TABLE OF CONTENTS

SHEET NO.: ARCHITECTURAL


A-1 PERSPECTIVE REPUBLIC OF THE PHILIPPINES
SITE DEVELOPMENT PLAN Department of Public Works & Highway
TABLE OF CONTENTS

A-2 GROUND FLOOR PLAN OFFICE OF THE BUILDING OFFICIAL


SECOND FLOOR PLAN

A-3 FRONT ELEVATION DISTRICT . CITY . MUNICIPALITY


RIGHT ELEVATION

REAR ELEVATION
LEFT SIDE ELEVATION LAND USE AND ZONING

A-4 CROSS SECTION


LONGITUDINAL SECTION

A-5 SCHEDULE OF FINISHES

SCHEDULE OF DOORS AND WINDOWS

A-6 SECTION OF MAIN STAIRS


MAIN STAIR PLAN

STAIR SECTION

SHEET NO.: STRUCTURAL


S-1 STRUCTURAL SPECIFICATIONS
FOUNDATION PLAN LINE AND GRADE
SECOND FLOOR FRAMING PLAN
ROOF FRAMING PLAN

S-2 SCHEDULE OF COLUMNS

SCHEDULE OF SLAB
FOOTING SCHEDULE
SCHEDULE OF BEAMS
S-3 TRUSS SCHEDULE

3.93 TRUSS DETAIL

33.1
5 7.49 SHEET NO.:
E-1 GENERAL NOTES
ELECTRICAL

2.9

4.04
LEGEND

POWER RISER DIAGRAM

1 PERSPECTIVE E-2 GROUND FLOOR LIGHTING LAYOUT ARCHITECTURAL


15.1 A 1 SCALE NONE
SECOND FLOOR LIGHTING LAYOUT

GROUND FLOOR POWER LAYOUT

2.99
SECOND FLOOR POWER LAYOUT

3.73
COMPUTATION OF LOAD

SHEET NO.: PLUMBING


P-1 GENERAL NOTES
LEGEND AND ABBREVIATION

DETAIL OF AREA DRAIN/CATCH BASIN

11.8
DETAIL OF SEPTIC TANK
P-2 GROUND FLOOR WATER LINE LAYOUT
SECOND FLOOR WATER LINE LAYOUT

5
GROUND FLOOR SANITARY LINE LAYOUT
4.04

SECOND FLOOR SANITARY LINE LAYOUT STRUCTURAL

37.4
PLAYGROUND

9
5.11
10.7

BUILDING AREA

OUTDOOR
RECREATIONAL
AREA

SANITARY
13.5
35.0

7
4

13.2

GARDEN
ELECTRICAL
9.47
9

4
12.8
4
6 33.1

2 SITE DEVELOPMENT PLAN


SCALE 1:200M
A 1

PROJECT TITLE SHEET CONTENTS SHEET NO.


CAVITE STATE UNIVERSITY BACTOL, RONEL L. ALL MEASUREMENT ARE TO BE VERIFIED ON SITE, ALL DISCREPANCIES ARE TO BE
IMMEDIATELY REPORTED TO ARCHITECT. TABLE OF CONTENTS

A1
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY

INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT SITE DEVELOPMENT PLAN
PERSPECTIVE
-REPUBLIC ACT NO. 9266
ARCH. KATHLEEN NUÑEZ BESCASER,uap
A B C D E A B C D E

1 1
A4 A 4

18.85
3.75 2.4 7.05 3.55 2.25 17.8
6 4.4 6.2 1.2
2.25

2.25

3.26

3.26
1 W W
1
D
1 1 1

3.2
DIRTY KITCHEN &
KITCHEN W
1
LAUNDRY AREA
2 W W W
D 1 1 1
1
7.05

W
4 BEDROOM 1 BEDROOM 2
W

1.95

5.26
5
W DINING AREA T&B W
1 1

2 D
D D
1 W
W 5 4
1 2 W
4

3.1
MAID'S QUARTER

3 3 D D

18.12

18.12
19.95

19.95

1.13
D 2 2
D
1.4

1.4
W
5 T&B 5
W T&B W 4
5 5
D
4 STORAGE ROOM
2
GUEST ROOM
D

3.6
W 3 W D W
1 5 5 1
T&B

D
2
D
2
4 D

7.2
LIVING AREA W
UP 2 D
7

7
4
2 2
W W
A4 1 D 2 MASTER'S
2 GUEST ROOM

3.68
BEDROOM
W
PARKING UTILITY 1

CARPORT W
D W W D W W D W
1 4 4
1 1 1 3 1 1

5 5

1.2

1.2
BALCONY
2.25

2.25
PORCH

3 3 4.5 2.35 3.75 1.2


6 3.35 7.25 2.25 17.8
18.85

1 GROUND FLOOR PLAN 2 SECOND FLOOR PLAN


SCALE 1:100 MTS SCALE 1:100M
A 2 A 2

PROJECT TITLE SHEET CONTENTS SHEET NO.


