Download as rtf, pdf, or txt
Download as rtf, pdf, or txt
You are on page 1of 3

■ Member Design Detail Report AASHTO-LRFD 2017

1. Member Information
ㆍ Member : 206

2. Material
(1) Material Name : SM520
(2) : 51.49ksi
(3) : 29,733ksi

3. Length
(1) : 16.40ft
(2) : 16.40ft
(3) : 0.000ft
(4) : 1.000
(5) : 1.000

4. Section
(1) Shape : TRUSS_WF 400.400.13.21 ( Built Up )
(2) Section Property

33.25in² 21.70in² 8.060in² 7.874in 7.874in

199in³ 68.37in³ 220in³ 103in³ 6.600in⁴

6.872in 4.023in 1,570in³ 538in³ 0.000in⁴

5. Check Axial Strength


Category Value Criteria Ratio Note
Slenderness Ratio 48.93 200 0.245
Tension Strength ( kip ) -222 1,627 0.136
Slenderness Ratio 0.24

Tension Strength 0.14

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(1) Slenderness ratio of axial tension member ( L/r )
ㆍ L/r = 48.93 < 200.0 → O.K
(2)
ㆍ Resistance factor for tension : ø = 0.950
ㆍ = = 1,627kip ( Fracture resistance should be checked separately by the user )
ㆍ = 0.136 < 1.000 → O.K

6. Check Flexural Strength About Major Axis ( Y )


Category Value Criteria Ratio Note
Width-Thickness Ratio ( Flange, λp ) 9.524 9.132 1.043
Width-Thickness Ratio ( Flange, λr ) 9.524 9.524 1.000 Noncompact
Moment Strength, Major Axis ( kip·ft ) 72.27 841 0.0859
Moment Strength, Minor Axis ( kip·ft ) 307 438 0.701
Width-Thickness Ratio ( Flange, λp ) 1.04

Width-Thickness Ratio ( Flange, λr ) 1.00

Moment Strength, Major Axis 0.09

Moment Strength, Minor Axis 0.70

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(1) Web Proportions
ㆍ = 27.54 ≤ 150 → O.K
(2) Flange Proportions
ㆍ = 9.524 ≤ 12.0 → O.K
ㆍ = 15.75 ≥ D/6 = 2.349 → O.K
ㆍ = = 0.563 → O.K
ㆍ = 269in⁴

1/3
ㆍ = 269in⁴
ㆍ = 1.000 ≤ 10.0
(3) Flange Lateral bending Stress
ㆍ Web Load-Shedding Factor, Rb
ㆍ In constructibility
ㆍ = 1.000
ㆍ Limiting Unbraced Length, Lp
ㆍ = = 105in
ㆍ = = 4.350in
ㆍ Moment Gradient Modifier, Cb
ㆍ Calculation of Stress C6.4.10

ㆍ = 1.000
ㆍ = 4.906ksi
ㆍ = 4.349ksi
ㆍ Second-order elastic compression-flange Lateral bending stress ( 6.10.1.6 )
ㆍ = = 53.96ksi
ㆍ Check
ㆍ = 0.000in
ㆍ = = min( 432in, 432in ) = 432in

ㆍ = = 53.96ksi
ㆍ = = 30.89ksi → N.G
ㆍ Flexural Resistance based on Continuously Braced Tension Flange ( 6.10.8 )
ㆍ = = 51.49ksi → O.K
ㆍ Local Buckling Resistance based on Discretely Braced Compression Flange ( 6.10.8.2.2 )
ㆍ = = 9.524
ㆍ = = 9.132
ㆍ Web Load-Shedding Factor, Rb
ㆍ Because of the Composite Section satisfied the Section Proportions in Positive Flexure.
ㆍ = 1.000

ㆍ = = 36.04ksi
ㆍ = = 16.08
ㆍ = = 50.62ksi
ㆍ Limiting Unbraced Length, Lp
ㆍ = = 105in
ㆍ = = 4.350in
ㆍ Lateral-Torsional Buckling Resistance based on Discretely Braced Compression Flange ( 6.10.8.2.2 )

ㆍ = = 51.49ksi
ㆍ = = 50.62ksi
ㆍ = = 50.62ksi → O.K

7. Check Flexural Strength About Minor Axis ( Z )


(1) Calculate limiting width-thickness ratio of flange for flexure
ㆍ = = 9.132
ㆍ = = 19.95
(2) Check width-thickness ratio of flange ( BTR )
ㆍ BTR = = 19.95 → Noncompact
(3) Calculate nominal flexural strength for Yielding ( Y )
ㆍ = = 438kip·ft
(4) Calculate flexural strength about minor axis
ㆍ = = 438kip·ft
ㆍ Resistance factor for flexure : ø = 1.000
ㆍ = 438kip·ft
ㆍ = 0.701 < 1.000 → O.K

8. Check Interaction of Combined Strength


ㆍ Load Combination Name : 1
ㆍ Position : J
Category Value Criteria Ratio Note
Combined Ratio 0.855 1.000 0.855

2/3
Combined Ratio 0.86

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(2) Calculate interaction ratio of combined strength

ㆍ ComRat = = 0.855 < 1.000 → O.K

9. Check Shear Strength ( Y )


ㆍ Load Combination Name : 2
ㆍ Position : I
Category Value Criteria Ratio Note
Shear Strength, Minor Axis ( kip ) -35.59 778 0.0458
Shear Strength, Minor Axis 0.05

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(2)
ㆍ for webs of all other doubly/singly symmetric shapes and channels
ㆍ = = 29.48
ㆍ = 1.000
(3) Calculate shear strength in local-y direction
ㆍ = 26.04in²
ㆍ = = 778kip
ㆍ Resistance factor for shear : ø = 1.000
ㆍ = -35.59kip
ㆍ = 778kip
ㆍ = 0.0458 < 1.000 → O.K

10. Check Shear Strength ( Z )


ㆍ Load Combination Name : 1
ㆍ Position : J
Category Value Criteria Ratio Note
Shear Strength, Minor Axis ( kip ) -2.385 215 0.0111
Shear Strength, Minor Axis 0.01

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(2) Calculate the web shear coefficient ( C )
ㆍ for all other H-Shape members and channels
ㆍ k ( the web plate buckling coefficient ) = 5.000
ㆍ = = 60.18
ㆍ C = 1.000
(3) Calculate shear strength in local-z direction
ㆍ = 7.214in²
ㆍ = = 215kip
ㆍ Resistance factor for shear : ø = 1.000
ㆍ = -2.385kip
ㆍ = 215kip
ㆍ = 0.0111 < 1.000 → O.K

3/3

You might also like