Electrical Amplifier Modules For Controlling Proportional Pressure Control Valves Without Electrical Position Feedback
Electrical Amplifier Modules For Controlling Proportional Pressure Control Valves Without Electrical Position Feedback
Electrical Amplifier Modules For Controlling Proportional Pressure Control Valves Without Electrical Position Feedback
05 1/8
Replaces: 02.03
controlling proportional pressure
control valves without electrical
position feedback
Types VT 11032 and VT 11165
Series 1X
F90025_d
Ordering code
VT 11 _ _ _ 1X *
Amplifier module for valve type DRE 4 K: Further details in clear text
Amplifier with control characteristic curve 1 (see page 4) = 032 1X = Series 11 bis 19
Amplifier with control characteristic curve 2 (see page 4) = 165 (11 to 19: unchanged technical data and
pin assignment)
Function
The amplifier modules are to be snapped onto top hat rail that The two amplifier types differ from each other in the effect of
are usually installed in control cabinets. The electrical connec- the command value attenuator. With type VT 11032 the attenu-
tion is made via a terminal strip. ation of the preselected command value increases with a rising
The amplifier modules include the electronics for controlling input voltage Ui2. With type VT 11165 the attenuation of the
two proportional solenoids. Depending on the command value preselected command value falls with an increasing input volta-
polarity, solenoid A or B is controlled. When valve “A” is cont- ge Ui2 (see control characteristic curve of the command value
rolled, LED “A” lights up and the status output for valve “A” is attenuator, page 4).
activated; when valve “B” is controlled, LED “B” lights up and The ramp time can be influenced by the intensity of the ramp
the status output for valve “B” is activated. time control voltage Ui3 (see control characteristic curve of the
The solenoid current is measured and compared with the com- ramp time, page 4).
mand value provided externally. Any differences between the The following settings can be made for each solenoid separa-
actual and the command value, caused e.g. by changes in the tely from outside using a trimming potentiometer:
solenoid temperature or supply voltage, are corrected. – Maximum current
Output stage “A” or output stage “B” can be enabled or disab- – Jump height of the output current at a command
led via enable input “A” (UEA) or “B” (UEB). value of 10 %
– Nominal time for up and down ramp up to approx. 8 s
Operating voltage 1
+ UB
(solenoid)
2
0V 1
RE 29764/07.05
6 A
Differential input (comm. value): 2 10
4 R13 R14 R3 R4 U
Reference potential U 11
5
I
0 to +10 V → B Ue1 U 4 5
0 to –10 V → A 2
VT 11032 and VT 11165
8
Enable B + UFB
16 Ramp comparator
1 output
8
Block circuit diagram / pin assignment VT 11032 and VT 11165
Operating voltage 7 + UM
+ UB2 DC 9 9
(amplifier module) + M0 Fault output
– UM
DC
H2
power
Technical Data (for applications outside these parameters, please consult us!)
– 10 –5 ~–1 ~+1 +5 + 10
Minimum command
100
Output current ISolenoid in mA
value attenuation
1 2
Maximum command
value attenuation
0
–2 0 +5 + 10
Control voltage Ui2 in V
Control characteristic curve of the ramp time (for VT 11032 and VT 11165)
~ 200
Ramp time tnom in %
~ 100
– 10 –5 0 +5 + 10
Note!
The control voltage of the ramp time (Ui3) is effectiv for all ramp times. The command value attenuator has an influence on the
command value of both. The diagrams only show a general trend of the effect of the individual control voltages, since their effect
also depends on the setting of command value potentiometers R1 to R4 and ramp time poteniometers R 11 R 14.
6/8 Bosch Rexroth AG Hydraulics VT 11032 and VT 11165 RE 29764/07.05
Status of multifunction
→ alight flashes
indicator „H2“
changes between
Status of fault
→ active active / inactive
output
synchronous with H2-indicator
If none on these 3 errors occurs, the fault output remains inactive and the multi-function indicator does not light up.
Status of LED „A“ → alight not alight not alight not alight
Status of LED „B“ → not alight not alight alight not alight
Terminal assignment
+U0 1 10
Operating voltage Solenoid
(solenoids) of valve A
0V 2 11
Enable A +UEA 3 12
Solenoid
of valve B
Reference
Differential input: 4 13
potential
0 to +10 V → B
0 to –10 V → A Ui1 5 14 Ui3
Ramp time
adjustment
Command value attenuation Ui2 6 15 GND
10 11 12 13 14 15 16 17 18
R3 R13
power
R4 R14
79
H2
R1 R12
B
R2 R11
A
1 2 3 4 5 6 7 8 9
85,5 65
Bosch Rexroth AG © This document, as well as the data, specifications and other information
Hydraulics set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
Zum Eisengießer 1 reproduced or given to third parties without its consent.
97816 Lohr am Main, Germany The data specified above only serve to describe the product. No state-
Telefon +49 (0) 93 52 / 18-0 ments concerning a certain condition or suitability for a certain applica-
Telefax +49 (0) 93 52 / 18-23 58 tion can be derived from our information. The information given does not
documentation@boschrexroth.de release the user from the obligation of own judgment and verification. It
www.boschrexroth.de must be remembered that our products are subject to a natural process of
wear and aging.