CAVITE STATE UNIVERSITY BACTOL, RONEL L. ALL MEASUREMENT ARE TO BE VERIFIED ON SITE, ALL DISCREPANCIES ARE TO BE
IMMEDIATELY REPORTED TO ARCHITECT. GROUND FLOOR PLAN

A2
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY

INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT SECOND FLOOR PLAN

-REPUBLIC ACT NO. 9266


ARCH. KATHLEEN NUÑEZ BESCASER,uap
A B C D E 1 2 3 4 5

RAL 1 RAL 1

1.9 1.04

1.9 1.52
RAL 2 RAL 2

2ND FLR CL 2ND FLR CL

0.2 0.2 2.7 0.3 2.7

0.4 2.7 0.3 2.7


9.05
9.05

2ND FFL 2ND FFL

CL CL

FFL
CARPORT FL
CARPORT FL
NGL NGL

1 FRONT ELEVATION 2 LEFT SIDE ELEVATION


SCALE 1:100 MTS SCALE 1:100M
A 3 A 3

E D C B A 5 4 3 2 1

RAL 1 RAL 1
1.9 1.04

RAL 2

2.95
2ND FLR CL 2ND FLR CL
0.4 2.7 0.3 2.7

0.4 2.7 0.3 2.7


9.05

9.05
2ND FFL 2ND FFL

CL CL

CARPORT FL CARPORT FL

NGL NGL

3 REAR ELEVATION 4 RIGHT SIDE ELEVATION


SCALE 1:100 MTS SCALE 1:100M
A 3 A 3

PROJECT TITLE SHEET CONTENTS SHEET NO.


CAVITE STATE UNIVERSITY BACTOL, RONEL L. ALL MEASUREMENT ARE TO BE VERIFIED ON SITE, ALL DISCREPANCIES ARE TO BE
IMMEDIATELY REPORTED TO ARCHITECT. FRONT ELEVATION

A3
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY

INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT REAR ELEVATION
LEFT SIDE ELEVATION
-REPUBLIC ACT NO. 9266 RIGHT SIDE ELEVATION
ARCH. KATHLEEN NUÑEZ BESCASER,uap
LEGENDS
A B C D E
INTEGRATED LED LIGHTING FIXTURE

FLUORESCENT FIXTURE WITH DIFFUSER


RAL 1
1.911.04
RAL 2
CEILING FAN WITH LED LIGHTING FIXTURE

2ND FLR CL
0.2 0.21 2.7 0.3 2.7
9.05

BALCONY MASTER'S 2ND FLOOR GUEST ROOM


2ND FFL BEDROOM

CL

FFL CARPORT PARKING UTILITY LIVING AREA

CARPORT FL
NGL

1 CROSS SECTION
SCALE 1:100 MTS
A 4

5 4 3 2 1

RAL 1
2.95

2ND FLR CL
0.4 2.7 0.3 2.7
9.05

2ND FFL BALCONY 2ND FLOOR BEDROOM 1

CL

LIVING AREA DINING AREA KITCHEN

CARPORT FL
1 REFLECTED CEILING PLAN
SCALE 1:100 MTS
A 4
NGL

2 LONGITUDINAL SECTION
SCALE 1:100M
A 4

PROJECT TITLE SHEET CONTENTS SHEET NO.


CAVITE STATE UNIVERSITY BACTOL, RONEL L. ALL MEASUREMENT ARE TO BE VERIFIED ON SITE, ALL DISCREPANCIES ARE TO BE
IMMEDIATELY REPORTED TO ARCHITECT. CROSS SECTION

A4
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY

INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT LONGITUDINAL SECTION
REFLECTED CEILING PLAN
-REPUBLIC ACT NO. 9266
ARCH. KATHLEEN NUÑEZ BESCASER,uap
LEGENDS

FF1 SLATE RECALL TILES 60x60


FF2 CONCRETE POURING SMOOTH FINISH
FF3 WAX HARDWOOD FINISH
FF4 CERAMIC TILES 60x60 16
FF5 CERAMIC TILES 30x30 3 13

10.41
FF1

16.06

16.06
FF5

FF5 FF3 FF3

5.65
FF3

FF8 FF4 FF5

FF4
FF2 FF2 FF5 FF3 16

FF2

FF2 FF3
FF3

2 ROOF PLAN
A 5 SCALE 1:100 MTS
FF1
FF1

1 SCHEDULE OF FINISHES
A 5 SCALE 1:100 MTS

PROJECT TITLE SHEET CONTENTS SHEET NO.


CAVITE STATE UNIVERSITY BACTOL, RONEL L. ALL MEASUREMENT ARE TO BE VERIFIED ON SITE, ALL DISCREPANCIES ARE TO BE
IMMEDIATELY REPORTED TO ARCHITECT. SCHEDULE OF FINISHES

A5
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY

INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT ROOF PLAN

-REPUBLIC ACT NO. 9266


ARCH. KATHLEEN NUÑEZ BESCASER,uap
1.95

1.2 0.75

0.9 0.8 1.6 1.6 0.6

15

14
13
12
11
2.8

2.1

2.1

2.1

2.1

2.1
10
9
8

4
7
6
5
4 3 2 1 0
DESCRIPTION SEMI-SOLID PANEL DOOR SOLID PANEL DOOR ANALOK ALUMINUM SLIDING DOOR ANALOK ALUMINUM TWO-PANEL DOOR PVC DOOR W/ BOTTOM LOUVER
1.2

UP LOCATION MAIN ENTRANCE & EXIT, MAID'S QUARTER, PARKING UTILITY MASTER'S BEDROOM, BEDROOMS, PARKING UTILITY, TERRACE BALCONY T&B
QUANTITY 5 SETS GUEST ROOMS, STORAGE ROOM, MAID'S QUARTER 1 SET 1 SET 4 SETS
MARK D1 9 SETS D3 D4 D5
D2

