7.00 Centrifugal Pump:- Supply of horizontal spindle horizontal split casing/end 2.

00 Sets
suctions (back pull out arrangement) Single/double/multistage centrifugal
pumps or combination of pumps in series/parellel of Mather & Platt/KSB/
Kirloskar make conforming to BIS 1520-1980) pump (Latest with up to to date
amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting
clear/raw water of under mentioned characteristics with bronze/Suitable alloy,
priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-
8 with cast iron casing coupled directly through a flexible coupling on a common
MS/Cast steel plate (base plate from the principal manufacturer of pumping set)
to coupling sliperring squirrel cage screen protected drip proof electric induction
motor of standard make such as Kirloskar/ NGEF/Cromption conforming to IS
12615-2018 and should be energy efficient IE2 complaint and TEFC type ( latest
with upto date ammendments) it should include the cost of bearings, nuts &
bolts,m painting etc. and shall be and suitable for operation on the date given
below:

8.00 SITE CONDITION Total


Head 174.33 mtrs
Discharge required 6.67 LPS each set.
No. of Pump required. 2.00 Nos sets (1 act as stand bye)
Length of R/main 925.00 mtrs.
Dia of R/main 100 mm dia
Location of the site of installation of machinery-The site is located at a distance
of 20 Km from Dharampur at Tasli Nallah by road & 0 KM on head load
The Altitude of :- The Altitude of place is 1002 mtrs above MSL
Type of Current:- AC three phase supply with
Rate Voltage:- 415+
Type of water and its Clear Water
Charactristics of water:-
a) Ambient Temperature
b) Turbidity NTU NTU
c) Hardness 260 Mg/Ltrs --
d) PH Value 7.5 --
e)Total Solid Mg/Lts)PH Value --
No of working hours. 16 Hours.
Limit of Pump (-) 15% (+) 10%
R. M.P. of Pumping RPM(or to be specified by the tenderer)
Test run 16 Hours continueously for 7 days.

9.00 Providing ICTP Main Switch with HRC fuses / Side handled operated Change 1.00 No.
over switch of L&T/Crompton/Standard/Havells make suitable capacity
Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments
immediately after the power meter of HPSEB

10.00 Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) 1.00 No.
switch board including angle iron post of suitable height and size ISA
40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of
mounting the following accessories with all internal connections:-

10.01 M.C.C.B. Havell/MDS/Standard of make of suitable capacity on incoming feeder 1.00 No.
with or without initial oil filling as the case may be with neutral linked under
voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments
with.
10.02 R.C.C.B. 100 Amp. of Havell/MDS/INDETEC make as per IS: 2516-1977 with 1.00 No.
upto date amendment which should have control box operating handle and
trip/reset bush button on/off indicators, re-indicating off spring condition of the
circuit breaker for over current protection. The circuit should be equipped with
10.03 The voltage monitor relay of L&T/AE make three phase with all protection and 1.00 No.
usual indicator and electric siren against single phasing low voltage, high
voltage, reverse phasing, over loading and phase voltage difference as per IS:
1248 (Part - II ) 1983
10.04 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable 1.00 No.
range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date
amendments.
10.05 Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 1.00 No.
(Latest edition) with up to date amendments of suitable rating.

10.06 Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( 1.00 No.
Latest edition) with up to date amendments of suitable rating.
10.07 Bus bar chamber with copper strips having three bars of suitable rating for full 1.00 Set
length equal to the width of the board for three live phases and suitable for
induced current, one copper bar of half the rating of full length for neutral phase
as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to
date amendments 100 Amp.

10.08 ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable 2.00 Nos
capacity as per IS: 4064 (Part - II) -1978 with up to date amendments.

10.09 Three phase indicator lamps complete with toggle switches for individual motors 1.00 Set
as per IS: 3452 ( P-I & II) with up to date amendments.

10.10 100mm Square type AC supply Ammeter of AE /L&T Rishab make of suitable 2.00 Nos
range (0-200) with selector switches and CTS operated as per IS:1248 (P-II)
1983 with up to date amendments.
10.11 Capacitor of L&T/Bajaj/Assian/Crompton make as per IS:2834 -1986 with up to 2.00 Nos
date amendments to raise the power factor at site to 0.95 for direct connections
to induction motor individually of suitable rating according to HP offered
including cables as per relevant ISI code (of Siemens/Glocter/IEC make) from
bus bar chamber to capacitor and also including ICTP switches of appropriate
range as per IS: 4064 (Part - II) 1978 with upto date amendments (Range to be
specified by the tenderer)

10.12 Providing suitable Star Delta starter of L&T/Havells/M.E.I make as per IS:8544 2.00 Nos
(Part - IV ) -1987 with up to date amendments for Squirrel Cage motor mounted
on panel board with magnetic type overload release and dashpot time lag, under
voltage release with or without initial oil filling as the case may be with single
phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.

