PVsyst TRIAL
PVsyst TRIAL
Author
PVsyst TRIAL
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05
PVsyst TRIAL
with v7.4.0
Project summary
Geographical Site Situation Project settings
Localidad Usme Latitude 4.51 °N Albedo 0.20
Colombia Longitude -74.10 °W
Altitude 2835 m
Time zone UTC-5
Meteo data
Localidad Usme
NASA-SSE satellite data 1983-2005 - Sintético
System summary
PVsyst TRIAL
Standalone system Standalone system with batteries
System information
PV Array Battery pack
Nb. of modules 6 units Technology Lead-acid, sealed, Gel
Pnom total 2700 Wp Nb. of units 10 units
Voltage 24 V
Capacity 1250 Ah
Results summary
PVsyst TRIAL
Useful energy from solar 369.62 kWh/year
Missing Energy
Excess (unused)
2305.10 kWh/year
Table of contents
Solar Fraction SF
7.78 %
13.82 %
2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7
PVsyst TRIAL
PVsyst TRIAL
08/07/23 PVsyst Evaluation mode Page 2/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05
PVsyst TRIAL
with v7.4.0
General parameters
Standalone system Standalone system with batteries
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 10 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
User's needs
Daily household consumers
Constant over the year
Average 7.3 kWh/Day
PVsyst TRIAL
PV module
Manufacturer
Model
(Custom parameters definition)
Unit Nom. Power 450 Wp
PV Array Characteristics
Generic
RSM-144-7-440-M
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
Bateria Gel 12V 250 Ah
Lead-acid, sealed, Gel
5 in parallel x 2 in series
Number of PV modules 6 units Discharging min. SOC 20.0 %
Nominal (STC) 2700 Wp Stored energy 24.0 kWh
Modules 6 Strings x 1 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 24 V
Pmpp 2450 Wp Nominal Capacity 1250 Ah (C10)
U mpp 37 V Temperature Average between fixed 25 °C
I mpp 66 A and External
PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Series
-5.0 mV/°C/Elem.
Battery Management control
Threshold commands as
Charging
approx.
Discharging
approx.
SOC calculation
SOC = 0.90 / 0.75
4.4 / 4.1 V
SOC = 0.20 / 0.45
3.9 / 4.0 V
Total PV power
Nominal (STC) 2.70 kWp
Total 6 modules
Module area 13.0 m²
Array losses
PVsyst TRIAL
Thermal Loss factor DC wiring losses Serie Diode Loss
Module temperature according to irradiance Global array res. 9.4 mΩ Voltage drop 0.7 V
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC Loss Fraction 1.7 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst TRIAL
08/07/23 PVsyst Evaluation mode Page 3/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05
PVsyst TRIAL
with v7.4.0
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
08/07/23 PVsyst Evaluation mode Page 4/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05
PVsyst TRIAL
with v7.4.0
Main results
System Production
Useful energy from solar 369.62 kWh/year Perf. Ratio PR 7.78 %
Available solar energy 464.07 kWh/year Solar Fraction SF 13.82 %
Excess (unused) 0.00 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 86.7 % Cycles SOW 94.4 %
Missing Energy 2305.10 kWh/year Static SOW 82.6 %
PVsyst TRIAL
Balances and main results
PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
150.7
135.2
152.2
139.5
GlobEff
kWh/m²
157.6
138.4
149.8
131.8
E_Avail
kWh
42.71
37.53
40.61
35.77
EUnused
kWh
0.000
0.000
0.000
0.000
E_Miss
kWh
192.0
175.5
194.4
191.7
E_User
kWh
35.22
29.69
32.72
28.16
E_Load
kWh
227.2
205.2
227.2
219.8
SolFrac
ratio
0.155
0.145
0.144
0.128
May 146.3 133.7 36.29 0.000 199.2 28.00 227.2 0.123
June 144.9 129.1 35.07 0.000 192.0 27.79 219.8 0.126
July 155.0 139.3 37.82 0.000 197.0 30.17 227.2 0.133
August 157.2 145.9 39.56 0.000 194.1 33.06 227.2 0.146
September 150.9 145.5 39.44 0.000 188.9 30.98 219.8 0.141
October 145.7 146.8 39.82 0.000 196.7 30.50 227.2 0.134
November 138.0 142.5 38.67 0.000 189.1 30.73 219.8 0.140
PVsyst TRIAL
December 142.6 150.3 40.77 0.000 194.6 32.60 227.2 0.143
Year 1758.2 1710.8 464.07 0.000 2305.1 369.62 2674.7 0.138
Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy
PVsyst TRIAL
08/07/23 PVsyst Evaluation mode Page 5/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05
PVsyst TRIAL
with v7.4.0
Loss diagram
1758 kWh/m² Global horizontal irradiation
+0.0% Global incident in coll. plane
PVsyst TRIAL
-0.82% PV loss due to irradiance level
PVsyst TRIAL
Missing energy
PVsyst TRIAL
2305 kWh
370 kWh Energy supplied to the user
PVsyst TRIAL
08/07/23 PVsyst Evaluation mode Page 6/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05
PVsyst TRIAL
with v7.4.0
Predef. graphs
Distribución de irradiación incidente
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
08/07/23 PVsyst Evaluation mode Page 7/8
Project: PUNTO DE INFORMACIÓN Y DIVULGACIÓN
"PID" PARQUE SDA
PVsyst V7.4.0
Variant: Nueva variante de simulación
VC0, Simulation date:
08/07/23 10:05
PVsyst TRIAL
with v7.4.0
Predef. graphs
Energía diaria a la salida del conjunto
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
08/07/23 PVsyst Evaluation mode Page 8/8