1 MAIN STAIR PLAN


A 6
SCALE 1:500M
1.2 2.4 1.8 0.6 1.2

0.3
1.2

1.2

1.2
1.2
2.1

2.1

2.1

2.1

2.1
1.8
15
0.9

0.9

0.9
1.2
14
13
12
11
10
2.2

9 DESCRIPTION ANALOK ALUMINUM SLIDING WINDOW ANALOK ALUMINUM FOUR-PANEL SLIDNG WINDOW ANALOK ALUMINUM THREE-PANEL SLIDING WINDOW ANALOK ALUMINUM ONE PANEL WINDOW ANALOK ALUMINUM AWNING WINDOW
8 LOCATION LIVING AREA, DINING AREA, KITCHEN, MASTER'S BEDROOM, LIVING AREA LIVING AREA MAID'S QUATER, MASTER'S BEDROOM, BALCONY T&B
3

7 QUANTITY BEDROOMS, GUEST ROOMS,PARKING UTILITY, STORAGE 1 SET 1 SET 6 SETS 4 SETS
6 MARK 17 SETS W2 W3 W4 W5
5 W1
4
3
0.8

2
1
0

2 DETAIL OF STAIRS 3 SCHEDULE OF DOORS AND WINDOWS


A 6 SCALE 1:500 MTS A 6 SCALE 1:500 MTS

PROJECT TITLE SHEET CONTENTS SHEET NO.


CAVITE STATE UNIVERSITY BACTOL, RONEL L. ALL MEASUREMENT ARE TO BE VERIFIED ON SITE, ALL DISCREPANCIES ARE TO BE
IMMEDIATELY REPORTED TO ARCHITECT. MAIN STAIR PLAN

A6
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY

INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT DETAIL OF STAIRS
SCHEDULE OF DOORS AND WINDOWS
-REPUBLIC ACT NO. 9266
ARCH. KATHLEEN NUÑEZ BESCASER,uap
A B C D

10.6
A B C-A D E
4.5 2.35 3.75

16.6

C2F2 C2F2 C2F2 C3F3


1
3.2

3.2
1
FB-1 RB FB-1

C1F2 C1F2 C2F2


2-A C2F2

1.95

5.41

5.41
FB-5 FB-5
3.8

C1F2 C2F2
C2F2

3.1
C1F2 FB-2 RB FB-2
3 C2F2
C2F2 2
15.45

C1F2
2.05

RB RB RB RB

13.66

3.75
3.75
@10MM
TEMPERATURE
BARS @0.50 M
BOTHWAYS
(TYPICAL)
1.9

C1F1 C2F2 FB-3 FB-3


4 C2F2 3 RB
C1F2

7.2

4.5

4.5
4.5

FB-5 FB-5

C2F2 C2F2 C2F2 C2F2 FB-4 RB FB-4


5 C1F1
4

6 3.25 3.85 3.5


16.6 4.5 2.35 3.75

1 FOUNDATION PLAN
SCALE 1:100 MTS
2 SECOND FLOOR FRAMING PLAN
S 1 SCALE 1:100M
S 1

PROJECT TITLE SHEET CONTENTS SHEET NO.


CAVITE STATE UNIVERSITY BACTOL, RONEL L. ALL MEASUREMENT ARE TO BE VERIFIED ON SITE, ALL DISCREPANCIES ARE TO BE
IMMEDIATELY REPORTED TO ARCHITECT. FOUNDATION PLAN

S1
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY

INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT SECOND FLOOR FRAMING PLAN

-REPUBLIC ACT NO. 9266


ARCH. KATHLEEN NUÑEZ BESCASER,uap
GENERAL NOTES REINFORCING STEEL
1. GENERAL NOTES AND TYPICAL STRUCTURA DETAIL 1. SCHEDULE OF REINFORCING BARS
SHALL APPLY TO ALL DRAWING UNLESS OTHERWISE
SHOWN OR NOTED.
DIAMETER OF BARS GRADE ASTM
2. FEATURES OF CONSTRUCTION SHOWN ARE TYPICAL
AND SHALL GENERALLY THROUGHOUT FOR SIMILAR 12 AND SMALLER GRADE 33 (33 KSI) A615 / A615 M (DEFORMED)
CONDITIONS MODIFY TYPICAL DETAILS AS REQUIRED
TO MEET SPECIAL CONDITIONS. 16 AND LARGER GRADE 40 (40 KSI) A615 / A615 M (DEFORMED)

A B C-B D E
3. THE CONTRACTOR SHALL EXAMINE THE DRAWING 2. BARS SHALL BE CLEAN OF RUST, GREASE OR OTHER MATERIALS LIKELY YO
AND SHALL NOTIFY THE ARCHITECT/ENGINEER OF ANY
DESCRIPANCIES HE MAY FIND BEFORE PROCEEDING WITH IMPAIR BOND, ALL REINFORCING BAR BENDS SHALL BE MADE COLD.
THE WORK OR DURING CONSTRUCTION.

4. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO PROVIDE


3. IN GENERAL, BAR SPLICES SHALL BE MADE AT POINTS OF MINIMUM STRESS,
SPLICES SHALL BE SECURELY WIRED TOGETHER STAGGER SPLICES ATLEAST
17.65
ADEQUATE SHORING AND BRACING OF THE STRUCTURE FOR ALL
LOADS THAT MAY BE IMPOSSED DURING CONSTRUCTIONS.
600 MM WHENEVER POSSIBLE IN BEAMS AND SLABS SPLICE TOP BARS AT
MIDSPAN AND BOTTOM BARS NEAR SUPPORT SPLICE OF REINFORCEMENT SHALL 4.65 1.2 4.4 2.65 3.55 1.2
BE MADE ONLY AS REQUIRED OR PERMITTED ON DESIGN DRAWING IR AS
5. ALL MATERIALS AND WORKSMANSHIP SHALL CONFORM TO THE ALLOWED BY THE ACI CODE OR AS AUTHORIZED BY THE ENGINEER.
LATEST APPLICABLE STANDARDS OR SPECIFICATIONS ALL WORKS
SHALL CONFORM WITH THE BEST PRACTICE PREVAILING THE 4. BARS NOTED AS CONTINUOUS SHALL HAVE A MINIMUM SPLICE LENGTH OF 42
VARIOUS TRADES. BAR DIAMETERS BUT NOT LESS THAN 60 MM. UNLESS OTHERWISE NOTED.

5. REINFORCING SHALL BE SPLICED ONLY AS INDICATED ON THE DRAWINGS.


6. UNLESS SPECIFICALLY DETAILED ELSEWHERE WHERE
CONTRACTOR SHALL FOLLOW TYPICAL DETAILS AS SHOWN IN
THESE DRAWINGS.
6. MINIMUM CONCRETE COVER FOR REINFORCING SHALL BE: 1

1.79

1.79
7. DO NOT SCALE DRAWINGS, CALLED OUT DIMENSIONS
AND STANDARD CODE REQUIREMENTS SHALL GOVERN ITEM COVER
OVER UNSCALED DRAWINGS.
CONCRETE CAST AGAINST EARTH 75 MM 2-B
8. SPECIAL NOTE: DIMENSIONS INDICATED ON THE STRUCTURAL EXPOSED TO EXTERIOR OF WEATHER 38 MM
DRAWINGS SHALL BE COORDINATED WITH THE ARCHITECTURAL
DRAWINGS. ARCHITECTURAL DRAWINGS SHALL BE USED TO FORMED SURFACE BELOW GRADE 50 MM
DEFINE DETAILED CONFIGURATIONS, ELEVATIONS, OPENINGS,

5.41

5.42
JOINTS, SLOPES, ETC. SLAB ON GRADE 50 MM

COLUMNS / BEAMS 38 MM

CONCRETE NOTES STRUCTURAL SLABS TOP & BOTTOM 25 MM

SCHEDULE OF STRUCTURAL CONCRETE @ 28 DAYS COMPRESSIVE CONCRETE

15.45
STRENGTH. 3
A. 210 KG/CM^2 (3000 PSI) TYPICAL CONCRETE DENSITY=2400 KG/CM^2 (150 PCF)
FORMWORKS

3.75
B. 175 KG/CM^2 (2500 PSI) MAX SLUMP (TYPICAL) = 100 MM (4 INCH)

3.95
1. INFORM ARCHITECT/ENGINEERS OF OTHER MISCELLANEOUS CONCRETE STRUCTURAL 1. FORMWORKS SHALL BE PROVIDED FOR ALL CONCRETE INDICATED UNLESS SECURED
ELEMENT NOT SHOWN ABOVE TO DETERMINE THEIR RESPECTIVE COMPRESSIVE STRENGTH OTHERWISE FORMS SHALL BE SET THRU TO LINE AND GRADE AND MAINTAINED
SO AS TO INSURE COMPLETED WORK WITHIN THE ALLOWABLE TOLERANCES
STRUCTURAL ELEMENTS CONCRETE AGGREGATES
SPECIFIED AND SHALL BE MORTAR TIGHT. 4
FOUNDATION 19 CM (3 4 INCH) 2. FORMS AND THEIR SUPPORTS SHALL BE DESIGNED SO AS NOT TO DAMAGE
PREVIOUSLY PLACED STRUCTURE.
SLAB ON GRADE 19 CM (3 4 INCH)

4.5
3. NO CONSTRUCTION LOAD SHALL BE SUPPORTED ON NOR ANY SHORING REMOVED

4.3
SUSPENDED SLAB 19 CM (3 4 INCH) FROM ANY PART OF THE STRUCTURE UNDER CONSTRUCTION EXCEPT WHEN THAT
PORTION OF THE STRUCTURE IN COMBINATION WITH THE REMAINING FORMING
MASONRY WALL FOOTING 19 CM (3 4 INCH) AND SHORING SYSTEM HAS SUFFICIENT STRENGTH TO SUPPORT SAFELY ITS
WEIGHT AND THE ADDITIONAL IMPOSED LOADS.
STAIRS 19 CM (3 4 INCH)
4. FORMS SHALL BE REMOVED IN SUCH MANNER AS NOT TO IMPAIR SAFETY 5

1.2
AND SERVICE ABILITY OF THE STRUCTURE.

CONSTRUCTION JOINTS ITEM COVER

1. ALL SURFACES OF CONSTRUCTION JOINTS SHALL BE ROUGHEN TO 6MM AMPLITUDE.


FOUNDATION 24 HOURS
1.8 1.2 2.85 4.5 2.35 3.75 1.2
COLUMNS / WALLS 14 DAYS
2. ALL CONSTRUCTION JOINTS SHALL BE CLEANED TO REMOVE DUST, CHIPS OR
OTHER FOREIGN MATTER PRIOR TO PLACING OF THE ADJACENT CONCRETE. SUSPENDED SLAB 14 DAYS

ARE IMPOSED

CONCRETE MASONRY BEAMS 14 DAYS


2 ROOF FRAMING PLAN
WALL NOTES S 2 SCALE 1:100 MTS

1. ALL NON LOAD BEARING TYPE BLOCKS SHALL HAVE A UNIT WEIGHT NOT TO EXCEED 80 PCF.

2.ALL CMU CELLS CONTAINING REINFORCEMENTS SHALL ONLY BE SOLIDLY FILLED


WITH GROUT, ALSO ALL CMU CELLS BELOW FINISHED GRADE SHALL BE SOLIDLY
FILLED WITH GROUT.

