DATASHEET

Panther STEM Detector


The retractable double sensor array for fast,
low-damage, multimodal STEM imaging
The Thermo Scientific™ Panther STEM Detector is a segmented
Key benefits
dual sensor STEM imaging solution. It enables all state-of-the-
art imaging techniques with its 16 segments. It is optimized for Highest sensitivity and dynamic range. The optimized
simultaneous multimodal STEM imaging in combination with sensors enable imaging with single electron sensitivity for
spectral mapping applications. The high sensitivity and speed of beam-sensitive materials and simultaneous imaging and
the detector enable low-dose STEM imaging on beam-sensitive mapping acquisition with high electron doses
materials, dynamic STEM, and E/B field visualization via center (1.25 nA/segment at 300 kV).
of mass (COM) analysis.
Highest experimental flexibility with unique dual sensors
All-in-one STEM detector for all high tensions with segmented design. The two retractable sensors,
The Panther STEM Detector combines high speed and high one ring and one disk sensor—each with 8 segments—are
sensitivity down to single electron detection with optimized optimized in geometry for (i)DPC, BF, DF HAADF, and ABF
geometries for multiple STEM imaging techniques. The two imaging in combination with XEDS and EELS spectroscopy.
individual sensors with a total of 16 segments (Figure 1) are
mounted on two ultra-precise retraction mechanisms. A High linearity and homogeneous areal response function.
third mechanism provides flexibility for future user-specific A homogeneous and linear response of each sensor segment
experiments. (<1%) enables quantitative segment processing for accurate
COM analysis used for light element atomic imaging, (i)DPC
imaging, and in E/B field visualization.

Highest throughput with precise, double on-axis


retraction mechanism. The highly accurate retraction
mechanism with 60 µm precision allows for fast reproducible
mode switching and multimodal recording in combination
with post column filters and spectrometers.

Flexible software and hardware for new applications.


14000

12000
Chart Title
7 .00 E+ 04
6 .00 E+ 04
Chart Title
A third retractable detector position allows for the insertion
of user-made sensors. In combination with the optional
5 .00 E+ 04
10000 4 .00 E+ 04

3 .00 E+ 04
8000
2 .00 E+ 04

6000 1 .00 E+ 04

0 .00 E+ 00

Autoscripting engine, all standard segments can be user-


4000
1
20
39
58
77
96

1008
1027
115
134
153
172
191
210
229
248
267
286
305
324
343
362
381
400
419
438
457
476
495
514
533
552
571
590
609
628
647
666
685
704
723
742
761
780
799
818
837
856
875
894
913
932
951
970
989

Se ries 1 Se ries 2
2000

Figure 1. Scanned ring and disk sensor with profile proving the excellent
1
11
21
31
41
51
61
71
81
91
101
111
121
131
141
151
161
171
181
191
201
211
221
231
241
251
261
271
281
291
301
311
321
331
341
351
361
371
381
391
401
411
421
431
441
451
461
471
481
491
501

Series2

homogeneity of sensitivity across the segments as displayed by the red line.


defined readout and processed.

The standard readout modes of BF/DF/HAADF and (i)DPC with


all STEM parameters can be recorded in the Thermo Scientific™
Velox™ Graphical User Interface (Figure 2).
The collection angles of the sensors in mrad are displayed live in
the GUI and are stored in the metadata for quantitative analysis.
Up to four signals are displayed live in the GUI. For easy set-
up and reproducibility the sensitivity of the different sensors is
equalized by software and a graphical indication allows for easy
centering of the diffraction pattern.

Figure 2. The Velox GUI for insert/retraction of detectors and scattering


angle indication. Segmented STEM experiment setup becomes simple with
live, graphical centering indication of diffraction patterns.
Figure 3. iDPC STEM in high-contrast, low-dose imaging of MIL-101 with 2 Å resolution using only an electron dose of 45 e/ Å 2.

The new electronics allow for both low-dose experiments Multimodal readout for XEDS or EELS are optionally available via
(Figure 3) as well high-dose experiments for high signal-to-noise additional modules.
imaging or multimodal mapping applications (XEDS,EELS). The
For retrofits, please contact your sales and service
inner hole of the ring sensor is optimized for EELS acquisition.
representative to ensure compatibility.
The detector is operational across the entire high-tension range
of the tool (30–300 kV). All imaging specifications of the column
are guaranteed.

Panther Detector specifications


Operation voltage 30–300 kV
• 2 sensors
Detector parameters • Disk sensor diameter: 7.0 mm
• Ring sensor inner diameter: 4.13 mm; outer diameter: 21.0 mm
Detector total # segments 16
Sensitivity (200, 300 kV) Down to single electron sensitivity
Dynamic range (300 kV) 1.25 nA/segment; 10 nA/sensor
• Bright field, annular bright field
• Dark field, high annular dark field
Detection modes
• Differential phase contrast
• (i)DPC
Multimodal modes(optional) Combination of XEDS, 4D STEM, and EELS*
Non-Homogeneity of segments <1%
Non-linearity in dynamic range <1%
Mounting position On-axis, bottom-mounted, retractable
User interface Velox GUI
Computer platform Windows® 10, 64-bit
Additional retraction mechanism 3rd retraction mechanism with 6 signal feed-throughs for user specific applications**
Scripting Sensor signal readout/processing scriptable via Autoscripting environment (optional)
X-ray safety 2013/59/Euratom ionizing radiation directive
** Only in combination of detectors on the tool system tree.
** Sensor with electronics is user’s responsibility. Dimensions of mounting position can be shared with user.

Find out more at thermofisher.com/EM-Sales

For current certifications, visit thermofisher.com/certifications. © 2021 FEI Company. All rights reserved.
All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries unless otherwise specified. DS0360-EN-01-2021

You might also like