PROJECT SHAHEEN Project

PLANT Steam Cracker & Polymer Complex (For Petrochemical Plant)


ADDENDUM FOR
ENGINEERING SPECIFICATION
FOR
PROPORTIONING PUMPS OF RECIPROCATING TYPE

SHAHEEN-COM-ME-SPC-1093
ES NO. GA-108

0 3-Jan-2022 M. Pawar P. Bam L. Wright Issued for Design

B 23-Nov-2021 H. Kulkarni P. Bam L. Rath Issued for Review

REV. DATE Prepared By Checked By Approved By Remark

© Copyright 2021 Worley ACN 096 090 158. No part of this document or the information it contains may be
reproduced or transmitted in any form or by any means electronic or mechanical, including photocopying,
recording, or by any information storage and retrieval system, without permission in writing from Worley.
Disclaimer
This document has been prepared on behalf of and for the exclusive use of S-OIL CORPORATION and is subject
to and issued in accordance with the agreement between S-OIL CORPORATION and Worley Europe Limited. Worley
Europe Limited accepts no liability or responsibility whatsoever for it in respect of any use of or reliance upon this
report by any third party. Copying this report without the permission of S-OIL CORPORATION or Worley Europe
Limited is not permitted.
ADDENDUM FOR ENGINEERING SPECIFICATION SHAHEEN-COM-ME-SPC-1093
FOR
Revision 0
PROPORTIONING PUMPS OF RECIPROCATING
SHAHEEN PROJECT TYPE PAGE 2 OF 4

*REVISION HISTORY SHEET*


REV.NO. DATE DESCRIPTION

B 23-Nov-2021 Issued for Review

0 3-Jan-2022 Issued for Design


ADDENDUM FOR ENGINEERING SPECIFICATION SHAHEEN-COM-ME-SPC-1093
FOR
Revision 0
PROPORTIONING PUMPS OF RECIPROCATING
SHAHEEN PROJECT TYPE PAGE 3 OF 4

ADDENDA
This Addenda to Engineering specification for Proportioning Pumps of Reciprocating Type
SHAHEEN-COM-ME-SPC-0093 latest revision, is prepared only to modify / delete / add clauses
of the specification, which may help in an effort to reduce the overall cost of the equipment.
Except for new paragraphs, the number and title of the paragraphs in following modifications to
SHAHEEN-COM-ME-SPC-0093 correspond to the respective sections and paragraphs of the
above standard. Paragraphs not addressed in this specification shall be strictly in accordance to
SHAHEEN-COM-ME-SPC-0093, Latest revision requirements.
The word in parenthesis following the number or title of a paragraph indicates following:

Terms or Symbol Definition


Addition - An amendment that adds text at the end of designated portion
of FEED specification
Deletion - An amendment that indicates a portion of FEED specification
that should be deleted
Exception - An amendment that replaces a designated portion of FEED
specification
Revision - An amendment that revises a limited amount of existing text in
FEED specification
Example 1:
(Revision) The value “3.5ft” shall now read as “3.2ft”
Example 2:
(Revision) The term “MAWP” shall now read as “Design
Pressure (DP)”.
- A line that indicates the beginning and end of an amendment
section
ADDENDUM FOR ENGINEERING SPECIFICATION SHAHEEN-COM-ME-SPC-1093
FOR
Revision 0
PROPORTIONING PUMPS OF RECIPROCATING
SHAHEEN PROJECT TYPE PAGE 4 OF 4

2. BASIC DESIGN

2.1 General

2.1.7 (Revision)
Vendor shall guarantee the pump performance, i.e., steady state accuracy, capacity, pressure
and Shaft power as specified on the datasheets. No negative tolerance is permitted on capacity
at rated speed and differential pressure. The steady state flow accuracy shall be as per vendor
standard.
Tolerance on shaft power shall be follows:

Driver Driver Rating (kW) Tolerance (%)


19 and less +10

Motor 22 to 55 +6
75 and more +4
Turbine - +4

2.2 Drivers and Gear Units

2.2.1 (Revision)

The motor nameplate rating be suitable for operation at 110% of the relief valve setting.