Professional Documents
Culture Documents
Fix206 1
Fix206 1
1. Member Information
ㆍ Member : 206
2. Material
(1) Material Name : SM520
(2) : 51.49ksi
(3) : 29,733ksi
3. Length
(1) : 16.40ft
(2) : 16.40ft
(3) : 0.000ft
(4) : 1.000
(5) : 1.000
4. Section
(1) Shape : TRUSS_WF 400.400.13.21 ( Built Up )
(2) Section Property
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(1) Slenderness ratio of axial tension member ( L/r )
ㆍ L/r = 48.93 < 200.0 → O.K
(2)
ㆍ Resistance factor for tension : ø = 0.950
ㆍ = = 1,627kip ( Fracture resistance should be checked separately by the user )
ㆍ = 0.136 < 1.000 → O.K
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(1) Web Proportions
ㆍ = 27.54 ≤ 150 → O.K
(2) Flange Proportions
ㆍ = 9.524 ≤ 12.0 → O.K
ㆍ = 15.75 ≥ D/6 = 2.349 → O.K
ㆍ = = 0.563 → O.K
ㆍ = 269in⁴
1/3
ㆍ = 269in⁴
ㆍ = 1.000 ≤ 10.0
(3) Flange Lateral bending Stress
ㆍ Web Load-Shedding Factor, Rb
ㆍ In constructibility
ㆍ = 1.000
ㆍ Limiting Unbraced Length, Lp
ㆍ = = 105in
ㆍ = = 4.350in
ㆍ Moment Gradient Modifier, Cb
ㆍ Calculation of Stress C6.4.10
ㆍ
ㆍ = 1.000
ㆍ = 4.906ksi
ㆍ = 4.349ksi
ㆍ Second-order elastic compression-flange Lateral bending stress ( 6.10.1.6 )
ㆍ = = 53.96ksi
ㆍ Check
ㆍ = 0.000in
ㆍ = = min( 432in, 432in ) = 432in
ㆍ
ㆍ = = 53.96ksi
ㆍ = = 30.89ksi → N.G
ㆍ Flexural Resistance based on Continuously Braced Tension Flange ( 6.10.8 )
ㆍ = = 51.49ksi → O.K
ㆍ Local Buckling Resistance based on Discretely Braced Compression Flange ( 6.10.8.2.2 )
ㆍ = = 9.524
ㆍ = = 9.132
ㆍ Web Load-Shedding Factor, Rb
ㆍ Because of the Composite Section satisfied the Section Proportions in Positive Flexure.
ㆍ = 1.000
ㆍ
ㆍ = = 36.04ksi
ㆍ = = 16.08
ㆍ = = 50.62ksi
ㆍ Limiting Unbraced Length, Lp
ㆍ = = 105in
ㆍ = = 4.350in
ㆍ Lateral-Torsional Buckling Resistance based on Discretely Braced Compression Flange ( 6.10.8.2.2 )
ㆍ
ㆍ = = 51.49ksi
ㆍ = = 50.62ksi
ㆍ = = 50.62ksi → O.K
2/3
Combined Ratio 0.86
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(2) Calculate interaction ratio of combined strength
ㆍ
ㆍ ComRat = = 0.855 < 1.000 → O.K
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(2)
ㆍ for webs of all other doubly/singly symmetric shapes and channels
ㆍ = = 29.48
ㆍ = 1.000
(3) Calculate shear strength in local-y direction
ㆍ = 26.04in²
ㆍ = = 778kip
ㆍ Resistance factor for shear : ø = 1.000
ㆍ = -35.59kip
ㆍ = 778kip
ㆍ = 0.0458 < 1.000 → O.K
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(2) Calculate the web shear coefficient ( C )
ㆍ for all other H-Shape members and channels
ㆍ k ( the web plate buckling coefficient ) = 5.000
ㆍ = = 60.18
ㆍ C = 1.000
(3) Calculate shear strength in local-z direction
ㆍ = 7.214in²
ㆍ = = 215kip
ㆍ Resistance factor for shear : ø = 1.000
ㆍ = -2.385kip
ㆍ = 215kip
ㆍ = 0.0111 < 1.000 → O.K
ㆍ
3/3