Professional Documents
Culture Documents
WS Xref
WS Xref
IT
PL
M
O
LI
T
T
LI
O
M
PL
IT
PUMP ROOM
AREA=17.4 m²
Ø11/2"WSP Ø11/2"WSP
Ø11/2"WSP Ø2"LIFTING PIPE
F.H.C
W.C
UP UP
UP AS PER LAST
LIFT LOBBY STRUCTURAL APPROVAL
UP
W.C
LIFT-02 LIFT-01
Ø11/2"WSP Ø11/2"WSP
ELEC.ROOM OWNER:
SHOP-3
SHOP-4 ENTRANCE
AREA=52.3 m²
AREA=38.1 m² LOBBY
LOCATION: AL NAHYAN
PROJECT ID
CCTV-SECURITY B1M-2022-004027-P04-M01
Consultant:
PL
IT
PRINCIPAL CONSULTANT
M
O
LI
T
LI
T
O
M
PL
IT
UP
TEL: +97124436366, FAX: +97124436367
DEFENSE ROAD, ABU DHABI, U.A.E.
P.O. BOX 33848, ABU DHABI, U.A.E.
E.mail: info@basaltconsultant.com
Website: www.basaltconsultant.com
ENG.ANAS
DRAWING
ENG.ANAS
GENERAL
1. ALL DIMENSIONS ARE IN CENTIMETERS AND LEVELS IN CENTIMETERS UNLESS
OTHERWISE INDICATED.
2. THIS DRAWING SHOULD BE COORDINATED WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL APPROVED
DRAWINGS.
3. ALL EXISTING DIMENSIONS & LEVELS INDICATED ON DRAWINGS ARE TO BE
VERIFIED ON SITE.
4. CONTRACTOR TO SATISFY ITSELF WITH THE CONTENTS OF DRAWINGS AND IN
CASE OF ANY DISCREPANCY, IT SHALL BE BROUGHT TO THE ATTENTION OF
IT
PL
CONSULTANT PRIOR TO EXECUTION.
M
O
LI
T
T
LI
O
M
PL
IT
MALE TOILET
OFFICE-3 OFFICE-2 OFFICE-1
AREA 39.2 m² AREA 31.7 m² AREA 43.9 m²
Ø11/2"WSP
Ø11/2"WSP
3 2 1
Ø11/2"WSP
Ø11/2"WSP
FEMALE TOILET
O.D.F F.H.C
AS PER LAST
STRUCTURAL APPROVAL
LOBBY
UP
Ø11/2"WSP
LIFT-02 ELEC. LIFT-01
Ø11/2"WSP
PANTRY
OWNER:
OFFICE-4 OFFICE-5 OFFICE-6
AREA 29.9 m² AREA 41.2 m² AREA 42.5 m²
4 5 6
LOCATION: AL NAHYAN
PROJECT ID
B1M-2022-004027-P04-M01
Consultant:
IT
PL
M BASALT
LI
O
ENGINEERING CONSULTANCY
T
T
LI
O PRINCIPAL CONSULTANT
M
PL
IT
TEL: +97124436366, FAX: +97124436367
DEFENSE ROAD, ABU DHABI, U.A.E.
P.O. BOX 33848, ABU DHABI, U.A.E.
E.mail: info@basaltconsultant.com
Website: www.basaltconsultant.com
ENG.ANAS
DRAWING
ENG.ANAS
GENERAL
1. ALL DIMENSIONS ARE IN CENTIMETERS AND LEVELS IN CENTIMETERS UNLESS
OTHERWISE INDICATED.
2. THIS DRAWING SHOULD BE COORDINATED WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL APPROVED
DRAWINGS.
3. ALL EXISTING DIMENSIONS & LEVELS INDICATED ON DRAWINGS ARE TO BE
VERIFIED ON SITE.
IT
PL
4. CONTRACTOR TO SATISFY ITSELF WITH THE CONTENTS OF DRAWINGS AND IN
M
O
CASE OF ANY DISCREPANCY, IT SHALL BE BROUGHT TO THE ATTENTION OF
LI
T
CONSULTANT PRIOR TO EXECUTION.
