Professional Documents
Culture Documents
Liquid Analysis Training MX Part 1 Summary
Liquid Analysis Training MX Part 1 Summary
Liquid Analysis Training MX Part 1 Summary
Summary
Bibiana González
Jan’2019
Emerson Confidential
Emerson Confidential 1
Agenda
Overview
Transmitters
Sensors
Applications
Q&A
Next Steps
Emerson Confidential 2
Liquid Analysis Sales
Emerson Confidential 3
Liquid Analytical Product Offering
pH Conductivity
Toroidal – 228 Insertion
High Temp – PERpH-X 3500
Premium Offering
Expandable to 2 Channels
Rosemount 56 Digital Communication
Modular Measurement Boards
Line Powered
Data/Event Logger
PID Control
Customer Value
Core Offering
Expandable to 2/3 Channels
Rosemount 1056/1057 Digital Communication
Modular Measurement Boards
Line Powered
Rosemount 1066
Conventional Offering
1 Channel
Digital Communication
Measurement Specific Boards
Loop Powered
Rosemount 5081
Emerson Confidential 6
Liquid Analysis Competitive Comparison
Emerson Confidential 7
pH Sensors
Emerson Confidential
Emerson Confidential 8
Complete pH Sensor
Seal
Seal
KCl Electrolyte
Solution
Ag/AgCl Ag/AgCl
Internal Wire Internal Wire
Buffered Fill
Reference Junction Solution
Glass Electrode
Emerson Confidential 9
Junction Types
• Reference Junctions
– Double Junction
• General purpose
applications
– Triple Junction
• Longer reference
pathway
– TUpH Junctions
• Helical reference
pathway which slows
down poisoning ions,
extending the life of
the sensor
• Large surface area
provides resistance
to coating
Emerson Confidential 10
pH Sensor
High Dirty and Coating Dirty and Coating Applications
General Purpose Steam Sterlizable
Purity Applications for Harsh Process Conditions
3900 385+ 389 3200HP 328A 3800 Hx338 Hx348 396 397 398 TF 396 3300HT 3400HT 3500P 372 RBI -
Non HF Sulfides
Glass Resistant Resistant
0-14 pH Range
ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü
Cracking Resistant
Glass
ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü
ü ü ü ü ü ü ü ü ü
Abrasion Resistant
ü ü ü ü ü ü ü ü ü
Coating Resistant
ü ü ü
Re-buildable
High Temperature and ü ü ü ü ü
Pressure
Retractable
ü ü ü ü ü
Emerson Confidential 11
Main Differentiators
Reference Junctions!! Remember this?
396P 3500P
385+ RBI
397 TF396
398
398R
Emerson Confidential 14
Retractable Options
Models in orange are retractable
3300HT 3400HT
The 396P, 397, and 398 are 396s with special body or mounting types
396 body type is SST
396 pH Sensor
Sensor Difference from 396
396P* Polypropylene body instead of SST
*(Highest Running 396 Sensor)
397 Polypropylene body in a Quik-Loc mounting assembly
Emerson Confidential 16
Left with Core and Special Sensors
General Purpose TUpH Coating PERpHx Rebuildable Special Applications
Resistant Sensors
3900 (Double) 396 3300HT 328A
389 (Triple) 3500P 372
Hx338+
RBI
TF396
Emerson Confidential 17
pH/ORP Sensor Product Offering
General Purpose
• Just Water? 3900/3900VP
• Chance for Poisoning or Contains Chemicals? 389/389VP/385+
Tough Applications
• High Temperature? PERpH-X Family:
3300HT/3300HTVP/3400HT/3400HTVP/3500P/3500VP
• Dirty? TUpH Family: 396/396VP, 396R/396RVP, 396P/396PVP, 397,
398/398VP, 398R/398RVP
Special Applications
• High Purity Water (< 5 µS/cm): 3900/3900VP with Low Flow Panel or
3200HP
• Non-Glass Requirement (ISFET): TF396
• Sanitary/Hygienic, Steam Sterilizable: Hx338, 3800/3800VP
• Hydrofluoric Acid (HF): 372
• Poisoning Chemicals or Contains Sulfides: RBI
Emerson Confidential 18
pH Sensor Slope
• A theoretically perfect pH sensor will have a slope value of 59.16
mV/pH at 25°C
• Slope describes how much mV charge is equivalent to a single pH unit
(sensitivity)
• Example:
• In a 4 pH buffer solution, a perfect sensor would output a 177 mV
signal
(7-X) x 59.16 mV, where X = pH of solution
(7-4) x 59.16 mV = 177 mV
Emerson Confidential 19
Calibration Diagnostics - Slope
• pH slope can be seen as an indication of the health of the pH glass
• Slope naturally decreases as the sensor ages
• Slope decreases faster with exposure to elevated temperatures
Emerson Confidential 20
ORP
Emerson Confidential 21
Why Measure ORP?
