Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

BTL-6000 SHORTWAVE 400 BTL-6000 SHORTWAVE 200

User-interface Colour 5.7“ touch-screen Colour 5.7“ touch-screen

Inductive / Capacitive 1 or 2 channels inductive 1 or 2 channels inductive


1 channel capacitive

Power 400W Pulse 200W Pulse


200W Continuous 100W Continuous

Preset Protocols BTL encyclopaedia BTL encyclopaedia


62 indications 62 indications

User Programmes 100 user-defined programmes 100 user-defined programmes

Pulse Frequency 50 – 1500Hz 50 – 1500Hz

PROVEN THERAPY Pulse Length 50 – 2000µs 50 – 2000µs

LATEST TECHNOLOGY
Optional Accessories

Inductive Applicators 80mm 80mm


140mm 140mm

Capacitive Applicators 42mm


85mm
130mm

Soft-rubber Plate Applicator 12 x 18cm

BTL-6000 Shortwave
A New Generation in Shortwave Diathermy TECHNOLOGY

BTLdiathermy_CAT_EN201
sales@btlnet.com
www.btlnet.com

All rights reserved. Although every care has been taken to provide accurate and up-to-date information, no responsibility can be accepted
for any mistakes or misprints contained in this catalogue. The products and their specifications, as shown in this catalogue, may change
without notice.
TECHNOLOGY BTL-6000 SHORTWAVE FREEDOM OF MOVEMENT

The BTL-6000 Shortwave is a state-of-the-art device for high-frequency heat therapy. Intuitive operation via the touch-screen SIX JOINTED ARMS FOR ALL TREATMENT POSITIONS
From achillodynia to migraine
The use of high-frequency energy for heat therapy has the advantage of a greater penetration depth
in contrast with conventional methods, such as hot packs, baths, infrared light or even microwave
treatment.

The heating effect of the electrodes for the inductive and capacitive methods of application is
fundamentally different.

CAPACITIVE APPLICATORS

With the capacitive field method, the body part being treated is located in the high-frequency
electric field between two insulated electrodes. During the capacitive method of application, the
transformation of energy into heat takes place mainly in the tissues with low blood circulation (e.g.
fat layer and connective tissues). Therefore, the greater part of the heat is generated in areas near the
skin’s surface (upper-skin fat tissue). This, combined with the distance between applicator and skin, is
important in the patient’s sensation of heat.

INDUCTIVE APPLICATORS

The inductive field method produces high-frequency electric currents within the body tissue by means EASY TO START FULLY ADJUSTABLE
of induction. These currents will increase as the electric conductivity of the corresponding tissue 360° rotation in 2 joints
region, such as tissues with good blood circulation (e.g. muscle tissue and inner organs), increases. Pre-set therapy protocols
User-defined protocols
Patient database in the unit
FIELDS OF APPLICATION Encyclopaedia with applicator placement images
Rehabilitation
Orthopaedics
Neurology MAXIMAL POWER & SAFETY
Sport Medicine Due to the advanced automatic tuning system and
Dermatology (Wounds, burns and scars) patient safety-switch
Gynaecology
ENT
Internal Medicine
Urology

Two different models:


MOST COMMON INDICATIONS
BTL-6000 SHORTWAVE 400
FOR INDUCTIVE AND CAPACITIVE APPLICATIONS EASY APPLICATOR SWAPPING
Power up to 400W for optimal application Click in place, no screwing required
possibilities (200W continual)
One channel capacitive field
One or two channels inductive field
Colour touch-screen user-interface

Shortwave Diathermy
BTL-6000 SHORTWAVE 200
FOR INDUCTIVE APPLICATIONS
One or two channels inductive field
Continuous and pulsed mode
Colour touch-screen user-interface
Power up to 200W (100W continual)

You might also like