10.13 Providing Hour run meter of recommended make as per IS: 722 (Latest edition) 2.00 Nos

11.00 Providing double flanged Cast iron sluice valve of Leader/Kirloskar make of 100 2.00 Nos
mm dia for the suction pipe and capable of withstanding the normal seat
pressure as per IS: 14846-2000 with up to date amendments. Class PN-1.6

12.00 Providing double flanged Cast steel sluice valve of Leader/Kirloskar make and 2.00 No.
size of 80 mm dia (ASA-300). and capable of with standing nominal seat
pressure of 52 kg/cm2 as per BS : 1414 / API - 600 .
13.00 Providing double flanged Cast steel reflux valve of Leader/Kirloskar make and 2.00 Nos
size of 80 mm dia. and capable of with standing nominal seat pressure of 52
kg/cm2 as per: BS : 1868 / API - 600 .
14.00 Providing double flanged Cast steel 100mm non return valve of Leader/ 1.00 Nos
Kirloskar make having bye pass arrangement for rising main and capable of with
standing normal sseat pressure of 52 kg/cm2 as per BS : 1868 / API - 600
. .

15.00 Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with 2.00 Nos
all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with
up to date amendments range 0 - 75 Kg/cm2
15.01 Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete 2.00 Nos
with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987
with up to date amendments range 0 - 760 mercury.
16.00 Installation of all the items appearing at Serial No. 9 to 15 as per the 1.00 Job
systematic drawing attached with the tender documents ( Drg.No.1)

17.00 Providing and fixing double flanged 125 mm piping work layout to be approved 1.00 Job
by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s)
offered and common header as per the rising main respectively complete with all
specials such as bends ,tees reducers/ increasers with companion flanges
matching with the relevant specifications of the accessories as indicated in the
drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as
per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983.
The pipes shall be as per relevant IS Code and to withstand 1.5 times total head
stipulated under item No.1.

17.01 The size of the various components to be as under:-


17.02 (i) Suction pipe 125 mm dia Min. length = 15 mtr.
17.03 (ii) Delivery pipe 80 mm dia -do- = 5 mtr.
17.04 (iii) Common Header 100 mm dia -do- = 10 mtr.

17.05 and will extend up to 5 meters from the outer wall of the pump house in the
direction to be jointed.
18.00 Providing and laying copper PVC insulated armoured power cable ( one cable
carrying all the three phases) of suitable size and capacity to and all other
electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date
amendments of Siemens/ IEC/ICC/GICO/Grandly/National make including all
other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable
glands etc. laid in pipes or trenches under floor.

18.01 (i) Motor side: 6 mm2 Min length = 20 mtrs. 20.00 Rmt

18.02 (ii) Supply side: 10 mm2 Min. length =10 mtrs. 10.00 Rmt

19.00 Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 1.00 Job
3mm thick electrode complete with material such as thimbles, nuts and bolts,
charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043
-1987 with up to date amendments for motors and other electrical equipments
and digging of pits etc. complete in all respect.

20.00 Supply of submersible pump of KSB /Calama/Johnston/SU/Kirloskar make 2.00 Set


conforming to BIS: 8034-1976 or latest suitable for lifting Water (latest with upto
date ammendments) fitted with bronze impellers/ suitable alloye. The pump
should be fitted with free flow impellers of bronze/suitable alloys directly coupled
to squirrell case electric induction motor of same make as (manufacturer
standard) conforming to BIS: 9283-1979 (latest with upto date ammendments )
and totally water prrof for submersible duty, isolated from the pump by
intermediate casing with double mechanical seal in oil chamber, grease packed
lubricated bearing & provided with stainless steel thrut bearing plate to with
stand vertical loads with minimum wear & tear. It should also be fitted with a
device to take up expansion of water with the heating of motor including water
level guard errection clamps, manufacturer cable clips & depth gauge etc. The
pump shall be suitable for operation on data given below:-

20.01 SITE CONDITION Total


Head 77.50 mtrs
Static Head 67.30 mtrs
Discharge required 20.22 LPS each set.
No. of Pump required. 2Nos 1set act as stand bye.
Location of the site of installation of machinery: The site is located at a distance
of 6 Km from Dharampur at Kandapattan-Bahri & 0.10 Km on head load
The Altitude of :- The Altitude of place is 592 mtrs above MSL
Type of Current:- AC three phase supply with
RateVoltage:- 415+/-10%
Type of water and its
Charactristics of water
a) Ambient
b) Turbidity NTU NTU
c) Hardness 260 Mg/Ltrs --
d) PH Value 5.00 HP --
e)Total Solid Mg/Lts)PH Value --
f) Other --
Static head in mtrs 67.30 mtrs.
Length of R/main 1580 mtrs
Dia of Rising main 200 mm dia.
No of working hours. 8 Hours.
Limit of Pump (-) 15% (+) 10% of
R. M.P. of Pumping 2900 RPM (or to be specified by the tenderer)
Test run 16 Hours continueously for 7 days.

