Download as pdf or txt
Download as pdf or txt
You are on page 1of 124

A U T O M A T I O N & C O N T R O L

Irrigation Catalog

AGRICULTURE

Tackling climate
change together
A U T O M A T I O N & C O N T R O L

Irrigation
INDEX

CERTIFICATION ............................................................................................ 4
SOLENOID VALVES ..................................................................................... 7
SOLENOID MANIFOLDS ............................................................................ 29
ISOLATED / FERTILIZER SOLENOIDS .................................................. 33
ELECTRIC & HYDRAULIC VALVES........................................................ 41
ELECTRIC & HYDRAULIC VALVES | G500 ........................................ 65
CONTROLLERS & SPECIAL VALVES.................................................... 81
OPERATORS & COILS ............................................................................... 101
TECHNICAL INFORMATION ..................................................................... 113

Tackling climate
change together
CERTIFICATION

CERTIFICATE CERTIFICATE
This is to certify that the Environmental Management System of
This is to certify that the Quality Management System of
BACCARA GEVA AGRICULTURE COORPORATION BACCARA GEVA AGRICULTURE COORPORATION
SOCIETY LTD. SOCIETY LTD.
Kibbutz Geva, Israel Kibbutz Geva, Israel
Has been assessed and complies with the requirements of : Has been assessed and complies with the requirements of :

ISO 001:2015 ISO 14001:2015


This Certificate is Applicable to This Certificate is Applicable to

Design, production and marketing of solenoid valves and automation control equipment. Design, production and marketing of solenoid valves and automation control equipment.

Initial Approval: 01/10/199 Initial Approval: 03/01/2010


Issue Date: 27/12/2019 Issue Date: 27/12/2019
Valid Until: 27/12/2022 Certificate No.: 97540 Valid Until: 27/12/2022 Certificate No.: 97543

SII-QCD assumes no liability to any party other than the client, and then only in accordance with the agreed upon Certification Agreement. SII-QCD assumes no liability to any party other than the client, and then only in accordance with the agreed upon Certification Agreement.
This certificate’s validity is subject to the organization maintaining their system in accordance with SII-QCD requirements for system certification. The This certificate’s validity is subject to the organization maintaining their system in accordance with SII-QCD requirements for system certification. The
continued validity may be verified via scanning the code with a smartphone, or via website www.sii.org.il. This certificate remains the property of SII-QCD. continued validity may be verified via scanning the code with a smartphone, or via website www.sii.org.il. This certificate remains the property of SII-QCD.

Avital Weinberg Avital Weinberg


R.N 570041970 Director, Quality & Certification Division R.N 570041970 Director, Quality & Certification Division
Page 1 of 1 Our Vision: To Enhance Both Global Competitiveness of our Services, with our Uncompromised Quality and Integrity Page 1 of 1 Our Vision: To Enhance Both Global Competitiveness of our Services, with our Uncompromised Quality and Integrity

ISO 9001:2015 ISO 14001:2015


Quality Management System: Design, production, Environmental Management System: Design,
testing and marketing of solenoid valves and production, testing and marketing of solenoid
automation control equipment valves and automation control equipment

This is to certify that the


CERTIFICATE ccupational Health and Safety Management Systems of
BACCARA GEVA AGRICULTURE COORPORATION
SOCIETY LTD.
Kibbutz Geva, Israel
Has been assessed and complies with the requirements of :
ISO 45001:201
This Certificate is Applicable to

Design, production and marketing of solenoid valves and automation control equipment.

Initial Approval: 30/0 /2010


Issue Date: 1 /12/2019
Valid Until: 1 /12/2022 Certificate No.: 107 30

SII-QCD assumes no liability to any party other than the client, and then only in accordance with the agreed upon Certification Agreement.
This certificate’s validity is subject to the organization maintaining their system in accordance with SII-QCD requirements for system certification. The
continued validity may be verified via scanning the code with a smartphone, or via website www.sii.org.il. This certificate remains the property of SII-QCD.

Dr. Gilad Golub Avital Weinberg


CE R.N 570041970 Director, Quality & Certification Division
Page 1 of 1 Our Vision: To Enhance Both Global Competitiveness of our Services, with our Uncompromised Quality and Integrity

ISO 45001:2018 EN55011 Group1 –


Occupational Health & Safety Management System: Class A / EN61000-6-1 / CFR 47 FCC Class A
Design, production, testing and marketing of solenoid EMC - SII Certificate of Conformity
valves and automation control equipment

CE RTIFICATE O F CO MPLIANCE
Certificate Number 20190911- M H 12494
Report Reference M H 12494- 198 50305
Issue Date 2019- S E P T E M B E R - 11

Issued to: B A C C A R A G E V A A G R IC U L T U R E C O R P O R A T IO N
S O C IE T Y L T D
K IB B U T Z G E V A
18 915 K V U T Z A T G E V A , I S R A E L

This certificate confirms that C o m p o n e n t - V a lv e s , E le c tr ic a lly O p e r a te d


representative samples of (S e e A d d e n d u m f o r A d d i t i o n a l I n f o r m a t i o n .)

H a v e b e e n in v e s t ig a t e d b y U L in a c c o r d a n c e w it h t h e
c o m p o n e n t r e q u ir e m e n t s in th e S t a n d a r d ( s ) in d ic a te d o n
t h is C e r t if ic a t e . U L R e c o g n iz e d c o m p o n e n t s a r e in c o m p le te
in c e r ta in c o n s tr u c tio n a l f e a tu r e s o r r e s tr ic te d in
p e r f o r m a n c e c a p a b ilit ie s a n d a r e in t e n d e d f o r in s t a lla t io n in
c o m p le t e e q u ip m e n t s u b m itt e d f o r in v e s t ig a t io n to U L L L C .

Standard(s) for Safety: U L 429, 5t h E d i t i o n , E l e c t r i c a l l y O p e r a t e d V a l v e s


Additional Information: S e e th e U L O n lin e C e r tif ic a tio n s D ir e c to r y a t
h t t p s : //i q .u l p r o s p e c t o r .c o m f o r a d d i t i o n a l i n f o r m a t i o n .

T h i s Certificate of Compliance d o e s n o t p r o v i d e a u t h o r i z a t i o n t o a p p l y t h e U L R e c o g n i z e d C o m p o n e n t M a r k .

O n ly th o s e p r o d u c ts b e a r in g th e U L R e c o g n iz e d C o m p o n e n t M a r k s h o u ld b e c o n s id e r e d a s b e in g U L C e r tif ie d
and covered under UL’s Follow- U p S e r v i c e s .

L o o k fo r th e U L R e c o g n iz e d C o m p o n e n t M a r k o n th e p r o d u c t.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

P a g e 1o f 2

UL 429 CE
Standard for electrically operated valves EC Declaration of Conformity
Available on selected models only Complies with the requirements and provisions
of the Council Directive 2014/35/EU
Available on selected models only

4 A U T O M A T I O N & C O N T R O L
AGRICULTURE

FCC NSF/ANSI 61 & 372 *


Product certification from The Federal NSF/ANSI 61 & 372 and all applicable requirements
Communications Commission Drinking Water System Components:
Available on selected models only Lead Content | Health Effects
Available on selected models only

For details of all NSF certified Baccara products, please take


the following steps:
• Visit NSF Public Health & Safety Organization: www.nsf.org
• Click on SEARCH CERTIFIED PRODUCTS & SYSTEMS >>
• Type "Baccara" in the "search company" field > Enter
AS/NZS 4020

Australian
Water
Quality
Centre
AS/NZS 4020:2005 *
Certificate of Conformity: Testing of products for
use in contact with drinking water
Available on selected models only

* For enquiries regarding this certification, please contact BACCARA sales engineers at water@baccara-geva.com

Tackling climate
change together 5
A U T O M A T I O N & C O N T R O L
SOLENOID VALVES

GEM-FLOW™ | G75-A3P 1/8” Latch 2 Way, 3 Way NC, NO ..................................................................................... 8


GEM-FLOW™ | G75-VSA 1/8” Stand-alone Solenoid 3 Way NC, NO ................................................................... 10
GEM-FLOW™ | G75-P 1/4” 3 Way Pilot Operated NC, NO .................................................................................. 12
GEM-FLOW™ | G75-A 1/8”, 1/4” 2 Way, 3 Way NC, NO .......................................................................................... 14
GEM-FLOW™ | GALIT 1/8” 3 Way Pilot Operated NC, NO .................................................................................. 16
GEM-SOL® | GEM-A 1/8”, 1/4” 2 Way NC, NO ......................................................................................................... 18
GEM-SOL® | GEM-A 1/8”, 1/4” 2 Way NC, NO ......................................................................................................... 20
GEM-SOL® | GEM-A 1/8”, 1/4” 3 Way NC, NO ......................................................................................................... 22
GEM-SOL | GEM-A
®
1/8”, 1/4” 3 Way NC, NO ......................................................................................................... 24
GEM-SOL® | GEM-A3P 1/8”, 1/4” Latch 3 Positioning Manual Override, 2 Way, 3 Way NC, NO ........... 26

Tackling climate
change together
SOLENOID VALVES

GEM-FLOW™ | G75-A3P
1/8” Latch 2 Way, 3 Way NC, NO

Technical Data
Function 2 Way NC, 3 Way NC, NO
Ports size 1/8” BSP & NPT
Orifice size 2.6 mm
NC 2 Way: 10 bar
Pressure range NC 3 Way: 8 bar
NO 3 Way: 10 bar
Fluid: 5ºC to 50ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
Manual override:
Plastic (Reinforced Nylon)
NO: Red
NC: Green
Materials in contact Main Valve:
with media UV Stabilized - Reinforced Nylon 6 30% GF
Solenoid Operator:
Stainless Steel AISI 300 & 400 series
Seals:
NBR
Mounting 2 x Ø6 mm holes
Manual override 3 positions (Open/Auto/Close)
Media Air, water
Coil voltage Latch
Switching time 40-60 msec
Electric connection 22AWG cable
Standard protection class IP66
* Can only be operated with supplied coil
* Available with a manifold bracket upon request.
Please contact our technical sales department

Latch Coil Resistance vs Input Voltage


Recommendations chart
NO NC
Resistance [Ω] Input voltage range [V] IN IN
1 8 - 12
4 12 - 18
9 18 - 24

OUT EX NC
NC/NO

IN NC OUT NC EX NO
(2) (1) (2) (1)
2 Way 3 Way

8 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G75-A3P | 1/8” Latch 2 Way, 3 Way NC, NO

Dimensions

Manual Override Operation

OPEN

89.9
1/8'' BSP / NPT
CLOSE
80

TYPx3 1/8" BSP \ NPT


TYPX3

AUTO
62.6 50
62.6 50
6 6
THROUGH THROUGH
TYPx2 TYPX2
To manually open the valve:
turn selector switch to OPEN
25
25

15
15

NO: To change from OPEN to AUTO:


turn the selector switch to AUTO
NC: To change from OPEN to AUTO:
23 6 23 6 turn the selector switch to CLOSE,
and then to AUTO
2W 3W

25
9.30

16.82

62

Mounting Bracket
Can be ordered separately
PN 5940610527

How to Order
G75-A3P - TYPE PORT FUNCTION (1) ORIFICE - LATCH TYPE (2) WIRES

with flange 1 1/8" BSP 10 2W NC 1 2.6 5a 1Ω PA two Null


1/8" NPT 11 3W NC 3 4Ω PB three a
3W NO 4 9Ω PC

Example: G75-A3P-11015a-PA
G75-A3P, with flange, 1/8"BSP, 2W NC, 2.6 orifice, 1Ω latch with two wires

G75-A3P 1 10 1 5a PA

(1) To order NC configuration, please consult with our technical sales department
(2) Refer to Latch Coil Resistance vs Input Voltage Recommendations chart

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 9
SOLENOID VALVES

GEM-FLOW™ | G75-VSA
1/8” Stand-alone Solenoid 3 Way NC, NO

Technical Data
Function 3 Way NC, NO
Ports size 1/8” BSPT & NPT
Orifice size 1.8 mm
Pressure range 0 to 8 bar
Switching time 30-50 ms
Fluid: 0ºC to 50ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
Manual override:
Plastic (Reinforced Nylon)
Main Valve:
Materials in contact Plastic (Reinforced Nylon & POM)
with media Solenoid Operator:
Stainless Steel AISI 300 & 400 series
Seals:
EPDM
Mounting Lock nut on the bottom COM port
Latch: 3 position latch: Auto, Close, Open
Manual override
AC: 2 position: Auto, Open
Media Air, water
Coil voltage Latch, AC (according to table)
Standard protection class IP66
* Can only be operated with supplied coil

PORT NO NC
1 Exhaust Pressure
3 Pressure Exhaust
COM Out Out

COM 1

Voltage & Current


(1)
AC & DC
Solenoid Inrush [A] Holding [A]
24VAC-50 Hz 0.33 0.21 (3)

Latch Coil Resistance vs Input Voltage


Recommendations chart COM 2

Resistance [Ω] Input voltage range [V]


4 6-9
9 12 - 14
12 14 - 16
23 18 - 21

10 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G75-VSA | 1/8” Stand-alone Solenoid 3 Way NC, NO

Dimensions
Manual Override Operation

NO NC

OPEN OPEN

1/8" BSPT \ NPT


CLOSE CLOSE
119

1/8" BSPT \ NPT

AUTO
1/8" BSPT \ NPT AUTO

44 58.2
13

1/8" BSPT \ NPT


57
1/4" BSPT

How to Order
MANUAL
G75-VSA - BODY PORT FUNCTION
OVERRIDE
ORIFICE SEALS - TYPE OUTLET (3) WIRES

Plastic 4 1/8" BSPT 10 3W NC 3 Plastic 1 1.8 3a EPDM E 24VAC-50Hz (1) S1 COM 1 1 two Null
1/8" NPT 11 3W NO 4 4Ω (2) SB COM 2 2 three (4) a

9Ω (2)
SC
12Ω (2) SD
23Ω (2) S6

Example: G75-VSA-410313aE-SB1
G75-A stand-alone solenoid, plastic, 1/8" BSPT, 3W NC, plastic manual override,
1.8 orifice, EPDM seals, 4Ω latch, COM 1 outlet, two wires

G75-VSA 4 10 3 1 3a E SB 1

(1) Refer to Voltage & Current AC & DC


(2) Refer to Latch Coil Resistance vs Input Voltage | Recommendations chart
(3) A plug will be fitted on the other outlet port
(4) Latch only

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 11
SOLENOID VALVES

GEM-FLOW™ | G75-P
1/4” 3 Way Pilot Operated NC, NO

Technical Data
Function 3 Way NC, NO
Ports size 1/4" BSP & NPT
Orifice size 6.5mm
Pressure range 0.5 to 10 bar
Fluid: 5ºC to 50ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
Main Valve:
Plastic (Reinforced Nylon)
Solenoid Operator:
Materials in contact Stainless Steel 300 & 400 series
with media Seals:
NBR
Spring:
Stainless Steel AISI 300 series
Manual override with 2 positions:
Manual override • AUTO - for automatic operation
• MANUAL - for manual operation
Solenoid Assembled with 3 Way NO 1.2mm G75 operator
Coil voltage • Voltage and power consumption - see table
Standard protection class IP66
* Available with a manifold bracket upon request.
Please contact our technical sales department

Voltage & Current Pilot In Pilot In

AC & DC
Solenoid Voltage Inrush [A] Holding [A]
3 Way 24VAC
+10% 0.125 0.125
50/60 Hz *
DC
V n-20% 4.5W

* Except 24V AC without Diode

Voltage & Power Consumption Valve


2
G7
5P 1
In Valve
2
G7
5P
1
EX

AC (W) 3 3
DC (W)
50 Hz
V 2 4.5 EX In
12 • •
24 • • NC NO
* Available options
Hydraulic Connections

Latch Coil Resistance vs Input Voltage


Recommendations chart
Resistance [Ω] Input voltage range [V]
4 6-9
9 12 - 14
12 14 - 16
23 18 - 21

12 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G75-P | 1/4” 3 Way Pilot Operated NC, NO

Dimensions G1/8
131 mm

MANUAL OVERRIDE MANUAL OVERRIDE


AUTO MODE MANUAL MODE
42 mm

G1/4

G1/2 *
48 mm 48 mm

* Inner thread : G1/4

TO CHANGE MANUAL OVERRIDE


FROM AUTO TO MANUAL MODE : 15mm 6.30mm
• Push in knob and turn to the right
25

G1/8

26mm
9.30

16.82

62

Mounting Bracket
Can be ordered separately
PN 5940610527

How to Order
G75-P - PORT VOLTAGE (1)
WIRES

1/4" BSP 20 24V AC 1 two null


24V AC
1/4" NPT 21 1R three (2) a
w/out Diode
12V AC 3
12V DC 4
24V DC 5
23Ω 6
4Ω B
9Ω C
12Ω D

Example: G75-P-2011
G75-P pilot operated, 1/4" BSP, 24V AC
with mounting bracket, two wires

G75-P 20 1 1

(1) For Latch: Refer to Latch Coil Resistance vs Input Voltage |


Recommendations chart
(2) For Latch only

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 13
SOLENOID VALVES

GEM-FLOW™ | G75-A
1/8”, 1/4” 2 Way, 3 Way NC, NO

Technical Data
Function 2 Way, 3 Way NC, NO
Ports size 1/8" and 1/4" BSP & NPT
Orifice size See table
Pressure range See table
Fluid: 5ºC to 50ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
Manual override:
Plastic (Reinforced Nylon)
Main Valve:
Materials in contact Brass or Plastic (Reinforced Nylon)
with media Solenoid Operator:
Stainless Steel AISI 300 & 400 series
Seals: G75-A G75-A | 2 Way G75-A | 3 Way
EPDM Plastic
Brass Plastic
Coil voltage • Voltage and power consumption - see table
Standard protection class IP66
* Available with a manifold bracket upon request.
Please contact our technical sales department

Latch Coil Resistance vs Input Voltage NC EX NO IN

Recommendations chart
Resistance [Ω] Input voltage range [V]
4 6-9
9 12 - 14
12 14 - 16
23 18 - 21

Max. Pressure (bar) NC/NO


OUT
NC IN
NO Exhaust

Function Orifice (mm) AC DC DC Latch


(2) (1)
2 Way NC up to 2.0 12 12 12

1 16 12 16

3 Way NC 1.2 11 9 11

1.6 6 5 6

1.0 16 16 16

3 Way NO 1.2 12 12 12

1.6 10 10 10

Voltage & Current Voltage & Power Consumption


AC & DC AC (W)
DC (W)
Solenoid Voltage Inrush [A] Holding [A] 50 Hz
2 Way 50 Hz 0.3 0.19 V 2 4.5
2 Way 60 Hz +10% 0.2 0.14 12 • •
3 Way 50/60 Hz * n-20% 0.125 0.125 24 • •
DC 4.5W
110 •
* Except 24V AC without Diode 2 Way only

* Available options

14 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G75-A | 1/8”, 1/4” 2 Way, 3 Way NC, NO

Dimensions
M 5 x 0 . 8 DEEP 8 Ø 6 THRU
TY P x 2 TY P x 2 F o r ta p p in g s c r e w
N o . 6
A B C
2 Way NC - 59 65
3Way 1/8 70 77
2 2

15
2 5
37
15

15
2 2
2 0 7 .3

C ABL E L EN GTH
35 0 (m m ) Ø 30

Ø 30
A A
C

B
B

M a n u a l
O v e r r id e
1/8 " BS P /N P T 1/8 " BS P /N P T
BO TH EN DS BO TH EN DS
2 5

1/8 " o r 1/4" 32


BS P /N P T
TY P x 2 48 . 3 35 . 8

Brass Plastic

How to Order
MANUAL
G75-A - TYPE PORT FUNCTION
OVERRIDE
ORIFICE - VOLTAGE (3) WIRES

with flange 1 1/8" BSP 10 2W NC 1 None 0 1.0 (1)


1 24V AC 1 two null
24V AC
Brass 3 1/8" NPT 11 3W NC 3 Plastic (2)
1 1.2 2 1R three (5)
a
w/out Diode (4)
1/4" BSP (1)
20 3W NO 4 1.6 3 12V AC 3
1/4" NPT (1)
21 2.0 (1) 4 12V DC 4
24V DC 5
23Ω 6
110V AC 7

4Ω B

9Ω C

12Ω D

Example: G75-A-110302-1
G75 with flange, 1/8" BSP, 3W NC, no manual override,
1.2 orifice, 24V AC coil, two wires

G75-A 1 10 3 0 2 1

(1) Brass only


(2) Recommended for AC and continuous DC only
(3) For Latch: Refer to Latch Coil Resistance vs Input Voltage |
Recommendations chart
(4) 3W NO 1.6 mm: Max pressure is 8 bars
(5) For Latch only

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 15
SOLENOID VALVES

GEM-FLOW™ | GALIT
1/8” 3 Way Pilot Operated NC, NO

Technical Data
Function 3 Way NC, NO

Ports size 1/8" BSP & NPT

Orifice size 5mm

Pressure range 1 to 10 bar

Fluid: 5ºC to 50ºC (no freezing)


Temperature range
Ambient: -10ºC to 50ºC
Main Valve:
Plastic (Reinforced Nylon)
Solenoid Operator:
Materials in contact Stainless Steel 300 & 400 series
with media Seals:
NBR
Spring:
Stainless Steel AISI 300 series
Manual override with 3 positions:
• AUTO - for automatic operation (valve is
Manual override open when solenoid is energized)
• MANUAL - valve is kept open
• CLOSE - valve is kept closed

Solenoid Assembled with 3W NO 1.2mm G75 operator

Coil voltage • Voltage and power consumption - see table

Standard protection class IP66

* Available with a manifold bracket upon request.