3. UNLESS OTHERWISE NOTED, SCLID GROUT SHALL MEAN ALL CESS WITH OR
WITHOUT REINFORCING BE GROUTED.

PROJECT TITLE SHEET CONTENTS SHEET NO.


CAVITE STATE UNIVERSITY BACTOL, RONEL L. ALL MEASUREMENT ARE TO BE VERIFIED ON SITE, ALL DISCREPANCIES ARE TO BE
IMMEDIATELY REPORTED TO ARCHITECT. GENERAL NOTES REINFORCING STEEL

S2
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY

INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT CONCRETE NOTES
CONSTRUCTION JOINTS
FORMWORKS

ARCH. KATHLEEN NUÑEZ BESCASER,uap


-REPUBLIC ACT NO. 9266 CONCRETE MASONRY WALL NOTES
TYPICAL BEAM

COLUMN SCHEDULE FOOTING SCHEDULE BEAM SCHEDULE


C1 C2 C3 REINFORCEMENTS DEPTH
SPACING OF
LENGTH WIDTH OF EXC. LENGTH WIDTH DEPTH
MARK QTY. (m) (m)
TOP AND BOTTOM PARALLEL TO
(m)
BEAM (m) (m) (m) STIRRUPS
SHORT SPAN LONG SPAN

F1 2 1.40 1.40 12-16 MM 7-16 MM 1.50 B-1 4.5 0.25 0.4 PROVIDE 10 MM DIAMETER STIRRUPS FOR SHORT SPAN
10 MM STIRRUPS 2 @ 50 MM, 2 @ 75 MM, 2 @ 100 MM,
STIRRUPS: 2 @ 0.05
2 @ 150 MM, REST @ 200 MM FROM FACE OF COLUMN

2@ 50MM, F2 21 1.60 1.60 10-16 MM 5-16 MM 1.50 B-1 2.35 0.25 0.4 5 @ 0.075
400

400

200
4@ 75MM, 5 @ 0.10 PROVIDE 10 MM DIAMETER STIRRUPS FOR 60 METER SPAN
2 @ 50 MM, 5 @ 75 MM, 5 @ 100 MM,
6@ 100MM 200 REST @ 0.20 MM O.C. 5 @ 150 MM, REST @ 200 MM FROM FACE OF COLUMN
REST AT F3 1 1.00 1.00 10-16 MM 5-16 MM 1.00 B-1 3.75 0.25 0.4
150 MM 200 250

4-12 MM
B-2 5.41 0.25 0.4
8-16 MM 8-16 MM
REBARS W/ REBARS W/ REBARS W/ LEGEND:

10MM TIES 10MM TIES 10MM TIES B-2 3.75 0.25 0.4 100 MM CONCRETE SLAB ON FILL
@ 200 MM O.C @ 200 MM O.C @ 200 MM O.C

B-2 4.5 0.25 0.4


100 MM CONCRETE SLAB ON FILL
WITH 10 MM @ 300 MM O.C. B.W.

FFL
NGL

COMPACTED SOIL

TOP OF REINFORCED SLAB


50 MM THICK GRAVEL FILL

TYPICAL WALL FOOTING


1.5

1.5

1.5
3 DETAIL OF SLAB ON FILL

1
TYPICAL FOOTING

BOTTOM FOOTING SCALE NTS


S 3
0.3

0.3

0.3

0.3
10 MM TIES W/ 10 MM TIES W/ 10 MM TIES W/ 10 MM TIES W/
# 16 G.I TIE WIRE # 16 G.I TIE WIRE # 16 G.I TIE WIRE # 16 G.I TIE WIRE

1.4 1.6 1.6 1

DETAILED SECTION OF TYPICAL FOOTING,


4 WALL FOOTING AND COLUMN AND BEAM
SCALE NTS
S 3
1.60

1.60
1.40

1.00
1.40 1.60 1.60 1.00

C1F1 C1F2 C2F2 C3F3

1 DETAILED SECTION OF FOUNDATION


S 3 SCALE NTS

CANTILEVER L1

2.00
L1/4 L1/4 L2/4 L2/4 WIDTH
B
BAR "C" EXTRA TOP BAR "C" EXTRA TOP
BAR "A" CONT. TOP BAR "E" STIFF BARS

TOP BARS

STIRRUPS
DEPTH

STIFF BARS
D

BAR "D" EXTRA TOP


BAR "D" EXTRA TOP
L1/5 BAR "B" CONT. TOP
L1/5 L2/5 L2/5
BAR "B" CONT. TOP BOTTOM BARS

SPACING OF STIRRUPS SPACING OF STIRRUPS

EXTERIOR SUPPORT EXTERIOR SPAN INTERIOR SUPPORT INTERIOR SUPPORT INTERIOR SUPPORT

1.2 1.7 1.7 1.7 1.7

2 TYPICAL RC BEAM ELEVATION 5 TRUSS DETAILS


SCALE NTS SCALE NTS
S 3 S 3

PROJECT TITLE SHEET CONTENTS SHEET NO.


