Green Ambience Changer

POC & Success Case Study


Video Clip by NHK 2

Report from NHK, a National Broadcasting Corporation in Japan.


The reporter is explaining Panasonic Proof of Concept Test in Fujisawa City bus station.
Video Clip by NHK 3

Experiment from Panasonic Mist System


~ cooling ~ super fine mist particles ~ NO wet / discomfort /inconvenience
Wide Range of Applications 4

GAC mist system can be used for various applications


① Outdoor Cooling ② Humidifying ③ Dust-proofing

④ Staging effect ⑤ Scent distribution ⑥ Sanitization


GAC for Outdoor Cooling (POC in Singapore) 5

Jurong Lake Garden Installation

Singapore’s First UNESCO


Botanic Garden Installation World Heritage Site
Visitor interview at Jurong Lake Garden 6

Feedback from Visitor


~ cooling ~ no wet feeling ~ damage on make up ~ feeling good / enjoy fresh air
Visitor Survey at SBG and JLG 7

Overall, the mist system is appealing, and respondents see the opportunity for the mist
system to be implemented in many places such as waiting area and walkways
<Feature ofGAC Mistsystem>
our mist Cooling Technology
Ultra fine "Silky fine mist" 8

■spray Silky Fine Mist as small as 6-10μm.


■very small particle promote 「Evaporative cooling」, 「Pseudo sweating」 effect.
→『Silky fine mist realize efficient cooling effect & comfortability at the same time』
Cooling down air =「Evaporative cooling」
H2O‘
H2O‘ H2O‘ 熱 Evaporative cooling is…
熱 熱 Evaporate
Cooling down happens by heat leaving


using ambient
heat from ambient air when mist evaporate.



熱 熱 H2O

Hot Cool

H2O
H2O Realize efficient cooling

H2O as fine mist easily evaporate
Silky fine mist

Cooling down body =「Pseudo sweating」


Pseudo sweating is・・・
H2O‘ Evaporate
Cooling down happens by heat leaving
H2O‘ 熱 using body heat
Silky fine mist from the body when mist evaporate.

H2O H2O 熱
Fine mist is easy to evaporate and

熱 熱
Skin there is no discomfort of wet.
GAC Mist Cooling Effect 2019.9.20
BDC, AP Company 9

Sensible temp. (SET*) dropped by ▲3.9℃ (50cm from nozzle) with mist effect alone.
Measurement result of ①July 29 th ②August 21st ③September 3 rd

No Sunshade Sunshade only Sunshade+Mist


Cooling effect of Mist only
sunshade + mist (Calculate difference)

Sunshade Sunshade Sunshade

Natural wind Natural wind


Measurement
location Mist
Measuring point

1.36m
Ground 0.5m Pole 0.5m Pole Pole Pole

SET* ①34.0 ①29.7 ①26.1


(℃) ②31.6 ②27.9 ②23.5
Standard ③30.8 ③28.7 ③25.0 Avg. ▲7.3 Avg. ▲3.9
Effective ------------- ------------- -------------
Temperature
Av.32.1 Av.28.8 AV.24.9

①32.3 ①31.5 ①25.8


(Reference)
②31.5 ②31.2 ②24.8
Dry-bulb
temperature ③30.8 ③30.6 ③24.6 Avg. ▲6.5 Avg. ▲6.1
(℃) ----------- ------------ -----------
AV.31.5 AV 31.1 AV 25.1

Sensible temperature dropped by 7.3 ° C with the combination of sunshade and mist.
It is recommended to install walls to prevent mist from being washed away by natural wind.
GAC for Cooling Effect

10
GAC Mist for Outdoor Cooling Projects in Japan 11

◆JR Shinbashi Station ◆JR Shin Yokohama Station ◆Kobe Sannomiya

◆Katsushika district ◆Suita SST Commercial Facility Building (Osaka) ◆Suita SST Single-person apartment (Osaka)

To install handrails with mist


(heat mitigation & walking support)
GAC Mist for Outdoor Cooling Project in Thailand 12

The Sirimahannop
Asiatique the riverfront
2 Systems / 16 nozzles. Project finished 21-Jul-2020
• Customer background: Asset World Corporation (member of
TCC Group, Thailand Real Estate Developer)
• Purpose: solution to reduce outdoor ambience temperature
APEC Region
GAC Mist for Immerging Environment Creation Project in Thailand 13

The Melia Hotel


Koh Samui
2 Systems / 16 nozzles. Project finished 21-May-2021

• Customer background: Asset World Corporation


• Primary Purpose: Immerging Environment creation w/ design
• Secondary Purpose: Reduce outdoor ambience temperature
APEC Region
GAC Mist for Immerging Environment Creation Project in Thailand 14