Please contact our technical sales department

Voltage & Current


AC & DC
Solenoid Voltage Inrush [A] Holding [A]
2 Way 50 Hz 0.3 0.19
+10%
V
2 Way 60 Hz 0.2 0.14
3 Way 50/60 Hz * n-20% 0.125 0.125
DC 4.5W
* Except 24V AC without Diode

Voltage & Power Consumption Latch Coil Resistance vs Input Voltage


AC (W) Recommendations chart
DC (W)
50 Hz Resistance [Ω] Input voltage range [V]
V 2 4.5
4 6-9
12 • •
9 12 - 14
24 • •
* • Available options 12 14 - 16
23 18 - 21

16 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | GALIT | 1/8” 3 Way Pilot Operated NC, NO

Dimensions IN
1/8" BSP / NPT

3W NO 3W NO
Ø1.2 Ø1.2

AUTO
151

OPEN CLOSE

EX N.O 2 4 OUT
IN N.C

56 33

IN N.O
EX N.C

How to Order
MOUNTING
GALIT - PORT VOLTAGE (1)
BRACKET
WIRES

1/8" BSP 10 24V AC 1 without 0 two null


1/8" NPT 11 24V AC 1R with 1 three (2)
a
w/out Diode
12V AC 3
12V DC 4
24V DC 5
23Ω 6
4Ω B
9Ω C
12Ω D

Example: GALIT-1011
GALIT pilot operated, 1/8" BSP, 24V AC
with mounting bracket, two wires

GALIT 10 1 1

(1) For Latch: Refer to Latch Coil Resistance vs Input Voltage |


Recommendations chart
(2) For Latch only

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 17
SOLENOID VALVES

GEM-SOL® | GEM-A
1/8”, 1/4” 2 Way NC, NO

Technical Data
Function 2 Way NC, NO
Ports size 1/8" and 1/4" BSP & NPT
Orifice size See table
• See table
Pressure range • Valves for pressure higher than 25 bar
cannot be supplied with manual override
Kv (l/min) See table
Fluid: -10ºC to 80ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
Manual override:
Plastic (Reinforced Nylon), Brass screw
or Brass finger knob, Stainless Steel for
Stainless Steel valves GEM-A | 2 Way GEM-A | 2 Way
(1) Plastic manual override: Stainless Steel Brass
Maximum pressure: 16 bar
Materials in contact (2) Manual override is unavailable in
with media 2 Way NO through base applications
Main Valve:
Brass or Stainless Steel AISI 316
Solenoid Operator:
Stainless Steel AISI 300 & 400 series
Seals:
NBR, FKM, EPDM, FFKM, PTFE
Media Air, water, oil
• Voltage and power consumption - see table
Coil voltage
• All Baccara coil voltages are ± 10% of nominal
IP65 with connector
Standard protection class
* Option: IP68 (please refer to GEM-BP Coil)
• Latch valves are available upon request
* Available with a manifold bracket upon request.
Please contact our technical sales department

Max. Pressure (bar) 2 Way NC


OUT
Coil Orifice (mm)
Current/Power 0.8 1.2 1.6 2.0 2.4 3.0 4.0
ADC * 60 50 35 20 15 10 5
AC8W, DC/10W 80 80 60 38 30 18 10
AC5.5W 80 60 40 28 20 15 6
AC2.5W 60 50 35 20 15 9 5
DC5.5W 60 30 18 12 9 6 3
DC3.5W 40 20 12 8 6 4 2

Flow factor Kv(l/min) 0.5 1.1 1.7 2.5 3.5 4.5 5

IN
IN OUT

Max. Pressure (bar) 2 Way NO P


(2)
A
(1)
P
(2)

Orifice (mm) 2 Way NC 2 Way NO


Coil
Current/Power 0.8 1.2 1.6 2.0 2.4 3.0
ADC * 25 25 25 20 15 10
Flow factor Kv(l/min) 0.5 1.1 1.4 2.5 3.0 3.5
* ADC valves are only suitable for use with AC8W or DC10W coils

18 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-SOL® | GEM-A | 1/8”, 1/4” 2 Way NC, NO

Dimensions Optional Mounting Bracket

BS P / N P T 1/8 " o r 1/4"


TY P x 2

rass / Stainless Steel

Tackling climate
change together 19
SOLENOID VALVES

GEM-SOL® | GEM-A
1/8”, 1/4” 2 Way NC, NO

Three Product Ordering Categories available


STANDARD | Reduced lead times, No MOQ
SEMI-STANDARD | Normal lead times, No MOQ
SPECIAL | Extended lead times, Non-stock items, MOQ may be applicable

Ordering Chart
Standard items | Reduced lead times, No MOQ
ADC operator only
IDE

PART NO. PER VOLTAGE & POWER


RR
L
RIA
m)

*Standard coils are not vacuum impregnated


R
OV

)
(m
L

ar
TE

TO
DE

(b
MA
TIO

AL

EC
CE
MO

NU

PD
NN
NC
RT

IFI

AL

24VDC 10W 24VAC 8W 50Hz 110VAC 8W 60Hz 230VAC 8W 50Hz


MO
MA
OR
PO

CO
FU

SE

1253820062 1253820063 1253820064 1253820065


1.6 35 GEM-A-21013N2-331 ADC GEM-A-21013N2-311 ADC GEM-A-21013N2-521 ADC GEM-A-21013N2-711 ADC
1/8” 1253820218 1253820203 1253820219 1253820220
2.0 20 GEM-A-21014N2-331 ADC GEM-A-21014N2-311 ADC GEM-A-21014N2-521 ADC GEM-A-21014N2-711 ADC
BSP
1253830041 1253830048 1253830049 1253830050
2.4 15 GEM-A-21015N2-331 ADC GEM-A-21015N2-311 ADC GEM-A-21015N2-521 ADC GEM-A-21015N2-711 ADC

1253820066 1253820067 1253820068 1253820069


1.6 35 GEM-A-21113N2-331 ADC GEM-A-21113N2-311 ADC GEM-A-21113N2-521 ADC GEM-A-21113N2-711 ADC
1/8” 1253820221 1253820222 1253820223 1253820224
2.0 20 GEM-A-21114N2-331 ADC GEM-A-21114N2-311 ADC GEM-A-21114N2-521 ADC GEM-A-21114N2-711 ADC
NPT
1253830051 1253830052 1253830053 1253830054
GEM-A 2.4 15 GEM-A-21115N2-331 ADC GEM-A-21115N2-311 ADC GEM-A-21115N2-521 ADC GEM-A-21115N2-711 ADC
2W
NBR Slot with
NC 1255820108 1255820031 1255820109 1255820110
BRASS 1.6 35 GEM-A-22013N2-331 ADC GEM-A-22013N2-311 ADC GEM-A-22013N2-521 ADC GEM-A-22013N2-711 ADC
1/4” 1255820301 1255820302 1255820303 1255820304
2.0 20 GEM-A-22014N2-331 ADC GEM-A-22014N2-311 ADC GEM-A-22014N2-521 ADC GEM-A-22014N2-711 ADC
BSP
1255830201 1255830202 1255830203 1255830580
2.4 15 GEM-A-22015N2-331 ADC GEM-A-22015N2-311 ADC GEM-A-22015N2-521 ADC GEM-A-22015N2-711 ADC

1255820111 1255820112 1255820113 1255820114


1.6 35 GEM-A-22113N2-331 ADC GEM-A-22113N2-311 ADC GEM-A-22113N2-521 ADC GEM-A-22113N2-711 ADC
1/4” 1255820305 1255820306 1255820307 1255820308
2.0 20 GEM-A-22114N2-331 ADC GEM-A-22114N2-311 ADC GEM-A-22114N2-521 ADC GEM-A-22114N2-711 ADC
NPT

2.4 15 1255830205 1255830206 1255830207 1255830208


GEM-A-22115N2-331 ADC GEM-A-22115N2-311 ADC GEM-A-22115N2-521 ADC GEM-A-22115N2-711 ADC

1255820311 1255820312 1255820313 1255820314


1.6 35 GEM-A-32013V2-331 ADC GEM-A-32013V2-311 ADC GEM-A-32013V2-521 ADC GEM-A-32013V2-711 ADC
1/4” 1255820315 1255820316 1255820317 1255820318
2.0 20 GEM-A-32014V2-331 ADC GEM-A-32014V2-311 ADC GEM-A-32014V2-521 ADC GEM-A-32014V2-711 ADC
BSP
1255830211 1255830531 1255830213 1255830214
GEM-A 2.4 15 GEM-A-32015V2-331 ADC GEM-A-32015V2-311 ADC GEM-A-32015V2-521 ADC GEM-A-32015V2-711 ADC
2W
FKM Slot with
NC 1255820321 1255820322 1255820323 1255820324
SST 1.6 35 GEM-A-32113V2-331 ADC GEM-A-32113V2-311 ADC GEM-A-32113V2-521 ADC GEM-A-32113V2-711 ADC
1/4” 1255820325 1255820326 1255820327 1255820328
2.0 20 GEM-A-32114V2-331 ADC GEM-A-32114V2-311 ADC GEM-A-32114V2-521 ADC GEM-A-32114V2-711 ADC
NPT

2.4 15 1255830215 1255830216 1255830217 1255830218


GEM-A-32115V2-331 ADC GEM-A-32115V2-311 ADC GEM-A-32115V2-521 ADC GEM-A-32115V2-711 ADC

20 A U T O M A T I O N & C O N T R O L
AGRICULTURE

Model Selection
STANDARD | Reduced lead times, No MOQ. Please refer to Standard Items Ordering Chart
SEMI-Standard | Normal lead times, No MOQ
SPECIAL | Extended lead times, Non-stock items, MOQ may be applicable
For a quote, please contact our sales department
MANUAL * For available options, please refer to
GEM-A - BODY PORT FUNCTION ORIFICE SEALS
OVERRIDE
- VOLTAGE & POWER CONSUMPTION table below

Brass 2 1/8" BSP 10 2W NC 1 0.8 1 NBR N None 0


1/8" NPT 11 2W NO 2 1.2 2 FKM V Plastic (3) 1 VOLTAGE POWER CONNECTOR
2WNO (1)
No coil 0 No coil 0 None 0
1/4" BSP 20 through 2a 1.6 3 EPDM E Slot 2
base 6 1 AC8W 50Hz 1 with 1
1/4" NPT 21 2.0 4 FFKM (2) K Knob 3 12 2 AC8W 60Hz 2 with LED 2
2.4 5 PTFE T 24 3 DC10W 3 with bi-color LED 3
3.0 6 48 4 AC5.5W50Hz 4 flying leads coil 4
4.0 7 110 5 AC5.5W60Hz 5 with 1/2" Hub 5
AC2.5W surge protection
120 6 6 6
MANUAL 50/60Hz with LED
GEM-A - BODY PORT FUNCTION ORIFICE SEALS OVERRIDE - connector with
220 7A DC5.5W 7 7
moulded cable
SST 3 1/8" BSP 10 2W NC 1 0.8 1 NBR N None 0 230 7 DC3.5W 8 other 9
1/8" NPT 11 2W NO 2 1.2 2 FKM V Plastic (3)
1 240 8
2WNO (1)
1/4" BSP 20 through 2a 1.6 3 EPDM E Slot 2 Latch/
9
base other (4)
1/4" NPT 21 2.0 4 FFKM (2) K Knob 3
2.4 5 PTFE T
3.0 6
4.0 7

Voltage & Power Consumption


AC (W) Available options:
DC (W) STANDARD
50 Hz 60 Hz
• SEMI-STANDARD
V 8 5.5 2.5 8 5.5 2.5 10 5.5 3.5 SPECIAL
6 • • •
12 • • • • •
24 • • • • • •
48 • • •
110 • • •
120 • •
220 • • • • •
230 • • •
240 • • •

Example: GEM-A-21015N2-311
GEM-SOL® direct operated brass, 1/8"BSP, 2W NC, 2.4 orifice,
NBR, slot manual override, 24V AC8W 50Hz with connector

GEM-A 2 10 1 5 N 2 3 1 1

(1) Option 2a: manual override is not available


(2) FFKM O-ring is available only upon request. When ordering FFKM seals, please consult with our
technical sales department about O-ring compound
(3) Maximum pressure: 16 bar
(4) For specifying Latch type coil, please refer to GEM-A3P valve - How to Order table

* Note: When ordering without coil, please define what current and pressure rating is needed (DC, AC or ADC),
otherwise an ADC valve will be supplied

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 21
SOLENOID VALVES

GEM-SOL® | GEM-A
1/8”, 1/4” 3 Way NC, NO

Technical Data
Function 3 Way NC, NO
Ports size 1/8" and 1/4" BSP & NPT
Orifice size See table
• See table
Pressure range • Valves for pressure higher than 25 bar
cannot be supplied with manual override
Kv (l/min) See table
Fluid: -10ºC to 80ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
Manual override:
Plastic (Reinforced Nylon), Brass screw or Brass GEM-A | 3 Way GEM-A | 3 Way
finger knob, Stainless Steel for Stainless Steel Stainless Steel Brass
valves
(1) Plastic manual override:
Maximum pressure: 16 bar
Materials in contact (2) Manual override is unavailable in 3 Way NO
with media through base applications
Main Valve:
Brass or Stainless Steel AISI 316
Solenoid Operator:
Stainless Steel AISI 300 & 400 series
Seals:
NBR, FKM, EPDM, FFKM, PTFE
Media Air, water, oil
• Voltage and power consumption - see table
Coil voltage
• All Baccara coil voltages are ± 10% of nominal NO IN NC EX
IP65 with connector
Standard protection class
* Option: IP68 (please refer to GEM-BP Coil)
• Latch valves are available upon request
* Available with a manifold bracket upon request.
Please contact our technical sales department

Max. Pressure (bar) 3 Way NC


Coil Orifice (mm)
Current/Power 0.8 1.2 1.6 2.0 2.4 3.0
IN NC
ADC * 23 20 15 10 8 5.5
EX NO OUT
NC/NO
AC8W, DC10W 35 30 17 14 10 6
P(NC) A
AC5.5W 23 20 15 10 8 5.5 (1) (2)
AC2.5W
DC5.5W 20 16 10 9 5 4

Dimensions
DC3.5W
Optional Mounting Bracket Optional Mounting Bracke
Flow factor Kv(l/min) 0.6 1.1 1.7 2.5 3.5 4.5

Max. Pressure (bar) 3 Way NO


Coil Orifice (mm)
Current/Power 0.8 1.2 1.6 2.0 2.4 3.0
ADC * 25 20 15 11 8 6
AC/8W DC/10W 30 22 17 12 10 7
AC/5.5W,DC/5.5W 25 20 15 11 8 6
AC/2.5W,DC/3.5W 20 18 12 8 6 4
Flow factor Kv(l/min) 0.6 1 1.4 2.2 3.0 3.5
* ADC valves are only suitable for use with AC8W or DC10W coils.
BS P / N P T 1/8 " o r 1/4" BS P / N P T 1/8 " o r 1/4"
TY P x 2 TY P x 2

22 A U T O M A T I O N & C O N T R O L
B /S B /S
AGRICULTURE

Three Product Ordering Categories available


STANDARD | Reduced lead times, No MOQ
SEMI-STANDARD | Normal lead times, No MOQ
SPECIAL | Extended lead times, Non-stock items, MOQ may be applicable

Ordering Chart
Standard items | Reduced lead times, No MOQ
ADC operator only

PART NO. PER VOLTAGE & POWER


E
RID
IAL

ER
)

*Standard coils are not vacuum impregnated


mm

ER

R
OV

)
ar
TO
N

AT
E(

(b
TIO

AL

EC
M
L

NU

PD

24VDC 10W 24VAC 8W 50Hz 110VAC 8W 60Hz 230VAC 8W 50Hz


DE

NN
NC
RT

IFI

AL
MO

MO
MA
OR
PO

CO
FU

SE

1253088030 1253088201 1253088202 1253088203


1.6 15 GEM-A-21033N2-331 ADC GEM-A-21033N2-311 ADC GEM-A-21033N2-521 ADC GEM-A-21033N2-711 ADC

1/8” 1253090201 1253090202 1253090203 1253090204


2.0 10 GEM-A-21034N2-331 ADC GEM-A-21034N2-311 ADC GEM-A-21034N2-521 ADC GEM-A-21034N2-711 ADC
BSP
1253093201 1253093202 1253093203 1253093204
2.4 8 GEM-A-21035N2-331 ADC GEM-A-21035N2-311 ADC GEM-A-21035N2-521 ADC GEM-A-21035N2-711 ADC
3W
NC 1253088204 1253088205 1253088206 1253088207
1.6 15 GEM-A-21133N2-331 ADC GEM-A-21133N2-311 ADC GEM-A-21133N2-521 ADC GEM-A-21133N2-711 ADC

1/8” 1253090205 1253090206 1253090632 1253090207


2.0 10 GEM-A-21134N2-331 ADC GEM-A-21134N2-311 ADC GEM-A-21134N2-521 ADC GEM-A-21134N2-711 ADC
NPT
1253093205 1253093206 1253093207 1253093208
2.4 8 GEM-A-21135N2-331 ADC GEM-A-21135N2-311 ADC GEM-A-21135N2-521 ADC GEM-A-21135N2-711 ADC

1253127251 1253127536 1253127252 1253127587


1.6 15 GEM-A-21043N2-331 ADC GEM-A-21043N2-311 ADC GEM-A-21043N2-521 ADC GEM-A-21043N2-711 ADC

1/8” 1253130201 1253130202 1253130203 1253130204


2.0 11 GEM-A-21044N2-331 ADC GEM-A-21044N2-311 ADC GEM-A-21044N2-521 ADC GEM-A-21044N2-711 ADC
BSP
1253138201 1253138202 1253138203 1253138204
2.4 8 GEM-A-21045N2-331 ADC GEM-A-21045N2-311 ADC GEM-A-21045N2-521 ADC GEM-A-21045N2-711 ADC
3W
NO 1253127253 1253127254 1253127556 1253127255
1.6 15 GEM-A-21143N2-331 ADC GEM-A-21143N2-311 ADC GEM-A-21143N2-521 ADC GEM-A-21143N2-711 ADC

1/8” 1253130205 1253130206 1253130207 1253130208


2.0 11 GEM-A-21144N2-331 ADC GEM-A-21144N2-311 ADC GEM-A-21144N2-521 ADC GEM-A-21044N2-711 ADC
NPT
1253138042 1253138205 1253138206 1253138207
GEM-A 2.4 8 GEM-A-21145N2-331 ADC GEM-A-21145N2-311 ADC GEM-A-21145N2-521 ADC GEM-A-21145N2-711 ADC0
NBR Slot with
BRASS 1255088333 1255088202 1255088203 1255088204
1.6 15 GEM-A-22033N2-331 ADC GEM-A-22033N2-311 ADC GEM-A-22033N2-521 ADC GEM-A-22033N2-711 ADC

1/4” 1255091030 1255091202 1255091203 1255091204


2.0 10 GEM-A-22034N2-331 ADC GEM-A-22034N2-311 ADC GEM-A-22034N2-521 ADC GEM-A-22034N2-711 ADC
BSP
1255093030 1255093202 1255093203 1255093204
2.4 8 GEM-A-22035N2-331 ADC GEM-A-22035N2-311 ADC GEM-A-22035N2-521 ADC GEM-A-22035N2-711 ADC
3W
NC 1255088032 1255088352 1255088205 1255088382
1.6 15 GEM-A-22133N2-331 ADC GEM-A-22133N2-311 ADC GEM-A-22133N2-521 ADC GEM-A-22133N2-711 ADC

1/4” 1255091205 1255091206 1255091207 1255091208


2.0 10 GEM-A-22134N2-331 ADC GEM-A-22134N2-311 ADC GEM-A-22134N2-521 ADC GEM-A-22134N2-711 ADC
NPT
1255093205 1255093206 1255093207 1255093208
2.4 8 GEM-A-22135N2-331 ADC GEM-A-22135N2-311 ADC GEM-A-22135N2-521 ADC GEM-A-22135N2-711 ADC

1255127201 1255127530 1255127203 1255127580


1.6 15 GEM-A-22043N2-331 ADC GEM-A-22043N2-311 ADC GEM-A-22043N2-521 ADC GEM-A-22043N2-711 ADC

1/4” 1255130030 1255130530 1255130203 1255130581


2.0 11 GEM-A-22044N2-331 ADC GEM-A-22044N2-311 ADC GEM-A-22044N2-521 ADC GEM-A-22034N2-711 ADC
BSP
1255138201 1255138202 1255138203 1255138204
2.4 8 GEM-A-22045N2-331 ADC GEM-A-22045N2-311 ADC GEM-A-22045N2-521 ADC GEM-A-22045N2-711 ADC
3W
NO 1255127032 1255127534 1255127207 1255127584
1.6 15 GEM-A-22143N2-331 ADC GEM-A-22143N2-311 ADC GEM-A-22143N2-521 ADC GEM-A-22143N2-711 ADC

1/4” 1255130205 1255130533 1255130207 1255130208


2.0 11 GEM-A-22144N2-331 ADC GEM-A-22144N2-311 ADC GEM-A-22144N2-521 ADC GEM-A-22134N2-711 ADC
NPT
1255138205 1255138206 1255138207 1255138208
2.4 8 GEM-A-22145N2-331 ADC GEM-A-22145N2-311 ADC GEM-A-22145N2-521 ADC GEM-A-22145N2-711 ADC
(continued on next page)

Tackling climate
change together 23
SOLENOID VALVES

GEM-SOL® | GEM-A
1/8”, 1/4” 3 Way NC, NO

Ordering Chart
Standard items | Reduced lead times, No MOQ
ADC operator only RID
E
IAL

PART NO. PER VOLTAGE & POWER


ER
)
mm

ER

R
OV

)
ar
TO
N

AT

*Standard coils are not vacuum impregnated


E(

(b
TIO

AL

EC
M
L

NU

PD
DE

NN
NC
RT

IFI

AL
MO

MO
MA
OR
PO

CO
FU

SE

24VDC 10W 24VAC 8W 50Hz 110VAC 8W 60Hz 230VAC 8W 50Hz

1255088211 1255088212 1255088213 1255088214


1.6 15 GEM-A-32033V2-331 ADC GEM-A-32033V2-311 ADC GEM-A-32033V2-521 ADC GEM-A-32033V2-711 ADC

1/4” 1255091211 1255091212 1255091213 1255091214


2.0 10 GEM-A-32034V2-331 ADC GEM-A-32034V2-311 ADC GEM-A-32034V2-521 ADC GEM-A-32034V2-711 ADC
BSP
1255093211 1255093212 1255093213 1255093214
2.4 8 GEM-A-32035V2-331 ADC GEM-A-32035V2-311 ADC GEM-A-32035V2-521 ADC GEM-A-32035V2-711 ADC
3W
NC 1255088215 1255088216 1255088217 1255088218
1.6 15 GEM-A-32133V2-331 ADC GEM-A-32133V2-311 ADC GEM-A-32133V2-521 ADC GEM-A-32033V2-711 ADC

1/4” 1255091215 1255091216 1255091217 1255091218


2.0 10 GEM-A-32034V2-331 ADC GEM-A-32134V2-311 ADC GEM-A-32134V2-521 ADC GEM-A-32134V2-711 ADC
NPT
1255093215 1255093216 1255093217 1255093218
GEM-A 2.4 8 GEM-A-32135V2-331 ADC GEM-A-32135V2-311 ADC GEM-A-32135V2-521 ADC GEM-A-32135V2-711 ADC
FKM Slot with
SST 1255127211 1255127074 1255127213 1255127214
1.6 15 GEM-A-32043V2-331 ADC GEM-A-32043V2-311 ADC GEM-A-32043V2-521 ADC GEM-A-32043V2-711 ADC

1/4” 1255130211 1255130212 1255130213 1255130214


2.0 11 GEM-A-32044V2-331 ADC GEM-A-32044V2-311 ADC GEM-A-32044V2-521 ADC GEM-A-32044V2-711 ADC
BSP
3W 1255138049 1255138212 1255138213 1255138214
2.4 8 GEM-A-32045V2-331 ADC GEM-A-32045V2-311 ADC GEM-A-32045V2-521 ADC GEM-A-32045V2-711 ADC
NO
1255127149 1255127215 1255127216 1255127217
1.6 15 GEM-A-32143V2-331 ADC GEM-A-32143V2-311 ADC GEM-A-32143V2-521 ADC GEM-A-32143V2-711 ADC

1/4” 1255130215 1255130216 1255130217 1255130218


2.0 11 GEM-A-32144V2-331 ADC GEM-A-32144V2-311 ADC GEM-A-32144V2-521 ADC GEM-A-32144V2-711 ADC
NPT
1255138215 1255138216 1255138217 1255138218
2.4 8 GEM-A-32145V2-331 ADC GEM-A-32145V2-311 ADC GEM-A-32145V2-521 ADC GEM-A-32145V2-711 ADC

