Professional Documents
Culture Documents
LACTICRATE@Guard EA TDS
LACTICRATE@Guard EA TDS
Guard EA
Guard EA uses novel hybrid technology to create a two-component polymeric coatings that offers
excellent UV resistance properties, rapid dry and reduced cure time.
Globally Proven
Construction Solutions
FEATURES/BENEFITS USES
Low viscosity, easy-to-apply Interior and exterior (floor and wall, new and retrofit
Low odour application project)
Longer pot life Public buildings (school, office building, hospital,
Faster return to service stadium)
Good chemical resistance Light to Medium industrial floors
Non-staining finish Storage
Hot/cold tire pick-up resistance Traffic decks
Durability Service roof
Positive slip resistance applicable Garages
Good abrasion resistance Pedestal and cycling path
Excellent UV resistance
Inhibiting growth of micro-organism
Good mechanical performance
LATICRETE South East Asia Pte Ltd | 38 Sungei Kadut Street 2, Level 2 A3, Singapore 729245 | 65-6515 3028 | 65-6515 3037 | enquiry@laticrete.com.sg
Copyright 2019 Data Sheets are subject to change without notice. For latest revision, visit se.laticrete.com
DS14-GEA-0319
LATICRETE South East Asia Pte Ltd | 38 Sungei Kadut Street 2, Level 2 A3, Singapore 729245 | 65-6515 3028 | 65-6515 3037 | enquiry@laticrete.com.sg
Copyright 2019 Data Sheets are subject to change without notice. For latest revision, visit se.laticrete.com
DS14-GEA-0319
injury, loss or damage directly or indirectly resulting from use or application. Sufficient ventilation is essential
inability to use the product.
during the application for enclosed facilities in
particular.
INSTALLATION
AVAILABILITY AND COST
Suitable substrates/Surface
Suitable substrates such as concrete (G30), polymer Availability
LATICRETE® materials are available worldwide.
modified screed, resinous surfaces etc. The
For distributor information, call:
substrate should have a minimum cohesive strength
Telephone: (65) 6515-3028
of 1.5 N/mm², free from laitance, loose adherent,
Fax: (65) 6515-3037
oils, grease and previous sealer, curing compound
For on-line distributor information, visit
which might have adverse effect to the bonding of
LATICRETE at se.laticrete.com
the subsequent coating finish.
Cost
Surface Preparation
Contact a LATICRETE Distributor in your area.
Prepare surface by mechanical grinding or
scrubbing with diamond grit 80 – 100 is
recommended to achieve CSP 2 in according to WARRANTY
Subject to the conditions and limitations stated
ICRI Technical Guide 310.2, SSPC – 13 or where
below, LATICRETE South East Asia Pte Ltd
appropriate. The prepared surface should be free
warrants that its products will be free from
from oils, grease or adhesion barriers, cracking,
manufacturing defects and will not break down or
pores or bug holes etc.
deteriorate under normal usage for a period of one
(1) year from the date of purchase when installed in
Mixing
accordance with the written specifications of
Mechanical mixing is required for Guard EA. A low
LATICRETE and industry standard guidelines.
speed drill mixer is recommended. Stir component
A & B individually first for about 30 seconds. Mix
MAINTENANCE
part B slowly and add in part A. Continue to mix for
The long term performance, appearance, and life
2 - 3 minutes. Mix until homogenous in colour.
expectancy of wear surface products are critically
Cover unused mixture tightly and use within 2
dependence upon a good routine maintenance
hours.Always stir before use. DO NOT add in other
program designed specifically for the installed wear
liquids in to the mixture.
surface. Anti-slip textured epoxy floor coating
systems might trapped dirt and contaminants onto
Application
the surface. The use of properly placed walk-off
Recommended tools for applications - rubber
mats, inside and outside, will help increase the life
squeegee, short pile roller or sponge roller and
of the floor. Recommend maintenance program
brushes. Surface temperature should be at 5°C to
consist on frequent and through cleaning utilizing a
35°C and atmospheric relative humidity
neutral pH cleaner (e.g. Simple Green®). Frequency
should be below 90% during the application.
of washing will vary depending on floor usage type,
Thinning is strictly not recommended as it will
traffic and age.
compromise the optimum performance of the
material.
TECHNICAL SERVICES/ CONTACT
Technical Assistance
Curing
Information is available by calling:
Guard EA is self-curing. The curing time is
depending on the ambient temperature, humidity
LATICRETE South East Asia Pte Ltd
and the quantity mixed and placed. Under normal
(Level 2, A3)
circumstances initial curing will take place an hour
No. 38 Sungei Kadut, Street 2,
after application. The coating require 7 days for full
Singapore 729245
chemical curing.
Telephone: (65) 6515-3028
Fax: (65) 6515-3037
Safety, Health and Enviroment Impact
Email: enquiry@laticrete.com.sg
Working crew is strongly recommended to wear
appropriate personal protective equipment such as
chemical glove, breathing device, safety goggle, to Technical and safety literature
To acquire technical and safety literature, please
avoid contact with the chemical during the
visit our website at se.laticrete.com
LATICRETE South East Asia Pte Ltd | 38 Sungei Kadut Street 2, Level 2 A3, Singapore 729245 | 65-6515 3028 | 65-6515 3037 | enquiry@laticrete.com.sg