• ORP is best for determining the
endpoint in a reaction
• This graph shows that if ORP is
below zero then enough sulfite
ORP (mV) REDUCTION OF HOCl WITH SULFITE
800
Emerson Confidential 22
Conductivity
Emerson Confidential
Emerson Confidential 23
Conductivity Key Features
Four Flow Through
Contacting Sensors Toroidal Sensors
Electrode Sensors
140 141 142 150 400 402 403 404 410VP 225 226 228 222 242 245
Clean Liquid ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü
Coating
Processes
ü ü ü ü ü ü
High
Conductivity ü ü ü ü ü ü ü
Retractable ü ü ü
Hygienic/ ü ü ü ü
Sterilizable
High Solids
Tolerant
ü ü ü ü
Corrosion
Resistant
ü ü ü ü
VP ü ü ü ü
High
Temperature
ü ü ü
Emerson Confidential 24
Contacting Conductivity Sensors
Used for accurate low range conductivity
measurements in clean, non-corrosive liquid
applications 400
– Ultrapure to Surface Water
410VP 404
Emerson Confidential 25
Toroidal Conductivity Sensors
Sensor
Emerson Confidential 26
Amperometric
Amperometric Key Features
Steam
Sterilizable
Chlorine Ozone Dissolved Oxygen
Dissolved
Oxygen
498CL 499ACL 499AOZ 499ADO 499ATrDO Hx438
Free Chlorine Free Chlorine Trace DO ppm/ppb
Monochloramine
Total Chlorine
Temperature Compensated
Amperometric Measurement ü ü ü ü ü ü
Replaceable Membrane/Sensing
Cap ü ü ü ü ü ü
Minimal Flow Sensitivity ü
Tolerates Repeated CIP Cycles ü
Emerson Confidential 30
Rosemount TCL
• The TCL system is used for the
continuous determination of total
chlorine in water
• Components:
– Sample conditioning system
– One total chlorine sensor
– One transmitter (1056 or 56)
– One flow cell
– Overflow sampler
– Reagents sold separately
• Can be used with seawater
• Not for use in hazardous
environments
Emerson Confidential 31
Rosemount RDO
• Optical Dissolved Oxygen System
– Contains one sensor and one
transmitter
• Ideal for use in wastewater aeration
basins and ponds
• Oxygen sensor utilizes the
fluorescence quenching method
• Range: 0 to 20 ppm O2
• Operating Temperature: 0 to 50°C
• Maximum Pressure: 314 psig
Emerson Confidential 32
Turbidity
Objective 1 – Product Information
Clarity II Turbidimeter Description:
• Dual-sensor turbidimeter loop compliant with U.S. EPA 180.1 and ISO
7027 standard methods
• Loop components:
1. 4-wire Analyzer: 1056 / 56 Turbidity(ex.1056-27-XX)
• Based on T1055: languages, menus, backlit display
2. Optical sensor:
– Incandescent (EPA) lamp or LED (ISO) near-IR lamp
3. Measuring Chamber with a two-stage debubbler:
• Receiving sample: lower chamber, debubbler
• Measuring sample: upper chamber, allows pressurizing
4. Cable
Emerson Confidential 34
Clarity II
• Complete System
• Single or Dual Sensor Input
• Cable
• Molded Debubbler/Measuring Chamber
• USEPA Method 180.1 or ISO Method ISO 7027
• Resolution 0.001 NTU
• Ideal for Low Level Turbidity for DW Plant Needs
• Full Featured Analyzer with Seven Languages
• NEMA 4X (IP65) Analyzer
• Two 4-20 mA Outputs
• 4 programmable Alarms (-02 and -03 power supplies)
• Suitable for final treated Wastewater Discharge and
Industrial Process Water Applications
Emerson Confidential 35
Applications
Water Treatment
Remember: Follow the water
Raw water
Water treatment
Other uses
Emerson Confidential 37
Analytical in
Water Treatment
Follow the Water
Typical RO plant
What’s in it for us?
filter Na micron
softener dechlorination filter
NaHSO3
T Cl or ORP
pre-treated
water (RO
feedwater feedwater)
C
combined
pH C permeate permeate C: conductivity
reject Two-stage RO unit pH
C
ORP
permeate Cl: chlorine
T: turbidity
reject C
Emerson Confidential 39
Cooling Water
Emerson Confidential 40
Cooling water system
• What’s in it for us?
warm water return
Cl
pH
C
cooling tower
T
blowdown
makeup water
Emerson Confidential 41
Scale and Corrosion
Scale costs $$ in three major categories: Scale
Tube Scale in a Cooling
1) Decreased heat transfer Water Bundle
2) Decreased flow
3) Under deposit corrosion* Scale also decreases the
diameter of a tube impeding heat
Scale reduces the efficiency of heat exchangers transfer rates
including cooling and boiler heat exchangers Cold Side
• Scale is an insulator (think of it as a layer
of rock) Tube
• Scale decreases flow further decreasing Wall
heat transfer rates Hot Side
• Scale attracts more scale
Under deposit corrosion: Creates a super Tube
concentrated highly corrosive spot on a surface Wall
scale
under-deposit tube wall
corrosion heat
Under Deposit
Corrosion
Emerson Confidential 42
Boiler Water
Emerson Confidential 43
Boilers
• What’s in it for us?
