DC Output Modules: D2-32TD1 DC Output $138.00 D2-32TD2 DC Output $138.00
DC Output Modules: D2-32TD1 DC Output $138.00 D2-32TD2 DC Output $138.00
DC Output Modules
D2-32TD1 DC Output $138.00 D2-32TD2 DC Output $138.00
Outputs per Module 32 (current sinking) Outputs per Module 32 (current sourcing)
Commons per Module 4 (8 I/O terminal points) Commons per Module 4 (8 I/O terminal points)
Output Type NPN open collector Output Type Transistor
Operating Voltage 12-24 VDC Operating Voltage 12 to 24 VDC
Peak Voltage 30VDC Peak Voltage 30VDC
ON Voltage Drop 0.5 VDC maximum ON Voltage Drop 0.5 VDC @ 0.1 A
Minimum Load Current 0.2 mA Minimum Load Current 0.2 mA
Max Load Current 0.1 A/point; 3.2 A per module Max Load Current 0.1 A/point; 0.8 A/common
Max Leakage Current 0.1 mA @ 30VDC Max Leakage Current 0.1 mA @ 30VDC
Max Inrush Current 150mA for 10ms Max Inrush Current 150mA @ 10ms
Base Power Required 5VDC 350mA Base Power Required 5VDC 350mA
OFF to ON Response 0.5 ms OFF to ON Response 0.5 ms
ON to OFF Response 0.5 ms ON to OFF Response 0.5 ms
Terminal Type (not included) 40-pin connector 1
Terminal Type (not included) 40-pin connector1
Status Indicator Module activity (no I/O status indicators) Status Indicator Module activity (no I/O status indicators)
Weight 2.1 oz. (60g) Weight 2.1 oz (60g)
Fuses None Fuses None
External DC Power Required 20-28 VDC max. 120mA (all points on) 1
Connector sold separately.
1
Connector sold separately. See Terminal Blocks and Wiring for wiring options.
See Terminal Blocks and Wiring for wiring options. See Wiring Solutions for part numbers of ZIPLink
See Wiring Solutions for part numbers of ZIPLink cables and connection modules compatible with
cables and connection modules compatible with this this I/O module.
I/O module.
OUT 12-24
VDC
ACT
OUT 12-24
VDC D2-32TD2
ACT A0 A4
A1 A5
A2 A6
D2-32TD1 A3 A7
A0 A4 CI VI
A1 A5 B0 B4
A2 A6 B1 B5
A3 A7 B2 B6
CI VI B3 B7
B0 B4 CII VII
B1 B5 C0 C4
B2 B6 C1 C5
B3 B7 C2 C6
CII VII C3 C7
C0 C4 CIII VIII
C1 C5 D0 D4
C2 C6 D1 D5
C3 C7 D2 D6
D3 D7
CIII VIII
CIV VIV
D0 D4
D1 D5 12-24VDC
D2 D6 0.1A
CLASS2
D3 D7
CIV VIV
12-24VDC
0.1A
CLASS2
Wiring Solutions
Wiring Solutions using the ZIPLink Wiring System
ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector
modules. It’s as simple as plugging in a cable connector at either end or terminating wires at only one end. Prewired cables keep
installation clean and efficient, using half the space at a fraction of the cost of standard terminal blocks. There are several wiring
solutions available when using the ZIPLink System ranging from PLC I/O-to-ZIPLink Connector Modules that are ready for field
termination, options for connecting to third party devices, GS, DuraPulse and SureServo Drives, as well as special relay, transorb
and communications modules. Pre-printed I/O-specific adhesive label strips for quick marking of ZIPLink modules are provided
with ZIPLink cables. See the following solutions to help determine the best ZIPLink system for your application.
Solution 3: GS Series and DuraPulse Drives Using the Drives Communication selector tables
Communication Cables located in this section,
Need to communicate via Modbus RTU to a drive or a 1. Locate your Drive and type of communications
network of drives? 2. Select a ZIPLink cable and other associated hardware.
ZIPLink cables are available in a wide range of
configurations for connecting to PLCs and SureServo,
SureStep, Stellar Soft Starter and AC drives. Add a ZIPLink
communications module to quickly and easily set up a multi-
device network.