24 A U T O M A T I O N & C O N T R O L
AGRICULTURE

Model Selection
STANDARD | Reduced lead times, No MOQ. Please refer to Standard Items Ordering Chart
SEMI-STANDARD | Normal lead times, No MOQ
SPECIAL | Extended lead times, Non-stock items, MOQ may be applicable.
For a quote, please contact our sales department
* For available options, please refer to
VOLTAGE & POWER CONSUMPTION table below

MANUAL
GEM-A - BODY PORT FUNCTION ORIFICE SEALS
OVERRIDE
- VOLTAGE POWER CONNECTOR

Brass 2 1/8" BSP 10 3W NC 3 0.8 1 NBR N None 0 No coil 0 No coil 0 None 0


1/8" NPT 11 3W NO 4 1.2 2 FKM V Plastic (3)
1 6 1 AC8W 50Hz 1 with 1
3WNO (1) 12 2 AC8W 60Hz 2 with LED 2
1/4" BSP 20 through 4a 1.6 3 EPDM E Slot 2
24 3 DC10W 3 with bi-color LED 3
base
1/4" NPT 21 2.0 4 FFKM (2)
K Knob 3 48 4 AC5.5W50Hz 4 flying leads coil 4

2.4 5 PTFE T 110 5 AC5.5W60Hz 5 with 1/2" Hub 5


AC2.5W surge protection
3.0 6 120 6 6 6
50/60Hz with LED
connector with
220 7A DC5.5W 7 7
MANUAL moulded cable
GEM-A - BODY PORT FUNCTION ORIFICE SEALS OVERRIDE - 230 7 DC3.5W 8 other 9
SST 3 1/8" BSP 10 3W NC 3 0.8 1 NBR N None 0 240 8
1/8" NPT 11 3W NO 4 1.2 2 FKM V Plastic (3)
1 Latch/
9
other(4)
3WNO (1)
1/4" BSP 20 through 4a 1.6 3 EPDM E Slot 2
base
1/4" NPT 21 2.0 4 FFKM (2) K Knob 3
2.4 5 PTFE T
3.0 6

Voltage & Power Consumption


AC (W) Available options:
DC (W) STANDARD
50 Hz 60 Hz
• SEMI-STANDARD
V 8 5.5 2.5 8 5.5 2.5 10 5.5 3.5 SPECIAL
6 • • •
12 • • • • •
24 • • • • • •
48 • • •
110 • • •
120 • •
220 • • • • •
230 • • •
240 • • •

Example: GEM-A-21035N2-311
® direct operated brass, 1/8"BSP, 3W NC, 2.4 orifice,

NBR, slot manual override, 24V AC8W 50Hz with connector

GEM-A 2 10 3 5 N 2 3 1 1

(1) Option 4a: manual override is not available


(2) FFKM O-ring is available only upon request. When ordering FFKM seals, please consult with our
technical sales department about O-ring compound
(3) Maximum pressure: 16 bar
(4) For specifying Latch type coil, please refer to GEM-A3P valve - How to Order table

* Note: When ordering without coil, please define what current and pressure rating is needed (DC, AC or ADC),
otherwise an ADC valve will be supplied

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 25
SOLENOID VALVES

GEM-SOL® | GEM-A3P
1/8”, 1/4” Latch 3 Positioning Manual Override,
2 Way, 3 Way NC, NO
Technical Data
Function 2 Way, 3 Way NC, NO
Ports size 1/8" and 1/4" BSP & NPT
Orifice size See table
Pressure range See table
Kv (l/min) See table
Fluid: -10ºC to 80ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
Manual override:
Plastic (Reinforced Nylon)
Main Valve:
Materials in contact Brass
with media Solenoid Operator:
Stainless Steel AISI 300 & 400 series
Seals:
NBR, FKM, EPDM, FFKM
Media Air, water, oil
Coil type Latch
IP65 with connector
Standard protection class
* Option: IP68 (please refer to GEM-BP Coil)
* Available with a manifold bracket upon request.
Please contact our technical sales department

Max. Pressure (bar) 2 Way NC


NO NC
Orifice (mm) 0.8 1.2 1.6 2.0 2.4 3.0 4.0 IN EX

Pressure (bar) 16 16 16 16 16 16 8
Flow factor Kv(l/min) 0.5 1.1 1.7 2.5 3.5 4.5 5

Max. Pressure (bar) 2 Way NO


Orifice (mm) 0.8 1.2 1.6 2.0 2.4 3.0
Pressure (bar) 16 16 16 16 15 10
Flow factor Kv(l/min) 0.5 1.1 1.7 2.5 3.5 4.5

OUT IN NC
IN OUT NC/NO
Max. Pressure (bar) 3 Way NC EX NO
(2) (1) (2) (1)
Orifice (mm) 0.8 1.2 1.6 2.0 2.4 3.0
2 Way 3 Way
Pressure (bar) 16 16 16 14 9 5
Flow factor Kv(l/min) 0.5 1.1 1.7 2.5 3.5 4.5

Max. Pressure (bar) 3 Way NO


Orifice (mm) 0.8 1.2 1.6 2.0 2.4 3.0
Pressure (bar) 16 16 16 12 10 7
Flow factor Kv(l/min) 0.5 1.1 1.7 2.5 3.5 4.5

26 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-SOL® | GEM-A3P | 1/8”, 1/4” Latch 3 Positioning Manual


Override, 2 Way, 3 Way NC, NO

Dimensions Note:
C - Closed
O - Open
A - Automatic
To change from "O" to "A", the
manual override must be turned
2 2

2 2
from "O" to "C" and then to "A":
"O""C""A"

M 5 DEEP 7 M 5 DEEP 7
TY P x 2 TY P x 2
2 2 2 2

7 1. 2
7 1. 2
1/8 ” BS P /N P T
7 5 .6

7 5 .6
2 7 .5

2 7 .5

1/8 ” O R 1/4” BS P /N P T 1/8 ” O R 1/4” BS P /N P T


TY P x 2 TY P x 2
2 Way 3 Way
15 15
33 33
40 40

How to Order
GEM-A3P - BODY PORT FUNCTION ORIFICE SEALS - LATCH TYPE (1) CONNECTOR

Brass 2 1/8" BSP 10 2W NC 1 0.8 1 NBR N 2Ω LDO without 0

1/8" NPT 11 2W NO 2 1.2 2 FKM V 5Ω IL with 1

with 1/2”
1/4" BSP 20 3W NC 3 1.6 3 EPDM E 13Ω EL 5
Hub
connector
1/4" NPT 21 3W NO 4 2.0 4 FFKM K 20Ω OL with moulded 7
cable
2.4 5 53Ω DL other 9
3.0 6

4.0 7

Example: GEM-A3P-21015N-LDO1
GEM-SOL® latch 3 positioning manual override, brass, 1/8"BSP, 2W NC, 2.4 orifice,
NBR, 2Ω latch with connector

GEM-A3P 2 10 1 5 N LDO 1

(1) Choose latch type according to which latch system you have

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 27
A U T O M A T I O N & C O N T R O L
SOLENOID MANIFOLDS

GEM-FLOW™ | G75-VM Modular Manifold .................................................................................................................. 30

Tackling climate
change together
SOLENOID MANIFOLDS

GEM-FLOW™ | G75-VM
Modular Manifold

Technical Data
Function 3 Way NC, NO
Orifice size 1.8 mm
Pressure range 0 to 8 bar
Fluid: 0ºC to 50ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
Manual override:
Plastic (Reinforced Nylon)
Main Valve:
Materials in contact Plastic (Reinforced Nylon & POM)
with media Solenoid Operator:
Stainless Steel AISI 300 & 400 series
Seals:
EPDM
Mounting With bracket
Modular connection type Thread type connection
• Manually tighten one station to another
Modular connection assembly
• Using tools and/or excessive torques may
recommendation
lead to irreversible damage
Latch: 3 position latch: Auto, Close, Open
Manual override
AC: 2 position: Auto, Open
Media Air, water
Coil voltage Latch, AC (according to table)
Standard protection class IP66
* Can only be operated with supplied coil

PORT NO NC
1 Exhaust Pressure
3 Pressure Exhaust
COM Out Out
COM 1

Voltage & Current (1)


AC & DC
Solenoid Inrush [A] Holding [A] (3)
24VAC-50 Hz 0.33 0.21

Latch Coil Resistance vs Input Voltage


COM 2

Recommendations chart
Resistance [Ω] Input voltage range [V]
4 6-9
9 12 - 14
12 14 - 16
23 18 - 21

30 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G75-VM | Modular Manifold Mounting Bracket

Manual Override Operation

42

TYP
2
42
NO NC

9
4
Px
TY
15 TYPx2

Dimensions OPEN OPEN

56.2

58

85
110
CLOSE CLOSE 9 TYPx4

• For 2, 4 or 6 stations

14
2
Px
TY
• For 8-10 stations, 2 brackets
AUTO
are supplied
AUTO

42

TYP
2
42
9 TYPx4

56.2
1/8" BSPT \ NPT

1/8" BSPT \ NPT

160

58

85
56.2
119

119

15 TYPx3

14
1/8" BSPT \ NPT1/8" BSPT \ NPT

3
Px
1/8" BSPT \ NPT1/8" BSPT \ NPT

TY
• For 3, 5 or 7 stations
1/8" BSPT \ NPT1/8" BSPT \ NPT
44 44
13

13

56 56 1/4" BSPT 1/4" BSPT


57 57

56 X Number of
56stations
X Number of stations

How to Order | Manifold


No. OF MANUAL MOUNTING
G75-VM - STATIONS (1) BODY PORT FUNCTION
OVERRIDE
ORIFICE SEALS - TYPE
BRACKET
OUTLET (4) WIRES

Plastic 4 1/8" BSPT 10 3W NC 3 Plastic 1 1.8 3a EPDM E 24VAC-50Hz (2) S1 with 1 COM 1 1 two Null
Specify
quantity: 1/8" NPT 11 3W NO 4 4Ω (3) SB COM 2 2 three (5) a
2 - 10
9Ω (3) SC

Example: G75-VM-3410313aE-SB11 12Ω (3) SD


G75-VM manifold, 3 stations, plastic, 1/8" BSPT, 3W NC, plastic manual override, 23Ω (3) S6
1.8 orifice, EPDM seals, 4Ω latch, with mounting bracket, COM 1 outlet, two wires

G75-VM 3 4 10 3 1 3a E SB 1 1

(1) Manifold designed for a maximum of 10 stations, the use of more will reduce the outlet flow rate to all
(2) Refer to Voltage & Current AC & DC
(3) Refer to Latch Coil Resistance vs Input Voltage | Recommendations chart
(4) A plug will be fitted on the other outlet port
(5) Latch only

How to Order | Manifold Components


MANUAL
G75-VM - TYPE BODY PORT FUNCTION
OVERRIDE
ORIFICE SEALS - TYPE OUTLET (3) WIRES

Left L Plastic 4 1/8" BSPT 10 3W NC 3 Plastic 1 1.8 3a EPDM E 24VAC-50Hz (1)


S1 COM 1 1 two Null
Right R 1/8" NPT 11 3W NO 4 4Ω (2) SB COM 2 2 three (4)
a
Middle M 9Ω (2) SC
Example: G75-VM-L410313aE-SB1 12Ω (2) SD
G75-VM Left component, plastic, 1/8" BSPT, 3W NC, plastic manual override
23Ω (2) S6
1.8 orifice, EPDM seals, 4Ω latch, COM 1 outlet, two wires

G75-VM L 4 10 3 1 3a E SB 1
(1) Refer to Voltage & Current AC & DC
(2) Refer to Latch Coil Resistance vs Input Voltage | Recommendations chart
(3) A plug will be fitted on the other outlet port
(4) Latch only

* To order manifolds manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 31
A U T O M A T I O N & C O N T R O L
ISOLATED / FERTILIZER
SOLENOIDS
GEM-SOL® | GEM-CPR Precise Isolated Proportional 2 Way NC .................................................................... 34
GEM-SOL® | GEM-C Chem-Sol 1/4” 2 Way NC, NO............................................................................................ 36
GEM-SOL® | GEM-C Chem-Sol 1/2” 2 Way NC.................................................................................................... 38

Tackling climate
change together
ISOLATED/FERTILIZER SOLENOIDS

GEM-SOL® | GEM-CPR
Precise Isolated Proportional 2 Way NC

Technical Data
Function 2 Way NC (with back-up battery)
Ports size 1/2" BSP & NPT
Orifice size 8mm (Up to 600 l/hour)
• Vacuum applications: (-1) - 0 Bar
• Pressure applications: 0 - (+1) Bar
Pressure range
*For other pressures, please consult our technical
sales department
Fluid: -10º to 45ºC (no freezing)
Temperature range
Ambient: -10ºC to 45ºC
In contact with media:
Valve body:
• Standard: PVC (UV Protection)
• Optional: According to customer demand or
Materials application (e.g Stainless steel)
Diaphragm & seals: FKM, EPDM
Not in contact with media:
Operator housing: PP (UV protection)
Manual override: Acetal (Manual override is standard)
• Liquids & Gases
*Please consult our technical sales department for a
specific media
Media
• Application examples:
• Irrigation fertilizing systems
• Medical devices
Control signal 0-5V or 4-20mA
Valve stroke resolution < 0.01mm
Valve stroke accuracy < ± 0.01 mm
Full stroke duration 0.6 sec, each direction
• Standby Mode (Holding position): 25 [mA]
Current consumption • Active Control Mode: Up to 120 [mA]
• Full Open/Close Mode (starting current): Up to 600 [mA]
12-24 [V] ±5% AC (50 or 60Hz) Or 12-24[V] ±10% DC
*For other supply voltages, please consult our
technical sales department
Supply voltage
*Current and voltage spikes protections might be
required. Please consult our technical sales
department
5 wires cable (3m length):
• Black & red: Supply voltage (polarity is not restricted)
Connection • Green: 0-5 V analog control signal
• Blue: 4-20 mA analog control signal
• Yellow: Analog control signal common
Recommended control
Voltage: 20 mV | Current: 0.064 mA
signal resolution
CE
• EMC: EN55011 Group 1 - Class A | EN61000-6-1
Standard / Certification CFR 47 FCC Class A
• SAFETY: IEC/EN61010-1
Standard protection class IP67

Typical Performance Graph


Input Signal Vs Flow
00
Media: Water
00
p: 0.9 [bar]
Temp: 200C
00

400

00

00

00

0
Flow direction
460
480
500
540
580
620
660
700
740
780
820
860
900
940
980
1020
1060
1100
1160
1220
1280
1340
1400
1460
1520
1580
1640
1700
1760
1820
1880
1940
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000

34 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-SOL® | GEM-CPR | Precise Isolated Proportional 2 Way NC

Dimensions 32

32
22
M4 10
TYPX2 22
(Optional inserts)

92.6
52
85.5
6.8

TYPX2

13.6
14
60

62
1/2" BSP 15
or
1/2" NPT Guage
TYPX2

How to Order
MANUAL CONTROL
GEM-CPR - PORT FUNCTION PRESSURE SEALS
OVERRIDE - SIGNAL
VOLTAGE

1/2" BSP 40 2W NC 1 Vacuum 1 FKM V Plastic 1 0-5 V 1 12-24 VDC 1


1/2" NPT 41 Pressure (1)
2 EPDM E 4-20 mA 2 12-24 VAC 2

Example: GEM-CPR-4011E1-11
Precise Isolated proportional valve, 1/2" BSP, 2W NC, Vacuum, EPDM seals,
plastic manual override with 0-5V control signal, 12-24VDC

GEM-CPR 40 1 1 E 1 1 1

(1) Maximum inlet pressure: 1 bar

* Please specify the working pressure range when placing an order

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 35
ISOLATED/FERTILIZER SOLENOIDS

GEM-SOL® | GEM-C
Chem-Sol 1/4” 2 Way NC, NO

Technical Data
Function 2 Way NC, NO
Ports size 1/4" BSP & NPT
4.5mm
Orifice size * Option for 2.8 mm orifice. Please contact
our technical sales department
Pressure range See table
Kv (l/min) 5 l/min
Fluid: 5º to 50ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
Manual override:
NC: Plastic (Reinforced Nylon)
NO: Manual override is not available
Materials in contact
Main Valve:
with media
Reinforced PPA
Seals:
FKM, EPDM, Silicone
• Chemical process
Applications • Water treatment
• Analysis device etc
• Voltage and power consumption - see table
Coil voltage
• All Baccara coil voltages are ± 10% of nominal
IP65 with connector
Standard protection class
* Option: IP68 (please refer to GEM-BP coil)

NO
NC

Pressure (bar) NC
Flow direction not Flow direction
Coil
restricted restricted
ADC * 0 to 2.5 bar 0 to 0.6 bar
AC 8W 0 to 2.5 bar 0 to 0.7 bar
AC 5.5W 0 to 2 bar 0 to 0.5 bar
DC 5.5W 0 to 1.5 bar 0 to 0.4 bar

Vacuum (bar) NC
Flow direction not
Coil minimum p
restricted
ADC * -1 to 0 bar Flow direction
Pressure
AC 5.5W -1 to 0 bar 1 bar
Flow direction
DC 5.5W -1 to 0 bar Vacuum

Pressure (bar) NO Voltage & Power Consumption


Flow direction not Flow direction AC (W)
Coil & power rating DC (W)
restricted restricted (1) 50 Hz 60 Hz
ADC*, AC 8W or DC10W 0 to 1 bar 0 to 0.5 bar V 8 5.5 2.5 8 5.5 2.5 10 5.5 3.5
5.5W AC/DC 0 to 1 bar 0 to 0.5 bar 6 • •
12 • • • •
(1) Higher input pressure of up to 1atm can be achieved with minimal 24 • • • • •
pressure drop on the valve of 0.3atm 48 • • •
* ADC valves are only suitable for use with AC8W or DC10W coils. 110 • • • •
120 • •
220 • • • •
230 • • • •
240 • • •
• Available options

36 A U T O M A T I O N & C O N T R O L

• Available options
AGRICULTURE

GEM-SOL® | GEM-C | Chem-Sol 1/4” 2 Way NC, NO

F o r ta p p in g s c r e w
N o . 4 x 1/2 ”

Dimensions Notes
Type Valve Description H
NC GEM-C-12 1.... 81
2 2
NO GEM-C-12 2.... 84.5

2 2
H

1/4 BS P / N P T
0

40 19

6 6 30

How to Order
MANUAL
GEM-C - BODY PORT FUNCTION PRESSURE SEALS
OVERRIDE (1) - VOLTAGE POWER CONNECTOR

W/out
Plastic 1 1/4" BSP 20 2W NC 1 Vacuum 1 FKM V None 0 0 No coil 0 without 0
coil
AC8W
1/4" NPT 21 2W NO 2 Pressure 2 EPDM E Plastic 1 6 1 1 with 1
50Hz
AC8W
Silicone S 12 2 2 with LED 2
60Hz
with bi- color
24 3 DC10W 3 3
LED
AC5.5W
48 4 4 flying leads coil 4
50Hz
AC5.5W
110 5 5 with 1/2" Hub 5
60Hz
surge protection
120 6 DC5.5W 7 6
with LED
connector with
220 7A 7
moulded cable

230 7 other 9

240 8

Latch/ 9
other (2)
Example: GEM-C-12012V1-321
GEM-SOL® Chem-Sol, PPA, 1/4"BSP, 2W NC, Pressure, FKM,
plastic manual override, 24V AC 8W 60 Hz with connector

GEM-C 1 20 1 2 V 1 3 2 1

(1) NO - manual override is not available


(2) For specifying Latch type coil, please refer to GEM-A3P valve - How to Order table

* Note: When ordering without coil, please define what current and pressure rating is needed (DC, AC or ADC),
otherwise an ADC valve will be supplied

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 37
ISOLATED/FERTILIZER SOLENOIDS

GEM-SOL® | GEM-C
Chem-Sol 1/2” 2 Way NC

Technical Data
Function 2 Way NC
Ports size 1/2" BSP & NPT
Orifice size 8mm
Pressure range See table
Kv (l/min) 18 l/min
Fluid: 5ºC to 50ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
Manual override:
Plastic (Reinforced Nylon)
* Available for vacuum application only
Materials in contact
Main Valve:
with media
PVC
Seals:
FKM, EPDM
• Chemical process
Applications • Water treatment
• Analysis device etc
• Voltage and power consumption - see table
Coil voltage • All Baccara coil voltages are from
-5% to ±10% of nominal
IP65 with connector
Standard protection class
* Option: IP68 (please refer to GEM-BP coil)
• Supplied with mounting threads on request, please specify

Pressure (bar) NC
Flow direction not Flow direction
Coil
restricted restricted
AC 8W, DC10W 0 to 0.7 bar Min dp 0.3 bar

Vacuum (bar) NC
Flow direction not Flow direction
Coil
restricted restricted
AC 8W -1 to 0.5 bar -1 to 0.5 bar
AC 5.5W -0.5 to 0.5 bar -0.8 to 0.5 bar
DC 10W -0.4 to 0.5 bar -0.6 to 0.5 bar
vacuum

Voltage & Power Consumption Flow direction


AC (W) Flow direction
DC (W)
50 Hz 60 Hz
V 8 5.5 2.5 8 5.5 2.5 10 5.5 3.5
6 • •
12 • • • • • •
24 • • • • • • • •
48 • • • • • •
110 • • • • • • •
120 • • • •
220 • • • • • • • • Available options:
230 • • • • • • • • Vacuum
240 • • • • • • • Pressure

38 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-SOL® | GEM-C | Chem-Sol 1/2” 2 Way NC

standard: without thread


optional : M4x0.7 Deep 10

Dimensions
22 inserts TYPx2
2 2

standard: without thread


optional : M4x0.7 Deep 10 inserts

22
TYPx2
2 2

98.05
8 7

14 TYPx2

1/2" BSP / NPT Deep 15 32 1/2" BSP / NPT TYPx2


both sides 6 2
32 With Manual Override
62

How to Order
* When ordering without coil, please define what
current and pressure rating is needed (DC, AC)

GEM-C - PORT FUNCTION PRESSURE SEALS MANUAL OVERRIDE - VOLTAGE POWER CONNECTOR

W/out
1/2" BSP 40 2W NC 1 Vacuum 1 FKM V None Null 0 No coil 0 without 0
coil
AC8W
1/2" NPT 41 Pressure 2 EPDM E Plastic (1)
1 6 1 50Hz 1 with 1

AC8W
12 2 2 with LED 2
60Hz

3 with bi- color


24 3 DC10W 3
LED
AC5.5W
48 4 4 flying leads coil 4
50Hz
AC5.5W
110 5 5 with 1/2" Hub 5
60Hz
surge protec-
120 6 6
tion with LED
connector with
220 7A 7
moulded cable

230 7 other 9

240 8

Latch/ 9
other (2)
Example: GEM-C-4011V1-321
GEM-SOL® Chem-Sol, 1/2"BSP, 2W NC for vacuum, FKM,
plastic manual override, 24V AC 8W 60Hz with connector

GEM-C 40 1 1 V 1 3 2 1

(1) Available for Vacuum application only


(2) For specifying Latch type coil, please refer to GEM-A3P valve - How to Order table

