Kurian, Abhilash

From: Li-Wei Lo <leroy.lo@albemarle.com>


Sent: 05 October 2022 23:35
To: Kurian, Abhilash; Mohammad Mustafa
Cc: John Koch; Abdullah R.Zoubi; Firas Al Shayeb; Khaled Abdelqader; Christopher Romito; Barry
McKenzie; Jason Picou; Ali Golshan; Martin Berdon; Narkar, Sonal; yassir qudah; John Koch;
Khaled Abdelqader; Nick Kimble; Hayden O'Neal; Scott Johnson
Subject: RE: PO#221279 , REQ-00109151 , PRJ#21099 NEBO P-3045 & 3046 Br Bottoms Pumps
Attachments: 4. Pump GA Drawing-signed.pdf; 1. P-3045 3046 Br Bottoms Pumps DS.xlsx

[CAUTION: This email originated from outside of the IDEX systems.


Do not open attachments or click on links unless you recognize, and can verify the sender and know the
content is safe.]
 

Dear Abhilash, 
 
Hope you are doing well! 
1. Please see attached with approved with a minor comment. 
2. Attached datasheet rev#2 is also approved. 
3. Can you please share latest and greatest fabrication schedule? 
4. Can you please provide ITP document for our review and approval? 
 
Let me know if you need anything from me at this moment. 
 
Leroy Lo PE,PMP
| Mechanical Engineer
Work number: +1 281‐282‐1736 
Mobile 857.205.6894 |Leroy.lo@albemarle.com 
 
 
 
 
From: Li‐Wei Lo  
Sent: Tuesday, September 27, 2022 12:21 PM 
To: Kurian, Abhilash <AKurian@idexcorp.com>; Mohammad Mustafa 
<Mohammad.Mustafa@JORDANBROMINE.COM> 
Cc: John Koch <john.koch@albemarle.com>; Abdullah R.Zoubi <abdullah.r.zoubi@JORDANBROMINE.COM>; Firas Al 
Shayeb <firas.shayeb@jordanbromine.com>; Khaled Abdelqader <khaled.abdelqader@JORDANBROMINE.COM>; 
Christopher Romito <christopher.romito@albemarle.com>; Barry McKenzie <barry.mckenzie@albemarle.com>; 
Jason Picou <Jason.Picou@albemarle.com>; Ali Golshan <ali.golshan@albemarle.com>; Martin Berdon 
<Martin.Berdon@Albemarle.com>; Narkar, Sonal <SNarkar@idexcorp.com>; yassir qudah 
<yassir.qudah@JORDANBROMINE.COM>; John Koch <john.koch@albemarle.com>; Khaled Abdelqader 
<khaled.abdelqader@JORDANBROMINE.COM>; Nick Kimble <NKimble@hargrove‐epc.com>; Hayden O'Neal 
<honeal@hargrove‐epc.com>; Scott Johnson <sjohnson@hargrove‐epc.com> 
Subject: RE: PO#221279 , REQ‐00109151 , PRJ#21099 NEBO P‐3045 & 3046 Br Bottoms Pumps 
 
Dear Abhilash, 
 
Please see our response in green. Please kindly let me know if you need anything from me. Thank you. 
 
1‐ We recommend RF pump flanges instead of FF.  Response from Pulsafeeder: Not Incorporated. 
1
Plastic flanges generally don’t have a raised face like metal flanges. Our standard Plastic flange we buy has 
two to three raised ribs on the surface for sealing on the gasket. Below is a image from their catalog. The 
past Kynar/PVDF flange we purchased did have a more uniform face. Hence, the Flange Face shall be FF. 
RF facing mentioned in R0 was a typo error. ALB/JBC response: agree on FF, however kindly we need the 
vendor to provide the torque values for all flanges and advise if Nord lock washers (X‐series ‐ belleville 
washers) can be used on these flanges?   

 
2‐ To confirm Backup ring for the Pulsation dampener flanges if this applicable again. Response from 
Pulsafeeder:  This point is not incorporated. Please refer  "Attachment ‐ 1 ‐ Email communication" Point No. 
3, wherein we had mentioned the following. "We can’t provide CS/ PVDF Lined flanges. We are offering 
PVDF flanges. SS backing flanges / rings are not applicable for the offered dampeners." ALB/JBC response, 
no more comments 
3‐ To update the vendor’s DS to match with our DS, there are missing data like SG and vapor pressure. 
Understood and will update 
4‐ Let us please check with Pulsafeeder if it possible to provide ceramic ball for the check valves instead of 
PVDF in this stage (although PVDF is approved MOC), but the last time they supply spare base shaft pump to 
JBC for the existing plant they upgraded the MOC for the ball to be ALA Alumina Ceramic, let’s check with 
them please. Response from Pulsafeeder:  This point is not incorporated. Note that we have currently 
offered Disc type check valve and not ball type check valves. Refer Pump Cross‐sectional Drawing & Sec. 
5.09 of the pump datasheet for more details. For higher flows, it is much better to have disc type check 
valves instead of ball type check valves. Please re‐check and confirm whether you require ball type check. 
ALB/JBC response, agree this is the first time we try disc type on these pumps, but it worth to try it, however 
we need confirmation from the vendor about the dimension (face to face distance ) of the disc type if it is 
the same as ball check valve dimension, this is just in case we need to install the ball type in the future..? 
5‐ They should provide the calculation for the pulsation dampener, is pulsation dampener capacity and size 
correct? The size is 1” while pump is 2”. 
Response from Pulsafeeder:  Attachment ‐ 2 ‐ PD Calculation, ALB/JBC response, no comments 
 
Leroy Lo PE,PMP
| Mechanical Engineer
Work number: +1 281‐282‐1736 
Mobile 857.205.6894 |Leroy.lo@albemarle.com 
 
 
 
From: Kurian, Abhilash <AKurian@idexcorp.com>  
Sent: Tuesday, September 27, 2022 12:15 PM 
To: Li‐Wei Lo <leroy.lo@albemarle.com>; Mohammad Mustafa <Mohammad.Mustafa@JORDANBROMINE.COM> 
Cc: John Koch <john.koch@albemarle.com>; Abdullah R.Zoubi <abdullah.r.zoubi@JORDANBROMINE.COM>; Firas Al 
Shayeb <firas.shayeb@jordanbromine.com>; Khaled Abdelqader <khaled.abdelqader@JORDANBROMINE.COM>; 
Christopher Romito <christopher.romito@albemarle.com>; Barry McKenzie <barry.mckenzie@albemarle.com>; 
Jason Picou <Jason.Picou@albemarle.com>; Ali Golshan <ali.golshan@albemarle.com>; Martin Berdon 
<Martin.Berdon@Albemarle.com>; Narkar, Sonal <SNarkar@idexcorp.com>; yassir qudah 
<yassir.qudah@JORDANBROMINE.COM>; John Koch <john.koch@albemarle.com>; Khaled Abdelqader 
<khaled.abdelqader@JORDANBROMINE.COM>; Nick Kimble <NKimble@hargrove‐epc.com>; Hayden O'Neal 
<honeal@hargrove‐epc.com>; Scott Johnson <sjohnson@hargrove‐epc.com> 
Subject: RE: PO#221279 , REQ‐00109151 , PRJ#21099 NEBO P‐3045 & 3046 Br Bottoms Pumps 
2

You might also like