T
LI
O
M
PL
IT
BEDROOM LIVING BEDROOM KITCHEN LIVING LIVING BEDROOM
area =16.7 m² area =19.5 m² area =12.4 m² 10.9 m² area =25.8 m² area =28.7 m² area =13.5 m²
Ø11/2"WSP BATH
BATH
3.7 m²
4.2 m² Ø11/2"WSP
F
F
Ø11/2"WSP
LOBBY Ø11/2"WSP LOBBY KITCHEN
KITCHEN BATH 6.6 m² area =7.1 m²
4.5 m²
7.3 m² 4.3 m²
F
O.D.F F.H.C
04 03 02
AS PER LAST
STRUCTURAL APPROVAL
LOBBY
UP
05 06 01
Ø11/2"WSP F
LIFT-02 ELEC. LIFT-01
Ø11/2"WSP
BATH LOBBY
4.3 m² KITCHEN
4.6 m² BATH area =7.1 m²
KITCHEN 5.0 m²
7.3 m²
LOBBY
F
7.2 sq.m
BATH
4.2 sq.m OWNER:
F
LOCATION: AL NAHYAN
PL
IT
Consultant:
M
O
LI
T
BASALT
LI
T
ENGINEERING CONSULTANCY
O
M
PL
IT
PRINCIPAL CONSULTANT
ENG.ANAS
DRAWING
ENG.ANAS
GENERAL
1. ALL DIMENSIONS ARE IN CENTIMETERS AND LEVELS IN CENTIMETERS UNLESS
OTHERWISE INDICATED.
2. THIS DRAWING SHOULD BE COORDINATED WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL APPROVED
DRAWINGS.
3. ALL EXISTING DIMENSIONS & LEVELS INDICATED ON DRAWINGS ARE TO BE
VERIFIED ON SITE.
4. CONTRACTOR TO SATISFY ITSELF WITH THE CONTENTS OF DRAWINGS AND IN
ROOF ROOF IT
PL
CASE OF ANY DISCREPANCY, IT SHALL BE BROUGHT TO THE ATTENTION OF
M
LI
CONSULTANT PRIOR TO EXECUTION.
O
T
T
LI
O
PL
M
IT
S.D
BATH
LIVING BEDROOM LIVING KITCHEN BEDROOM M.BEDROOM
AREA 21.1 m² AREA 15.7 m² AREA 20 m² AREA 9.7 m² AREA 12.1 m² AREA 12.1 m²
Ø11/2"WSP AREA 4.3 m²
Ø11/2"WSP
Ø2"LIFTING PIPE
F
Ø11/2"WSP
Ø11/2"WSP
BATH
BATH
AREA 4 m²
AREA 3 m²
O.D.F F.H.C
01
KITCHEN
AS PER LAST
AREA 6.3 m² STRUCTURAL APPROVAL
LOBBY
02
F
Ø11/2"WSP F
LIFT-02
Ø11/2"WSP
CAT LADDER KITCHEN
LIFT AREA 5.8 m²
ROOM
STORE
AREA 16.2 m² WATCHMAN
TEL.
ROOF ELEC. AREA 16.7 m²
ROOM
ROOM AREA 6.7 m² BATH
AREA 3.2 m² OWNER:
PROJECT ID
AC MACHINE LOUVERS AC MACHINE LOUVERS AC MACHINE LOUVERS B1M-2022-004027-P04-M01
PL
IT
ROOF Consultant:
M
O
LI
T
BASALT ENGINEERING CONSULTANCY
LI
T
O
M
PRINCIPAL CONSULTANT
PL
IT
TEL: +97124436366, FAX: +97124436367
DEFENSE ROAD, ABU DHABI, U.A.E.
P.O. BOX 33848, ABU DHABI, U.A.E.
E.mail: info@basaltconsultant.com
Website: www.basaltconsultant.com
ENG.ANAS
DRAWING
ENG.ANAS
GENERAL
1. ALL DIMENSIONS ARE IN CENTIMETERS AND LEVELS IN CENTIMETERS UNLESS
OTHERWISE INDICATED.
2. THIS DRAWING SHOULD BE COORDINATED WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL APPROVED
DRAWINGS.
3. ALL EXISTING DIMENSIONS & LEVELS INDICATED ON DRAWINGS ARE TO BE
VERIFIED ON SITE.