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 39
A U T O M A T I O N & C O N T R O L
ELECTRIC & HYDRAULIC
VALVES
GEM-SOL® | GEM-S 1/4” - 1” 2 Way NC, NO .......................................................................................................... 42
GEM-SOL® | GEM-S 1/4” - 1” 2 Way NC, NO .......................................................................................................... 44
GEM-SOL® | GEM-S 1/4”, 1/2” 3 Way NC, NO......................................................................................................... 46
GEM-SOL® | GEM-S Pilot Operated 3/4” - 2” 2 Way NC, NO ......................................................................... 48
GEM-SOL | GEM-S-4
®
Upstream Pilot Control Integrated with GEM-SOL® Operator
3/4” - 2” 2 Way NC, NO ........................................................................................................ 50
GEM-FLOW™ | G75-S Pilot Operated 1/2” 2 Way NC .......................................................................................... 52
GEM-FLOW™ | G75-S Electric 3/4” - 2” 2 Way NC ............................................................................................... 54
GEM-SOL® | GEM-Z Zero Differential Pressure 1/4” - 3/4” 2 Way NC, NO ............................................... 56
GEM-FLOW™ | G75-S Hydraulic 3/4”- 2” 2 Way..................................................................................................... 58
GEM-FLOW™ | G75-S 3 Way Integral Solenoid Pilot Control 3/4” - 2” NC ................................................ 60
GEM-FLOW™ | G75-SE 3 Way External Solenoid Pilot Control 3/4” - 2” NC, NO....................................... 61
GEM-FLOW™ | G75 3 Way Manual Selector 3/4” - 2” NC, NO .................................................................... 62
GEM-FLOW™ | G75 Pressure Reducing 3/4” - 2” 2 Way NC ........................................................................ 63

Tackling climate
change together
GEM-SOL® | GEM-S

ELECTRIC & HYDRAULIC VALVES

GEM-SOL® | GEM-S
1/4” - 1” 2 Way NC, NO

Brass | 1/4" | NC Brass | 1/2" | NO Stainless Steel | 3/4" | NC Stainless Steel | 1" | NC

Technical Data Voltage & Power Consumption


Function 2 Way NC, NO AC (W)
DC (W)
Ports size 1/4", 3/8", 1/2", 3/4", 1" BSP & NPT 50 Hz 60 Hz
See table V 8 5.5 2.5 8 5.5 2.5 10 5.5 3.5
Pressure range * Minimum pressure differential of 6 •
0.3 or 0.5 is required 12 • • •
Kv (l/min) See table 24 • • •
Fluid: -10ºC to 80ºC (no freezing) 48 • • •
Temperature range 110 • • •
Ambient: -10ºC to 50ºC
Manual override:
120 • •
NC/NO - Brass screw 220 • • •
NOa* - manual override is not available 230 • • •
*pressure is supplied through the base 240 • • •
Materials in contact Main Valve: • Available options
with media Brass, Stainless Steel AISI 316
Solenoid Operator:
Stainless Steel AISI 300 & 400 series
Seals:
NBR, FKM, EPDM
• Voltage and power consumption - see table
Coil voltage
• All Baccara coil voltages are ± 10% of nominal
IP65 with connector
Standard protection class
* Option: IP68 (please refer to GEM-BP Coil)
• Slow closing system to prevent water hammer effect

42 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-SOL® | GEM-S | 1/4” - 1” 2 Way NC, NO

NO without tube
NC NO (NOa)
Flow direction Flow direction

Pressure (bar) & Flow NO/NC


GEM-S-□-20....41
Orifice Pressure (bar) Kv
Size
(mm) AC, DC ADC (l/min)
1/4" 8 12
3/8" 8 0.5 to 20 0.5 to 15 16
1/2" 12 35

Pressure (bar) & Flow NO/NC


GEM-S-□-□r
Orifice Pressure (bar) Kv
Size
(mm) AC, DC ADC (l/min)
1/2" 16 60
0.5 to 20 0.5 to 15
3/4" 16 80

Pressure (bar) & Flow NO/NC


GEM-S-□-50....60
Port Orifice Pressure range (bar) Kv
Connection (mm) AC, DC & ADC (l/min)
3/4" 20 0.3 to 15 130
1" 25 0.5 to 15 200

Tackling climate
change together 43
ELECTRIC & HYDRAULIC VALVES

GEM-SOL® | GEM-S
1/4” - 1” 2 Way NC, NO

Dimensions
Weight
Size A B C D E F G H J K
with coil
1/4"-3/8"
1/4"-3/8" 58 89 22 32 62 125 11 M5x0.8 22 466gr
BSP/NPT
1/2"
1/2" 70 95 27 38 70 135 13.5 M5x0.8 22 562gr
BSP/NPT
B

N C /N O a N O

2 2 M 5 DEEP 8
Size A B C D E H L I J
TY P x 2
3/4" BSP/NPT 90 106 32 55 32 17 15 25 103
1" BSP/NPT 100 112.5 38.5 65 34 21 16 29.5 109.50
2 2

M a n u a l
10 8 . 1

erride

1/2 ” o r 3/4” BS P /N P T
B

18

7 0 35
44
6 7 .6

G - r 1 mm ori ce
N C /N O a
N C /N O a N O

2 2 M 5 DEEP 8
TY P x 2
2 2

M a n u a l
10 8 . 1

erride

1/2 ” o r 3/4” BS P /N P T
18

7 0 35
44
6 7 .6

G - r 1 mm ori ce
N C /N O a

44 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-SOL® | GEM-S | 1/4” - 1” 2 Way NC, NO

How to Order
MANUAL
GEM-S - BODY PORT FUNCTION SEALS
OVERRIDE - VOLTAGE POWER CONNECTOR

W/out
Brass 2 1/4" BSP 20 2W NC 1 NBR N None 0 0 No coil 0 without 0
coil
Stainless AC8W
3 1/4" NPT 21 2W NO(1) 2 FKM V Slot 2 6 1 1 with 1
Steel 50Hz
30 2W NO (2)
2a EPDM E 3 2 AC8W 2 2
3/8" BSP w/out tube
(3)
Knob 12 60Hz with LED
with bi- color
3/8" NPT 31 24 3 DC10W 3 3
LED
1/2" BSP 40 48 4 flying leads coil 4
1/2" NPT 41 110 5 with 1/2" Hub 5
surge protec-
3/4" BSP 50 120 6 6
tion with LED
connector with 7
3/4" NPT 51 220 7A moulded cable
1" BSP 60 230 7 other 9

1" NPT 61 240 8


Latch/
Example: GEM-S-2202V2-321 9
other (4)
GEM-SOL® pilot operated, brass, 1/4"BSP, 2W NO, FKM seals,
slot manual override, 24V AC8W 60Hz with connector

GEM-S 2 20 2 V 2 3 2 1

(1) Option available in 1/4" - 1/2"


(2) Without manual override
(3) Not available for 3/4” and 1”
(4) For specifying Latch type coil, please refer to GEM-A3P valve - How to order table
* Note: When ordering without coil, please define what current and pressure rating is needed (DC, AC or ADC),
otherwise an ADC valve will be supplied

How to Order
MANUAL
GEM-S - BODY PORT FUNCTION SEALS
OVERRIDE - VOLTAGE POWER CONNECTOR

W/out
Brass 2 1/2" BSP 40r 2W NC 1 NBR N None 0 0 No coil 0 without 0
coil
AC8W
1/2" NPT 41r 2W NO 2 FKM V Slot 2 6 1 1 with 1
50Hz
50r 2W NO (1) 2a EPDM E 3 2 AC8W 2 2
3/4" BSP w/out tube Knob 12 60Hz with LED
with bi- color
3/4" NPT 51r 24 3 DC10W 3 3
LED
flying leads
48 4 4
coil
110 5 with 1/2" Hub 5
surge protec-
120 6 6
tion with LED
connector
Example: GEM-S-240r1V2-321 (16mm orifice size) 220 7A with moulded 7
GEM-SOL® pilot operated, brass, 1/2"BSP, 2W NC, FKM seals, cable
slot manual override, 24V AC8W 60Hz with connector 230 7 other 9

240 8
GEM-S 2 40r 1 V 2 3 2 1
Latch/
other (2) 9
(1) Without manual override.
(2) For specifying Latch type coil, please refer to GEM-A3P valve - How to Order table

* Note: When ordering without coil, please define what current and pressure rating is needed (DC, AC or ADC),
otherwise an ADC valve will be supplied

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 45
ELECTRIC & HYDRAULIC VALVES

GEM-SOL® | GEM-S
1/4”, 1/2” 3 Way NC, NO

Technical Data
Function 3 Way NC, NO
Ports size 1/4", 1/2" BSP & NPT
Pressure range See table
Kv (l/min) See table
Fluid: -10ºC to 80ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
Manual override:
NC: Push in lock hydraulic bypass
NO: Brass screw or finger knob
Main Valve:
Materials in contact
Brass
with media
Solenoid Operator:
Stainless Steel AISI 300 & 400 series
Seals:
NBR, FKM, EPDM
Media Air, water, light oil
• Voltage and power consumption - see table
Coil voltage
• All Baccara coil voltages are ± 10% of nominal
IP65 with connector
Standard protection class
* Option: IP68 (please refer to GEM-BP Coil)

Pressure (bar) & Flow


Orifice Pressure
Size Kv(l/min)
(mm) (bar)
1/4" 8 18
0.8 to 12
1/2" 12 50

Voltage & Power Consumption


In Out In Out
AC (W)
DC (W)
50 Hz 60 Hz
V 8 5.5 2.5 8 5.5 2.5 10 5.5 3.5
6 •
12 • • •
24 • • • EX EX
48 • • •
NO NC
110 • • •
120 • •
220 • • •
230 • •
240 • • •
• Available options

46 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-SOL® | GEM-S | 1/4”, 1/2” 3 Way NC, NO

Dimensions Size A B C D E F G
Weight
with coil
M4x0.7
1/4" 124.5 58 25 32.5 1/4" 32 540gr.
Deep 6
M5x0.8
1/2" 134 69 30 32.5 1/2" 38 758gr.
Deep 7

Optional Mounting Bracket


Size H I J K L M N O P Q

1/4" 15 25 Ø4.5 11 5 14 4 20 25 32

1/2" 20 30 Ø6 13 6 22 4 25 33 40
J
J

How to Order
MANUAL
GEM-S - BODY PORT FUNCTION SEALS
OVERRIDE
BRACKET - VOLTAGE POWER CONNECTOR

W/out
Brass 2 1/4" BSP 20 3W NC 3 NBR N None 0 without 0 0 No coil 0 without 0
coil

21 4 V Slot (1) AC8W


1/4" NPT 3W NO FKM 2 with 1 6 1 1 with 1
50Hz
AC8W
1/2” BSP 40 EPDM E Push lock (2) 5 12 2 60Hz 2 with LED 2

with bi- color


1/2” NPT 41 24 3 DC10W 3 3
LED
flying leads
48 4 4
coil
110 5 with 1/2" Hub 5
surge protec-
120 6 6
tion with LED
connector
220 7A with moulded 7
cable

230 7 other 9

240 8
Example: GEM-S-2204V21-311
GEM-SOL® pilot operated, brass, 1/4"BSP, NO, FKM, Latch/
other (3) 9
slot manual override with bracket, 24V AC 8W 50Hz with connector

GEM-S 2 20 4 V 2 1 3 1 1

(1) For NO only


(2) For NC only
(3) For specifying Latch type coil, please refer to GEM-A3P valve - How to Order table

* Note: When ordering without coil, please define what current and pressure rating is needed (DC, AC or ADC),
otherwise an ADC valve will be supplied

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 47
ELECTRIC & HYDRAULIC VALVES

GEM-SOL® | GEM-S
Pilot Operated 3/4” - 2” 2 Way NC, NO

Technical Data
Function 2 Way NC, NO
Ports size 3/4", 1", 1-1/2", 2" BSPT & NPT
Connection Female BSPT or NPT thread
Pressure range 0.3 to 10 bar
Fluid: 5ºC to 50ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
GEM-SOL® 3/4" UNEF, 2 Way
Solenoid
NC or NO solenoids. All voltages
Manual override:
Plastic (Reinforced Nylon)
Body & cover:
Plastic (Reinforced Nylon)
Spring:
Stainless Steel AISI 302
Materials in contact Diaphragm:
with media NR
Seals:
NBR
Screws:
Stainless Steel AISI 304
Solenoid:
Stainless Steel AISI 300 & 400 series
• Voltage and power consumption - see table
Coil voltage
• All Baccara coil voltages are ± 10% of nominal
IP65 with connector
Standard protection class
* Option: IP68 (please refer to GEM-BP Coil)
• Progressive opening and shut off that prevents water hammer

Head Loss for Fully Open Valve

H
(kg/cm2)
"
3/4

H
(kg/cm2)
1"
"
3/4

RECOMMENDED WORKING ZONE


1"

RECOMMENDED WORKING ZONE

Q (m3/h)
Flow direction
Q (m3/h)

Head Loss for Fully Open Valve Flow Factor & Orifice
Orifice Kv
Size
(mm) (l/min)
/2 " - 1/2 "

2 "

3/4" 27 140
1

H
(kg/cm2) 1" 27 200
1- 1

2 "

H RECOMMENDED
(kg/cm2) WORKING ZONE 1-1/2" 55 520
RECOMMENDED 2" 55 600
WORKING ZONE

Q (m3/h)

Q (m3/h)

48 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-SOL® | GEM-S | Pilot Operated 3/4” - 2” 2 Way NC, NO

Dimensions with flow control


Size A B C
3/4" 108 110 81
1" 135.5 110 81
1-1/2" 180 160 126
2" 190 170 126

without flow control


Size A B C
3/4" 128.5 110 81
1" 135.5 110 81
1-1/2" 168 160 126
2" 179.5 170 126

How to Order * When ordering without coil, please define what


current and pressure rating is needed (DC, AC)

MANUAL FLOW
GEM-S - BODY PORT FUNCTION SEALS
OVERRIDE CONTROL - VOLTAGE POWER CONNECTOR

W/out
Plastic 4 3/4" BSPT 50 2W NC 1 NR N None 0 with 1 0 No coil 0 without 0
coil
AC8W
3/4" NPT 51 2WNO 2a Plastic 1 without (1)
2 6 1 50Hz 1 with 1

AC8W
1" BSPT 60 12 2 2 with LED 2
60Hz

with bi- color 3


1" NPT 61 24 3 DC10W 3 LED

AC5.5W flying
1-1/2"BSPT 70 48 4 4 4
50Hz leads coil

AC5.5W with 1/2"


1-1/2"NPT 71 110 5 5 5
60Hz Hub
surge
2" BSPT 80 120 6 protection 6
with LED
connector
2" NPT 81 220 7A with moulded 7
cable
230 7 other 9
Example: GEM-S-4501N11-331
GEM-SOL® pilot operated, nylon body, 3/4" BSPT, 2W NC, NR, 240 8
plastic manual override, with flow control, 24V DC 10W with connector
Latch/ 9
GEM-S 4 50 1 N 1 1 3 3 1 other (2)

(1) 3/4", 1" valves only


(2) For specifying Latch type coil, please refer to GEM-A3P valve - How to Order table

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 49
ELECTRIC & HYDRAULIC VALVES

GEM-SOL® | GEM-S-4
Upstream Pilot Control Integrated with GEM-SOL® Operator
3/4” - 2” 2 Way NC, NO
Technical Data
Function 2 Way NC, NO
Ports size 3/4”, 1”, 1-1/2”, 2” BSPT & NPT
Connection Female BSPT or NPT thread
Pressure range 0.3 to 10 bar
Fluid: 5ºC to 50ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
Solenoid GEM-SOL® (GEM-OG)
Manual override:
Plastic (Reinforced Nylon)
Body & cover:
Plastic (Reinforced Nylon)
Spring:
Stainless Steel AISI 302
Materials in contact Diaphragm:
with media NR
Seals:
NBR
Screws:
Stainless Steel AISI 304
Solenoid:
Stainless Steel AISI 300 & 400 series
• Voltage and power consumption - see table
Coil voltage
• All Baccara coil voltages are ± 10% of nominal
IP65 with connector
Standard protection class
* Option: IP68 (please refer to GEM-BP Coil)
• Progressive opening and shut off that prevents water hammer

Head Loss for Fully Open Valve

H
H )
(kg/cm 2
" "
3/4 3/4

(kg/cm2)
1" 1"

RECOMMENDED WORKING ZONE


RECOMMENDED WORKING ZONE

Q (m3/h)
Q (m3/h) Flow Flow
direction
direction

Head Loss for Fully Open Valve Flow Factor & Orifice
Orifice Kv
Size
(mm) (l/min)
/2 " /2 "

3/4" 27 140
1- 1 1- 1

2 " 2 "

H
(kg/cm 1" 27 200
H )
2

(kg/cm2) RECOMMENDED 1-1/2" 55 520


WORKING ZONE
RECOMMENDED 2" 55 600
WORKING ZONE

Q (m3/h)
Q (m3/h)

50 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-SOL® | GEM-S-4 | Upstream Pilot Control Integrated with


GEM-SOL® Operator 3/4” - 2” 2 Way NC, NO

Dimensions

.4 08.

.4
80

How to Order * When ordering without coil, please define what


current and pressure rating is needed (DC, AC)

MANUAL FLOW
GEM-S-4 - BODY PORT FUNCTION SEALS
OVERRIDE CONTROL - VOLTAGE POWER CONNECTOR

W/out
Plastic 4 3/4" BSPT 50 2W NC 1 NR N None 0 with 1 0 No coil 0 without 0
coil
AC8W
3/4" NPT 51 2WNO 2a Plastic 1 without (1)
2 6 1 50Hz 1 with 1

AC8W
1" BSPT 60 12 2 2 with LED 2
60Hz

with bi- color 3


1" NPT 61 24 3 DC10W 3 LED

AC5.5W flying
1-1/2”BSPT 70 48 4 4 4
50Hz leads coil

AC5.5W with 1/2"


1-1/2”NPT 71 110 5 5 5
60Hz Hub
surge
2” BSPT 80 120 6 protection 6
with LED
connector
2” NPT 81 220 7A with moulded 7
cable
230 7 other 9

240 8

Latch/ 9
other (2)
Example: GEM-S-4-4501N11-331
GEM-SOL® pilot operated upstream, nylon body, 3/4" BSPT, 2W NC, NR seals,
plastic manual override, with flow control, 24V DC 10W with connector

GEM-S-4 4 50 1 N 1 1 3 3 1

(1) 3/4", 1" valves only


(2) For specifying Latch type coil, please refer to GEM-A3P valve - How to Order table

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 51
ELECTRIC & HYDRAULIC VALVES

GEM-FLOW™ | G75-S
Pilot Operated 1/2” 2 Way NC

Technical Data
Function 2 Way NC
Ports size 1/2" BSP & NPT
Orifice size 12mm
0.5 to 12 bar
Pressure range * Minimum pressure differential of 0.5
is required
Kv (l/min) 35 l/min
Fluid: 5ºC to 50ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
Main Valve:
Plastic (Reinforced Nylon)
Solenoid Operator:
Materials in contact Stainless Steel AISI 300 & 400 series
with media Seals:
NBR, EPDM, FKM
Spring:
Stainless Steel AISI 300 series
Solenoid G75 2W NC solenoids, all voltages.
• Voltage and power consumption - see table
Coil voltage
• All Baccara coil voltages are ± 10% of nominal
Standard protection class IP65

Voltage & Power Consumption


AC (W)
DC (W)
50 Hz
V 2 4.5
12 • •
24 • •
110 •
2 Way only

• Available options

Voltage & Current


Flow direction
AC & DC
Solenoid Voltage Inrush [A] Holding [A]
2 Way 50 Hz 0.3 0.19
+10%
V
2 Way 60 Hz 0.2 0.14
3 Way 50/60 Hz n-20% 0.125 0.125
DC 4.5W

Latch Coil Resistance vs Input Voltage


Recommendations chart
Resistance [Ω] Input voltage range [V]
4 6-9
9 12 - 14
12 14 - 16
23 18 - 21

52 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G75-S | Pilot Operated 1/2” 2 Way NC

Dimensions

How to Order
MANUAL
G75-S - BODY PORT FUNCTION SEALS
OVERRIDE - VOLTAGE (1) WIRES

Plastic 4 1/2” BSP 40 2W NC 1 NBR N None 0 24V AC 1 two null


1/2” NPT 41 FKM V 12V AC 3 three (2) a
EPDM E 12V DC 4
24V DC 5
23Ω 6
110V AC 7
4Ω B

9Ω C

12Ω D

Example: G75-S-4401N0-1
G75 pilot operated, 1/2" BSP, 2W NC, NBR, no manual override,
24V AC, two wires

G75-S 4 40 1 N 0 1

(1) For Latch: Refer to Latch Coil Resistance vs Input Voltage | Recommendations chart
(2) For Latch only

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 53
ELECTRIC & HYDRAULIC VALVES

GEM-FLOW™ | G75-S
Electric 3/4” - 2” 2 Way NC

Technical Data
Function 2 Way NC
Ports size 3/4", 1", 1-1/2", 2" BSPT & NPT
Pressure range 0.3 to 10bar
(Fluid: 5ºC to 50ºC (no freezing
Temperature range
Ambient: -10ºC to 50ºC
Manual override:
Plastic (Reinforced Nylon)
Main Valve:
Plastic (Reinforced Nylon)
Solenoid Operator:
Materials in contact Stainless Steel AISI 300 & 400 series
with media Diaphragm:
NR
Seals:
NBR
Spring:
Stainless Steel AISI 300 series
G75-S | 1" | NC with G75-S | 2" | NC Latch with
plastic manual override handle manual override
• G75, 2W NC solenoids, all voltages.
Solenoid
• AC, DC and Latch
• Voltage and power consumption - see table
Coil voltage
• All Baccara coil voltages are ± 10% of nominal

Voltage & Current


AC & DC
Solenoid Voltage Inrush [A] Holding [A]
2 Way 50 Hz 0.3 0.19
+10%
V
2 Way 60 Hz 0.2 0.14
3 Way 50/60 Hz n-20% 0.125 0.125
DC 4.5W

Voltage & Power Consumption H


(kg/cm2)
"
3/4

AC (W)
1"

DC (W) RECOMMENDED WORKING ZONE


50 Hz
Flow direction
V 2 4.5
with flow control without flow control
12 • •
24 • • Q (m3/h)

Head Loss for Fully Open Valve
110 2 Way only
• Available options

Head Loss for Fully Open Valve


/2 "
1- 1

2 "

H
(kg/cm2)
RECOMMENDED
WORKING ZONE
H
(kg/cm2)
"
3/4

1"

RECOMMENDED WORKING ZONE


Q (m3/h)

Q (m3/h) Latch Coil Resistance vs Input Voltage


Recommendations chart
Resistance [Ω] Input voltage range [V]
4 6-9
9 12 - 14
/2 "
1- 1

2 "

H 12 14 - 16
(kg/cm2)
54 A U T O M A T I O N & C O N T R O L
RECOMMENDED
WORKING ZONE
23 18 - 21
AGRICULTURE

GEM-FLOW™ | G75-S | Electric 3/4” - 2” 2 Way NC

Dimensions 3/4" & 1" Size


3/4" 105
A B
110
C
105
D
81
Weight (gr)
230
1" 112 110 112 81 230
1-1/2" 180 160 126 127 740
2" 190 170 126 127 790

1- 1/2 " & 2 " with integrated solenoid

With flow control

Without flow control

How to Order
MANUAL FLOW
G75-S - PORT FUNCTION
OVERRIDE CONTROL
VOLTAGE (3) WIRES

3/4" BSPT 50 2W NC 1 None 0 with 5 24V AC 1 two null


3/4" NPT 51 Plastic 1 without (2) 6 12V AC 3 three (1)
a
1" BSPT 60 Handle (1)
2 12V DC 4
1" NPT 61 24V DC 5
1-1/2" BSPT 70 23Ω 6
1-1/2" NPT 71 110V AC 7
2" BSPT 80 4Ω B
2" NPT 81 9Ω C
12Ω D

Example: G75-S-501051
G75 electric valve, 3/4" BSPT, 2W NC, no manual override,
with flow control, 24V AC, two wires

G75-S 50 1 0 5 1

(1) For Latch only


(2) 3/4", 1" valves only
(3) For Latch: Refer to Latch Coil Resistance vs Input Voltage | Recommendations chart

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 55
ELECTRIC & HYDRAULIC VALVES

GEM-SOL® | GEM-Z
Zero Differential Pressure 1/4” - 3/4” 2 Way NC, NO

Technical Data
Function 2 Way NC, NO
Ports size 1/4", 1/2", 3/4" BSP & NPT
See table
Pressure range * For plastic body, maximum working
pressure is 4 bar
Kv (l/min) See table
Fluid: -10ºC to 80ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
Main Valve:
Brass, Stainless Steel AISI 316,
Plastic (Reinforced Nylon)*
* Plastic (Reinforced Nylon): only available Brass | 1/2" | NC Plastic | 1/2" | NC
Materials in contact
in 1/2”
with media
Solenoid Operator:
Stainless Steel AISI 300 & 400 series
Seals:
NBR, FKM, EPDM
Media Air, water, oil
• Voltage and power consumption - see table
Coil voltage
• All Baccara coil voltages are ± 10% of nominal
IP65 with connector
Standard protection class
* Option: IP68 (please refer to GEM-BP Coil)
• When switching from an AC to a DC coil, the solenoid operator must be changed as well.
• Can be used in vacuum application from -1 bar to maximum pressure - see tables. Stainless Steel | 1/2" | NC

Pressure (bar) & Flow NC (GEM-Z)


Pressure (bar)
Size Orifice (mm) Kv (l/min)
AC DC
1/4" 8 0 to 14 0 to 7 12
1/2" 12 0 to 14 0 to 8 18

Pressure (bar) & Flow NC (GEM-Z-□□r)


Pressure (bar)
Size Orifice (mm) Kv (l/min)
AC DC
1/2" 16 0 to 10 0 to 6 60 GEM-Zr
3/4" 16 0 to 10 0 to 6 80 Flow direction

Pressure (bar) & Flow NO (GEM-Z) Voltage & Power Consumption


Orifice Pressure (bar) AC (W)
Size Kv (l/min) DC (W)
(mm) AC DC 50 Hz 60 Hz
1/4" 8 0 to 8 0 to 8 12 V 8 5.5 2.5 8 5.5 2.5 10 5.5 3.5
1/2" 12 0 to 8 0 to 8 20 6 •
12 • • •
24 • • •
48 • • •
110 • • •
120 • •
220 • • •
230 • • •
240 • • •
• Available options

56 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-SOL® | GEM-Z | Zero Differential Pressure 1/4” - 3/4” 2 Way NC, NO

Dimensions Size A B C D E F
Weight
with coil
1/4" 22 22 32 58 89 1/4" BSP/NPT 415gr.
1/2" 22 22 38 70 95 1/2" BSP/NPT 530gr.

