Professional Documents
Culture Documents
TR5801 Af60-Hd En55035 01
TR5801 Af60-Hd En55035 01
Draper, UT 84020
Test Report
Declaration of Conformity
On this 9th day of February 2021, I individually and for Unified Compliance Laboratory certify
that the statements made in this engineering report are true, complete and correct to the best of my
knowledge and are made in good faith.
Although NVLAP has accredited the Unified Compliance Laboratory testing facilities, this report
must not be used to claim product certification, approval, or endorsement by NVLAP, NIST or any
agency of the U.S. federal government.
TR5801_AF60-HD_EN55035_01 Page 2 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
Revision History
Revision Description Date
01 Original Report Release 9 February 2021
TR5801_AF60-HD_EN55035_01 Page 3 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
Table of Contents
1.1 Applicant ....................................................................................................................................... 5
1.2 Manufacturer ................................................................................................................................. 5
1.3 Declaration of Conformity Responsible Party .............................................................................. 5
2 Equipment Under Test (EUT) ............................................................................................................... 6
2.1 Identification of EUT .................................................................................................................... 6
2.2 Description of EUT ....................................................................................................................... 6
2.3 EUT and Support Equipment ........................................................................................................ 6
2.4 Interface Ports on EUT ................................................................................................................. 7
2.5 Operating Environment ................................................................................................................. 7
2.6 Operating Modes ........................................................................................................................... 7
2.7 EUT Exercise Software................................................................................................................. 7
2.8 Performance Criteria ..................................................................................................................... 7
2.9 Monitoring of the EUT ................................................................................................................. 8
2.10 Block Diagram of Test Configuration .......................................................................................... 9
2.11 Modification Incorporated/Special Accessories on EUT .............................................................. 9
2.12 Deviation, Opinions, Additional Information or Interpretations from Test Standard ................... 9
3 Test Specification, Method and Procedures ........................................................................................ 10
3.1 Test Specification........................................................................................................................ 10
3.2 Methods & Procedures ................................................................................................................ 10
3.3 EN 55035 Refers to the Following Basic Standards ................................................................... 11
3.4 Summary of Test Results ............................................................................................................ 11
3.5 Test Results ................................................................................................................................. 12
3.6 Test Location .............................................................................................................................. 12
4 Test Equipment ................................................................................................................................... 13
4.1 Test Equipment ........................................................................................................................... 13
4.2 Equipment Calibration ................................................................................................................ 19
4.3 Measurement Uncertainty ........................................................................................................... 19
5 Photographs......................................................................................................................................... 20
6 Test Results ......................................................................................................................................... 27
6.1 Electrostatic Discharge ............................................................................................................... 27
6.2 Radio-Frequency Electromagnetic Field..................................................................................... 29
6.3 Electrical Fast Transients ............................................................................................................ 31
6.4 Surges.......................................................................................................................................... 32
6.5 Radio-Frequency Continuous Conducted ................................................................................... 34
6.6 Power-Frequency Magnetic Field ............................................................................................... 35
6.7 Voltage Dips and Interruptions ................................................................................................... 36
6.8 Harmonic Current Emissions ...................................................................................................... 37
6.9 Voltage Fluctuations and Flicker ................................................................................................ 38
TR5801_AF60-HD_EN55035_01 Page 4 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
Client Information
1.1 Applicant
Ubiquiti Inc.
685 Third Avenue
Company
New York, NY 10017
U.S.A.
Contact Name Mark Feil
1.2 Manufacturer
Ubiquiti Inc.
685 Third Avenue
Company
New York, NY 10017
U.S.A.
Contact Name Mark Feil
TR5801_AF60-HD_EN55035_01 Page 5 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
TR5801_AF60-HD_EN55035_01 Page 6 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
TR5801_AF60-HD_EN55035_01 Page 7 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
performance level specified by the manufacturer, when the EUT is used as intended. The performance
level may be replaced by a permissible loss of performance.
During the test, degradation of performance is allowed. However, no change of operating state or stored
data is allowed to persist after the test.
If the minimum performance level (or the permissible performance loss) is not specified by the
manufacturer, then either of these may be derived from the product description and documentation, and
by what the user may reasonably expect from the EUT if used as intended.