CAVITE STATE UNIVERSITY BACTOL, RONEL L. ALL MEASUREMENT ARE TO BE VERIFIED ON SITE, ALL DISCREPANCIES ARE TO BE
IMMEDIATELY REPORTED TO ARCHITECT. COLUMN SCHEDULE DETAIL OF SLAB ON FILL

S3
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY

INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT
FOOTING SCHEDULE
BEAM SCHEDULE
TYPICAL RC BEAM ELEVATION

-REPUBLIC ACT NO. 9266


ARCH. KATHLEEN NUÑEZ BESCASER,uap
GENERAL NOTES
1. ALL ELECTRICAL INSTALLATION SHALL BE DONE IN
ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. THE
APPLICABLE PROVISION OF LATEST EDITION OF THE PHILIPPINE
ELECTRICAL CODE, THE NATIONAL BUILDING CODE, THE
CITY/MUNICIPAL ELECTRICIANS, AND THE NATIONAL POWER
CODE. 1 4
LPP 3
2. TYPE OF ELECTRICAL VOLTAGE SHALL BE 230V, 1 PHASE, 2
WIRE, 60Hz. S

3. METHOD OF WIRING SHALL BE IN PVC FOR BOTH EXPOSED S


AND EMBEDED WORK WITH PROPER FITTINGS AND SUPPORTS,
SERVICE ENTRANCE CONDUIT SHALL BE IN RIGID STEEL (RSC).
4. ALL WALL OUTLETS SHALL BE INSTALLED AT THE
FOLLOWING HEIGHT ABOVE FINISHED FLOOR LEVEL UNLESS
OTHERWISE SPECIFIED.
S
1.40mts. A. WALL SWITCHES
S
2
0.30mts. B. CONVENIECE OUTLET
S
1.60mts. C. PANEL BOARD S S S
S3W S
1.60mts. D. KWHR. METER
S S
1.60mts. E. A.C.U. OUTLETS
TO GROUND FLR
CEILING LIGHT

S3W
0.15mts. F. C.O. ABOVE COUNTER S

1.70mts. G. C.O. ON TOILET


TO 2ND FLR S3W

5. ALL MATERIALS AND EQUIPMENT SHALL BE BRAND NEW TO 2ND FLR S


S S S
AND APPROVE TYPE FOR BOTH LOCATION AND PURPOSE CEILING LIGHT
TO GROUND FLR
S3W

INTENDED.
6. ALL LIGHTINGS AND CONVENIENCE RECEPTACLE CIRCUIT S S
S
HOMERUNS SHALL BE WIRED NOT LESS THAN 3.50sq.mm.
COPPER INDICATORS UNLESS OTHERWISE INDICATED IN THE
PLAN.
S
7. ALL LIGHTINGS AND PANEL BOARDS SHALL BE IN CIRCUIT
BREAKER TYPE, FLUSH MOUNTED OR AS INDICATED IN THE
PLANS.
S
8. ALL OUTDOOR INSTALLATION SHALL BE WEATHERPROOF.
9. UNLESS OTHERWISE SPECIFIED, JUNCTION BOX AND UTILITY
BOX SHALL BE PROVIDED WHENEVER REQUIRED. ALTHOUGH
SUCH BOXES ARE NOT SHOWN IN THE PLANS.
10. ALL ELECTRICAL WORKS HEREIN SHALL BE DONE UNDER
THE DIRECT AND IMMEDIATE SUPERVISION OF A DULY
LICENSED ELECTRICAL ENGINEER.
1 GROUND FLOOR LIGHTING LAYOUT LPP 2 SECOND FLOOR LIGHTING LAYOUT
SCALE 1:100 MTS SCALE 1:100M
E 1 E 1

20A 20A
1 2

LEGENDS 3
20A 20A
4

40A 20A
INTEGRATED LED LIGHTING FIXTURE FLUSH WALL SWITCH
/CEILING LIGHT
S 5 6

DUPLEX COVENIENCE OUTLET, 20A 40A


GROUNDING TYPE (WALL MOUNTED) S3W THREE WAY SWITCH
7 8
WEATHERPROOF DUPLEX REFRIGERATOR OUTLET,
OUTLET,
WP
GROUNDING TYPE
REF GROUNDING TYPE 20A 30A
9 10
ACU
AIRCONDITIONING OUTLET POWER / LIGHTING PANEL
30A 20A
R RANGE OUTLET WM WASHING MACHINE OUTLET 11 12

CIRCUIT HOMERUNS WH WATER HEATER OUTLET


13 14
HO2 WATER PUMP OUTLET

3 SINGLE LINE DIAGRAM


SCALE NTS
E 2

PROJECT TITLE SHEET CONTENTS SHEET NO.


CAVITE STATE UNIVERSITY BACTOL, RONEL L. ALL MEASUREMENT ARE TO BE VERIFIED ON SITE, ALL DISCREPANCIES ARE TO BE
IMMEDIATELY REPORTED TO ARCHITECT. GENERAL NOTES SINGLE LINE DIAGRAM

E1
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY

INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT LEGENDS
GROUND FLOOR LIGHTING LAYOUT
-REPUBLIC ACT NO. 9266 SECOND FLOOR LIGHTING LAYOUT
ARCH. KATHLEEN NUÑEZ BESCASER,uap
11
WH HO2
R
LPP
10 LPP
6
AT
8 1ST FLR