GEM - Z -  r
1 mm ori ce - 1/2" / "
GEM-Z-4....
Nylon Valve Body

95.4
1/2 ” o r

1/2"
3/4” BS P /N P T

13
42.5 70
67.4

How to Order * When ordering without coil, please define what


current and pressure rating is needed (DC, AC)

GEM-Z - BODY PORT FUNCTION SEALS - VOLTAGE POWER CONNECTOR

Brass 2 1/4" BSP 20 2W NC 1 NBR N W/out coil 0 No coil 0 without 0


Stainless AC8W
3 1/4" NPT 21 2W NO (4)
2a FKM V 6 1 1 with 1
Steel (1) 50Hz
AC8W
Plastic (2) 4 1/2”BSP 40 EPDM E 12 2 2 with LED 2
60Hz
with bi- color
1/2”NPT 41 24 3 DC10W 3 3
LED
1/2”BSP 40r 48 4 flying leads coil 4
1/2”NPT 41r 110 5 with 1/2" Hub 5
surge protec-
3/4”BSP 50r 120 6 6
tion with LED
connector with
3/4”NPT (3) 51r 220 7A 7
moulded cable

230 7 other 9

240 8

Latch/
9
other (5)

Example: GEM-Z-2401N-221
GEM-SOL® zero differential, brass, 1/2" BSP, 2W NC,
NBR, 12V AC8W 60Hz with connector

GEM-Z 2 40 1 N 2 2 1

(1) Not available for GEM-Z-r


(2) Only available in 1/2”
(3) 16mm orifice
(4) NO function without M/O, not available for GEM-Z-r
(5) For specifying Latch type coil, please refer to GEM-A3P valve - How to Order table

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 57
ELECTRIC & HYDRAULIC VALVES

GEM-FLOW™ | G75-S
Hydraulic 3/4”- 2” 2 Way

Technical Data

Function 2 Way
Ports size 3/4", 1", 1-1/2", 2" BSPT & NPT
Pressure range 0.3 to 10bar
Temperature range Fluid: 5ºC to 50ºC (no freezing)
Main Valve:
Plastic (Reinforced Nylon)
Diaphragm:
Materials in contact NR
with media Seals:
Buna - N
Spring:
Stainless Steel AISI 300 series No inline pilot port | Upstream inline pilot port |
with flow control with flow control

Head Loss for Fully Open Valve

H
(kg/cm2)
"
3/4

H
(kg/cm2)
1"
"
3/4

RECOMMENDED WORKING ZONE


1"

RECOMMENDED WORKING ZONE

Flow direction
Q (m3/h) with flow control without flow control
Q (m3/h)

Head Loss for Fully Open Valve


/2 " /2 "
1- 1 1- 1

2 "

H
(kg/cm2)
2 "

H RECOMMENDED
(kg/cm2) WORKING ZONE
RECOMMENDED
WORKING ZONE

Q (m3/h)

Q (m3/h)

58 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G75-S | Hydraulic 3/4”- 2” 2 Way

Dimensions 3/4" & 1" Size A B C D E ØG Weight


(gr.)
3/4" 105 110 77 81 52.5 1/8"NPT/BSP 230
1/8" BSP / NPT
1" 112 110 84 81 48.5 1/8"NPT/BSP 230
THREAD
1-1/2" 180 160 98 127 92 1/4"NPT/BSP 740
(G)
2" 190 170 98 127 94 1/4"NPT/BSP 790
A

1-1/2" & 2" With Integrated Solenoid

D E

A
B
With flow control

E Thread
Thread B (G)
(G)

Downstream port (G) Upstream port (G)

Without flow control

How to Order
FUNCTION
FLOW
G75-S - PORT INLINE PILOT
CONTROL
PORTS

3/4" BSPT 50 none 0 with 5


upstream
3/4" NPT 51 1 without (1)
6
only
downstream
1" BSPT 60 2
only
1" NPT 61 both 3
1-1/2" BSPT 70
1-1/2" NPT 71
2" BSPT 80

2" NPT 81

Example: G75-S-5015
G75 hydraulic valve, 3/4" BSPT, 1/8" upstream inline pilot port, with flow control

G75-S 50 1 5

(1) 3/4", 1" valves only

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 59
ELECTRIC & HYDRAULIC VALVES

GEM-FLOW™ | G75-S
3 Way Integral Solenoid Pilot Control 3/4” - 2” NC

Technical Data
Solenoid Supplied with 3 Way NO 1.2mm G75 operator
Upstream pilot control valve is supplied with
Assembly
finger filter and accessories
• For technical information, refer to G75-S | Electric 3/4” - 2” 2 Way NC

Voltage & Power Consumption


AC (W)
DC(W)
50 Hz
V 2 4.5
12 • • Upstream pilot External pilot
24 • • control control
• Available options

Voltage & Current


Solenoid Voltage Inrush [A] Holding [A]
2 Way 50 Hz 0.3 0.19
+10%
V
2 Way 60 Hz 0.2 0.14
3 Way 50/60 Hz * n-20% 0.125 0.125
DC 4.5W
* Except 24V AC without Diode

Latch Coil Resistance vs Input Voltage Upstream pilot


control
External pilot
control
Recommendations chart
Resistance [Ω] Input voltage range [V]
4 6-9
9 12 - 14
12 14 - 16
23 18 - 21

How to Order
Example: G75-S-704151
MANUAL FLOW CON-
G75-S - PORT FUNCTION
OVERRIDE TROL
VOLTAGE (3) WIRES G75 1-1/2" BSPT, external pilot, plastic manual
override, with flow control, 24V AC, two wires
External
3/4" BSPT 50 4 None 0 with 5 24V AC 1 two null
pilot
24V AC G75-S 70 4 1 5 1
Upstream
3/4" NPT 51 Plastic 1 without(1) 6 w/out 1R three(2) a
pilot 4H
Diode (1) For 3/4", 1" valves only
1" BSPT 60 Handle(2) 2 12 V AC 3 (2) For Latch only
1" NPT 61 12 V DC 4 (3) For Latch: Refer to Latch Coil Resistance vs
Input Voltage | Recommendations chart
1-1/2" BSPT 70 24V DC 5
1-1/2" NPT 71 23Ω 6
2" BSPT 80 4Ω B
2" NPT 81 9Ω C
12Ω D

* To order valves manufactured according to your specific requirements, please contact our technical sales department

60 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G75-SE
3 Way External Solenoid Pilot Control 3/4” - 2” NC, NO

Technical Data
Supplied with 3 Way 1.2mm G75 solenoid
Solenoid
or G75-A3P 2.6 mm latch
Assembly Supplied with finger filter and accessories
• For technical information, refer to G75-S | Electric 3/4” - 2” 2 Way NC

Voltage & Power Consumption


AC (W)
DC(W)
50 Hz
V 2 4.5
12 • • NC valve NO valve
24 • •
• Available options

Voltage & Current


AC & DC
Inrush Holding
Solenoid Voltage
[A] [A]
2 Way 50 Hz 0.3 0.19
+10%
V
2 Way 60 Hz 0.2 0.14
3 Way 50/60 Hz * n-20% 0.125 0.125
DC 4.5W
* Except 24V AC without Diode

How to Order NC valve NO valve

G75-SE - PORT FUNCTION(3)


MANUAL FLOW
VOLTAGE (4) WIRES
Latch Coil Resistance
vs Input Voltage
OVERRIDE CONTROL
3/4" BSPT 50 2W NC 1 None 0 with 5 24V AC 1 two null
24V AC
3/4" NPT 51 2W NO 2 Plastic 1 without(1) 6
w/out Diode
1R three(2) a Recommendations chart
1" BSPT 60 12 V AC 3 G75-A Latch
1" NPT 61 12 V DC 4 Resistance [Ω] Input voltage range [V]
1-1/2" BSPT 70 24V DC 5 4 6-9
9 12 - 14
1-1/2" NPT 71 23Ω 6
12 14 - 16
2" BSPT 80 4Ω B 23 18 - 21
2" NPT 81 9Ω C G75-A3P Latch
12Ω D Resistance [Ω] Input voltage range [V]
1Ω (5) PA 1 8 - 12
Example: G75-SE-702151 4 12 - 18
4Ω (5) PB
G75 1-1/2" BSPT, 2W NO, plastic manual override, 9 18 - 24
9Ω (5) PC
with flow control, 24V AC, two wires

G75-SE 70 2 1 5 1

(1) For 3/4", 1" valves only


(2) For Latch only
(3) Refers to the valve:
3 Way NC solenoid = NO valve
3 Way NO solenoid = NC valve
(4) For Latch: Refer to Latch Coil Resistance vs Input Voltage | Recommendations chart
(5) For G75-A3P Latch

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 61
ELECTRIC & HYDRAULIC VALVES

GEM-FLOW™ | G75
3 Way Manual Selector 3/4” - 2” NC, NO
Technical Data
Supplied with 3 Way 1.2mm G75 solenoid
Solenoid
or G75-A3P 2.6 mm latch
Assembly Supplied with finger filter and accessories
Manual override with 3 positions:
• AUTO - for automatic operation (valve is open
Manual override when solenoid is energized)
• MANUAL - valve is kept open
• CLOSE - valve is kept closed
Pressure A minimum pressure differential of 1 bar is required
• For technical information, refer to G75-S | Electric 3/4” - 2” 2 Way NC

Voltage & Power Voltage & Current 3 Way Manual selector With solenoid
Consumption AC & DC
AC (W) Inrush Holding
DC(W) Solenoid Voltage
[A] [A]
50 Hz
2 Way 50 Hz 0.3 0.19
V 2 4.5 +10%
V
2 Way 60 Hz 0.2 0.14
12 • • 3 Way 50/60 Hz * 0.125 0.125
24 • • n-20%
DC 4.5W
• Available options
* Except 24V AC without Diode

Latch Coil Resistance


vs Input Voltage
Recommendations chart
G75-A Latch
Resistance [Ω] Input voltage range [V]
4 6-9
9 12 - 14
12 14 - 16
23 18 - 21
G75-A3P Latch
Resistance [Ω] Input voltage range [V] Flow direction
1 8 - 12
4 12 - 18 3 Way Manual Manual selector with
9 18 - 24 selector external
3 Way NO solenoid
How to Order
FLOW
G75 - TYPE - PORT FUNCTION(1)
CONTROL
VOLTAGE (4) WIRES

Hydraulic with
No solenoid
Manual SM 3/4" BSPT 50 2W NC 1 with 5 0 two null
(hydraulic)
Selector
Electric EL 3/4" NPT 51 2W NO 2 without (2) 6 24V AC 1 three (3)
a
Electric with
24V AC
Manual ELM 1" BSPT 60 1R
w/out Diode
Selector
1" NPT 61 12V AC 3 Example: G75-ELM-70151
G75 3 Way electric with manual selector, 1-1/2"
1-1/2" BSPT 70 12V DC 4
BSPT, 2W NC with flow control, 24V AC, two wires
1-1/2" NPT 71 24V DC 5
2" BSPT 80 23Ω 6
G75 ELM 70 1 5 1
2" NPT 81 4Ω B
9Ω C (1) Refers to the valve:
3 Way NC solenoid = NO valve
12Ω D 3 Way NO solenoid = NC valve
(2) For 3/4", 1" valves only
1Ω (5) PA
(3) For Latch only
4Ω (5) PB (4) For Latch: Refer to Latch Coil Resistance vs
Input Voltage | Recommendations chart
9Ω (5)
PC (5) For G75-A3P Latch
* To order valves manufactured according to your specific requirements, please contact our technical sales department

62 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G75
Pressure Reducing 3/4” - 2” 2 Way NC
Technical Data
Supplied with 3 Way NO 1.2mm G75 solenoid
Solenoid
or G75-A3P 2.6 mm latch
Assembly Supplied with finger filter
• Pilot pressure must be equal to, or higher than line
Pressure pressure
• A minimum pressure differential of 1 bar is required
• For technical information, refer to G75-S | Electric 3/4” - 2” 2 Way NC

Voltage & Power Voltage & Current


Consumption AC & DC
AC (W) Solenoid Voltage
Inrush Holding Pressure reducing | 0.5-5 bar / 1-10 bar
DC(W) [A] [A]
50 Hz
V 2 4.5 2 Way 50 Hz 0.3 0.19
+10%
12 • • 2 Way 60 Hz 0.2 0.14
Pressure Reducing | PR
24 • • 3 Way 50/60 Hz * n-20% 0.125 0.125
• Available options DC 4.5W
* Except 24V AC without Diode

Latch Coil Resistance vs Input Voltage


Recommendations chart
G75-A Latch
Resistance [Ω] Input voltage range [V]
4 6-9
9 12 - 14
12 14 - 16
23 18 - 21
G75-A3P Latch
Resistance [Ω] Input voltage range [V]
1 8 - 12
4 12 - 18
9 18 - 24

How to Order
FLOW PRESSURE
G75 - TYPE - PORT FUNCTION
CONTROL
VOLTAGE (3) WIRES
RANGE
Pressure No solenoid
PR 3/4" BSPT 50 2W NC 1 with 5 0 two null 0.5-5 bar Y
Reducing (hydraulic)
With Manual
PRM 3/4" NPT 51 without(1) 6 24V AC 1 three(2) a 1-10 bar G
Selector
Electric Without 24V AC
PREL 1" BSPT 60 1R
Manual Selector w/out Diode
Electric With
PRELM 1" NPT 61 12V AC 3 Example: G75-PR-70151Y
Manual Selector
G75 pressure reducing valve, 1-1/2" BSPT,
1-1/2" BSPT 70 12V DC 4 2W NC with flow control, 24V AC, two wires,
1-1/2" NPT 71 24V DC 5 0.5-5 bar
2" BSPT 80 23Ω 6
2" NPT 81 4Ω B G75 PR 70 1 5 1 Y
9Ω C
12Ω D
(1) For 3/4", 1" valves only
(2) For Latch only
1Ω (4) PA
(3) For Latch: Refer to Latch Coil Resistance vs
4Ω (4) PB Input Voltage | Recommendations chart
9Ω (4) PC (4) For G75-A3P Latch

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 63
A U T O M A T I O N & C O N T R O L
ELECTRIC & HYDRAULIC
VALVES | G500
GEM-FLOW™ | 500 Series Hydraulic Control Valves ................................................................................................... 66
GEM-FLOW™ Operating Principals ............................................................................................................ 67
GEM-FLOW™ Available Models.................................................................................................................... 68
GEM-FLOW™ Hydraulic Performance ....................................................................................................... 69
GEM-FLOW™ | G500 4” Hydraulic Valves ............................................................................................................... 70
GEM-FLOW™ | G500-S Hydraulic with Manual Selector 1-1/2” - 4” ................................................................ 72
GEM-FLOW™ | G500-EL Electric Solenoid Control Valve 1-1/2” - 4” ................................................................. 73
GEM-FLOW™ | G500-C DC Battery Controller 1-1/2” - 4” ..................................................................................... 74
GEM-FLOW™ | G500-PR Pressure Reducing 1-1/2” - 4” .......................................................................................... 75
GEM-FLOW™ | G500-PREL Solenoid Controlled Pressure Reducing 1-1/2” - 4” ............................................... 76
GEM-FLOW™ | G500-PRPS Pressure Reducing & Sustaining Control Valve 1-1/2” - 4” ................................. 77
GEM-FLOW™ | G500-QR Quick Pressure Relief 1-1/2” - 4” ...................................................................................... 78
GEM-FLOW™ | G500-PS Pressure Sustaining Control Valve 1-1/2” - 4” ........................................................... 79

Tackling climate
change together
ELECTRIC & HYDRAULIC VALVES | G500

GEM-FLOW™ | 500 Series


Hydraulic Control Valves

General Description
500 series valves are direct diaphragm closing automatic
hydraulic control valves which work with line pressure. They
ensure easy and smooth flow with minimum pressure losses
thanks to excellent design of the valve body and diaphragm.
No wearable parts such as stem, bearing and seat exist in
the main valve body and valve life is much longer than other
competitor valves. The only movable part of the valve is the
valve diaphragm.

500 series hydraulic control valves are designed so that they


can be used in portable water force
network, agricultural irrigation, filtration and industrial
applications by even unskilled personnel.

General Features
• Easy use and maintenance due to simple design
• Low cost
• Operation in wide pressure range
• Perfect modulation even in lower flow rates
• Anti-surge closing and opening with flexible diaphragm
• Full tightness thanks to reinforced diaphragm and inner
spring
• Long life with Glass Reinforced Polyamide material
• Wide control application range by using different pilot valves
• Operation in both horizontal and vertical positions in
application areas

66 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™
Operating Principals

It is an automatic hydraulic control valve designed to make desired modulation in main valve network line as full
hydraulically by means of line pressure without requiring different energy sources such as electric, pneumatic or
mechanical energy.

Valve Opening Mode


When the pilot valve located on the main valve being in closed
position, is brought into relief position, pressurized water within
control chamber on main valve diaphragm is released. When line
pressure (P1) reaches to a value which will overcome spring force,
water carries valve to fully open position by applying a hydraulic force
to valve diaphragm from bottom.

Modulation Mode
Pilot valves which are connected to main valve actuator ensure
that main valve works in modulated mode. According to flow rate or
pressure conditions, it ensures that main valve works in modulation
mode by controlling pressure of fluid within main valve actuator
(control chamber).

Valve Closing Mode


Pilot valves which are connected to main valve actuator ensure
that main valve works in modulated mode. According to flow rate or
pressure conditions, it ensures that main valve works in modulation
mode by controlling pressure of fluid within main valve actuator
(control chamber).

Tackling climate
change together 67
ELECTRIC & HYDRAULIC VALVES | G500

GEM-FLOW™
Available Models

Technical Data
Pressure range Standard 0.7 - 10 bar (10 - 160 psi)
Fluid (-10ºC to 60ºC (no freezing
Temperature range
Ambient -10ºC to 60ºC
Connection Threaded BSPT-NPT
Reinforced Nylon (Air Brake)
Hydraulic connections Standard
Hydraulic Pipe-SAE J 844
Diaphragm Closing Type with Single
Actuator type Standard
Control Chamber and Diaphragm Actuator

Available Models
MODEL G500
Connection Threaded
Material Glass reinforced polyamide
Body Globe H
Maximum working pressure 10 bar 160psi

D
inch mm
1-1/2" 40
Available sizes 2" 50
2-1/2" 65 L
3" 80 model G500

Dimensions
DN D L H
inch mm inch mm inch mm inch mm
1-1/2" 40 2-1/2" 62 7-7/8" 200 4-3/8" 110
2" 50 3" 75 7-7/8" 200 4-3/8" 110
2-1/2" 65 3-3/4" 95 9-7/8" 250 5-3/8" 138
3" 80 4-1/4" 109 9-7/8" 250 5-3/8" 145

Order Information
Please submit following information to our sales department when ordering:

Maximum flow rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . m3/h


Maximum network/line pressure. . . . . . . . . . . . . . . . . . . . . . bar
Main line size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . mm
Valve connection type
Maximum upstream pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . bar
Minimum upstream pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . bar
Desired downstream pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . bar
Electric voltage value to be used . . . . . . . . . . . . . . . . . . . . . volt

68 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™
Hydraulic Performance

Hydraulic Performance Chart


mm 40 50 65 80
VALVE SIZE
inch 1-1/2" 2" 2-1/2" 3"
Kv m3/h @ 1 bar 60 70 80 90
Cv gpm @ 1 psi 70 85 95 105

G
• Kv: Valve Flow Coefficient (fluid passing under 1 bar pressure difference in m3/h @ 1 bar) Kv, (Cv) =Q
√ P
• Cv: Valve Flow Coefficient (fluid passing under 1 bar pressure difference in gpm @ 1 bar) Cv=1,155 Kv
• Q: Flow Rate (m3/h)
• P: Head Loss (bar)
• G: Specific weight of water (1.0 for water)

Head Loss Chart


10
HeadLoss (mSS)

40

50

80
65

DN40
DN
DN

DN
DN

DN50
DN65
DN80

1
10 Flow Rate (m3/h) 100

Main Parts 6
2
NO. PART NAME MATERIAL
1 Body Glass reinforced polyamide
2 Bonnet Glass reinforced polyamide 5
3 Diaphragm Natural Rubber
4
4 Spring thrust ring Glass reinforced polyamide
5 Spring SST302
3
6 Bolt SST304
7 Nut Brass

Tackling climate
change together 69
ELECTRIC & HYDRAULIC VALVES | G500

GEM-FLOW™ | G500
4” Hydraulic Valves

Typical Applications
• Agricultural irrigation
• Landscaping applications
• Greenhouse applications
• Mining process
• Industrial process

Technical Data
General Specifications
Pressure range 0.7~10 bar / 9~145 Psi
Temperature range -10ºC to 80ºC (no freezing)
Valve size 4” (100 mm)
Material Properties
Body | Cover PA GFR
Diaphragm NR
Spring thrust ring PA GFR
Spring Stainless Steel AISI 302
Bolts Stainless Steel A2
Flange, Flange adaptor PA GFR
Threaded adaptor PA GFR
O-rings NBR
Connection
Flanged ISO, ANSI
Threaded BSP, NPT

Head Loss Chart


10
Head loss (mwc)

100
DN

1
10 Flow Rate (m3/h) 100

70 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G500 | 4” Hydraulic Valves

Hydraulic Specifications
Maximum continuous flow 100 m3/h
Maximum intermittent flow 145 m3/h
Minimum working pressure 0.7 bar
Maximum working pressure 10 bar
Kv 115 m3/h @ 1 bar

Dimensions

H2
H1

L2

L1

L1 280 mm
L2 350 mm
H1 220 mm
H2 180 mm
W1 213 mm
W2 172 mm
Port Connections 1/4” BSP, 1/4” NPT
Weight (Flange type) 2.6 kg
Weight (Threaded type) 1.9 kg

Available Applications
Basic valve B
Manual control valve M
Solenoid control valve EL
Electric control valve + control device (1 outlet) EL/C
Pressure reducing control valve PR
Solenoid controlled pressure reducing valve PREL
Pressure reducing & sustaining control valve PRPS
Quick pressure relief control valve QR
Pressure sustaining valve PS
Float level control valve FL
Electric float level control valve FLEL
Flow rate control valve FR

Tackling climate
change together 71
ELECTRIC & HYDRAULIC VALVES | G500

GEM-FLOW™ | G500-S
Hydraulic with Manual Selector 1-1/2” - 4”

Description
G500-S model valve is the hydraulic control valve operated by line pressure
and designed to ensure opening/closing process by means of a 3 Way
selector valve. Minimum opening pressure of valve is 0.7 bar. Thanks to its
flexible diaphragm, it makes easy and fast control process in high pressure
applications and is closed completely tight without causing surge. It may be
used in different applications by adding different pilot valves on its main body.

