SN-IND-1-032 VT System For Smart Charge Communication
SN-IND-1-032 VT System For Smart Charge Communication
2022-05-25
Table of contents
Symbol Utilization
This icon gives you step-by-step instructions.
This icon indicates notes and tips that facilitate your work.
2 Overview
This Support Note describes how to configure CANoe and the VT System for Smart Charging
Communication.
SN-IND-1-032_VT_System_for_Smart_Charge_Communication.pdf Page 1
VT System for Smart Charge Communication
Be sure, you have installed the latest CANoe version with option SmartCharging.
Another CANoe option is needed for the specific standard that is used, see Smart Charging
Requirements.
3 Wiring settings
3.1 Wiring with VT6000 series real-time module:
Page 2
VT System for Smart Charge Communication
The Ethernet RJ45 connector on board is used for the connection to the PLC chip (Power Line
Communication), see also chapter 5.4.
1) To observe the Smart Charging communication between an EV and EVSE in your CANoe
simulation in the "real mode" (see also chapter 7)
In the following chapter 3.3.x is explained how to connect the RJ45 Ethernet cable.
Hint 1
If you simulate the Smart Charging communication between an EV and EVSE in the "simulated mode"
you don't need the RJ45 Ethernet connection. Use the sample "SmartChargingBasic.cfg".
Hint 2
You can use the CCS Listener VH5110 if you use two VT modules (EV/ EVSE) and both PLC chips
are connected using an Ethernet cable. See KnowledgeBase article How to Connect the VH5110.
Page 3
VT System for Smart Charge Communication
> Optional: Use the VT6306 Ethernet network module (PCIe) or VN5000 series interface
(with USB 2.0) to your VT6000 real-time module
> Use a generic Ethernet network card (1G Ethernet port / 10G Ethernet port)
> Connect it with an Ethernet cable to your VT7870/VT7970/VT7971 module
> Optional: Use the VT6306 Ethernet network module (PCIe) or VN5000 series interface
(with USB 3.0) to your VT6000 real-time module
Page 4
VT System for Smart Charge Communication
To be able to see the Ethernet communication, you have to connect the Ethernet port to another
Ethernet adapter that is connected to your computer. This can be a Vector VN5000 series interface
such as VN5610A or a generic USB-to-Ethernet adapter.
Please compare your CANoe version and used interface on the list and find a matching combination:
CANoe < 12.0 SP3 VN5610(A), VN5640, generic network card, channel-based
VN8900 family Ethernet port
CANoe 12.0 SP4 to VN5610(A), VN5640, generic network card, channel-based
CANoe 14 SP0 VN8900 family Ethernet port
CANoe 12.0 SP4 to VN5430, VN5610(A), VN5620, VN5640, VT6306* port-based
CANoe 12.0 SP5
CANoe 13.0 SP0 to VN5240, VN5430, VN5610(A), VN5620, VN5640, port-based
CANoe 14 SP1 VT6306*
CANoe > 14 SP2 VN5240, VN5650, VN5430, VN5610(A), VN5620, channel-based or
VN5640 generic network card, VN8900 family port-based
Ethernet port, VT6306*
*The VT6306 Ethernet network module is normally used together with the VT6000 real-time module.
Generic network card: If you are using a generic network card, please see the article Ethernet Vector
Network Driver with CANoe.
Channel-based:
If you are using a Vector VN5000 family interface, you must assign CANoe Ethernet1 to the physical
channel of the interface, which is connected with the VT7870/7970/7971:
Page 5
VT System for Smart Charge Communication
Please note that the first listed channel is the physical channel which is labeled with "Eth1" on your
interface.
Network-based:
If you are using a Vector VN5000 family interface, you have to configure the interface and the CANoe
configuration first. Please see the article Migrate Configuration to Network-Based Concept Manually.
Channel-based:
Network-based:
To use the generic network card of your VT6060/VT6020 module you need to activate the "Vector
Network Driver". After this step, the Ethernet network card is detected automatically, or you could
select it manually in the "Application Channel mapping" in CANoe. The transceiver name of your
generic network card is displayed and the status of the channel lights up "green".
Page 6
VT System for Smart Charge Communication
> Under Control Panel | Network and Internet | Network Connections | right mouse click on
the used generic Ethernet card
> Select the Vector network adapter which is connected to your VT7870/VT7970/VT7971
module and check “Vector Network Driver”
Page 7
VT System for Smart Charge Communication
CANoe application:
Select the used generic network card "Network Hardware Configuration - RT Server VT6020"
The "Vector Network driver" version is also displayed.
Network-based mode:
If the generic network card can't be selected manually or automatically in the "Application Channel
mapping" and the "Vector Network driver" version is 2.1.9 you need to update the driver.