2.8.3 Criteria C
During and after testing, a temporary loss of function is allowed, provided the function is self-
recoverable, or can be restored by the operation of the controls or cycling of the power to the EUT by the
user in accordance with the manufacturer’s instructions.
Functions, and/or information stored in non-volatile memory, or protected by a battery backup, shall not
be lost.
2.9 Monitoring of the EUT
The AF60-HD was monitored via two command prompt applications on the Laptop PC
monitoring the AF60-HD IP address of the DUT and wirelessly pinning the second paired AF60-
HD to insure connectivity and correct operation.
TR5801_AF60-HD_EN55035_01 Page 8 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
TR5801_AF60-HD_EN55035_01 Page 9 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
3.2.6 EN 61000-3-3:2013
See test standard for details.
3.3 EN 55035 Refers to the Following Basic Standards
Basic Standard Date Title
Electromagnetic compatibility (EMC) – Part 4-2. Testing and
EN 61000-4-2 2009
measurement techniques – Electrostatic Discharge immunity test.
2006 Electromagnetic compatibility (EMC) – Part 4-3. Testing and
EN 61000-4-3
2008 measurement techniques – Radiated, radio frequency, electromagnetic
+A1+A2
2010 field immunity test.
Electromagnetic compatibility (EMC) – Part 4-4. Testing and
EN 61000-4-4 2012
measurement techniques – Electrical fast transient/burst immunity test.
Electromagnetic compatibility (EMC) – Part 4-5. Testing and
EN061000-4-5 2014
measurement techniques – Surge immunity test.
Electromagnetic compatibility (EMC) – Part 4-6. Testing and
EN 61000-4-6 2014 measurement techniques – Immunity to conducted disturbances,
induced by radio frequency field immunity test.
Electromagnetic compatibility (EMC) – Part 4-8. Testing and
EN 61000-4-8 2010 measurement techniques – Power frequency magnetic field immunity
test.
Electromagnetic compatibility (EMC) – Part 4-11. Testing and
EN 61000-4-11 2004 measurement techniques – Voltage dips, short interruptions and voltage
variations immunity test.
3.4 Summary of Test Results
3.4.1 Summary of Test EN 55035
Enclosure Port
Basic Standard Environmental Phenomena Results
EN 61000-4-8 Power-frequency magnetic field Complied
EN 61000-4-3 Radio Frequency Electromagnetic Field Complied
EN 61000-4-2 Electrostatic Discharge Complied
DC Power Ports
Basic Standard Environmental Phenomena Results
EN 61000-4-6 Radio-Frequency continuous conducted Note 1
TR5801_AF60-HD_EN55035_01 Page 11 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
AC Power Ports
Basic Standard Environmental Phenomena Results
EN 61000-4-6 Radio-Frequency continuous conducted Complied
EN 61000-4-5 Surge Complied
EN 61000-4-4 Electrical fast transient/burst Complied
EN 61000-4-11 Voltage Dips and Interruptions Complied
3.4.2 Summary of Test EN 61000-3-2 and EN 61000-3-3
AC Power Port
Basic Standard Environmental Phenomena Results
EN 61000-3-2 Harmonic Current Measurement Complied
EN 61000-3-3 Voltage Flicker Measurement Complied
3.5 Test Results
In the configuration tested, the EUT complied with the requirements of the specification.
3.6 Test Location
Testing was performed at the Unified Compliance Laboratory 3-Meter and 10-Meter chambers located at
427 West 12800 South, Draper, UT 84020. Unified Compliance Laboratory is accredited by National
Voluntary Laboratory Accreditation Program (NVLAP); NVLAP Code 600241-0 which is effective until