Applications
• Use G500-S for local operation of hydraulic valve by a manual command
• Use G500-S for water distribution and field

Standards
• G500-S: manual control valve with 3 Way selector valve, polyethylene
plastic tubing and nylon fittings

How to Order
G500 - TYPE - PORT

Hydraulic S 1-1/2" BSPT 70


with Manual
SM 1-1/2" NPT 71
Selector
2" BSPT 80
2" NPT 81
2-1/2"BSPT 85
2-1/2" NPT 86
3" BSPT 90
3" NPT 91 a 3W selector valve
b In-line finger filter
4" BSPT 100
c Plug
4" NPT 101
4" Flange 100F

Example: G500-SM-80
G500 Hydraulic
with manual selector, 2" BSPT

G500 SM 80

* To order valves manufactured according to your specific requirements, please contact our technical sales department

72 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G500-EL
Electric Solenoid Control Valve 1-1/2” - 4”

Description
G500-EL model valve is the hydraulic control valve operated by line pressure
and designed to ensure opening/closing process by means of built-in 3 Way
solenoid pilot valve controlled remotely with electric signal*. Electric signal
for solenoid pilot valve is ensured by means of a control device, time relay,
main switch and PLC control units etc. Opening/Closing process may be
realized easily thanks to manual control on solenoid pilot valve, depending
on requirements, 24V AC 50Hz/60Hz or 12V DC, 9V Latch and 12V DC Latch
normally open (NO) or normally closed (NC), solenoids coils may be used on
main valve.
* For technical information, refer to G75-A and G75-A3P solenoid valves

Applications
• Use G500-EL to remove operation of hydraulic valve by an electric
command
• Use G500-EL for water distribution

Standards
• G500-EL: 3 Way NO Solenoid, polyethylene plastic tubing system and nylon
fittings
• G500-ELM: 3 Way NO Solenoid, polyethylene plastic tubing system, nylon
fittings and 3 Way selector

How to Order
G500 - TYPE - PORT VOLTAGE WIRES

No solenoid
Electric EL 1-1/2" BSPT 70 0 two null
(hydraulic)
with Manual a 3W selector valve
ELM 1-1/2" NPT 71 24V AC 1 three (2)
a b In-line finger filter
Selector
24V AC c Plug
2" BSPT 80 1R d Solenoid Pilot Valve
w/out Diode
2" NPT 81 12V AC 3
2-1/2" BSPT 85 12V DC 4
2-1/2" NPT 86 24V DC 5
3" BSPT 90 23Ω 6
3" NPT 91 4Ω B
4" BSPT 100 9Ω C
4" NPT 101 12Ω D
4" Flange 100F 1Ω (1)
PA
4Ω (1) PB
9Ω (1)
PC

Example: G500-ELM-801
G500 Electric with manual selector, 2" BSPT, 24V AC, two wires

G500 ELM 80 1

(1) For G75-A3P Latch


(2) For Latch only

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 73
ELECTRIC & HYDRAULIC VALVES | G500

GEM-FLOW™ | G500-C
DC Battery Controller 1-1/2” - 4”

Description
G500-C model valve is the hydraulic control valve operated by line pressure
and designed to ensure opening/closing process by means of built-in
solenoid pilot valve controlled remotely with electric signal at required time or
required duration. Electric signal for solenoid pilot valve is ensured by means
of a control device, time relay, main switch and PLC control units etc. Opening/
Closing process may be realized easily thanks to manual control on solenoid
pilot valve, depending on requirements. The controller irrigates in cycles,
during a window of time according to your needs.

Applications
• Use G500-C for programmed irrigation
• Use G500-C for water distribution

Standards
• G500-C: 9V DC Latch solenoid, Control Unit (1 Outlet), polyethylene plastic
tubing system, nylon fittings and 3 Way selector

How to Order
G500-C - TYPE - PORT

One valve null 1-1/2" BSPT 70


Window W 1-1/2" NPT 71
Window + W+ 2" BSPT 80
2" NPT 81
a 3W selector valve
2-1/2" BSPT 85 b In-line finger filter
2-1/2" NPT 86 c Plug
d Solenoid Pilot Valve
3" BSPT 90
e Controller
3" NPT 91
4" BSPT 100
4" NPT 101
4" Flange 100F

Example: G500-C-W-90
G500 DC Battery controller,
Window, 3" BSPT

G500-C W 90

* To order valves manufactured according to your specific requirements, please contact our technical sales department

74 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G500-PR
Pressure Reducing 1-1/2” - 4”

Description
G500-PR model pressure reducing control valve is the hydraulic control valve
which reduces high upstream pressure value to
desired lower pressure value by means of built-in pressure reducing pilot
valve. Pressure reducing control valve controls
downstream pressure value continuously and maintains it constant without
being affected from flow rate and upstream pressure values. When no flow
exists in the system, it closes itself automatically. When valve upstream
pressure value is lower than set point, it is opened fully by itself. Valve may be
used in vertical or horizontal positions in the system.

Applications
• Use G500-PR for irrigation, water distribution and filtration systems
• Smart designed G500-PR provides high corrosion resistance

Standards
• G500-PR: 3 Way plastic pressure reducing pilot, polytethylene plastic tubing
system and nylon fittings
• G500-PRM: 3 Way plastic pressure reducing pilot, polytethylene plastic
tubing system, nylon fittings and 3 Way selector
• Standard pressure adjustment from factory: 2.5 bar

How to Order
PRESSURE
G500 - TYPE - PORT
RANGE
without Manual
PR 1-1/2" BSPT 70 0.5-5 bar Y
Selector
a 3W selector valve
with Manual
PRM 1-1/2" NPT 71 1-10 bar G b Plastic Pilot
Selector
c In-line finger filter
2" BSPT 80
2" NPT 81
2-1/2" BSPT 85
2-1/2" NPT 86
3" BSPT 90
3" NPT 91
4" BSPT 100
4" NPT 101
4" Flange 100F

Example: G500-PR-80G
G500 pressure reducing without
manual selector, 2" BSPT, 1-10 bar

G500 PR 80 G

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 75
ELECTRIC & HYDRAULIC VALVES | G500

GEM-FLOW™ | G500-PREL
Solenoid Controlled Pressure Reducing 1-1/2” - 4”

Description
G500-PREL model pressure reducing valve is the hydraulic control valve which
reduces high upstream pressure value into desired lower pressure value.
Control of main valve is achieved by means of built-in solenoid pilot valves*.
Electric signal for solenoid pilot valves is ensured by means of a control
device, time relay, main switch and PLC control units etc. Automated control
may be easily ensured by this way in application systems.
* For technical information, refer to G75-A and G75-A3P solenoid valves

Applications
• Use G500-PREL for water distribution, where downstream pressure should
be reduced, the valve is commanded to open

Standards
• G500-PREL: 3 Way plastic pressure reducing pilot, solenoid 24V AC NO,
polytethylene plastic tubing system and nylon fittings
• G500-PRELM: 3 Way plastic pressure reducing pilot, solenoid 24V AC NO,
polytethylene plastic tubing system and nylon fittings and 3 Way selector
• Standard pressure adjustment from factory: 2.5 bar

How to Order
PRESSURE
G500 - TYPE - PORT VOLTAGE WIRES
RANGE
without Man- No solenoid
PREL 1-1/2" BSPT 70 0 two null 0.5-5 bar Y
ual Selector (hydraulic)
with Manual
PRELM 1-1/2" NPT 71 24V AC 1 three (2)
a 1-10 bar G
Selector
24V AC
2" BSPT 80 1R
w/out Diode a 3W selector valve
2" NPT 81 12V AC 3 b Plastic Pilot
2-1/2" BSPT 85 12V DC 4 c In-line finger filter
d Solenoid Pilot Valve
2-1/2" NPT 86 24V DC 5
3" BSPT 90 23Ω 6
3" NPT 91 4Ω B
4" BSPT 100 9Ω C
4" NPT 101 12Ω D
4" Flange 100F 1Ω (1) PA

4Ω (1) PB
9Ω (1) PC

Example: G500-PRELM-851G
G500 Solenoid controlled pressure reducing, with manual selector,
2-1/2" BSPT, 24V AC, two wires, 1-10 bar

G500 PRELM 85 1 G

(1) For G75-A3P Latch


(2) For Latch only

* To order valves manufactured according to your specific requirements, please contact our technical sales department

76 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G500-PRPS
Pressure Reducing & Sustaining Control Valve 1-1/2” - 4”

Description
G500-PRPS model pressure reducing/sustaining hydraulic control valve
reduces valve downstream pressure to desired value by sustaining upstream
pressure. Two pilot valves exist on the valve. Pilot valve on upstream side
is the pressure sustaining pilot valve and sustains upstream pressure. The
other pilot valve is pressure reducing pilot valve and keeps downstream
pressure constant by
reducing it to desired value. Reducing/sustaining control valve pumps fluid
downwards; it ensures that the system works within
normal values by regulating overflow and high pressure in pumping systems.
It controls upstream and downstream pressure
continuously and keeps them within constant values.

Applications
• Use G500-PRPS for protecting booster pumps and preserving set pressure
downstream

Standards
• G500-PRPS: 3 Way plastic pressure reducing pilot, 3 Way plastic pressure
sustaining valve, polytethylene plastic tubing system, nylon fittings and 3
Way selector

How to Order
PRESSURE
G500-PRPS - PORT
RANGE
a 3W selector valve
1-1/2" BSPT 70 0.5-5 bar Y b In-line finger filter
1-1/2" NPT 71 1-10 bar G c1 Plastic Pressure Sustaining Pilot
c2 Plastic Pressure Reducing Pilot
2" BSPT 80
2" NPT 81
2-1/2" BSPT 85
2-1/2" NPT 86
3" BSPT 90
3" NPT 91
4" BSPT 100
4" NPT 101
4" Flange 100F

Example: G500-PRPS-80G
G500 pressure reducing & sustaining 2" BSPT, 1-10 bar

G500-PRPS 80 G

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 77
ELECTRIC & HYDRAULIC VALVES | G500

GEM-FLOW™ | G500-QR
Quick Pressure Relief 1-1/2” - 4”

Description
G500-QR model quick pressure relief valve is the safety control valve
designed to protect the system by releasing pressure surges,
which are caused by sudden changes in water speed due to pumps put into/
out of service, in water network elevation lines to the atmosphere quickly.
When network pressure exceeds set point, the valve opens by itself quickly
and protects the system by
releasing over pressure. When the line pressure decreases to normal level, it
is tightly closed slowly and automatically without
causing a surge.
* For technical information, refer to G75-A and G75-A3P solenoid valves

Applications
• Use G500-QR when wishing to avoid unwanted high pressure

Standards
• G500-QR: 3 Way plastic pilot, polytethylene plastic tubing system and nylon
fittings
• G500-QRM: 3 Way plastic pilot, polytethylene plastic tubing system and
nylon fittings and 3 Way selector

How to Order
PRESSURE
G500 - TYPE - PORT VOLTAGE WIRES
RANGE
without Manual No solenoid
QR 1-1/2" BSPT 70 0 two null 0.5-5 bar Y
Selector (hydraulic)
with Manual
QRM 1-1/2" NPT 71 24V AC 1 three (2) a 1-10 bar G
Selector
24V AC
2" BSPT 80 1R a 3W selector valve
w/out Diode
2" NPT 81 12V AC 3 b In-line finger filter
c Plastic Pilot
2-1/2" BSPT 85 12V DC 4
d Plug
2-1/2" NPT 86 24V DC 5
3" BSPT 90 23Ω 6
3" NPT 91 4Ω B
4" BSPT 100 9Ω C
4" NPT 101 12Ω D
4" Flange 100F 1Ω (1) PA
4Ω (1) PB
9Ω (1) PC

Example: G500-QR-701G
G500 quick pressure relief, without
manual selector, 1-1/2" BSPT, 24V AC,
two wires, 1-10 bar

G500 QR 70 1 G

(1) For G75-A3P Latch


(2) For Latch only

* To order valves manufactured according to your specific requirements, please contact our technical sales department

78 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G500-PS
Pressure Sustaining Control Valve 1-1/2” - 4”

Description
G500-PS model pressure sustaining hydraulic control valve maintains valve
upstream pressure value constant. Valve is opened when line pressure
reaches the preset pressure level. It ensures that pump motor within
pumping systems will start without load. It also prevents positive pressure
waves caused by pump during start-up. The valve controls upstream
pressure value continuously and keeps it at a constant value without being
affected from changes in flow rate. When no flow exists, it closes tightly by
itself.
* For technical information, refer to G75-A and G75-A3P solenoid valves

Applications
• Use G500-PS for maintaining a constant upstream pressure or to avoid
unwanted high pressure

Standards
• G500-PS: 3 Way plastic pressure sustaining pilot, polytethylene plastic
tubing system and nylon fittings
• G500-PSM: 3 Way plastic pressure sustaining pilot, polytethylene plastic
tubing system, nylon fittings and 3 Way selector
• Standard pressure adjustment from factory: 2.5 bar

How to Order
PRESSURE
G500 - TYPE - PORT VOLTAGE WIRES
RANGE
without Manual No solenoid
PS 1-1/2" BSPT 70 0 two null 0.5-5 bar Y
Selector (hydraulic)
with Manual
PSM 1-1/2" NPT 71 24V AC 1 three (2)
a 1-10 bar G
Selector
24V AC a 3W selector valve
2" BSPT 80 1R
w/out Diode b In-line finger filter
2" NPT 81 12V AC 3 c Plastic Pilot
2-1/2" BSPT 85 12V DC 4 d Plug
2-1/2" NPT 86 24V DC 5
3" BSPT 90 23Ω 6
3" NPT 91 4Ω B
4" BSPT 100 9Ω C
4" NPT 101 12Ω D
4" Flange 100F 1Ω (1) PA
4Ω (1) PB
9Ω (1) PC

Example: G500-PSM-801G
G500 pressure sustaining with
manual selector, 2" BSPT, 24V AC,
two wires, 1-10 bar

G500 PSM 80 1 G

(1) For G75-A3P Latch


(2) For Latch only

* To order valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 79
A U T O M A T I O N & C O N T R O L
CONTROLLERS & SPECIAL
VALVES
OCTOPUS Automatic Filter, Filter Backwash ................................................................................... 82
ii.ri-C Smart Irrigation Controller 2 Way ................................................................................. 84
ii.ri-C-VSA Smart Irrigation Controller 3 Way ................................................................................. 86
GEM-FLOW™ | G75-C Irrigation Controller | 1, 2 & 4 Valves ............................................................................ 88
GEM-FLOW™ | G75-C-1W & 1W+ Irrigation Window Controller ........................................................................................... 90
GEM-FLOW™ | G75-DP Baccara Differential Pressure Gauge Switch .......................................................... 92
GEM-FLOW™ | G75-DFC-DC Baccara Filtration Controller Set (DFC) ..................................................................... 93
GEM-FLOW™ | G75-BWM Baccara Water Meter Controller .................................................................................... 94
GEM-FLOW™ | G75-DLS Digital Level Switch ............................................................................................................. 95
GEM-FLOW™ | G75-ADP Baccara Analog Differential Pressure Sensor .......................................................... 96
GEM-SOL® | GEM-LDO Long Distance Operator 2 Way, 3 Way NC, NO ....................................................... 97
GEM-SOL | LDOS
®
Long Distance Operating Solenoid ............................................................................... 98
GEM-FLOW™ | G75-LDO Long Distance Operator 2 Way, 3 Way NC, NO ....................................................... 99

Tackling climate
change together
CONTROLLERS & SPECIAL VALVES

OCTOPUS
Filter Backwash Controller

• Filtration backwash controller 1+3 or 1+10 stations


• Mobile app in various languages
• Wireless operated by smartphone
• Main valve output is included
• Backwash by DP, Time interval or Manual
• Upstream & Downstream pressure sensors

Technical Data
Communication protocol Wireless BLE Cable gland:
Cable
solenoid,
gland:
PSU,
solenoid,
DryPSU,
contact
PSU, Dry contact
Cable gland: solenoid, Dry contact
App Downloading UpStream (8mm)
UpStream
UpStream (8mm)
(8mm)
DownStream DownStream
(8mm)
DownStream (8mm)(8mm)
• Operating temperature: -10ºC to 60ºC
• Outdoor UV protection
Mechanical
• “H” proof pressure: 10 bar (145 PSI)
• “H” pressure must be ≥ “L” pressure
• DC units are powered by 8 x C type alkaline
Electrical
batteries or 12V DC
• Pressure ports 8mm

5
5
• High pressure port is marked by the letter “H”
Mounting on the housing
• Wall mounting with four ø3.5 plastic-screws or
the two M5 (low profile) self-tapping screws

Differential pressure up to 10 bars

Time interval

Manual operation
Features
189

189


Alarm and backwash output for
189

Cable gland: solenoid, PSU,with


communication Dryirrigation
contact controller
• Data logger UpStream (8mm)
• Mounting bracket measurements upon
Options DownStream (8mm)
request
Standard protection class • IP65 | Dust and watertight
G75-A 12 OHM, G75-A3P-4 OHM, G75-P-12 OHM,
Solenoid
GEM-A3P-IL 2 wires only

140 140 140 98 98 98

How to Order
5

3.1
Example: G75-Octopus-10 plastic screws
G75-Octopus - TYPE Octopus, 10 stations + 1 Main valve

1+3 stations 03 50.35


G75-Octopus 10
5.30
1+10 stations 10 M5 (low profile) /
self tapping screws
189

88
90

59

140 98

IOM OCTOPUS

* To order controllers manufactured according to your specific requirements, please contact our technical sales department

82 A U T O M A T I O N & C O N T R O L
AGRICULTURE

OCTOPUS | Filter Backwash Controller

The App
Available in 9 languages:
English | Arabic | French | German | Hebrew | Portuguese | Spanish | Turkish | Italian

Device manager Home screen Settings

Activity log Alarm log

Tackling climate
change together 83
CONTROLLERS & SPECIAL VALVES

ii.ri-C
Smart Irrigation Controller 2 Way

• Single station Irrigation Controller


• Wireless operated by smart device
• Four irrigation program types
• Minimum required iOS 7 or Android V4.3
• Battery included

Technical Data
Function 2 Way Latch
Pressure range 0 to 8 bar
Fluid: 5º to 50ºC (no freezing)
Temperature range
Ambient: -5º to 50ºC
Communication protocol Wireless BLE

App Downloading

Pairing code Not required


Communication range Up to 10 m (32.8 feet)
Battery type CR123
Mounting Direct mounting on UNEF 3/4"
• CE
• Federal Communications Commission (FCC)
Standard / Certification • EN55011 Group1 – Class A / EN61000-6-1/
CFR 47 FCC Class A
97

EMC- SII Certificate of Conformity


Standard protection class • Dust and watertight IP68
8.4

3/4” UNEF
68

68

84 A U T O M A T I O N & C O N T R O L
AGRICULTURE

ii.ri-C | Smart Irrigation Controller 2 Way

Programming Key Features


Four different irrigation plans
Weekly Interval Days Even / Odd Days Window
Irrigation each day of Periodical days up to Even / odd calendar Repeated cycles within
the week 98 periods dates a defined time frame
Set cycle On and Off
Set up to 6 cycles per day
duration
Set start and end times
Option to set different irrigation durations per cycle
for irrigation

How to Order
ii.ri-C - PORT - FLOW CONTROL - COLOR

None Null with 5 Grey CLOUD


3/4" BSPT 50 without (1) 6
3/4" NPT 51
1" BSPT 60
1" NPT 61
1-1/2" BSPT 70
1-1/2 NPT 71
2" BSPT 80
2" NPT 81

Example: ii.ri-C-51-6-CLOUD
ii.ri smart irrigation controller with 3/4" NPT valve, without flow control, color CLOUD

ii.ri-C 51 6 CLOUD

(1) For 3/4" and 1" valves only

* To order controllers manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 85
CONTROLLERS & SPECIAL VALVES

ii.ri-C-VSA
Smart Irrigation Controller 3 Way

• • Single station Irrigation Controller


• • Wireless operated by smart device
• • Four irrigation program types
• • Minimum required iOS 7 or Android V4.3
• • Battery included

Technical Data
Function 3 Way Latch
Pressure range 0 to 8 bar
Fluid: 5º to 50ºC (no freezing)
Temperature range
Ambient: -5º to 50ºC
Communication protocol Wireless BLE

App Downloading

Pairing code Not required


Communication range Up to 10 m (32.8 feet)
Battery type CR123
Mounting Direct mounting on UNEF 3/4"
• CE
• Federal Communications Commission (FCC)
Standard / Certification • EN55011 Group1 – Class A / EN61000-6-1/
CFR 47 FCC Class A
EMC- SII Certificate of Conformity
Standard protection class • Dust and watertight IP68
COM 1

Programming Key Features (1)

Four different irrigation plans (3)

Weekly Interval Days Even / Odd Days Window


Irrigation each Periodical days Even / odd Repeated cycles within a
day of the week up to 98 periods calendar dates defined time frame COM 2

