1. Member Information
ㆍ Member : 200
2. Material
(1) Material Name : SM570
(2) : 58.02ksi
(3) : 29,733ksi
3. Length
(1) : 16.40ft
(2) : 16.40ft
(3) : 0.000ft
(4) : 1.000
(5) : 1.000
4. Section
(1) Shape : WF 450.400.18.28 ( Built Up )
(2) Section Property
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(1) Slenderness ratio of axial tension member ( L/r )
ㆍ L/r = 46.73 < 200.0 → O.K
(2)
ㆍ Resistance factor for tension : ø = 0.950
ㆍ = = 4,515kip ( Fracture resistance should be checked separately by the user )
ㆍ = 0.0776 < 1.000 → O.K
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(1) Web Proportions
ㆍ = 11.93 ≤ 150 → O.K
(2) Flange Proportions
ㆍ = 4.170 ≤ 12.0 → O.K
ㆍ = 16.42 ≥ D/6 = 2.349 → O.K
ㆍ = = 1.299 → O.K
ㆍ = 726in⁴
1/3
ㆍ = 726in⁴
ㆍ = 1.000 ≤ 10.0
(3) Flange Lateral bending Stress
ㆍ Web Load-Shedding Factor, Rb
ㆍ In constructibility
ㆍ = 1.000
ㆍ Limiting Unbraced Length, Lp
ㆍ = = 103in
ㆍ = = 4.548in
ㆍ Moment Gradient Modifier, Cb
ㆍ Calculation of Stress C6.4.10
ㆍ
ㆍ = 1.000
ㆍ = 5.305ksi
ㆍ = 4.741ksi
ㆍ Second-order elastic compression-flange Lateral bending stress ( 6.10.1.6 )
ㆍ = = 14.76ksi
ㆍ Check
ㆍ = 0.000in
ㆍ = = min( 432in, 432in ) = 432in
ㆍ
ㆍ = = 14.76ksi
ㆍ = = 34.81ksi → O.K
ㆍ Flexural Resistance based on Continuously Braced Tension Flange ( 6.10.8 )
ㆍ = = 58.02ksi → O.K
ㆍ Local Buckling Resistance based on Discretely Braced Compression Flange ( 6.10.8.2.2 )
ㆍ = = 4.170
ㆍ = = 8.603
ㆍ Web Load-Shedding Factor, Rb
ㆍ Because of the Composite Section satisfied the Section Proportions in Positive Flexure.
ㆍ = 1.000
ㆍ
ㆍ = = 58.02ksi
ㆍ Limiting Unbraced Length, Lp
ㆍ = = 103in
ㆍ = = 4.548in
ㆍ Lateral-Torsional Buckling Resistance based on Discretely Braced Compression Flange ( 6.10.8.2.2 )
ㆍ
ㆍ = = 58.02ksi
ㆍ = = 58.02ksi
ㆍ = = 58.02ksi → O.K
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
2/3
(2) Calculate interaction ratio of combined strength
ㆍ
ㆍ ComRat = = 0.287 < 1.000 → O.K
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(2)
ㆍ for webs of all other doubly/singly symmetric shapes and channels
ㆍ = = 27.78
ㆍ = 1.000
(3) Calculate shear strength in local-y direction
ㆍ = 64.64in²
ㆍ = = 2,175kip
ㆍ Resistance factor for shear : ø = 1.000
ㆍ = -21.64kip
ㆍ = 2,175kip
ㆍ = 0.00995 < 1.000 → O.K
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(2) Calculate the web shear coefficient ( C )
ㆍ for all other H-Shape members and channels
ㆍ k ( the web plate buckling coefficient ) = 5.000
ㆍ = = 56.70
ㆍ C = 1.000
(3) Calculate shear strength in local-z direction
ㆍ = 16.65in²
ㆍ = = 560kip
ㆍ Resistance factor for shear : ø = 1.000
ㆍ = -5.944kip
ㆍ = 560kip
ㆍ = 0.0106 < 1.000 → O.K
ㆍ
3/3