30 June 2021.
TR5801_AF60-HD_EN55035_01 Page 12 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
4 Test Equipment
4.1 Test Equipment
4.1.1 Electrostatic Discharge
TR5801_AF60-HD_EN55035_01 Page 13 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
TR5801_AF60-HD_EN55035_01 Page 14 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
TR5801_AF60-HD_EN55035_01 Page 15 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
4.1.4 Surges
TR5801_AF60-HD_EN55035_01 Page 16 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
TR5801_AF60-HD_EN55035_01 Page 17 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
TR5801_AF60-HD_EN55035_01 Page 18 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
TR5801_AF60-HD_EN55035_01 Page 19 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
5 Photographs
TR5801_AF60-HD_EN55035_01 Page 20 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
TR5801_AF60-HD_EN55035_01 Page 21 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
TR5801_AF60-HD_EN55035_01 Page 22 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
TR5801_AF60-HD_EN55035_01 Page 23 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
TR5801_AF60-HD_EN55035_01 Page 24 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
TR5801_AF60-HD_EN55035_01 Page 25 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
TR5801_AF60-HD_EN55035_01 Page 26 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
6 Test Results
6.1 Electrostatic Discharge
Port Enclosure
Performance Criterion B
4 kV (Contact discharge)
Limit
2,4,8, kV (Air discharge)
Temperature during testing 24.1 ºC (15º to 35ºC)
TR5801_AF60-HD_EN55035_01 Page 27 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
Discharge
Discharge
Discharge Point Voltage Comment Result
Type
(kV)
Horizontal Coupling Plane 4 Contact Note 1 Complied
TR5801_AF60-HD_EN55035_01 Page 28 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
Port Enclosure
Performance Criterion A
Limit 10 V/m
Dwell Time 1s
TR5801_AF60-HD_EN55035_01 Page 29 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
Frequency Level
Exposed Area Polarity Comment Result
(MHZ) (V/m)
80 - 1000 10 Front Horizontal Note 1 Complied
TR5801_AF60-HD_EN55035_01 Page 30 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
Performance Criterion B
0.5 kV – 5 kHz (signal and telecommunication)
1.0 kV – 100 kHz (signal and telecommunication)
Limit
1.0 kV – 5 kHz (AC power)
2.0 kV – 100 kHz (AC power)
Temperature during testing 22.1 ºC
Severity
Line Level Polarity Duration Comment Result
(kV)
L1, L2, PE 1.0 Pos & Neg 2 Min Note 1 Complied
TR5801_AF60-HD_EN55035_01 Page 31 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
6.4 Surges
Port AC power
Performance Criterion B
Line-Neutral: 0.5 kV, 1kV
Limit Line-PE: 0.5 KV, 1 kV, 2 kV
Neutral-PE: 0.5 kV, 1 kV, 2 kV
Temperature during testing 22.1 ºC
Severity
Level Phase Angle of
Surge Applied Number of Surges Comment
AC Voltage Wave
(kV)
Line to Neutral 0.5 0º-270º (90º incr.) 5 Positive, 5 Negative Note 1
TR5801_AF60-HD_EN55035_01 Page 32 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
Performance Criterion B
Port type: coaxial or shielded Apply: shield to
Limit
ground: 1.2/50us Waveform at 0.5kV
Temperature during testing 22.1 ºC
Severity
Level Phase Angle of
Surge Applied Number of Surges Comment
AC Voltage Wave
(kV)
Shield to Earth 0.5 N/A 5 Positive, 5 Negative Note 1
TR5801_AF60-HD_EN55035_01 Page 33 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
Performance Criterion A
Limit 3V
Level
Frequency (MHZ) Exposed Port Comment Result
(V)
0.15 - 80 3.0 Mains Input Note 1 Complied
Note 1
0.15 - 80 3.0 Ethernet Input Complied
Note 2
Note 1
0.15 - 80 3.0 PoE Input Complied
Note 2
Note 1: There was no observable degradation in the performance of the EUT
Note 2: Both shielded and unshielded cables were evaluated
Result
In the configuration tested, the EUT complied with the specification.
TR5801_AF60-HD_EN55035_01 Page 34 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
Port Enclosure
Performance Criterion A
Limit 30 A/m
Level
Frequency (HZ) Exposed Port Comment Result
(V)
50 & 60 1 Enclosure Note 1 Complied
TR5801_AF60-HD_EN55035_01 Page 35 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
Port AC power
TR5801_AF60-HD_EN55035_01 Page 36 of 39
PROPRIETARY
427 West 12800 South, Draper, UT 84020
Port AC power
Port AC power
TR5801_AF60-HD_EN55035_01 Page 39 of 39
PROPRIETARY