Set up to 6 cycles per day Set cycle On and Off duration


PORT NO NC
Set start and end times for
Option to set different irrigation durations per cycle 1 Exhaust Pressure
irrigation
3 Pressure Exhaust
COM Out Out

86 A U T O M A T I O N & C O N T R O L
AGRICULTURE

ii.ri-C-VSA | Smart Irrigation Controller 3 Way

Dimensions

Manual Override Operation

NO NC

OPEN OPEN

CLOSE CLOSE

AUTO AUTO

How to Order
ii.ri-C-VSA - BODY PORT FUNCTION SEALS

Plastic 4 1/8" BSP 10 3W NC 3 EPDM E


1/8" NPT 11 3W NO 4

Example: ii.ri-C-VSA-4103E
ii.ri smart irrigation controller with 1/8" BSP valve, 3W NC, EPDM seals

ii.ri-C-VSA 4 10 3 E

* To order controllers manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 87
CONTROLLERS & SPECIAL VALVES

GEM-FLOW™ | G75-C
Irrigation Controller | 1, 2 & 4 Valves

Technical Data
Operating temperature -10º to 60ºC
Various mounting options:
• Directly on a 28mm diameter solenoid in
Mounting horizontal or vertical position with adaptor
• Wall mounting with four screws
• Accessories provided
Powered by single 9V alkaline battery; use
best quality to ensure at least one year's
autonomous operation.
Electrical • Back-up memory
• Low battery warning
• Power saving LCD
• Battery included
Solenoid Compatible with G75 4Ω latch operator G75 One G75 Two G75 Four
Can operate any valve equipped with 3/4" Valve Valves Valves
Valve
UNEF solenoid cavity (Richdel® type)
• 24 hours real time clock
Software
• See 'Programming key features' table
• Solar panel
Options • Charger
• Accurate clock (low time drift)
Standard / Certification CE
• Dust and watertight
Standard protection class
• IP67 and NEMA 4X Size A B C
3/4" 145 110 81
1" 153 110 81

Mounting Options 1-1/2"


2"
166
166
160
170
127
127

B C

Wall
mounting
A

Horizontal
mounting

88 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G75-C | Irrigation Controller | 1, 2 & 4 Valves

Programming Key Features


One Valve Two Valves Four Valves

Once daily, at the same time Up to three starts per day Up to three starts per day

Once daily on selected days Starts select Starts select

Three starts per day Day select Day select

OFF Season adjustment 10% - 200% Season adjustment 10% - 200%

OFF OFF
Master valve will be opened for
each command

How to Order * G75-A


TYPE OF MANUAL
G75-C - - VALVE 1 (1)
TYPE PORT FUNCTION ORIFICE
CONTROLLER (1)
OVERRIDE
One valve 1 No valve 00 with flange 1 1/8" BSP 10 2W NC 1 None 0 1.0 (2) 1
Two valves 2 1/2” BSP 40 Brass 3 1/8" NPT 11 3W NC 3 1.2 2
Four valves 4 1/2” NPT 41 1/4" BSP (2) 20 3W NO 4 1.6 3
3/4” BSP 50 1/4" NPT (2)
21
3/4” NPT 51
1” BSP 60
1” NPT 61
1-1/2”BSP 70
1-1/2”NPT 71
2” BSP 80
2” NPT 81

G75-A *

1) Example: G75-C-160
GEVA 75 One Valve controller, 1” BSP

G75-C 1 60

(1) Only for One valve controller type. Choose “00” for Two and Four valve controller types
(2) Brass only

* To order controllers manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 89
CONTROLLERS & SPECIAL VALVES

GEM-FLOW™ | G75-C-1W & 1W+


Irrigation Window Controller

Technical Data
Operating temperature -10º to 60ºC
Various mounting options:
• Directly on a 28mm diameter solenoid in
Mounting horizontal or vertical position with adaptor
• Wall mounting with four screws
• Accessories provided
Powered by single 9V alkaline battery; use
best quality to ensure at least one year's
autonomous operation. G75 Window +
Electrical • Back-up memory
• Low battery warning
• Power saving LCD
• Battery included
Both Window and Window+ controllers have
identical programming.
• Window: compatible with G75 4Ω latch
Solenoid operator
• Window+: has a stronger output to
operate G80 latch and GEM-SOL® 'IL'
latch coils
• Window: can operate any valve equipped
with 3/4" UNEF solenoid cavity (Richdel®
Valve Irrigation cycles within a defined time frame
type)
• Window+: only with Baccara latch valve
• 24 hours real time clock
Software
• See 'Programming key features' table
• Solar panel 66 71

Options • Charger
• Accurate clock (low time drift)
Standard / Certification CE
• Dust and watertight
Standard protection class
• IP67 and NEMA 4X
106

Mounting Options
21
39

Wall
mounting

Horizontal
mounting

90 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G75-C-1W & 1W+ | Irrigation Window Controller

Programming Key Features


Set start and end hours

Set On time (1 second to 12 hours)

Set Off time (1 min to 12 hours)

Day select

OFF

How to Order: G75 Window * G75-A


MANUAL
G75-C-1W - VALVE TYPE PORT FUNCTION
OVERRIDE
ORIFICE

No valve 00 with flange 1 1/8" BSP 10 2W NC 1 None 0 1.0 (1)


1
1/2" BSP 40 Brass 3 1/8" NPT 11 3W NC 3 1.2 2
1/2" NPT 41 1/4" BSP (1) 20 3W NO 4 1.6 3
3/4" BSP 50 1/4" NPT (1)
21
3/4" NPT 51
1" BSP 60
1" NPT 61
1-1/2"BSP 70
1-1/2"NPT 71
2" BSP 80
2" NPT 81

G75-A *
* This controller will only operate with G75 operators

Example: G75-C-1W-50
GEVA 75 Window controller with 3/4" BSP valve.

G75-C 1W 50

(1) Brass only

How to Order: G75 Window+


G75-C-1W+ - VALVE

Refer to How to Order section


of GEM-SOL® valves.
Consult with us to discuss your
specific requirements.

Example: G75-C-1W+-GEM-A-21045N0
GEVA 75 Window+ controller with: GEM-A valve, brass, 1/8" BSP, 3W NO,
2.4 orifice, NBR, no manual override.

G75-C-1W+ GEM-A 2 10 4 5 N 0

* To order controllers manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 91
CONTROLLERS & SPECIAL VALVES

GEM-FLOW™ | G75-DP
Baccara Differential Pressure Gauge Switch

• Reads and reacts to pressure differential between two reading points


• Suitable to work with both media - air and liquid
• Main applications: filters backwash, pumps control, pressure control

Technical Data
• Operating temperature: -10ºC to 60ºC
(no freezing)
• Outdoor UV protection
Mechanical
• Front panel cover protection
• "H" proof pressure: 14 bar (203 PSI)
• "H" pressure must be ≥ "L" pressure. 89.5

1/8”BSP/NPT
• Power supply: 6-24V DC or 12-24V AC

TYPx2
• RED + BLK power supply 89.5

1/8”BSP/NPT
• GRN / WHT N.O contact

TYPx2
Electrical • Low power detect
• Dry contact (N.O) 0.5A at 24V AC
• Internal memory to retain "set-up data" at
power down.
• 2" (52mm) diameter
• 2ft (60cm) 4 wires cable "L"
89.5
• Pressure ports 1/8" BSP/NPT (male)
• High pressure port is marked by the letter "H" 1/8”BSP/NPT
Mounting TYPx2
on the housing
• Connect high pressure before low pressure
Ø 57.7
Ø 60
41

43
• Disconnect low pressure before high
pressure
Ø 57.7
Ø 60
41

43
25
Software See 'Programming key features' table 8

TYPx2
. 58.8

M5
The LCD display: "H" (60
25
• DIF: measured differential pressure 8

TYPx2
.
Optional Mounting 58.8

M5
• SET: pressure differential trigger setting (60
Bracket
• ON: displayed when the switch contacts
Display
are closed
Display resolution:
Ø 57.7
Ø 60
41

43

1 PSI in the range 0 - 99 psi


0.1 bar in the range 0.0 - 7 bar
• Dust and watertight 25
Standard protection class 8
TYPx2

.
• IP66 58.8
M5

(60)

How to Order Programming Key Features


Manual operation
G75-DP - TYPE ACCESSORIES
PSI or bar display
Mounting
Stand alone 1 B
bracket Time interval between pressure measurements

Contact closed time


Example: G75-DP-1B Time interval between contact closure
Baccara Differential Pressure Gauge switch, stand
alone with mounting bracket Zero calibration

G75-DP 1 B

* To order special valves manufactured according to your specific requirements, please contact our technical sales department

92 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G75-DFC-DC
Baccara Filtration Controller Set (DFC)

• Filtration backwash controller 1-3 stations


• Main valve output is optional
• Backwash by DP or time interval
• The assembly includes controller and differential pressure sensor
• Mounting bracket optional

Technical Data
DFC controller, suitable for DC only, and one
Controller Set | Supplied with
analog sensor
• Operating temperature: -10ºC to 60ºC
• Outdoor UV protection
Mechanical
• Front panel cover protection
• "H" proof pressure: 14 bar (203 PSI)
• "H" pressure must be ≥ "L" pressure.
DC units are powered by single 9V alkaline
battery; use best
quality to ensure at least one year's autono-
Electrical mous operation.
• Back-up memory
• Low battery warning
• Power saving LCD
• Pressure ports 1/8" BSP/NPT (male)
• High pressure port is marked by the letter "H"
on the housing Programming Key Features
• Connect high pressure before low pressure
• Disconnect low pressure before high Manual operation
pressure
Valve ON time
Mounting Controller:
• Directly on a 28mm diameter solenoid in Maximum time interval between washes
horizontal or
vertical position with adaptor Valve selection
• Wall mounting with four screws
• Accessories provided | Sensor: 2" (52 mm
diameter)
Software See 'Programming key features' table
Options Option to change default factory settings
Standard protection class • IP66 | Dust and watertight
Solenoid G75-A, GALIT Latch 4Ω, G75-A3P 1Ω

How to Order
MOUNTING
G75-DFC-DC - TYPE -
BRACKET
3 Valves 0 without 0
3 Valves + 1 Main Valve 1 with 1

Example: G75-DFC-DC-1-1
G75-DFC-DC, 3 Valves + 1 Main valve, with mounting bracket

G75-DFC-DC 1 1

* To order controllers manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 93
CONTROLLERS & SPECIAL VALVES

GEM-FLOW™ | G75-BWM
Baccara Water Meter Controller

• Single station water volume controller


• Connected to a water meter with pulse outlet
• Opens at a set time and closes when required water volume has been
reached

Technical Data
Operating temperature -10º to 60ºC
Powered by single 9V alkaline battery; use best quality to
ensure at least one year's autonomous operation.
• Back-up memory
Electrical
• Low battery warning
• Power saving LCD
• Battery included
Various mounting options:
• Directly on a 28mm diameter solenoid in horizontal or 66 71
Mounting vertical position with adaptor
• Wall mounting with four screws
• Accessories provided
Solenoid Compatible with G75 4Ω latch operator
Measurement units per pulse 100 liters | 1m3 | 10m3 | 100 gallons | 1000 gallons

106
• 24 hours real time clock
Software
• See 'Programming key features' table 66 71

Options Solar panel, charger


• Dust and watertight
Standard protection class
• IP67 and NEMA 4X
21
39

How to Order
106

MANUAL
G75-BWM - VALVE TYPE PORT FUNCTION ORIFICE
OVERRIDE
No valve 00 with flange 1 1/8" BSP 10 2W NC 1 None 0 1.0 (1) 1 21
1/2” BSP 40 Brass 3 1/8" NPT 11 3W NC 3 1.2 2 39

1/2” NPT 41 1/4" BSP (1) 20 3W NO 4 1.6 3


3/4” BSP 50 1/4" NPT (1)
21
3/4” NPT 51
1" BSP
1" NPT
60
61
Programming Key Features
1-1/2"BSP 70 Set start time
1-1/2"NPT 71
Set required water volume
2" BSP 80
2" NPT 81 Day select
G75-A *
OFF
* G75-A

Example: G75-BWM-G75-A-110102
G75-A with flange, 1/8" BSP, 2W NC, no manual override, 1.2 orifice

G75-BWM G75-A 1 10 1 0 2

(1) Brass only

* To order controllers manufactured according to your specific requirements, please contact our technical sales department

94 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G75-DLS
Digital Level Switch

• Measuring level of two set points: top and bottom


• Gives a signal to pump or valve
• Dry installation - no elements inside the tank
• Main applications: filling or draining of water reservoir and tanks

Technical Data
• Operating temperature: -10ºC to 60ºC
(no freezing)
Mechanical
• Outdoor UV protection
• Front panel cover protection
89.5
• Power supply: 6-24V DC or 12-24V AC

1/8”BSP/NPT
• RED + BLK power supply

TYPx2
• GRN / WHT N.O contact 89.5

1/8”BSP/NPT
Electrical • Low power detect

TYPx2
• Dry contact (N.O) 0.5A at 24V AC
• Internal memory to retain "set-up data" at
power down.
• 2" (52mm) diameter
• 2ft (60cm) 4 wires cable "L"

• Pressure ports 1/8" BSP/NPT (male)


89.5
1/8”BSP/NPT

Mounting
• High pressure port is marked by the letter "H"
TYPx2

on the housing
• Connect the water tank to the "H" port only

Ø 57.7
Ø 60
41

43
Software See 'Programming key features' table
• The LCD display shows the water level above
Ø 57.7
Ø 60
41

43
25
8

TYPx2
the DLS mounting place . 58.8

M5
• "ON" is displayed when the switch contacts are "H" (60)

25
Display closed Optional
8
Mounting

TYPx2
. 58.8

M5
Display resolution: Bracket (60)

• 10 cm in a range of 0.0 - 70.0m


• 0.01 bar in the range 0.0 - 7 bar
• Dust and watertight
Ø 57.7
Ø 60

Standard protection class


41

43

• IP66

25
8
TYPx2

How to Order
. 58.8
M5

(60)

G75-DLS - TYPE ACCESSORIES Programming Key Features


Mounting Manual operation
Stand alone 1 B
bracket
Time interval between level measurements function
Function: "SET" for fill
Example: G75-DLS-1B "RESET" for empty
Digital Level switch, stand alone, with mounting bracket
Zero calibration

G75-DLS 1 B

* To order special valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 95
CONTROLLERS & SPECIAL VALVES

GEM-FLOW™ | G75-ADP
Baccara Analog Differential Pressure Sensor

• Differential pressure to current transducer


• Suitable to work with both media - air and liquid
• Main application: analog sensor for filters backwash

Technical Data
• Operating temperature: -10ºC to 60ºC
(no freezing)
• Outdoor UV protection
Mechanical
• Measuring pressure range: 0-7 bar (0-101.5 PSI)
• "H" proof pressure: 14 bar (203 PSI)
• "H" pressure must be ≥ "L" pressure
65.7
• Power supply: 5V DC
• RED: (+) 5V

1/8” BSP
• BLACK: (-)5V

TYPx2
Electrical • ORANGE: analog output
• Analog output value:
0.2V to 4.7V, [V out = (0.006429xKpa+0.2)± Error]
• Ouput accuracy: 2.5% of full scale
• 2" (52mm) diameter
• 2ft (60cm) 3 wires cable
• Pressure ports 1/8" BSP/NPT (male) “L”
70
Mounting • High pressure port is marked
65.7 by the letter "H" A

on the housing
• Connect high pressure before low pressure
1/8” BSP
TYPx2

41

• Disconnect low pressure before high pressure Ø 60

Standard protection class • IP66

TYPx2
A
“H”

M5
How to Order
.8
25 45

Optional
Mounting Bracket
“L” MOUNTING
G75-ADP - TYPE
BRACKET A
70
R 35 1.5

Stand alone 1 without 0


Ø 52 ±0.1

with 1
41

Ø 60

Ø 6.5 ±0.1
66

TYP x2
10
TYPx2

A
“H”
M5

.8
25 45

Example: G75-ADP-10
Baccara Analog Differential Pressure sensor,
stand alone, without mounting bracket

G75-ADP - 1 0

* To order controllers manufactured according to your specific requirements, please contact our technical sales department

96 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-SOL® | GEM-LDO
Long Distance Operator 2 Way, 3 Way NC, NO

Technical Data
Function 2 Way, 3 Way NC, NO
Current Holding 4mA
Refer to working pressure definitions of the
Pressure range valve that the GEM-LDO is assembled on,
with DC10W/AC8W
• DC12V (0.05W) up to DC24V (0.1W)
Power
• 24V AC: 0.3W
Red/Black - power supply | Green/Black - coil
Connection Lead wire length - 28cm
PVC coated AWG 18 UL 1007
Ambient temp -10ºC to 70ºC
Operation Only with GEM-BL-LDO coil and Baccara valve
• Cost saving wiring for remote solenoid LDO unit
operation
Applications
• Power saving and heat prevention on A small section conductor can be
continuous energized solenoid
used at a distance of up to 5 kms
Voltage Voltage and power consumption - see table
Standard protection class IP67 (LDO only)
* For recommended wire parameters, please refer to Long distance operators charts

Distance Conduit Delay Time (sec)


Voltage
(km) section (mm2) On Off
12/24 5 0.5 3 1
* Max conduit resistance 390 at nominal voltage

Voltage & Power Consumption


AC (W)
50 60 DC(W)
Hz Hz Assembled with GEM-A solenoid Assembled with GEM-S solenoid
V 0.3 0.3 0.05 0.1
12 •
24 • • •
39 91.2
• Available options

How to Order
Please refer to the "How to
GEM-LDO - VOLTAGE - Order" definitions of the
91.5
86

assembled GEM-SOL® valve.

24 VAC &
9
12-24 VDC

Example: GEM-LDO-9-GEM-A-21035N0
GEM-LDO is attached to a GEM-SOL® latch coil direct operated, brass
1/8"BSP, 3W NC, 2.4 orifice, NBR, no manual override

GEM-LDO 9 GEM-A 2 10 3 5 N 0

* To order special valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 97
CONTROLLERS & SPECIAL VALVES

GEM-SOL® | LDOS
Long Distance Operating Solenoid

Technical Data
24V AC: Inrush 210mA | Holding 18mA
Current
12V DC: Inrush 120mA | Holding 5mA
Pressure range See table
Delay time See table
Connection DIN 43650 Connecting box
Ambient temp -10ºC to 70ºC
Operation Only with a Baccara valve
• Cost saving wiring for remote solenoid
operation
Applications
• Power saving and heat prevention on
continuous energized solenoid
LDOS unit
• Voltage and power consumption - see table
Voltage A small section conductor
• +10% -10% of nominal
Standard protection class IP65 with connector can be used at a distance
* For recommended wire parameters, please refer to Long distance operators charts of up to 5 kms.

Pressure (bar)
Function Orifice (mm) Pressure
1.6 16
3 Way NC 2.0 10
2.4 8
1.6 16
3 Way NO 2.0 12
2.4 8

Delay time (sec) at Distance Conduit Section Assembled with GEM-S solenoid Assembled with GEM-A solenoid
a nominal voltage (Km) (mm)
2.4 0.5
2xM5X0.8
4-5 4.8 1.0 DEEP 8
22
7.5 1.5

Voltage & Power Consumption


22

AC (W) 68
DC (W)
50 Hz 60 Hz 90.8

V
12 •
24 • •
• Available options
82

How to Order
27

32

Please refer to the "How to Order" definitions


LDOS - VOLTAGE - of the assembled GEM-SOL® valve

24V AC 1
12V DC 2

Example: LDOS-1-GEM-A-21035N0
LDOS 24V AC is attached to a GEM-SOL® latch coil direct operated, brass, 1/8"BSP, 3W NC, 2.4 orifice, NBR, no manual override

LDOS 1 GEM-A 2 10 3 5 N 0

* To order special valves manufactured according to your specific requirements, please contact our technical sales department

98 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G75-LDO
Long Distance Operator 2 Way, 3 Way NC, NO

Technical Data
Function 2 Way, 3 Way NC, NO
Current Holding 4mA
Pressure range Refer to G75 Latch operator
Power DC12V (0.05W) up to DC24V (0.1W)
Connection Red/Black - power supply | Green/Black - coil
Ambient temp -10ºC to 60ºC
Solenoid Compatible with G75 4Ω latch operator
Can operate any valve equipped with 3/4"
Valve
UNEF solenoid cavity (Richdel® type).
• Cost saving wiring for remote solenoid
operation LDO unit assembled with G75-A
Applications
• Power saving and heat prevention on operator and solenoid
continuous energized solenoid
Voltage Voltage and power consumption - see table
A small section conductor can be
used at a distance of up to 5 kms
Standard protection class IP67 (LDO only)
* For recommended wire parameters, please refer to Long distance operators charts

79
Conduit Delay time (sec)
Distance
Voltage section
(km) On Off
(mm2)
12/24 5 0.5 3 1

83
* Max conduit resistance 390Ω at nominal voltage
50.5 38.5

How to Order

94
63.2

Please refer to the "How to


G75-LDO - VOLTAGE - Order" definitions of the
assembled G75 valve.

24 VAC & 2 Way 3 Wa


9
12-24 VDC

79 87
83

50

50.5 38.5

Example: G75-LDO-9-G75-A-11032B-1
94

G75-LDO 24V AC is attached to a G75-A with flange, 1/8" BSP, 3W NC


63.2

1.2 orifice, no manual override, 4Ω latch coil, two wires

G75-LDO 9 G75-A 1 10 3 2 B 1 2 Way 3 Way

* To order special valves manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 99
A U T O M A T I O N & C O N T R O L
OPERATORS & COILS

GEM-B | Coil ....................................................................................................................................................... 102

GEM-BL | Latch coil ....................................................................................................................................................... 104

GEM-BP | IP68 coil ....................................................................................................................................................... 106

GEM-FLOW™ | G75-O AC/DC Operator 2 Way, 3 Way NC, NO........................................................................ 108


GEM-FLOW™ | G75-O Latch Operator 2 Way, 3 Way NC, NO .......................................................................... 110

Tackling climate
change together
OPERATORS & COILS

GEM-B | Coil

Technical Data
Coil winding insulation H 180ºC
Temperature range Coil: -20ºC to 150ºC | Ambient: -20ºC to 70ºC
Duty cycle * 100% ED
• AMP pins, DIN 46242, 2 poles + 1 earth
Electrical connection • 2 flying leads, 18 AWG (0.75mm2),
330 mm length
• DIN 43650
• PG9 or 1/2" NPT
Connector
* Max. tightening torque for the connector
screw: 0.5 Nm DIN Connector
Assembly In any position
Coil fixing One nut G1/4" hexagonal 19mm
Flying Leads
Impregnation Optional
• Voltage and power consumption - see table
Coil voltage
• All Baccara coil voltages are ±10% of nominal
Standard / Certification CE
IP65 with connector
Standard protection class
* Option: IP68 (please refer to GEM-BP coil)
• The coil should not be energized without being assembled on the operator
* Please consult with our technical sales department:
• for further information on using different power coils (not shown in the table)
• for long term operation LED Connector

Power Consumption (AC)


Type Inrush Holding
8W 26VA-13W 16VA-8W
5.5W 16VA-8W 12VA
2.5W 2.5W 2.5W

Power Consumption (DC)


Type
10W
5.5W
2.5W

Voltage & Power Consumption


AC (W)
DC (W)
50 Hz 60 Hz
V 8 5.5 2.5 8 5.5 2.5 10 5.5 3.5
6 • • •
12 • • • • •
24 • • • • • • • •
48 • • •
110 • • • •
120 • •
220 • • • • •
230 • • • •
240 • • •
• Available options

102 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-B | Coil

Dimensions

330

How to Order
GEM-B - VOLTAGE POWER CONNECTOR

AC8W
6 1 1 without 0
50Hz
AC8W
12 2 2 with 1
60Hz
24 3 DC10W 3 with LED 2
AC5.5W
48 4 4 with bi- color LED 3
50Hz
AC5.5W
110 5 5 flying leads coil 4
60Hz
AC2.5W
120 6 6 with 1/2" hub 5
50/60Hz
surge protection
220 7A DC5.5W 7 6
with LED
connector
230 7 DC3.5W 8 with moulded 7
cable
240 8 other 9

Latch/other (1) 9

Example: GEM-B-341
GEM-SOL® Coil 24V AC 5.5W 50Hz with connector

GEM-B 3 4 1

(1) For specifying Latch type coil, please refer to GEM-A3P valve - How to Order table

* To order coils manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 103
OPERATORS & COILS

GEM-BL | Latch coil

Technical Data
Coil winding insulation H 180ºC
Temperature range Coil: -20ºC to 150ºC | Ambient: -20ºC to 70ºC
• AMP pins, DIN 46242, 2 poles + 1 earth
Electrical connection • 2 flying leads, 18 AWG (0.75mm2),
330 mm length
• DIN 43650
• PG9 or 1/2" NPT
Connector
* Max. tightening torque for the connector
screw: 0.5 Nm
Assembly In any position
Coil fixing One nut G1/4" hexagonal 19mm
Typical pulse time 30~50ms
Impregnation Optional
Standard / Certification CE
IP65 with connector
Standard protection class
* Option: IP68 (please refer to GEM-BP coil)
• The coil should not be energized without being assembled on the operator
• The coil, including its magnetic circuit and permanent magnets, is encapsulated in high
temperature resistant nylon to withstand humidity and meet heavy duty requirements.

