Open MSS 15, Product Documentation, version 6 (HTML) > Troubleshoot > Maintaining and Troubleshooting
Hardware > Replacing hardware units > Replacing the HDD on CPRT5-A for VMU
1
Install the HDD by mounting screws that hold the disk module to the carrier.
2
Align the HDD carrier to the guiding rails of the slot.
3
Insert the HDD carrier to the slot until it is firmly in place.
4
Tighten the two retaining screws of the HDD carrier.
5
Install the RTM with HDD.
http://localhost:9090/informationbrowser/topic/m172200157_html/htm/docs/troubleshooti... 6/13/2017
Installing the HDD Page 2 of 5
For the instructions on installing the RTM, see Install a rear transition module. in section Replacing a rear transition module.
Note: After a while, if the HDD0 is ready, the HDD0 ACT LED turns green.
6
Change the state of VMU to TE-EX.
Step example
ZUSC:VMU,12:SE;
ZUSC:VMU,12:TE;
Note: Upon command execution, the VMU unit restarts along with all its child units. After the restart, the state of the VMU
unit is changed to TE-EX.
7
Change the state of VMU to WO-EX.
Step example
ZUSC:VMU,12:WO;
Note: Upon command execution, the VMU unit restarts along with all its child units. After the restart, the state of the VMU
unit is changed to WO-EX. The child units of the VMU unit resume their initial state ( for example SP-EX or WO-EX).
8
Check the state of the HDD.
Step example
ZISI:,CHU,1:WDU,0:;
9
If the hard disk is a new one, initialize it.
Sub-steps
a)
Change the state to WO-ID.
Step example
ZISC:,CHU,1:WDU,0:WO-ID;
b)
Initialize the disk.
http://localhost:9090/informationbrowser/topic/m172200157_html/htm/docs/troubleshooti... 6/13/2017
Installing the HDD Page 3 of 5
Step example
ZIWI:,CHU,1:WB,F5,MSS_CHU1W0,FFF0,2,XY;
10
Check the version of the unit's IPMI software.
Check whether the soft versions are consistent. If they are consistent, no upgrade is required. If they are inconsistent, an upgrade is
needed.
Step example
WDD:UT=VMU,UI=12;
EXECUTION STARTED
COMMAND EXECUTED
Step result
As displayed in the example, an upgrade is not needed because the current SW version is consistent with the disk version.
11
Update the IPMI software, if needed.
Note: Update must be performed by an experienced person who has sufficient knowledge of the system. For instructions,
see command reference.
Sub-steps
a)
Check the slot of CHU. Get the master and the module number of the related VMU.
Step example
ZWTI:P:CHU;
b)
Check all child units in the VMU.
Step example
ZUSI:VMU,index;
http://localhost:9090/informationbrowser/topic/m172200157_html/htm/docs/troubleshooti... 6/13/2017
Installing the HDD Page 4 of 5
c)
Change all related child units to TE-EX.
Step example
12
Change the state of the HDD to TE-ID.
Step example
ZISC:,CHU,1:WDU,0:TE-ID;
13
Run the diagnostic on the unit.
Step example
ZUDD:CHU,1,1:WDU,0;
14
Check the diagnostic report.
Step example
ZUDH:CHU,1,1:;
15
Change the working state of the HDD back to WO-ID.
Step example
ZISC:,CHU,1:WDU,0:WO-ID;
16
Copy source WDU to backup WDU of CHU unit.
Step example
ZIWY:S:UNIT=CHU-1,PATH=/,DRIVE=WDU-S;
ZIWY:D:UNIT=CHU-1,PATH=/,DRIVE=WDU-B;
ZIBC:,,,,,,,,,DIR:;
http://localhost:9090/informationbrowser/topic/m172200157_html/htm/docs/troubleshooti... 6/13/2017
Installing the HDD Page 5 of 5
Step example
ZISC:,CHU,1:WDU,0:WO-BU;
18
Check that there are no active alarms.
Step example
ZAHO:CHU,1;
ZAHO:WDU,0;