4 Connection settings
For communication between VT7870/VT7970/VT7971 and VN5000 family series, the CANoe IP stack
must be configured manually.
Also, the IPv4 or IPv6 addresses must be configured manually if not specified by the OEM. For IPv4, a
static IP address has to be specified if no DHCP server in the network is available. For IPv6, a static or
stateless IP address has to be set, if no DHCP server is available in the network.
Page 8
VT System for Smart Charge Communication
4.1.1 Wiring of Control Pilot (CP), Protective Earth (PE), Proximity Pin (PP) and PWM
On the backside of the VT7900(A) module you can connect to the opposite site for measurement and
communication purpose:
Page 9
VT System for Smart Charge Communication
Without using VT6000 no IP settings are needed for the communication between the PC and
the VT backplane, because the communication protocol is EtherCAT .
Page 10
VT System for Smart Charge Communication
> Go to Extensions | VT System and choose the Ethernet adapter you use for
communication with the VT System
Page 11
VT System for Smart Charge Communication
> Open the VT System Configuration and add the VT7900(A) with the application
board VT7870/VT7970/VT7971 to your configuration
> Adapt your configured VT System modules to the physical available VT System
modules by clicking on Adapt to connected HW… and after that Scan and Auto
Match.
Page 12
VT System for Smart Charge Communication
> Please note that you have to connect to the VT6000 series module (CANoe
Options -> Extensions -> CANoe RT) first, when you are using it.
Page 13
VT System for Smart Charge Communication
> Go to Extensions | VT System and choose the Ethernet adapter you use for
communication with the VT System
> Open the VT System Configuration and add the VT7900(A) with the application
board VT7870/VT7970/VT7971 to your configuration
Page 14
VT System for Smart Charge Communication
Page 15
VT System for Smart Charge Communication
5.4 Switching relay of VT7870/7970/7971 for CP, PE, PP, PWM etc.
To activate the connected wires (CP, PE, PP, PWM etc.), you need to close the corresponding relay in
the VT System Control by clicking on the blue boxes:
The relay can also be switched via CAPL, C# or VB.NET. By switching the relay, the function will be
shown in the code generator at the bottom of the VT System Control:
Page 16
VT System for Smart Charge Communication
> Read from device to check that the settings have been written successfully
To get a connection to the VT7870/VT7970/VT7971, please connect your computer directly
to the Ethernet port on the VT7870/VT7970/VT7971 and configure any IP address and
subnet mask. You can find the configuration tool in your CANoe installation folder in the
subfolder Exec32 or on the Vector homepage.
For CANoe versions under CANoe 12.0, the name of the configuration tool in the Exec32
folder is QCAConfigurator.exe, for later versions GreenPHYConfigurator.exe
(download).
To be able to start the “GreenPHY Configurator” tool the NPcap driver or WinPcap should be installed
on your computer (see https://nmap.org/npcap/ or https://www.winpcap.org/install/).
Page 17
VT System for Smart Charge Communication
7 Use cases
Page 18
VT System for Smart Charge Communication
8 FAQ
Question:
How can I change the firmware of my VT7870/VT7970/VT7971?
Answer:
QCA Configurator since version 1.4.0 (SCC Package 2.0.1) or the GreenPHY Configurator
(from CANoe 12.0).
Question:
Where can I find the VT7870/VT7970/VT7971 manual?
Answer:
Windows Start Menu | CANoe | Add-on Smart Charging Communication (Only if SCC Package
is installed). In CANoe 12.0 and later versions in the CANoe installation folder in the subfolder
“docs”.
Question:
I need the pin assignment/wiring diagram. Where can I find it?
Answer:
Both can be found in the VT7870/VT7970/VT7971 manual or in the VT System Control in
CANoe.
Question:
Where do I have to connect the VN5000 family interface to use it with the VT System?
Answer:
> With VT6000 series module: At the USB port of the VT6000 series module itself.
> Without VT6000: On the CANoe PC.
Question:
Can I just listen to the communication between EVSE and EV? (Spymode)?
Answer:
> Yes, but then you need two VT7900(A)/VT7870/VT7970/VT7971 modules to listen to the
communication (also known as "man-in-the-middle" method).
> Alternatively use the VH5110 which is more suitable and replaces the “man-in-the-middle”
method.
Question:
Can the option SmartCharging be used in vTESTstudio?
Answer:
Yes. For this, the modeling library (nodelayer DLL) must be implemented in the CANoe
configuration. For use with vTESTstudio, the option .SmartCharging DLL must be assigned in the
vTESTstudio project under modeling libraries.