Professional Documents
Culture Documents
Chapter 3 Problems
Chapter 3 Problems
1- Antenna with impedance of 40+j30Ω is to be matched to 100Ω lossless line with a short-
circuited shunt stub. Find the length and the position of the stub.
2- A 50Ω lossless line to be matched to 40-j60Ω load with a series single short-circuited stub,
calculate the stub length, its distance from the load, and the necessary stub reactance.
3- A microstrip antenna printed on Taconic substrate with dielectric constant εr= 3.5. If the
input impedance is 200Ω at the operating frequency of 2.4GHz, design a quarter wavelength
transformer to match it to 50Ω line.
4- A lossless short-circuited transmission line with Z0 = 50Ω. Using the Smith chart, find the
length of the line in order to have an input impedance of j60Ω.
answer: L=0.14λ.
5- A lossless open-circuited transmission line with Z0 = 50Ω. Using the Smith chart, find the
length of the line in order to have an input impedance of -j25Ω.
answer: L=0.09λ.