MANNING'S EQUATION FOR PIPE FLOW

Project: Townhouses at Arad Location: Block 241,242


By: HGS Date: 11/12/2014
Chk. By: Date:

INPUT
D
h D= 250 mm
h= 235 mm
Mannings Formula n= 0.015 mannings coeff
q= 56.7 degrees
q
Q=(1/n)ARh2/3S1/2 S= 0.005 slope m/m
R=A/P 94% % full
A=cross sectional area

P=wetted perimeter V=(1/n)Rh2/3S1/2


S=slope of channel Q=V x A
n=Manning's roughness coefficient
Solution to Mannings Equation Manning's n-values

Wetted Hydraulic
Area,m² Perimeter, m Radius, m velocity m/s flow, lps PVC 0.01
0.0479 0.6617 0.0724 0.82 39.201 PE (<9"dia) 0.015
PE (>12"dia) 0.02
PE(9-12"dia) 0.017
Velocity Head: 0.0342 m CMP 0.025
Froude No.: 0.412 - ADS N12 0.012
Top Width: 119 mm HCMP 0.023
Conc 0.013

Design Parameters Flow Q:


# of Services 310 Resulting Peak Flow: 11.11 lps
Average Flow 240 lpcd Average Daily Flow: 558 m³/d
Avg. Occupancy 6
Peaking Factor 1.9
Infiltration/Inflow 60 lpcd

You might also like