TRUNIONS
TRUNIONS
TRUNIONS
CHECK OF PERMISSIBLE LOAD RELATED TO THE WELD (full penetration weld assumed in this trunion):
WELD YIELD STRESS: K 220,00 Mpa
WELD THICKNESS: Z 11,00 mm
TRUNION IN. DIAMETER: di 146,30 mm
WELD SAFETY FACTOR: s 1,80
------------------------------------
WELD AREA: A = π/4 (d1^2 - di^2) 5435,90 mm²
WELD SECTION MODULUS: W = π/32 d1 (d1^4 - di^4) = 200772,04 mm³
PERMISSIBLE LOAD ON THE WELD: FL = 68742,02 N FL>Fle => OK!
Lift Angle θ° Flle(N) - PL* Flue (N) - PT* Flle / Fll + Flue / Flu CHECK ≤ 1
0,00 0,00 4783,93 0,08 OK!
10,00 846,85 4802,71 0,09 OK!
20,00 1699,11 4668,27 0,09 OK!
30,00 2531,43 4384,57 0,09 OK!
40,00 3322,28 3959,34 0,09 OK!
50,00 4056,14 3403,50 0,09 OK!
60,00 4728,24 2729,85 0,08 OK!
70,00 5356,93 1949,76 0,07 OK!
80,00 6026,72 1062,67 0,06 OK!
90,00 7125,00 0,00 0,05 OK!
* These values are entered divided by the impact factor, because DIN calculations inflict the impact factor
in the maximum loads (Fll, Flu etc)
RECOMMENDED SLINGS PER EN13414-1: 1.55 TONS WLL*
For lifting with trunions, ensure proper sling length so that skew angle among sling & vertical "β"
remains < 5° . Else, consider using spreader beam