Version 7.4.

PVsyst TRIALPVsyst - Simulation report


Standalone system

Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN "PID" PARQUE SDA


Variant: Nueva variante de simulación
Standalone system with batteries
System power: 2700 Wp

PVsyst TRIAL Localidad Usme - Colombia

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05

PVsyst TRIAL
with v7.4.0

Project summary
Geographical Site Situation Project settings
Localidad Usme Latitude 4.51 °N Albedo 0.20
Colombia Longitude -74.10 °W
Altitude 2835 m
Time zone UTC-5

Meteo data
Localidad Usme
NASA-SSE satellite data 1983-2005 - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 10 / 0 ° Constant over the year
Average 7.3 kWh/Day

System information
PV Array Battery pack
Nb. of modules 6 units Technology Lead-acid, sealed, Gel
Pnom total 2700 Wp Nb. of units 10 units
Voltage 24 V
Capacity 1250 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 369.62 kWh/year
Missing Energy
Excess (unused)
2305.10 kWh/year

Project and results summary


0.00 kWh/year
Specific production 137 kWh/kWp/year Perf. Ratio PR
Available solar energy 464.07 kWh/year

Table of contents
Solar Fraction SF
7.78 %
13.82 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
08/07/23 PVsyst Evaluation mode Page 2/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05

PVsyst TRIAL
with v7.4.0

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 10 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 7.3 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Custom parameters definition)
Unit Nom. Power 450 Wp
PV Array Characteristics

Generic
RSM-144-7-440-M
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
Bateria Gel 12V 250 Ah
Lead-acid, sealed, Gel
5 in parallel x 2 in series
Number of PV modules 6 units Discharging min. SOC 20.0 %
Nominal (STC) 2700 Wp Stored energy 24.0 kWh
Modules 6 Strings x 1 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 24 V
Pmpp 2450 Wp Nominal Capacity 1250 Ah (C10)
U mpp 37 V Temperature Average between fixed 25 °C
I mpp 66 A and External

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Series
-5.0 mV/°C/Elem.
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.90 / 0.75
4.4 / 4.1 V
SOC = 0.20 / 0.45
3.9 / 4.0 V

Total PV power
Nominal (STC) 2.70 kWp
Total 6 modules
Module area 13.0 m²

Array losses

PVsyst TRIAL
Thermal Loss factor DC wiring losses Serie Diode Loss
Module temperature according to irradiance Global array res. 9.4 mΩ Voltage drop 0.7 V
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC Loss Fraction 1.7 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module Quality Loss Module mismatch losses Strings Mismatch loss


Loss Fraction -0.8 % Loss Fraction 0.0 % at MPP Loss Fraction 0.2 %

IAM loss factor


Incidence effect (IAM): Fresnel, AR coating, n(glass)=1.526, n(AR)=1.290

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.999 0.987 0.962 0.892 0.816 0.681 0.440 0.000

PVsyst TRIAL
08/07/23 PVsyst Evaluation mode Page 3/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05

PVsyst TRIAL
with v7.4.0

Detailed User's needs


Daily household consumers, Constant over the year, average = 7.3 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
Luminarias Led 2x18W 18 36/lamp 8.0 5184
Tomas 120V 5 100/app 4.0 2000
Stand-by consumers 24.0 144
Total daily energy 7328

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
08/07/23 PVsyst Evaluation mode Page 4/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05

PVsyst TRIAL
with v7.4.0

Main results
System Production
Useful energy from solar 369.62 kWh/year Perf. Ratio PR 7.78 %
Available solar energy 464.07 kWh/year Solar Fraction SF 13.82 %
Excess (unused) 0.00 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 86.7 % Cycles SOW 94.4 %
Missing Energy 2305.10 kWh/year Static SOW 82.6 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
150.7
135.2
152.2
139.5
GlobEff
kWh/m²
157.6
138.4
149.8
131.8
E_Avail
kWh
42.71
37.53
40.61
35.77
EUnused
kWh
0.000
0.000
0.000
0.000
E_Miss
kWh
192.0
175.5
194.4
191.7
E_User
kWh
35.22
29.69
32.72
28.16
E_Load
kWh
227.2
205.2
227.2
219.8
SolFrac
ratio
0.155
0.145
0.144
0.128
May 146.3 133.7 36.29 0.000 199.2 28.00 227.2 0.123
June 144.9 129.1 35.07 0.000 192.0 27.79 219.8 0.126
July 155.0 139.3 37.82 0.000 197.0 30.17 227.2 0.133
August 157.2 145.9 39.56 0.000 194.1 33.06 227.2 0.146
September 150.9 145.5 39.44 0.000 188.9 30.98 219.8 0.141
October 145.7 146.8 39.82 0.000 196.7 30.50 227.2 0.134
November 138.0 142.5 38.67 0.000 189.1 30.73 219.8 0.140

PVsyst TRIAL
December 142.6 150.3 40.77 0.000 194.6 32.60 227.2 0.143
Year 1758.2 1710.8 464.07 0.000 2305.1 369.62 2674.7 0.138

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
08/07/23 PVsyst Evaluation mode Page 5/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05

PVsyst TRIAL
with v7.4.0

Loss diagram
1758 kWh/m² Global horizontal irradiation
+0.0% Global incident in coll. plane

-2.71% IAM factor on global

1711 kWh/m² * 13 m² coll. Effective irradiation on collectors

efficiency at STC = 20.75% PV conversion

4621 kWh Array nominal energy (at STC effic.)

PVsyst TRIAL
-0.82% PV loss due to irradiance level

-8.33% PV loss due to temperature

+0.75% Module quality loss

-0.15% Mismatch loss, modules and strings

-2.94% Ohmic wiring loss

-88.68% Loss with respect to the MPP running

PVsyst TRIAL
Missing energy

86.18% 464 kWh


0.00% Unused energy (battery full)
Effective energy at the output of the array
Direct
Stored
use Battery Storage
16.6%
83.4%
-0.40% Battery Stored Energy balance
-19.89% Battery efficiency loss
-2.95% Charge/Disch. Current Efficiency Loss
0.00% Gassing Current (electrolyte dissociation)
-0.34% Battery Self-discharge Current

PVsyst TRIAL
2305 kWh
370 kWh Energy supplied to the user

2675 kWh Energy need of the user (Load)

PVsyst TRIAL
08/07/23 PVsyst Evaluation mode Page 6/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05

PVsyst TRIAL
with v7.4.0

Predef. graphs
Distribución de irradiación incidente

PVsyst TRIAL

PVsyst TRIAL Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL
08/07/23 PVsyst Evaluation mode Page 7/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05

PVsyst TRIAL
with v7.4.0

Predef. graphs
Energía diaria a la salida del conjunto

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
08/07/23 PVsyst Evaluation mode Page 8/8