Wiring Solutions
Solution 4: Serial Communications Cables
ZIPLink offers communications cables for use with DirectLOGIC, CLICK, Using the Serial Communications Cables
and Productivity CPUs, that can also be used with other communications selector table located in this section,
devices. Connections include a 6-pin RJ12 or 9-pin, 15-pin and 25-pin 1. Locate your connector type
D-sub connectors which can be used in conjunction with the RJ12 or 2. Select a cable.
D-Sub feedthrough modules.
D2-08TA ZL-D2-CBL10
Do-more/DL205 PLC Analog Module ZIPLink Selector 10 Feedthrough ZL-D2-CBL10-1
F2-08TA ZL-RTB20 (-1) ZL-D2-CBL10-2
PLC ZIPLink
Analog # of Feedthrough ZL-D2-CBL19
Component Module Cable D2-12TA 19 ZL-D2-CBL19-1
Module Terms Fuse ZL-RFU20 4
ZL-D2-CBL19-2
F2-04AD-1
D2-04TRS 2 ZL-D2-CBL10
F2-04AD-1L 10 Feedthrough ZL-D2-CBL10-1
F2-08AD-1 D2-08TR ZL-D2-CBL10-2
F2-04AD-2 ZL-D2-CBL10 F2-08TRS 2 19 ZL-RTB20 (-1) ZL-D2-CBL19 *
ZL-D2-CBL10-1 Feedthrough
F2-04AD-2L ZL-D2-CBL10-2 F2-08TR 3 10 ZL-D2-CBL10 *
F2-08AD-2 Feedthrough ZL-D2-CBL19
F2-02DA-1 D2-12TR 19 ZL-D2-CBL19-1
10 Fuse ZL-RFU20 4 ZL-D2-CBL19-2
F2-02DAS-1
Feedthrough ZL-RTB20 (-1) † X in the part number represents a 45° angle plug
F2-08DA-1 ZL-D2-CBL19
ZL-D2-CBL19-1 * Select the cable length by replacing the * with: Blank = 0.5 m, -1 = 1.0 m,
F2-02DA-2 ZL-D2-CBL19-2 or -2 = 2.0 m.
F2-02DAS-2 1To make a custom cable for the 32-point modules, use: Ribbon-style Connector
ZL-D2-CBL10
F2-08DA-2 ZL-D2-CBL10-1 ZL-D24-CON-R, Solder-style 180° connector ZL-D24-CON or Solder-style 45°
ZL-D2-CBL10-2 connector ZL-D24-CON-X
F2-4AD2DA
F2-8AD4DA-1 ZL-D2-CBL19 2 Caution: The D2-04TD1, D2-04TRS, and F2-08TRS outputs are derated not
19 ZL-D2-CBL19-1 to exceed module specs 2A per point and 2A per common when used with the
F2-8AD4DA-2 ZL-D2-CBL19-2 ZIPLink wiring system.
F2-04RTD Matched These modules are not supported by the ZIPLink 3The F2-08TR outputs are derated not to exceed 2A per point and 4A per common
Only wiring system when used with the ZIPLink wiring system.
F2-04THM
4 Fuses (5 x 20 mm) are not included. See Edison Electronic Fuse section for
(5 x 20 mm) fuse. S500 and GMA electronic circuit protection for fast-acting
maximum protection. S506 and GMC electronic circuit protection for time-
delay performance. Ideal for inductive circuits.
To ensure proper operation, do not exceed the voltage and current rating of
ZIPLink module. ZL-RFU20 = 2A per circuit; ZL-RFU40 = 400mA per circuit.
HERE
Environmental 2"
50mm
specifications min
Use the diagrams below to make sure the Ambient Operating Temperature 32oF to 131oF (0oC to 55oC)
DL205 system can be installed in your Ambient Humidity 30% to 95% relative humidity (non-condensing)
application. To ensure proper airflow for Vibration Resistance MIL STD 810C, Method 514.2
cooling purposes, DL205 bases must Shock Resistance MIL STD 810C, Method 516.2
be mounted horizontally. It is important
to check these dimensions against the Noise Immunity NEMA (ICS3-304)
A
C
OK
5.85”
With D2-DSCB-1 on port 2 148mm
3.54” 2.99”
With 32pt. ZipLink cable or 4.45” 90mm 76mm
base expansion unit cable 113mm
3.62”
With 16pt. I/O 92mm
2.95” B
With 8pt. I/O Airflow
75mm
With D2-EM base expansion module