Basic datas

page 1 of 3
PCB 695649-2 Eprom: 695699-2

maschine type : client:

parameter function display standard data adjusted to

temperature probe 1 heating 1 on 1.1 63 °C


pre-wash heating 1 off 1.2 65 °C
lower ready point 1.3 48 °C
upper ready point 1.4 63 °C
temperature calibration 1.5

temperature probe 2 heating 2 on 2.1 68°C


wash tank 1 heating 2 off 2.2 70°C
lower ready point 2.3 58°C
upper ready point 2.4 70°C
temperature calibration 2.5

temperature probe 3 heating 3 on 3.1 68°C


wash tank 2 heating 3 off 3.2 70°C
lower ready point 3.3 58°C
upper ready point 3.4 70°C
temperature calibration 3.5

temperature probe 4 heating 4 on 4.1 68°C


wash tank 3 heating 4 off 4.2 70°C
lower ready point 4.3 58°C
upper ready point 4.4 70°C
temperature calibration 4.5

temperature probe 5 heating 5 on 5.1 85°C


(final rinse, booster) heating 5 off 5.2 87°C
lower ready point 5.3 70°C
upper ready point 5.4 87°C
temperature calibration 5.5
Basic datas
page 2 of 3
PCB 695649-2 Eprom: 695699-2

maschine type : client:

parameter function display standard data adjusted to

temperature probe 6 heating 6 on 6.1 73°C


drier heating 6 off 6.2 75°C
lower ready point 6.3 10°C
upper ready point 6.4 15°C
temperature calibration 6.5

timer 1a
off-delayed A 360
autotimer FTN
timer 1b off-delayed C 180
timer 1c off-delayed E 130

timer 2 fleeting F 1
transport

timer 3 dip-switch position H 30

off-delayed J1 = on FTX = 360


autotimer FTX
J2 = on CN = 30
autotimer rinse CNB
fleeting J1 = off electrical = 30
booster pre heating FTN J2 = on steam = 1

on-delayed J1 = on
J2 = off
off-delayed J1 = off
J2 = off

timer 4 off-delayed L 60
exhaust ventilation

timer 5 on-delayed P 3,5


booster refill

timer 6 off-delayed U 200


tankfilling
Basic datas
page 3 of 3
PCB 695649-2 Eprom: 695699-2

maschine type : client:

parameter function display standard data adjusted to

temperature inputs
temperature probe 1 pre-wash F1 1

temperature probe 2 F2 1

temperature probe 3 F3 1

temperature probe 4 last wash F4 1

temperature probe 5 final rinse F5 1

temperature probe 6 drier F6 1