pH C pH
C steam C pH
boiler DO *
condensate
returns
makeup water
C
Emerson Confidential 44
Poor pH Control Will Allow Corrosion
Basic Failures from Corrosion Pitting
• Localized corrosion (pitting) can rapidly
penetrate wall leading to a tube leak
• Uniform Corrosion reduces wall thickness to
the point where the tube can no longer hold
the pressure and the tube bursts Corrosion in a Tube
Water
• Temperature – Water can become more Thin Walled Tube Failure
boiler condensate
returns
precipitation of
soluble
contaminants
makeup water
corrosion products
&
contaminants
Emerson Confidential 46
Remember: Follow the water
Raw water
Water treatment
Other uses
Emerson Confidential 47
Drinking water treatment
Emerson Confidential 48
Drinking water filter plant
What’s in it for us?
coagulant/flocculant
screens
raw water settling basin
OZ mixer T
ozone
ozone contact filters
generator
chamber
backwash
pump
NaOCl
Cl Cl pH T
contact T
tank backwash reclaim pond
to screens
Emerson Confidential 49
Free chlorine: Model FCL
chlorine pH • Two versions
sensor sensor
– FCL-01 chlorine only
– FCL-02 chlorine with pH
correction
• Constant head flow
controller--no valves or
pressure regulators to
worry about
• Minimum flow about 11 lph
• Everything mounted on a
back plate
• Sensor cables pre-wired to
the analyzer
inlet drain
flow controller
inlet
drain flow controller
Emerson Confidential 51
Liquid Industrial
Applications
Leak Detection in
Heat Exchangers
Emerson Confidential 53
Measurements in Scrubbers
scrubbed • Scrubbers are used to remove
gas harmful or smelly gases from a
gas stream.
• A chemical reaction between the
objectionable gas and a scrubbing
scrubbing liquid removes the gas.
liquid • As the gas is scrubbed out, the
concentration of scrubbing liquid
decreases.
• Either pH or conductivity can be
gas to be
used to measure the
scrubbed
concentration.
Emerson Confidential 54
Oil and Gas Drilling
Sample conductivity trend
Oil drillers use various fluids to lubricate the
drills and bring up rock to the surface
Analyzing the fluids provides feedback on the
rock formation and can give advance notice
of when petroleum products will be
encountered.
(See ADS 2900-11 for more details)
Toroidal conductivity sensors (especially the
model 226) are ideal for this service because
they resist coating and plugging.
Model 226
installed in
mudlogging
system
Emerson Confidential 55
Refineries: The Crude Unit Overhead
Manual Amine
Valve Neutralizer
Reflux Tank
Distillation Accumulator
Tower
Water
Cooling Water
Sample
Crude
Oil Separator
pH
To Drain
• The lighter ends of the crude tower yield product with some acid water
content that must be neutralized before discharge.
• Most of the amine neutralizer is added at a constant flow rate because of
the time lag in the control system. (See ADS 2900-01 for more details)
Emerson Confidential 56
Industry Training
Pulp and Paper
pH ORP
pH
Head
Box
Waste pH
Treatment
Paper Machine
Bleach
C White
Liquor Towers
pH
Machine
Refiner
C Chest
Stock Preparation
Logs
Digester Black Chipper
C
Liquor
pH in Pulp and Paper
Locations:
• Pulp stock lines (pH control reduces the variability in the paper product)
• Process water (pH control reduces corrosion in the process piping)
• Wastewater (pH control reduces environmental damage caused by
effluent from bleaching and pulping operations.
Sensors:
The coating resistant model 396P, 396R recommended for
pulp
Chlorine Dioxide applications should use the model 398
PERpHX sensor is best for physical, temperature stress,
long life where maintenance is practiced.
Emerson Confidential 59
Conductivity in Pulp and Paper
Applications:
• Chemical Recovery (control of alkali strength)
• Steam/Power Plant (boiler protection)
Sensors:
The flow through model 242 is a good option for heavy
solids
The retractable model 228 sensor is most common
Emerson Confidential 60
Pharmaceutical Processing Solutions
• Water For Injection
– Demineralizers
– Reverse Osmosis
• Fermentation
– Steam Sterilizable
• Clean-In-Place
• Chemical Synthesis
• Waste Treatment
Emerson Confidential 61
Be a trusted advisor
• Your customers need you to recommend
improvements to their process
– You don’t need to be an expert on their process if you can ask
the right questions…
– but you will want to know more than they do about our
products!
• Sensor selection is the key!
– Nearly all sensors are compatible with all analyzers
– First… Select the best sensor for the customer’s process and
installation requirements
– Then… Select the instrument to be compatible with the
customer’s power, enclosure, area classification,
communication, and other needs.
Emerson Confidential 62
Comments / Questions
Thank you
Emerson Confidential 63