2. Technical Particulars
Characteristic Specification
Humidity
Wind
Seismic condition
Page 2.3
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.2 Equipment Overview
Feature Specification
2.2.2 Condenser
Feature Specification
Page 2.4
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.2.3 LP Heaters
Feature Specification
Extraction Flow at 41,469 kg/hr 44,353 kg/hr 90,854 kg/hr 56,525 kg/hr
100% Load
2.2.4 Deaerator
Feature Specification
Page 2.5
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
Storage Capacity Approx. 3 min.
2.2.5 HP Heaters
Feature Specification
Page 2.6
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.2.6 Generator
Feature Specification
Frequency 50Hz
2.2.7 Packaging
Feature Specification
Feature Specification
Page 2.7
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.3 Performance Guarantee and Acceptance Condition
Performance Guarantees shall apply to the steam turbine generator and shall be
achieved during Performance Testing conducted in accordance with this clause.
Liquidated damages associated with failure to achieve these Guarantees are
addressed in commercial proposal.
The Equipment is guaranteed on a “new and clean” basis for any and all tests.
Toshiba will include degradation and correction factors to be applied to correct for
degradation caused by equipment operation during startup and commissioning and
environmental conditions in Performance Test Procedures.
*1) *Regarding the Generator Electrical Output Guarantee, main steam flow shall be
available up to B-MCR flow with condensate measuring, not limited to the main steam
flow of guarantee heat balance.
Page 2.8
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.3.2 Gross Steam Turbine Generator Heat Rate
Measurement Value
Page 2.9
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
On completion of Thermal Performance Tests of the Steam Turbine Generator, the gross
turbine heat rate shall be determined (taking into account the agreed correction curves)
using the following relationships, unless otherwise agreed (Toshiba may propose any
adjustments in its submitted Test Procedure):
Where:
Page 2.10
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
-The following also apply to the performance data;
Performance is measured at the generator terminal less the electrical power supply
to the generator excitation system.
The properties of water and steam for the thermal performance of the STG Plant
are in accordance with the Steam Table of IAPWS-IF97.
TOSHIBA will provide test correction curves in a detailed site specific performance
test procedure during the commissioning phase of the project.
Performance test shall be conducted based on ASME PTC6 method with condensate
flow measuring. Details will be mutually discussed later.
Above performance is based on new and clean condition of the steam turbine. If
more than 8 weeks have elapsed since initial roll before a performance test is to be
conducted, aging correction shall be applied.
Page 2.11
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.3.3 Steam Turbine Generator and Auxiliary Equipment Auxiliary Power Consumption
This auxiliary power consumption is based on during normal operation at Rated Output
load. The equipments are listed as attachment. Please refer to Section9.1 G-02 “Auxiliary
power consumption list”.
Page 2.12
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.4 Steam Turbine and Auxiliaries
The following technical data is typical for the size and type of unit proposed and
except for that information specifically identified as being guaranteed, the data is
preliminary in nature and subject to change based on final equipment design and
component selection.
Measurement Value
Type TC4F-33.5”
HIP turbine
Page 2.13
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
Measurement Value
LP turbine
- stages 6 x 4flow
(4) Method of blade damping Loose shroud cover & loose lug and cover
Page 2.14
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.4.2 Near-Field Noise (1m from any surface of STG enclosure at turbine operating floor)
Under normal operation of the STG at 100% load, expected noise level is 85 dBA.
Some equipment noise operating levels exceed the 85dBA sound limit. Please see
the following table for noise level information.
MSV/CV 95 dBA
CRV 95 dBA
Notes:
Please note that noise levels can also be temporarily exceeded during transitional
states such as: start up, shutdown, turbine bypass operation, load reduction, etc.
Page 2.15
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.4.3 Heat Balance Diagrams
Page 2.16
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.4.4 Steam Turbine auxiliary technical data
The following technical data is typical for the size and type of unit proposed and
except for that information specifically identified as being guaranteed, the data is
preliminary in nature and subject to change based on final equipment design and
component selection.
Measurement Value
MSV/CV
- number 2
CRV
- number 2
- number 1
- number 1
- type centrifugal
- number 1
- type centrifugal
- number 1
- type centrifugal
Page 2.17
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
Measurement Value
Vapor extractor
- number 2 ( 100% x 2 )
- Type centrifugal
- number 2 ( 100% x 2 )
- Type Plate
Oil Conditioner
- number 1
Page 2.18
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
Measurement Value
- number 1
- number 2 ( 100% x 2 )
- Type centrifugal
- number 2 ( 100% x 2 )
- number 2 ( 100% x 2 )
- type Piston
Page 2.19
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.5 Condenser
The following technical data is typical for the size and type of unit proposed and
except for that information specifically identified as being guaranteed, the data is
preliminary in nature and subject to change based on final equipment design and
component selection.
Measurement Value
Cleanliness Factor 90 %
Page 2.20
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.6 Generator and Auxiliaries
Unless other standards are specifically mentioned in this proposal, all materials
used and provided under the Contract, all design calculations and tests shall be in
accordance with the following standards.
(a) Materials;
panels/racks
Page 2.21
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.6.2 Technical Data of Generator
Installation Indoor
No. of phase 3
Short circuit ratio Not less than 0.50 (at rated kVA base)
Cooling method
Connection of stator winding Wye. Both ends of each phase winding are
brought out from the generator stator through
high voltage bushings. Six(6) bushings are
provided for a generator.
Insulation class
Page 2.22
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
Generator electrical performance curves : Please refer to Sec. 9.
Page 2.23
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.6.5 Turbine and Generator Auxiliary Motors (AC motors)
Page 2.24
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.7 Control System
Please refer to Section 4.5 in this proposal for detailed technical specification.
Page 2.25
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.8 Required Utility Condition
The following data is typical for the volume and specification of unit proposed, the
data is preliminary in nature and subject to change based on final equipment
design and component selection.
Measurement Value
Measurement Value
Antifreeze agent No
Measurement Value
Page 2.26
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.8.4 Instrument air conditions
Measurement Value
Measurement Value
(AC)
(DC)
- Power 220V
Page 2.27
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved
2.8.6 Steam purity requirements
Normal operation
SiO2 < 20 ppb
Sodium < 3 ppb
Chlorine < 5 ppb
Cation Conductivity < 0.2 μS/cm
Excursions
100hr/incident and 500hr/year
Sodium < 6 ppb
Chlorine < 5 ppb
Cation Conductivity < 0.5 μS/cm
24hr/incident and 100hr/year
Sodium < 10 ppb
Chlorine < 50 ppb
Cation Conductivity < 1.0 μS/cm
Page 2.28
TOSHIBA CORPORATION
SPC-GPH-VLP1-0001 Rev.0
Proprietary Information
© Toshiba Corporation 2011, All Rights Reserved