE SLAB ON FILL
@ 200 MM O.C @ 200 MM O.C @ 200 MM O.C
FFL
NGL
COMPACTED SOIL
1.5
1.5
3 DETAIL OF SLAB ON FILL
1
TYPICAL FOOTING
0.3
0.3
0.3
10 MM TIES W/ 10 MM TIES W/ 10 MM TIES W/ 10 MM TIES W/
# 16 G.I TIE WIRE # 16 G.I TIE WIRE # 16 G.I TIE WIRE # 16 G.I TIE WIRE
1.60
1.40
1.00
1.40 1.60 1.60 1.00
CANTILEVER L1
2.00
L1/4 L1/4 L2/4 L2/4 WIDTH
B
BAR "C" EXTRA TOP BAR "C" EXTRA TOP
BAR "A" CONT. TOP BAR "E" STIFF BARS
TOP BARS
STIRRUPS
DEPTH
STIFF BARS
D
EXTERIOR SUPPORT EXTERIOR SPAN INTERIOR SUPPORT INTERIOR SUPPORT INTERIOR SUPPORT
S3
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY
INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT
FOOTING SCHEDULE
BEAM SCHEDULE
TYPICAL RC BEAM ELEVATION
S3W
0.15mts. F. C.O. ABOVE COUNTER S
INTENDED.
6. ALL LIGHTINGS AND CONVENIENCE RECEPTACLE CIRCUIT S S
S
HOMERUNS SHALL BE WIRED NOT LESS THAN 3.50sq.mm.
COPPER INDICATORS UNLESS OTHERWISE INDICATED IN THE
PLAN.
S
7. ALL LIGHTINGS AND PANEL BOARDS SHALL BE IN CIRCUIT
BREAKER TYPE, FLUSH MOUNTED OR AS INDICATED IN THE
PLANS.
S
8. ALL OUTDOOR INSTALLATION SHALL BE WEATHERPROOF.
9. UNLESS OTHERWISE SPECIFIED, JUNCTION BOX AND UTILITY
BOX SHALL BE PROVIDED WHENEVER REQUIRED. ALTHOUGH
SUCH BOXES ARE NOT SHOWN IN THE PLANS.
10. ALL ELECTRICAL WORKS HEREIN SHALL BE DONE UNDER
THE DIRECT AND IMMEDIATE SUPERVISION OF A DULY
LICENSED ELECTRICAL ENGINEER.
1 GROUND FLOOR LIGHTING LAYOUT LPP 2 SECOND FLOOR LIGHTING LAYOUT
SCALE 1:100 MTS SCALE 1:100M
E 1 E 1
20A 20A
1 2
LEGENDS 3
20A 20A
4
40A 20A
INTEGRATED LED LIGHTING FIXTURE FLUSH WALL SWITCH
/CEILING LIGHT
S 5 6
E1
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY
INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT LEGENDS
GROUND FLOOR LIGHTING LAYOUT
-REPUBLIC ACT NO. 9266 SECOND FLOOR LIGHTING LAYOUT
ARCH. KATHLEEN NUÑEZ BESCASER,uap
11
WH HO2
R
LPP
10 LPP
6
AT
8 1ST FLR
7
12 WM
5
REF
WP
WP
WP 9
WP
WP
ACU
WP
CRT LOAD DESCRIPTION LTS CO OTHER VA PER AMP PER SIZE OF BRKS SIZE OF HOMERUN
NO. LOAD CIRCUIT CIRCUIT F P T WIRE CONDUIT
3 SCHEDULE OF LOADS
SCALE NTS
E 2
E2
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY
INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT GROUND FLOOR POWER LAYOUT
SECOND FLOOR POWER LAYOUT
-REPUBLIC ACT NO. 9266 SCHEDULE OF LOADS
ARCH. KATHLEEN NUÑEZ BESCASER,uap
GENERAL NOTES
1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE 32MM
WH
GALVANIZED IRON PIPE
HO2
EXECUTED ACCORDING TO THE PROVISIONS OF THE
PHILLIPINES PLUMBING CODE, THE NATIONAL BUILDING
CODE AND THE RULES AND REGULATIONS OF THE CITY.
2. THE CONTRACTOR SHALL COORDINATE THE
DRAWINGS WITH OTHER RELATED DRAWINGS AND
SPECIFICATIONS. THE ARCHITECT SHALL BE
IMMEDIATELY NOTIFIED OF ANY DISCREPANCY FOUND
HEREIN.
3. ALL PIPES SHALL BE INSTALLED AS INDICATED, ANY
RELOCATION REQUIRED FOR PROPER EXECUTION OF 20MM PVC PIPE (COLD)
SPECIFIED.
6. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE
IN ACCORDANCE WITH THE MANUFACTURERS
SPECIFICATIONS.
7. THE CONTRACTOR SHALL VERIFY ALL EXISTING 20MM PVC PIPE (COLD)
UTILITIES AT THE SITE AND COORDINATE THE WORKS
WITH SEWER LINE EFFLUENT DISPOSAL POINT AND
WATERLINE SERVICE CONNECTING POINT.
8. ALL PIPES SHALL BE SIZED IN MILLIMETERS AND ALL 32MM GALVANIZED IRON PIPE
0.1
SEWER PIPE LINE ANGULAR BAR
FLOOR DRAIN PIPE
0.50
HOSE BIBB PIPE RISER
0.1
FAUCET CATCH BASIN
10MM REINFORCEMENT
BARS @ 0.25 M O.C
WATER HEATER WATER PUMP PLAN SECTION
BIDET 3 DETAIL OF CATCH BASIN
SCALE NTS
P 1
P1
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY
INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT LEGENDS
GROUND FLOOR WATERLINE LAYOUT
-REPUBLIC ACT NO. 9266 SECOND FLOOR WATERLINE LAYOUT
ARCH. KATHLEEN NUÑEZ BESCASER,uap
150 MM PVC DRAINAGE PIPES
PART OF SEPTIC
TANK
100MM SOIL PIPE
200MM DRAINAGE
50MM WASTE PIPE
PIPE
TO STREET
CANAL
0.15
WATERCLOSET GATE VALVE
0.20
0.40 0.20
LAVATORY CHECK VALVE MANHOLE INLET AIR SPACE
2% SLOPE OUTLET
0.30
INLET
2.00
1.20
1.50
8
1.30
1.20
FLOOR DRAIN SEWER PIPE LINE MANHOLE DIGESTIVE CHAMBER LEACHING
CHAMBER
HOSE BIBB PIPE RISER OUTLET
MANHOLE
0.20
0.20
0.15
SECTION
P2
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY
INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT GROUND FLOOR SANITARY LAYOUT
SECOND FLOOR SANITARY LAYOUT
-REPUBLIC ACT NO. 9266 DETAIL OF SEPTIC TANK
ARCH. KATHLEEN NUÑEZ BESCASER,uap
32MM GALVANIZED IRON PIPE
WATER HEATER
COLD WATER LINE PIPE
32MM GALVANIZED IRON PIPE RISER TO GROUND FLOOR
WATER PUMP
LEGENDS
WATERCLOSET GATE VALVE
BIDET
P3
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY
INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT