Service news

For internal use only

ELEKTRONIKON Priority: IV ECB AII 0182/C1


Mk3 to Mk4 retrofit kits - Overview GAC: 453, Date: 28.04.04
457, 454, Page 1/2
458, 455,
456

1. Subject
During the TSC 2003/2004 we have presented an overview of the different available retrofit kits.
Today a few things are updated resulting in next actual status.
Industrial Air division (AII) has released three kits for A, B and C controller.
Oil free Air division (AIF) has released one kit for D controller. This means for ZT37VSD you’ll have
to use the AIF kit.

Below you can find a new overview.


The different installation guides in English will be published on the AII service website >> Technical
information >> ASC binders Industrial Air Division >> Common Documents . If necessary you can
translate them in your local language.

The price is specially kept low to promote conversion of Mk3 units to Mk4 for integration in
compressor (CAN) networks. In generally a retrofit is more economical feasible then installing a
COMbox.

2. Actual kits

AII AIF
GA55-90C SF6-15
GA5-55C GAVSD ZR45-55 Z VSD
(except GA90VSD
<AII492000) ZT18-55
From Mk3: LRR HRRS HRRE HRRE
To Mk4: Mk4 II/A Mk4 II/B Mk4 III/C Mk4 III/D
Retrofit kit: 2902 0096 01 2902 0096 11* 2902 0096 21*** 2906 0595 01**
Installation
9820 4217 00 9820 4218 00 9820 4219 00 2946 0456 00
Guide:
FDP database: 1900 0712 26 1900 0712 26 1900 0712 26 1900 0712 26

* Note:

• Unfortunately, for GA90 VSD with serial nr < AII 492000 (SIMOVERT P) today there is no
retrofit possible because of the RS232 interface between Mk3 and the converter. (Mk4
uses RS485)
Our marketing and engineering are aware of this situation and are looking for a solution.

CSS CSS-wc DN 04 0007 03


ECB AII 0182/C1
Page 2/2

• For water cooled versions or if energy recovery installed, order extra expansion module
AIE1 1900 0710 41 together with one of next cables:

1622 0661 01 Communication cable 600 mm


Or 1622 0661 02 Communication cable 150 mm
Or 1622 0661 03 Communication cable 400 mm
Or 1621 0832 00 Communication cable 1550 mm
Or 1621 6770 00 Communication cable 2500 mm
Do not use the MK3 communication cables !!! The execution of the cables is not identical.
The cables shall be disposed of.

• For VSD versions replace original temperature sensors by screened versions

1089 0574 35 Temperature sensor for converter cubicle (Siemens)


1089 0574 40 All other temperature sensors

**Note:

• For VSD versions replace original temperature sensors by screened versions

1089 0574 35 Temperature sensor for converter cubicle (Siemens)


1089 0574 40 All other temperature sensors.

***Note:

• For SF6-15, replace original temperature switch by temperature sensor (one per element)

1089 0574 60 Temperature sensor


2236 0113 00 Mounting plate
0226 0300 41 Screw

4. Reason of the modification


The kit 2902 0096 31 is replaced by 2906 0595 01.

5. Introduction date
Already effective.