Professional Documents
Culture Documents
Omron F2LP-W
Omron F2LP-W
Ordering Information
■ SENSOR HEADS
Sensor head (unshielded) Minimum object size Part number
10 mm (0.39 in) 0.3 mm dia. x 0.5 mm steel rod F2LP-W10M
inside dia.
■ AMPLIFIER
Supply voltage 120/240 VAC, 50/60 Hz
Outputs Relay SPDT, 2 A, 250 VAC or 3 A, 30 VDC
DC solid-state 100 mA max.
Timer functions Normal or 40 ms OFF-delay
Part number F2LP-WK4-US
2
F2LP-W F2LP-W
Specifications
■ SENSORS
Part number F2LP-W10M F2LP-W20M F2LP-W50M F2LP-W75M F2LP-W100M
Sensor type Inductive
Body type Unshielded
Detectable object type Metal objects (Moving speed based on natural fall of objects from a height 10 cm above sensor)
Detecting distance 10 mm 20 mm 50 mm 75 mm 100 mm
inside diameter (0.39 in) (0.79 in) (1.97 in) (2.95 in) (3.94 in)
Minimum target Size 0.3 mm dia. 0.3 mm dia. 2.0 mm dia. 2.5 mm dia. 3.0 mm dia.
detecting x 0.5 mm (0.01 in x 1.0 mm (0.01 in (0.08 in) (0.1 in) (0.12 in)
distance dia. x 0.02 in) dia. x 0.04 in)
Type Steel rod Steel ball
Materials Case ABS Aluminum diecast
Sensing face ABS
Mounting Two through holes Two slots Four through holes or two slots
Cable 3 m high-frequency coaxial cable
Weight Approx. 80 g Approx. 220 g Approx. 430 g Approx. 800 g Approx. 1200 g
(2.82 oz) (7.76 oz) (15.17 oz) (28.22 oz) (42.33 oz)
Enclosure ratings UL —
NEMA 1, 2, 4, 12
IEC 144 IEC IP67
Approvals UL —
CSA —
Ambient temperature -25°C to 70 °C (-13°F to 158°F) with no icing
Vibration 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude
Shock Approx. 50 G
■ AMPLIFIER
Part number F2LP-WK4-US
Supply voltage 120/240 VAC ±15%, 50/60 Hz
Power (current) consumption 3 VA max.
Required sensors Interchangeable, any diameter F2LP-W ring sensor
Sensitivity Adjustable
Control ouput Relay SPDT, 2 A, 250 VAC or 3 A, 30 VDC
DC 100 mA max.
solid-state
Interval between Relay 75 ms max. (Minimum sensing objects can be detected at intervals specified. Larger objects need
objects longer intervals.)
DC Normal: 75 ms max.; OFF-delay: 125 ms max. (Minimum sensing objects can be detected at intervals
solid-state specified. Larger objects need longer intervals.)
Timer functions NORM (no timer), OFF-delay (transistor output, 40 ms), contact output compensation (40 ms)
Indicators POWER (red LED) and OPERATION (red LED)
Mounting Two threaded holes
Weight Approx. 300 g (10.58 oz)
Enclosure ratings UL 1
NEMA 1
IEC 144 IEC IP30
Ambient temperature -10°C to 55°C (14°F to 131°F) with no icing
Vibration 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude
Shock Approx. 10 G
3
F2LP-W F2LP-W
Operation
■ OUTPUT CIRCUIT DIAGRAM
DC Solid-State
Note: 1. The load can be connected as follows:
■ TIMING CHART
Note: 1. Relay outputs are ON when objects are sensed
Sensing
(when objects pass through the sensor head).
2. Each relay output is ON for 40 ms minimum
Output mode regardless of the position of the timer mode
selector.
Timer mode
Transistor output
Relay output
OPERATION
indicator
POWER indicator
■ CONNECTIONS
Note: 1. Terminal 7 (internal circuit 0 V) can be grounded by
grounding the sensor because this terminal is
connected to the metal case of the sensor. The
following terminals are insulated from one another:
sensor input terminals 7 and 8; transistor output
terminals 10 and 11; power supply terminals 1, 2
and 3; and relay output terminals 4, 5 and 6.