7
12 WM
5

REF

WP

WP

WP 9

WP

WP
ACU

WP

1 GROUND FLOOR POWER LAYOUT 2 SECOND FLOOR POWER LAYOUT


SCALE 1:100 MTS SCALE 1:100M
E 1 E 1

CRT LOAD DESCRIPTION LTS CO OTHER VA PER AMP PER SIZE OF BRKS SIZE OF HOMERUN
NO. LOAD CIRCUIT CIRCUIT F P T WIRE CONDUIT

1 LED LAMP 11 1,100 5.00 50 2 20 2-3.5MM^2 20mm PVC

2 LED LAMP 10 1,000 4.55 50 2 20 2-3.5MM^2 20mm PVC

3 LED LAMP 9 900 4.09 50 2 20 2-3.5MM^2 20mm PVC

4 LED LAMP 9 900 4.09 50 2 20 2-3.5MM^2 20mm PVC

5 DUPLEX COVENIENCE OUTLET 13 2,340 10.64 50 2 20 2-3.5MM^2 20mm PVC

LEGENDS 6 DUPLEX COVENIENCE OUTLET 13 2,340 10.64 50 2 20 2-3.5MM^2 20mm PVC

7 REFRIGERATOR OUTLET 1 250 1.14 50 2 20 2-3.5MM^2 20mm PVC

INTEGRATED LED LIGHTING FIXTURE 8,000 2-8.0MM^2 25mm PVC


S FLUSH WALL SWITCH 8 RANGE 1 36.36 50 2 40
/CEILING LIGHT 1-5.5MM^2
DUPLEX COVENIENCE OUTLET,
S3W
9 AIRCONDITIONING OUTLET 1 1,750 8.00 50 2 20 2-3.5MM^2 20mm PVC
GROUNDING TYPE (WALL MOUNTED) THREE WAY SWITCH

WEATHERPROOF DUPLEX 10 WASHING MACHINE 1 5,000 22.73 50 2 30 2-3.5MM^2 20mm PVC


REFRIGERATOR OUTLET,
WP OUTLET, REF GROUNDING TYPE
GROUNDING TYPE
11 WATER HEATER 1 3,000 13.64 50 2 30 2-3.5MM^2 20mm PVC
ACU
AIRCONDITIONING OUTLET POWER / LIGHTING PANEL
12 WATER PUMP 1 2,300 10.45 50 2 20 2-3.5MM^2 20mm PVC
RANGE OUTLET WASHING MACHINE OUTLET
R WM
13 SPARE 1,500 6.82

CIRCUIT HOMERUNS WH WATER HEATER OUTLET 14 SPARE 1,500 6.82

HO2 WATER PUMP OUTLET D.F.= 80% 144.97 AMP


I= 144.97 X (80%) + 8(25%) = 117.97 AMP

3 SCHEDULE OF LOADS
SCALE NTS
E 2

PROJECT TITLE SHEET CONTENTS SHEET NO.


CAVITE STATE UNIVERSITY BACTOL, RONEL L. ALL MEASUREMENT ARE TO BE VERIFIED ON SITE, ALL DISCREPANCIES ARE TO BE
IMMEDIATELY REPORTED TO ARCHITECT. LEGENDS

E2
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY

INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT GROUND FLOOR POWER LAYOUT
SECOND FLOOR POWER LAYOUT
-REPUBLIC ACT NO. 9266 SCHEDULE OF LOADS
ARCH. KATHLEEN NUÑEZ BESCASER,uap
GENERAL NOTES
1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE 32MM
WH
GALVANIZED IRON PIPE
HO2
EXECUTED ACCORDING TO THE PROVISIONS OF THE
PHILLIPINES PLUMBING CODE, THE NATIONAL BUILDING
CODE AND THE RULES AND REGULATIONS OF THE CITY.
2. THE CONTRACTOR SHALL COORDINATE THE
DRAWINGS WITH OTHER RELATED DRAWINGS AND
SPECIFICATIONS. THE ARCHITECT SHALL BE
IMMEDIATELY NOTIFIED OF ANY DISCREPANCY FOUND
HEREIN.
3. ALL PIPES SHALL BE INSTALLED AS INDICATED, ANY
RELOCATION REQUIRED FOR PROPER EXECUTION OF 20MM PVC PIPE (COLD)

OTHER TRADES SHALL BE WITH PRIOR APPROVAL OF


THE ARCHITECT.
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO
THE ACTUAL LOCATION DEPTH AND INVERT ELEVATION
OF ALL EXISTING PIPES AND STRUCTURES AS VERIFIED
BY THE CONTRACTOR.
5. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL COLD WATER LINE PIPE
RISER TO GROUND FLOOR
MAINTAIN A 2% MINIMUM UNLESS OTHERWISE 20MM PVC PIPE (COLD)

SPECIFIED.
6. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE
IN ACCORDANCE WITH THE MANUFACTURERS
SPECIFICATIONS.
7. THE CONTRACTOR SHALL VERIFY ALL EXISTING 20MM PVC PIPE (COLD)
UTILITIES AT THE SITE AND COORDINATE THE WORKS
WITH SEWER LINE EFFLUENT DISPOSAL POINT AND
WATERLINE SERVICE CONNECTING POINT.
8. ALL PIPES SHALL BE SIZED IN MILLIMETERS AND ALL 32MM GALVANIZED IRON PIPE

DIMENSIONS SHALL BE IN METERS UNLESS OTHERWISE


SPECIFIED.
9. ALL PIPES IMMEDIATELY BEFORE FIXTURES SHALL BE
GALVANIZED IRON PIPES SCHEDULE 40.
32MM GALVANIZED IRON PIPE

