Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

www.edmi-meters.

com

Mk7C
ATLAS – Class 1 and Class 2

Single Phase Smart Meter


with Disconnect and Reconnect
Feature

Built on the advanced Atlas metering platform, the


Mk7C is a single phase meter with an integrated
100A UC3 compliant relay which allows
disconnection and reconnection of electrical
services remotely.

Key Features

Mk7C Factsheet | MKT-FS-032 Rev 03 Copyright © 2023 EDMI Limited


134mm (W)

Mk7C
ATLAS - Class 1 and Class 2
163.5mm (H) 51mm (D)

Single Phase Smart Meter with Disconnect


and Reconnect Feature
Weight: 1.1kg

Standards and Compliance Real-time Clock • Ability to store average/minimum/ ANSI Type 2 (ANSI C12.18)
maximum values for interval duration - RS-232 with modem power supply
• Class 1 and Class 2 • Accuracy (internal) within 15 seconds
per month at 23˚C (It supports most modems in the
• IEC 62052-11, 62052-21, 62052-31*,
62053-21, 62053-23 Time of Use market)
• AS 62052.11, 62052.21, 62053.21, Data Memory • Up to 8 rates plus unified rate - RS-485
 multi-drop (2 or 4-wire RJ45 or
62053.23 • 2.1 or 4.1*MB of non-volatile memory 2-wire screw terminal)
• Up to 32 separate import and export
• NMI M6 registers • Option for passive RS-232
• Daily, weekly, monthly, yearly and special • UDP/IP GPRS/PPP capable
Display
Measurement days • Compatible with MV-90™ and PLC
• Large 7 segment display
• 1 phase 2 wire • Up to 200 programmable special days
• Display digit size: 9.3mm x 4.35mm
• Up to 61 previous billing periods plus Protocol
• Up to 60 user-defined screens of any
Voltage billing totals • EDMI command line
meter parameter
• Nominal voltage: 220V - 240V • Block or rolling maximum demand • DLMS
• Definable enunciators
• Operating range: 176V - 276V • Time of maximum demand • MODBUS
• Display available without main power
• Withstand: Up to 290V • Energy, pulsing inputs
• Burden: IEC 62053-61 compliant
Calendar
Current Measured Values • Supports Daylight Saving time Software
• WC range: 5/100A, 10/100A • Supports Gregorian or Persian calendars • EDMI EziView software available for
• 1 element 4 quadrants
• WC limit: 7000A for 3 cycles meter programming and reading
• Import/Export/Absolute Wh, varh and
• Burden: <0.5VA/phase (Windows® compatible)
VAh Tamper Detection and Alarms
• Fundamental Wh • EDMI MultiDrive software available for
• Provision for sealing with conventional
large scale AMI and AMR solutions
Frequency • W, var, VA, Vrms, Irms wire or plastic seals
(Windows® compatible)
• 45Hz - 65Hz • Power factor, frequency, phasor angles • Reverse current detection
• Supported by many popular third-party
• Supports ripple control/AFLC • Advanced tamper detection and logging
multi-vendor AMR systems
Relay • Pre-programmed alarms for meter self-
• Supports Function Based Setup
check
• 100A IEC 62055-31 Annex C UC3 Power Quality Indication
• *Relay fault detection • Alarms trigger LEDs, enunciators, relay
• Total Harmonic Distortion (THD)
• Enhanced relay switching time ≤10s outputs or communications event
• Option for live waveform display
• May be ordered without a disconnect • Alarms are stored in event logs
• Sag/Swell Environmental
relay • Option for fixed-threshold magnetic
- 5 Cycle resolution • Specified operating range:
tamper detection
-R
 ecords time/date/phase/duration/ -25˚C to +60˚C
Inputs/Outputs Configuration • *Option for high-sensitivity 3D magnetic
average and worst excursion • Limit range of operation:
• Up to 4 I/O total in 2 isolated groups tamper detection with configurable
- Programmable trigger levels threshold -40˚C to +70˚C
(maximum 1 relay output)
• Storage range limit:
• Options include: Passive/Active
inputs, S0/Relay outputs Load Survey/Profile Security -40˚C to +80˚C
• Passive input voltage: 5V, 12V, 48V • Over 5000 days storage (2 channels, • Relative humidity:
• Multi-level security (username and
• Active input voltage: 12V (common 30-minute intervals) password including encrypted log-in) Up to 75% mean, 95% non-condensing
ground) • Supports Advanced Demand for 30 days
• Up to 7 independent security levels
Management (ADM) with prioritised • Ingress protection: IP54
• S0 output: 27V, 27mA maximum • Up to 6 individual users
rules • Protective Class II
• Relay output: 240V, 2A • AES128 bit encryption
• AMI Ready • Surge Test: 5kV
• 2 Programmable LED indicators
• Programmable output pulse width: • Up to 32 channels and 4 independent • Impulse Test: 10kV
1ms to 100ms surveys
• Intervals programmable from 1 to 60
minutes
Communications
Battery
• Up to 3 independently working
• Internal battery • Energy, instantaneous readings,
communication ports:
pulsing inputs as channel sources
• Backup time: 10 years without power - Optical port: FLAG (IEC 62056-21) or
(Lithium Battery)

Specifications with * symbol available in manufacturing codes with prefix 7Cx3

EDMI Limited www.edmi-meters.com


(Headquarters)
47 Yishun Industrial Park A, Singapore 768724
Tel: +65 6756 2938 Fax: +65 6756 0125
Email: marketing@edmi-meters.com
techsupport@edmi-meters.com
Copyright © 2023 EDMI Limited. All Rights Reserved. All trademarks are the property of their respective holders. EDMI’s Policy is one of continuous product development and the right is reserved to modify specifications contained herein without notice.