4
F2LP-W F2LP-W
Engineering Data
■ OBJECT SIZE VS. FALLING SPEED OF OBJECT
F2LP-W10M F2LP-W20M
F2LP-W50M F2LP-W75M
5
F2LP-W F2LP-W
Dimensions
Unit: mm (inch)
■ SENSOR HEADS
F2LP-W10M
10 Mounting holes
(0.39)
Two 3.5 dia. holes
15 (0.59)
37
(1.46)
20
(0.79)
5 (0.2)
Two 3.5
4.1 (0.16) dia. one- (0.14) dia. 15
conductor coaxial cable holes (0.59)
(length: 3m) 24 (0.94)
F2LP-W20M
16 Mounting holes
(0.63)
50 (1.97) Two 4.5 dia. holes
20 (0.79) dia. hole
30 (1.18)
25
(0.98)
F2LP-W50M
91 (3.58) Mounting holes
dia.
76 (2.99)
dia.
94 (3.7)
96 50 (1.97) dia.
(3.78)
5.5 (0.22) dia. one-conductor
coaxial cable (length: 3m)
50
(1.97)
10
(0.39) 74 (2.91)
110 (4.33)
8 (0.31)
6 (0.24)
26 (1.02)
8 (0.31) 94 (3.7)
10
(0.39)
6
F2LP-W F2LP-W
Unit: mm (inch)
F2LP-W75M
31.5 Mounting holes
Four 7 (0.28) (1.24)
10 130 (5.12) dia. holes
(0.39)
110 (4.33) 10
(0.39)
10
(0.39)
110
(4.33)
Four 7 (0.28)
110 75 dia. dia. holes
(4.33) (2.95)
155 110
(6.10) 5.5 (0.22) dia., (4.33)
one conductor
90 coaxial cable
(3.54) (length: 3m)
25
(0.98)
10
(0.39) 16.5
(0.65)
40
10
(0.39)
20
(0.79)
3.5 (0.14)
110 (4.33) radius
F2LP-W100M
Four 7 31.5 Mounting holes
(0.28) dia. (1.24)
170 (6.69) holes
140 (5.51) 10
(0.39)
140
(5.51)
Four 7 (0.28)
140 dia. holes
(5.51) 100 (3.94) dia.
185
(7.28) 5.5 (0.22)
dia., one 140
conductor (5.51)
coaxial
100 cable
(3.94) (length: 3m)
10 20 16.5
(0.39) (0.79) (0.65)
45
16
(0.63)
20
(0.79) 126 (4.96) 3.5 (0.14)
radius
7
F2LP-W F2LP-W
■ AMPLIFIER UNIT
F2LP-W100M
Mounting holes
75
(2.95)
66
(2.60)
6.75 74
(2.66) (2.91)
57.3
(2.26)
Nomenclature
Sensor selector:
F2LP-W10M, F2LP-W20M: Select dia. of 10
to 20
F2LP-W50M, F2LP-W75M, F2LP-W100M:
Select dia. of 50 to 100
POWER indicator:
Lit when power is on.
OPERATION indicator:
Lit when sensing objects. Compensation selector:
Select the position according to the
Sensitivity selector cable length. When cutting or extending
the cable, the length should be between
Timer mode selector (See Note 1.) 1.5 m and 10 m.
Frequency selector:
If induction or other mutual Note: 1. Timer mode selector:
interference is experienced NORM: No timer
when using more than one TIMER: OFF-delay transistor
Sensor, set the Sensor to output (40 ms)
different frequencies.
2. Output mode selector:
NO: Both transistor output and
relay output ON when sensing
objects
NC: Transistor output OFF and
relay output ON when sensing
objects.
Sensitivity adjustor
Precautions
■ EFFECTS OF SURROUNDING METALS
To prevent the sensor from being effected by any metal Part number Distance l Distance m
objects around it, keep metal objects away from the sensor by
at least the distances indicated in the drawing and table. F2LP-W10M 100 mm (3.94 in) 100 mm (3.94 in)
F2LP-W20M 100 mm (3.94 in) 20 mm (0.79 in)
F2LP-W50M 150 mm (5.91 in) 30 mm (1.18 in)
F2LP-W75M 200 mm (7.87 in) 40 mm (1.57 in)
F2LP-W100M 300 mm (11.81 in) 50 mm (1.97 in)
8
F2LP-W F2LP-W
F2LP-W10M F2LP-W75M
F2LP-W20M
F2LP-W50M F2LP-W100M
■ ADDITIONAL
Unit: mm (inch)
Do not use the sensor immediately after power is turned on.
The sensor needs an interval of 1 to 2 seconds after power is
on to function normally and sense objects.
To maintain noise resistance when connecting a sensor cable
to the Amplifier Unit terminals, always use a cable with a
conductor thickness of no more than 10 mm.