Asian TeaHouse Rooftop Restaurant


Asiatique the riverfront
2 Systems / 16 nozzles. Currently under installation,
Project handover by Sept 2022

• Customer background: Asset World Corporation


• Primary Purpose: Immerging Environment creation w/ design
• Secondary Purpose: Reduce outdoor ambience temperature
APEC Region
GAC for Staging Effect

15
Gold Award Winning Expo with Panasonic GAC Mist System 16

BIE and Bureau Expo Dubai 2020


Japan Pavilion
20 Systems / 300 nozzles. Project Oct 2021 ~ Mar 2022
• An awards ceremony for the Official Participant Awards* was
held by the BIE and Bureau Expo Dubai 2020, Japan Pavilion
won the Gold Award in the Exhibition Design category
Expo 2020 Dubai

• Article source:
BIE Day Ceremony of Prizes and Awards at Expo 2020 Dubai (bie-paris.org)
Video source: https://youtu.be/fFyDYsmXEgo
GAC Mist for Staging Effect 17

(Museum / Tourist spots attraction / Event exhibition / Stage Performance / Concert / etc.)
◆Japan: Okayama
◆Thailand: Mankido
Tham Luang Museum ◆Thailand: Museum Project
• Combining mist • With Event company to
and projector to construct the experience
create 3D center Museum
expression that • Utilizing GAC misting + LED
further highlights projection
the mysterious • Period: Oct ~ Dec 22
space in cave
• Installed: 1 unit +
4 nozzles +
Projector (5,000
lm) × 1

◆Japan: Tokyo German Village ◆Miami & Macau: teamLab artwork


• Utilize the • Customer: Pace X
movement of light (U.S) Las Vegas
and the flowing Sands
mist created a • Installed: 2 units +
space that 30 nozzles (U.S)
stimulates various • Installed: 3 units +
sensibilities. 45 nozzles (Macau)
• Installed: 1 unit + 5 • Gallery is now open
nozzles in Miami
Spatial Design Service & System Configuration

18
GAC System Configuration
AE-GF021CE/DG spec sheet 19

Max length: 40m

~2m ~2m

// //
【Piping】 5 ~ 8 nozzles
Pressure tube×2
1:Water tube(Φ6㎜ ) Nozzle cover (optional)
2:Air tube(Φ16㎜ )
【Water】
Direct connection to city water or water tank
Water tube (Rc1/2)
【Electricity】
AE-GF021CE/DG Single phase 220V (Thailand, Indonesia)
Single phase 230V (Singapore, Malaysia)

Item Specification
Control box: AE-GF021CE (220V), AE-GF021DG (230V)
Model #
Nozzle unit: AE-GNG012 (Narrow), AE-GNE012 (Wide)
❖ Control box must be placed on the
foundation base. Size W610×D450×H855mm (Control box)
❖ Maximum height to nozzle unit: 3m Weight 119kg (Control box)
Single phase 220V 50Hz (Thailand, Indonesia) 0.96kW
Power consumption
230V 50Hz (Singapore, Malaysia) 0.96kW
front side
# of nozzles 5 ~ 8 nozzles
Rated mist volume 210mL/min
Noise 60dB (Control box)
Outdoor operation 〇(Waterproof:IPX4 )
H855 Running operation Manual ON/OFF or Timer operation by day of the week
Recommended
5 °C to 46 °C
temperature for usage
Operation condition
20%RH to 90%RH (no condensation)
W610 D450 relative humidity
GAC System Configuration
AE-GF041FZ spec sheet 20

AE-GF041FZ spec sheet (as of April 26, 2022)

AE-GF041FZ

*Additional device (3rd party) is required


Item Specifications
* Placed on the foundation base. Dimensions W900×D500×H957.5mm
* Maximum height to nozzle unit: 3m
Product weight 190kg
Required power capacity 3kVA or more
Rated power consumption 2.1kW(50Hz)
front side
Max spray volume 400mL/min
Outdoor operation 〇(Waterproof:IPX4 )
H957.5mm

Operation method Operation by control button or time switch


Spray volume adjustment Six-level adjustment through the water flow switch
Operation method Push buttons: START/STOP/PAUSE
Timer switch: START/STOP
Dry contact: START/STOP/PAUSE(w/ DC24V switch)
DMX link function* START/STOP/PAUSE/Flow rate change through pulse signals
w900mm d500mm
Ambient temperature: between +5 °C and 46 °C
Normal usage environment
Relative humidity: between 20% and 90%
Value-added Spatial Design Service 21

In-house Design Center can support spatial design based on the photos provided.
Spatial Design Proposals
For Example,

Actual photo

Bogor City Park Station


GAC systems opportunity in Indonesia Market 22

Outdoor / Rooftop restaurants Tourist Spots

Bali – Cliche Yet The Best

Borobudur Temple - World's Biggest Buddhist Sanctuary