4. CONTRACTOR TO SATISFY ITSELF WITH THE CONTENTS OF DRAWINGS AND IN
CASE OF ANY DISCREPANCY, IT SHALL BE BROUGHT TO THE ATTENTION OF
CONSULTANT PRIOR TO EXECUTION.
IT
PL
ROOF
M
O
LI
T
T
LI
O
M
PL
IT
Ø11/2"WSP
Ø11/2"WSP
GV(NC)
DRAIN PIPE
Ø2"LIFTING PIPE
EACH
Ø11/2"WSP
Ø11/2"WSP
CAT LADDER
ROOF
OWNER:
PROJECT ID
AC MACHINE LOUVERS AC MACHINE LOUVERS AC MACHINE LOUVERS B1M-2022-004027-P04-M01
IT
PL
ROOF Consultant:
M
LI
O
T
T BASALT ENGINEERING CONSULTANCY
LI
O
M
PL PRINCIPAL CONSULTANT
IT
TEL: +97124436366, FAX: +97124436367
DEFENSE ROAD, ABU DHABI, U.A.E.
P.O. BOX 33848, ABU DHABI, U.A.E.
E.mail: info@basaltconsultant.com
Website: www.basaltconsultant.com
ENG.ANAS
DRAWING
ENG.ANAS
200
GV
60cm.
GENERAL
1. ALL DIMENSIONS ARE IN CENTIMETERS AND LEVELS IN CENTIMETERS UNLESS
WATER METER DETAILS OTHERWISE INDICATED.
2. THIS DRAWING SHOULD BE COORDINATED WITH OTHER RELEVANT
THREADED RUDE
ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL APPROVED
LOCK NUT
FFL LOCK NUT DRAWINGS.
3. ALL EXISTING DIMENSIONS & LEVELS INDICATED ON DRAWINGS ARE TO BE
LOCK NUT SLAB VERIFIED ON SITE.
THREADED RUDE
EXPANDING ANCHOR
STUD IN SLAB
4. CONTRACTOR TO SATISFY ITSELF WITH THE CONTENTS OF DRAWINGS AND IN
LOCK NUT
RUBBER LINED CASE OF ANY DISCREPANCY, IT SHALL BE BROUGHT TO THE ATTENTION OF
G.I CLAMP WALL CONSULTANT PRIOR TO EXECUTION.
EXPANDING ANCHOR
RUBBER LINED
G.I CLAMP
SLAB
COLD
SLEEVE
HOT
Ø25 CORREGATED
SLEEVE
Ø15 PEX PIPE Ø15 PEX PIPE
COLD
COLD
COLD
COLD
HOT
HOT
1/2"FEMALE ELBOW
1. R.C/SOLID BLOCK SUPPORT WITH PLASTER & EPOXY WITH BOX Ø15 PEX PIPE
2. ROOF WATER SUPPLY PIPE TO SPEC.
3. PIPE INSULATION TO SPEC. WATER LIFTING PUMP
4. FIXING CLAMP TO APPROVAL CONNECTION DETAILS
SHOWER / BATH TUB
HOSE BIB
WASH BASIN/
KITCHEN SINK
1/2"FEMALE ELBOW
PUMP SET WITH BOX WC
IV NRV FC FC ST IV TO BE DECIDED
TO BE DECIDED UPON SANITARY
UPON SANITARY FIXTURES APPROVAL
HOSE SPRAY FIXTURES APPROVAL
IV NRV FC FC ST IV FFL @ 0.00 FINISHED FLOOR LEVEL
BIDET
+1080.0
+1500.0
+1620.0
TOP ROOF
+120.0
+620.0
GROUND
PROTECTION COVER
FIRST
ROOF
WALL P.V.C SLEEVE WITH HINGES ON TOP
+30
ANGLE VALVE WALL
40x40mm FRAME
20Ø (PEX)
+15
FFL FFL
ROAD
F.F.L CW INLET CW OUTLET
CW OUTLET TO VILLAS FRONT VIEW
CW INLET FROM ADDC
SIDE VIEW
FLOOR SLAB
OWNER:
LOCATION: AL NAHYAN
PROJECT ID
B1M-2022-004027-P04-M01
Consultant:
ENG.ANAS
DRAWING
ENG.ANAS