21.00 Supply of star delta starter 63 AMP of reputed make i.e MEI/Kilburn or of 2.00 No.
approvrd make conforming to BIS 8544 -( Part - )1987 latest with upto date
amendments for squirrel cage induction motor (make to be specified by the
tenderers) mounted on panel board with magnetic type over load release and
gas-pots, time legs, under voltage release & initial oil filing suitable for 40 HP
motor.
22.00 Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed 1.00 No.
(Almirah type) switch board comprising and capable of mounting the following
accessories and with all internal electric connections, duly painted. The drawing
of panel board shall be subject to approval of Engineer-in-Charge.
22.01 Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make 2.00 No.
of 0-60 Amp capacity for above motor with selector switches conforming to IS-
1248 (Part - II)-1983 latest with upto date amendments.
22.02 Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of 1.00 No.
0 - 500 Volts range for above motor with selector switches conforming to IS-
1248 (Part - II)-1983 latest with upto date amendments.
22.03 ICTP switches with HRC fuses of Havells/L&T/standard /cromption make for 2.00 No.
required motor of 63 Amp capacity and conforming to IS: 4064 (part - II)1978
latest with upto date amendments.
22.04 Bus bar chamber having 3 copper bars of suitable rating for full length of 3 1.00 No.
phases and one bar of half the rating of full length for neutral conforming to IS:
8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date
amendmentsof suitable rating.
22.05 MCB/MCCB of suitable capacity of Havells/standard/MDS/Jyoti/Kilburn make to 1.00 No.
feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest
with upto date amendments with neutral linked under voltage release.

22.06 3 phase indicator lamps complete with toggle switches for individual motors 1.00 No.
conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts.

22.07 50 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant 2.00 No.
IS specifications.

23.00 Supply of Kirloskar /leader make cast steel double flanged ( swing check type) 2.00 No.
reflux valve having bye pass arrangement and 125 mm dia (ASA-150) and
capable of with standing nominal seat pressure of 21 kg/cm2 as per: BS : 1868 /
API - 600.

24.00 Providing and laying suitable size copper PVC insulated armoured power 3.5 1.00 Job
core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date
amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to
Bus bar switch and starter (one cable carrying all three phases) including all
other electrical equipment/accessories such as thimbles, flexible pipe solder,
nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type,
size and make will be subject to approval of HPSEB authorities. In case of non
acceptance by HPSEB authorities it shall have to be replaced by the tenderer.
Supply side Suitable sizes.

25.00 Supply of Leader /Kirloskar make cast steel double flanged (swing check type) 1.00 No.
reflux valve having bye pass arrangement and 200 mm dia (ASA-150). of rising
i.e. 200 mm for withstanding nominal seat pressure of 21.00 Kg/Cm 2 as per IS
:1868/API-600

26.00 Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with 1.00 Job
upto date amendments suitable for the pump sets offered from CB to motor
including all other electrical equipment / accessories such as thimbles, flexible
pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under
floor. The type, size and make will be subject to approval of HPSEB authorities &
in case of non acceptance by HPSEB authorities it shall have to be replaced by
tender.

27.00 Providing and laying double loop earthing with G.I. wire & G.I plate complete 1.00 Job
with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts,
digging of pits, GI. Wiring and aluminum strips of required capacity conforming
to BIS: 3043-1987 latest with upto date amendments for above motors and other
electrical equipment’s.

28.00 Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of 2.00 Nos
feibig make with all accessories such s stop cock, copper tubing etc, conforming
to IS: 3624-1987 latest with upto date amendments.
29.00 Providing and laying delivery pipe 125 mm dia. and common header 150 mm dia 1.00 Job
Heavy class as per IS:-1239-2004 Part-I jointed with MS flanges of table -5 as
per IS: 6392-1971 (upto a length of 10 mtrs ) including rappers, flanges, rubber
gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of
pump houses/well as per layout drawings approved by Engineer-in-Charge.
30.00 Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2.00 Nos
2834-1986 latest with upto date amendments L&T make to raise the prevailing
power factor at site to 0.95 for direct connection to induction motor individually
of suitable rating each including cable of siemens/Gloster/ICC make form bus
bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP
switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range
to be specified by the tendrerer).

31.00 Supply of suitable cable for water level guard 1.00 Job

32.00 Supply of supporting clamps. 1.00 Job

33.00 Supply of cable clips of required size. 1.00 Job

34.00 Erection of all equipment from Sr. No. 21 to 33 including cost of tees, bends, 1.00 Job
tapers and any other fittings required as per site conditions and as per direction
of Engineer-in-charge.