2 SECOND FLOOR WATERLINE LAYOUT


SCALE 1:100 MTS
P 1

TO MAIN WATER LINE

LEGENDS 1 GROUND FLOOR WATERLINE LAYOUT


P 1 SCALE 1:100 MTS
0.50 0.50
WATERCLOSET GATE VALVE

LAVATORY CHECK VALVE

KITCHEN SINK WATER METER

SHOWER WATER SUPPLY LINE


8" DRAINAGE 3 MM THK X 25 MM

0.1
SEWER PIPE LINE ANGULAR BAR
FLOOR DRAIN PIPE

0.50
HOSE BIBB PIPE RISER

0.1
FAUCET CATCH BASIN
10MM REINFORCEMENT
BARS @ 0.25 M O.C
WATER HEATER WATER PUMP PLAN SECTION
BIDET 3 DETAIL OF CATCH BASIN
SCALE NTS
P 1

PROJECT TITLE SHEET CONTENTS SHEET NO.


CAVITE STATE UNIVERSITY BACTOL, RONEL L. ALL MEASUREMENT ARE TO BE VERIFIED ON SITE, ALL DISCREPANCIES ARE TO BE
IMMEDIATELY REPORTED TO ARCHITECT.
GENERAL NOTES DETAIL OF CATCH BASIN

P1
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY

INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT LEGENDS
GROUND FLOOR WATERLINE LAYOUT
-REPUBLIC ACT NO. 9266 SECOND FLOOR WATERLINE LAYOUT
ARCH. KATHLEEN NUÑEZ BESCASER,uap
150 MM PVC DRAINAGE PIPES

50MM WASTE PIPE

50MM WASTE PIPE

PART OF SEPTIC
TANK
100MM SOIL PIPE

100MM SOIL PIPE FROM 2ND FLR

200MM DRAINAGE PIPE


TO STREET CANAL

50MM WASTE PIPE

200MM DRAINAGE
50MM WASTE PIPE
PIPE

50MM WASTE PIPE


100MM VERTICAL WASTE
PIPE TO GROUND FLR
100MM VERTICAL WASTE
PIPE FROM 2ND FLR

TO STREET
CANAL

2 SECOND FLOOR SANITARY LAYOUT


SCALE 1:100 MTS
P 1

1 GROUND FLOOR SANITARY LAYOUT


SCALE 1:100 MTS
P 1

2.45 0.6 6.9 0.6 3.2 0.6

LEGENDS 0.15 1.20 0.15 0.80 0.15

0.15
WATERCLOSET GATE VALVE

0.20

0.40 0.20
LAVATORY CHECK VALVE MANHOLE INLET AIR SPACE
2% SLOPE OUTLET

KITCHEN SINK WATER METER SCUM

0.30
INLET

SHOWER WATER SUPPLY LINE

2.00
1.20
1.50

8
1.30

1.20
FLOOR DRAIN SEWER PIPE LINE MANHOLE DIGESTIVE CHAMBER LEACHING
CHAMBER
HOSE BIBB PIPE RISER OUTLET
MANHOLE

FAUCET CATCH BASIN

0.20

0.20
0.15

1.6 1.6 1.6


BIDET 12 MM BARS @ 0.30
O.C. BOTHWAY PLAN
12 MM VERT. BARS 12 MM VERT. BARS

SECTION

3 DETAIL OF SEPTIC TANK


SCALE NTS
P 2

PROJECT TITLE SHEET CONTENTS SHEET NO.


CAVITE STATE UNIVERSITY BACTOL, RONEL L. ALL MEASUREMENT ARE TO BE VERIFIED ON SITE, ALL DISCREPANCIES ARE TO BE
IMMEDIATELY REPORTED TO ARCHITECT. LEGENDS

P2
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY

INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT GROUND FLOOR SANITARY LAYOUT
SECOND FLOOR SANITARY LAYOUT
-REPUBLIC ACT NO. 9266 DETAIL OF SEPTIC TANK
ARCH. KATHLEEN NUÑEZ BESCASER,uap
32MM GALVANIZED IRON PIPE

WATER HEATER
COLD WATER LINE PIPE
32MM GALVANIZED IRON PIPE RISER TO GROUND FLOOR
WATER PUMP

20MM PVC PIPE (COLD)

20MM PVC PIPE (COLD)

TO MAIN WATER LINE

LEGENDS
WATERCLOSET GATE VALVE

LAVATORY CHECK VALVE

KITCHEN SINK WATER METER


1 ISOMETRIC WATERLINE LAYOUT
SHOWER WATER SUPPLY LINE P 3 SCALE 1:100 MTS

FLOOR DRAIN SEWER PIPE LINE

HOSE BIBB PIPE RISER

FAUCET CATCH BASIN

WATER HEATER WATER PUMP

BIDET

PROJECT TITLE SHEET CONTENTS SHEET NO.


CAVITE STATE UNIVERSITY BACTOL, RONEL L. ALL MEASUREMENT ARE TO BE VERIFIED ON SITE, ALL DISCREPANCIES ARE TO BE
IMMEDIATELY REPORTED TO ARCHITECT. DIAGRAM OF WATER LINE LAYOUT

P3
THIS DRAWING, ACTING AS AN INTRUMENT OF SERVICE, IS THE PROPERTY

INDANG, CAVITE
201810336
MAY 27, 2021
TWO-STOREY RESIDENTIAL HOUSE OF THE ARCHITECT AND CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT

-REPUBLIC ACT NO. 9266


ARCH. KATHLEEN NUÑEZ BESCASER,uap