When ordering for a new application, please inform us of your requirements


according to the table below. This will enable us to determine the most
suitable coil.

MAX SWITCHING
OPERATING CAPACITOR
VOLTAGE CURRENT [A] TIME
METHOD [µ F]
ON COIL [ms]

3 Direct ≤2 None ≤25


6 Capacitor ≤1 2200 ≤50
9 ≤0.5 4700 ≤100
12 ≤0.1 other other
24 other
230
Other

Example: 12V DC, Capacitor, ≤1, 4700, ≤50ms

12V Capacitor ≤1 4700 ≤50ms

104 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-BL | Latch coil

GEM-SOL with
Flying Leads

Dimensions

9 G E M- B- 3 1
2 4 V 5 0 H z8 W

330

How to Order
GEM-BL - LATCH TYPE (1) CONNECTOR

2Ω LDO without 0

5Ω IL with 1

flying leads
13Ω EL 4
coil
with 1/2"
20Ω OL 5
Hub
connector
53Ω DL with moulded 7
cable
other 9

Example: GEM-BL-LDO1
GEM-SOL® latch coil, 2Ω latch with connector

GEM-BL LDO 1

(1) Choose latch type according to which latch system you have

* To order coils manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 105
OPERATORS & COILS

GEM-BP | IP68 coil

Technical Data
Construction Housing: encapsulated polyurethane
Coil winding insulation H 180ºC
Temperature range Ambient: -5ºC to 50ºC (no icing)
Duty cycle 100% ED
IP68 infinite time immersion under water,
Protection
up to 2m depth
3x18 AWG (0.75mm2), hook up wire, 200cm
Electrical connection
* other lengths are available
Assembly In any position
Coil fixing One nut G1/4" hexagonal 19mm
Standard / Certification European Standards IEC 60529 code IP68
• Voltage and power consumption - see table
Coil voltage
• All Baccara coil voltages are ±10% of nominal
• The coil should not be energized without being assembled on the operator

Power Consumption (AC)


Type Inrush Holding
8W 26VA-13W 16VA-8W
5.5W 16VA-8W 12VA
2.5W 2.5W 2.5W

Power Consumption (DC)


Type
10W
5.5W
3.5W

Voltage & Power Consumption


AC (W)
DC (W)
50 Hz 60 Hz
V 8 5.5 2.5 8 5.5 2.5 10 5.5 3.5
6
12 • • • • •
24 • • • • • • • • •
48
110
120
220
230
240
• Available options

106 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-BP | IP68 coil

Dimensions Tightening torque


2.5 ± 0.5 [N-m]

38
2m conduit

62 32

How to Order
GEM-BP - VOLTAGE POWER

12 2 AC8W 50Hz 1
24 3 AC8W 60Hz 2
DC10W 3
AC5.5W 50Hz 4
AC5.5W 60Hz 5
AC2.5W
6
50/60Hz
DC5.5W 7
DC3.5W 8

Example: GEM-BP-31
IP68 GEM-SOL® coil 24V AC 8W 50Hz.

GEM-BP 3 1

* To order coils manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 107
OPERATORS & COILS

GEM-FLOW™ | G75-O
AC/DC Operator 2 Way, 3 Way NC, NO
Applicable for G75-A, Galit, G75-S & G75-Z valves

Technical Data
Function 2 Way, 3 Way NC, NO
2 Way: No orifice
Orifice size
3 Way: See table
Pressure range (bars) See solenoid valve performances
Fluid: 5ºC to 50ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
Housing:
Plastic (Reinforced Nylon 66) 2 Way Operator
Plunger & pole:
Stainless Steel AISI 430F
Materials in contact Rubber Seals:
with media EPDM
Encapsulate:
Polyurethane
Spring:
Stainless Steel AISI 300 series
Media Air, water, oil *
G1/8" or 1/8" NPT female to connect exhaust,
Threads on operator tube 3 Way Operator
muffler etc
By manually screwing 3/4" UNEF to valve body.
Operator assembly
• Max. tightening torque: 2 N/m
Lead wires 35 cm, 18 AWG (0.75mm2)
Electrical connection
* other lengths are available
Coil voltage • Voltage and power consumption - see table
Standard protection class IP66
* For other fluids and for use in abnormal conditions,
please contact our technical sales department

Working Pressure (bar) 2 Way NC


Orifice (mm) up to 2.0
Pressure (bar) 12

2 W ay N C 3 W ay N C / 3 W ay N O

Working Pressure (bar) 3 Way NC


Orifice (mm) 1.0 1.2 1.6
AC Pressure (bar) 16 11 6
DC Pressure (bar) 12 9 5

Working Pressure (bar) 3 Way NO Voltage & Power Consumption


Orifice (mm) 1.0 1.2 1.6 AC (W) DC (W)
Pressure (bar) 16 12 10 V 2 4.5
12 • •
24 • •
Voltage & Current 110 •
2 Way only
• Available options
AC & DC
Solenoid Voltage Inrush [A] Holding [A]
2 Way 50 Hz 0.3 0.19
+10%
V
2 Way 60 Hz 0.2 0.14
3 Way 50/60 Hz * n-20% 0.125 0.125
DC 4.5W
* Except 24V AC without Diode

108 A U T O M A T I O N & C O N T R O L
Ø30 BLACK WIRE

1/
CABLE LENGTH
350 (mm)
BLACK/RED

SOLENOID ON

58
AGRICULTURE

SOLENOID ON

SOLENOID ON
54

47
1.2

1.2
GEM-FLOW™ | 3/4"-UNEF-20TPI
G75-O | AC/DC Operator 2 Way, 3 Way NC, NO

1.2
9
9
3/4"-20 UNEF-2B 3/4"-20 UNEF-2B
PLUNGER STROKE 1+- 0.1 PLUNGER STROKE 1+- 0.1

Ø 24
Dimensions 3 Way NC / 3 Way NO 2 Way NC
Ø33.5

Ø30 29.8 CABLE LENGTH


350 (mm)
1/8" BSP/NPT BLACK WIRE CABLE LENGTH
1/2" NPT

350 (mm)
Ø30 BLACK WIRE
3/4" 20TPI UNEF
Ø12
CABLE LENGTH
350 (mm)

2.2 +0.1
5.5
6.5
BLACK/RED
58

10
SOLENOID ON

SOLENOID ON
47
1.2

1.2
9
9

Operator seat MaxØ2.0


3/4"-20 UNEF-2B 3/4"-20 UNEF-2B
PLUNGER STROKE 1+- 0.1 PLUNGER STROKE 1+- 0.1
Ø24

3 Way NC / 3 Way NO 2 Way NC

E LENGTH

How to Order
mm)
K WIRE

2 Way
3/4" 20TPI UNEF

G75-O - FUNCTION Ø12 VOLTAGE

2W NC 1 24V AC 1
2.2 +0.1
5.5
6.5

10

24V AC
1R
w/out Diode (1)

3 Way 12V AC 3

G75-O - PORT FUNCTION ORIFICE


12VMaxØ2.0
DC 4
Operator seat

1/8" BSP 10 3W NC 3 1.0 1


24V DC 5
1/8" NPT 11 3W NO 4 1.2 2
1.6 3
110V AC 7

Example: G75-O-1-1
G75 operator, 2W NC, 24V AC

G75-O 1 1

Example: G75-O-1032-1
G75 operator, 1/8" BSP, 3W NC, DC, 1.2 orifice, NBR, 24V AC

G75-O 10 3 2 1

(1) 3W NO 1.6 mm: Max pressure is 8 bar

* To order operators manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 109
OPERATORS & COILS

GEM-FLOW™ | G75-O
Latch Operator 2 Way, 3 Way NC, NO
Applicable for G75-A, Galit, G75-S & G75-Z valves

Technical Data
Function 2 Way, 3 Way NC, NO Latch
2 Way: No orifice
Orifice size
3 Way: See table
Pressure range (bars) See solenoid valve performances
• 4700µ F for 9V DC
Capacitors
• 2200µ F for 12V DC
Switching time 25-50 ms
2 Way Operator
Fluid: 5ºC to 50ºC (no freezing)
Temperature range
Ambient: -10ºC to 50ºC
Housing:
Plastic (Reinforced Nylon 66)
Plunger & pole:
Stainless Steel AISI 430F
Materials in contact Rubber Seals:
with media EPDM
Encapsulate:
Polyurethane
Spring: 3 Way Operator
Stainless Steel AISI 300 series
G1/8" or 1/8" NPT female to connect exhaust,
Threads on operator tube
muffler etc
One coil with exit of 2 lead wires. To pull the
Two wire operator plunger up, connect the black wire (-) and
the green to the (+).
One coil and an integrated electrical circuit.
To pull plunger up, pulse is given to the
Three wire operator red wire (-). To release the plunger, pulse is
given to the black wire (-).
Operate only by a controller.
• Lead wires 35 cm, 18 AWG (0.75mm2)
Electrical connection (black/green)
• Lead wires: red, white, black for 3 wires
Voltage 9, 12V DC (coils for other voltages available)
Standard protection class IP66
2 Way NC 3 Way NC / 3 Way NO

Working Pressure (bar) 2 Way NC


Orifice (mm) up to 2.0
Pressure (bar) 12

Working Pressure (bar) 3 Way NC


Orifice (mm) 1.0 1.2 1.6
AC Pressure (bar) 16 11 6

Working Pressure (bar) 3 Way NO


Orifice (mm) 1.0 1.2 1.6
Pressure (bar) 16 12 10

110 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-FLOW™ | G75-O | Latch Operator 2 Way, 3 Way NC, NO

Dimensions Ø30

1/8" BSP/NPT

CABLE LENGTH
350 (mm)
BLACK/GREEN
58

47
SOLENOID ON
1.2
9

3/4"-20 UNEF-2B
PLUNGER STROKE 1± 0.1

3 Way NC / 3 Way NO 2 Way NC

How to Order
3/4" 20TPI UNEF
2 Way Ø12
VOLTAGE
G75-O - FUNCTION
VDC (1)
WIRES

2.2+0.1
5.5
6.5

2W NC 1 4Ω B two null

10
3 Way 9Ω C three a

G75-O - PORT FUNCTION ORIFICE 12Ω D

23Ω 6
1/8" BSP 10 3W NC 3 1.0 1
Operator seat MaxØ2.0
1/8" NPT 11 3W NO 4 1.2 2
1.6 3

Latch Coil Resistance vs Input Voltage


Recommendations chart
Resistance [Ω] Input voltage range [V]
4 6-9
9 12 - 14
12 14 - 16
23 18 - 21

Example: G75-O-1-Ba
G75 latch solenoid operator, 2W NC, 4Ω, 2 wires

G75-O 1 B a

Example: G75-O-1042-Ca
G75 latch solenoid operator, 1/8" BSP, 3W NO, 1.2 orifice, 9Ω, 3 wires

G75-O 10 4 2 C a
(1) Refer to Latch Coil Resistance vs Input Voltage | Recommendations chart

* To order operators manufactured according to your specific requirements, please contact our technical sales department

Tackling climate
change together 111
A U T O M A T I O N & C O N T R O L
TECHNICAL INFORMATION

Valve Functions ....................................................................................................................................................... 114

Operating Mechanism ....................................................................................................................................................... 115

Valve Sizing ....................................................................................................................................................... 116

GEM-SOL® Elastomer Materials ....................................................................................................................................................... 117


Flow Chart for Liquids ....................................................................................................................................................... 118

Flow Chart For Gases ....................................................................................................................................................... 119

Operation Driver for Latch Coils ....................................................................................................................................................... 120


Conduits Sizing ....................................................................................................................................................... 121

Long Distance Operators Charts ....................................................................................................................................................... 122

Tackling climate
change together
TECHNICAL INFORMATION

Valve Functions
Two way valves have one orifice and two ports: one inlet and one outlet. They are available with the following
functions:
• Normally Closed (NC) Fig. 1 - valve is closed for flow through the valve when the coil is de-energized.
• Normally Open (NO) Fig. 2 - valve is open for flow through the valve when the coil is de-energized.

OUT

IN OUT IN

de-energized energized de-energized energized


Fig. 1 Fig. 2

Three way valves have two orifice and three ports: inlet, outlet and exhaust. They are available with the following
functions:
• Normally Closed (NC) Fig. 3 - no flow from inlet port, flow is from outlet port to the exhaust.
• Normally Open (NO) Fig. 4 - flow from inlet port, no flow from the exhaust port.

EX
IN

OUT IN OUT EX

de-energized energized de-energized energized


Fig. 3 Fig. 4

Also available are the following non-standard functions: Divertor Fig. 5 - one inlet pressure with two outlets, one outlet
is NO and the other NC. Selector Fig. 6 - two inlet pressures, one inlet is NO and the other NC.

OUT 1 IN 1

IN OUT 2 OUT IN 2

de-energized energized de-energized energized


Fig. 5 Fig. 6

114 A U T O M A T I O N & C O N T R O L
AGRICULTURE

Operating Mechanism
A solenoid valve is a combination of two functional units:
• A solenoid (electromagnet) with a moving core (plunger).
• A valve body containing the right orifices and seals mechanism.
The plunger in a solenoid valve moves and changes the flow direction when a current is supplied to the electromagnet.

There are two basic types of Baccara GEM-SOL® valves:

Direct operated solenoid valves


When the solenoid is energized in a direct acting valve, the plunger moves and directly acts on the valve disc to open,
close or change the flow direction. Direct acting valves' performance depends directly on the orifice pressure and the
magnetic power. The increase of line pressure or the orifice size requires more power from the electromagnet.

Pilot operated solenoid valves


These valves are recommended for applications where high flow at high pressure is required. A pilot chamber is used
which is controlled by a direct acting solenoid valve. The movement of the plunger changes the pressure in the pilot
chamber.
When there is pressure in the pilot chamber the valve is closed. GEM-SOL® pilot valves are equipped with diaphragm,
according to the valve function.
• Two way valves have a bleeding passage in the diaphragm, through which the pilot pressure flows into the pilot
chamber; and one orifice to release the pressure when the solenoid is energized.
• Three way valves have a three way pilot solenoid to control the pilot chamber pressure.
• Pilot operated valves require a minimum operating pressure.

Zero differential valves


We also manufacture a two way pilot operated valve which works without differential pressure. For this type of valve,
a mechanical spring helps to lift the diaphragm.

Two way Three way Zero differential

Diaphragm

IN OUT

de-energized
de-energized
EX

Bleeding orifice

IN OUT

energized
energized
EX

Tackling climate
change together 115
TECHNICAL INFORMATION

Valve Sizing
General Viscosity
It is not recommended to select a solenoid valve according to Practically, the flow Kv is identical for a valve crossed by water
its pipe connection port or its orifice size. The valve selection or a medium having up to 3ºE viscosity. The flow/pressure
depends on the knowledge of the following factors: characteristic is effected above this limit. It is necessary to
pressure range minimum and maximum, differential pressure, consider factor above 3ºE - the flow factor Kv will be:
minimum and maximum flow rate, the specific gravity of the
fluid, temperature, viscosity, etc.
Pressure
The pressure is generally measured above the atmospheric
pressure and is expressed in kg/cm2 or bars of relative
δ = kinematic viscosity (in centistrokes) of the fluid
pressure.
Q = flow in liter/min
The value of pressure terms in this catalog corresponds to the
Kv = flow factor given in catalog
relative pressure.
Pressure drop ∆P This calculation leads to a choice of a valve with a higher flow
This is the difference of pressure between the upstream P1 and factor value than the one which would have been chosen for a
the downstream P2 of the valve when it is crossed by the fluid. fluid having a viscosity of 3ºE.
Differential pressure Temperature
Minimum - maximum The limits of temperature of use of a solenoid valve depend
This is the minimum or maximum difference of pressure essentially upon the nature of the discs and the desgn of the
between the upstream P1 and the downstream P2 which coil. The temperature developed in a solenoid valve is a function
secures perfect functioning of the device. Only a pilot operated of the electrical characteristics of the coil, the duty cycle, the
solenoid valve requires the minimum differential pressure to fluid and ambient temperatures. These parameters determine
operate. the “temperature of use”.
For each type of solenoid valve, the temperature range is given
Flow - the flow factor Kv (Cv) in the technical data, however these figures are only a general
The flow of a solenoid valve is the quantity of fluid per time guide. If temperature of use might extend the given limits,
units crossing the valve under certain conditions. It is this please contact our technical sales department.
factor which determines its size. To obtain a simpler method
of calculation and comparison between the various types of Response time
valves, all variables permitting the calculation of the flow have The response time of a solenoid valve is the lapse of time
been reduced to a common denominator: the flow factor Kv between the electric signal and the outlet of fluid signal. The
(without units). The Kv factor can be determined by the flow response time is effected by the following parameters:
chart or by calculation. When the Kv factor is determined, select Valve function, operating mode, orifice size, inlet pressure and
the solenoid valve which has the equivalent flow factor. The flow pressure differential, fluid, temperature and coil characteristics.
factor values given in this catalog have been set up according The C.E.T.O.P defines the test of conditions as follows:
to the following method: Test pressure: air at 6Kg/cm2 - 85 PSI
Ambient temperature: 200 C - 680 F
Response time at energizing
Response time at energizing of the solenoid and until the outlet
pressure reaches 90% of the test pressure.
Response time at de-energizing
Fluid is water, specific gravity 1 kg/dm3 the pressure drop P1, P2 Lapse of time between de-energizing of the solenoid and until
is 1Kg/cm2 in a way that the Kv is equal to the flow in liter/min. the pressure outlet drops to 10% of the test pressure, see
schemas of measure method and resulting curves for AC and
DC current.
Average response time for GEM-SOL® valves can be assumed as
follows:
When several valves are mounted in series, the resulting flow • Direct acting solenoids 16 to 36 ms for complete cycle.
factor is equal to: • Large direct acting solenoids 40 to 80 ms for complete cycle.
• Pilot operated valve 20 to 80 ms for complete cycle.

Cycling rate
The cycling rate of a solenoid depends directly on its response
When several valves are mounted in parallel, the resulting flow time. It is the number of cycles per minutes calculated for
factor is equal to: continuous operation. The valve should not be reversed at less
than 90% or above 10% at discharging of reference pressure.

The cycling rate is the maximum possible cycles per minute


of the solenoid valve. It varies when the valve is mounted in a
circuit and depends then upon the installation pressure drop.

116 A U T O M A T I O N & C O N T R O L
AGRICULTURE

GEM-SOL® Elastomer Materials


General information
GEM-SOL® solenoid valves can be used for many fluid types including acids, gases, solvents etc.
To ensure appropriate functioning of the valve, particular care must be taken with the selection
of the valve and seals materials. The information below summarizes the elastomers materials
used for GEM-SOL® valves.

Please contact our technical department for further information.

NBR or BUNA-N
• NBR is a copolymer of butadiene and acrylonitrile. It is the most used elastomer in the seals industry and is the
standard elastomer for GEM-SOL® valves.
• NBR is suitable for use from -20ºC to 85ºC. It has benefits over other elastomers with its compression set, tear and
abrasion resistance.
• Air, cold water and inert gases are some of the materials NBR is recommended for.
EPDM - Ethylene Propylene Rubber
• EPDM is an elastomer made from ethylene and propylene monomers. It has a wider temperature range than
• NBR, -40ºC to 149ºC. Its main disadvantage is that it cannot be used with petroleum oils.
• Water, alcohol and acetone are some of the materials EPDM is recommended for.
Neoprene
• Neoprene is homopolymers of chloroprene. It has a temperature range of -20ºC to 85ºC.
Neoprene is unusual because it is resistant to both oxygen and petroleum.
• •Refrigerants, oxygen and petroleum oils are some of the materials Neoprene is recommended for.
FKM
• FKM is a very important elastomer due to its wide compatibility to chemicals.
It has a temperature range of -20ºC to 180ºC. This gives FKM a significant advantage over NBR, but it is still not the
ultimate elastomer.
• Diesel oil, gasoline, some acids and trichlorethylene are some of the materials FKM is recommended for.

Tackling climate
change together 117
TECHNICAL INFORMATION

Flow Chart for Liquids

Kinematic viscosity: Max. 3º Engler


Spec. gravity Flow factor Flow rate Pressure drop
γ (Kg/dm3) Kv Q (l/min) ∆p (bar)

p γ
Q = Kv γ Kv = Q p

Q = ? Kv = ?
γ = 1 (water) γ = 1 (water)
Kv = 40 p = 4
p= 4 Q = 80
Q = 801/m Kv = 40

118 A U T O M A T I O N & C O N T R O L
AGRICULTURE

Flow Chart For Gases

Spec. gravity Flow factor Flow rate Pressure drop


γ N (Kg/m3) Kv QN (Nm3/h) ∆p (bar)

t (ºC)

Inlet pressure
p1 = (bar)

QN = ? Kv = ?
t = 25 t = 25
γN = 1.3 (air) γN = 1.3 (air)
Kv = 3 QN = 12
p1 = 5 p1 = 5
p = 1.8 p = 1.8
QN = 12 Nm3/h Kv = 3

Tackling climate
change together 119
TECHNICAL INFORMATION

Operation Driver for Latch Coils

Non-direct operation with two switches (or four transistors)

Tvc is the time to charge the capacitor. In order to reduce the time, use a similar resistor but never less than 100Ω.
C = 4700µ F
Tvc = 5 • R • C [sec]
ton/off = 30 ÷ 50 ms

Non-direct operation with one switch (or transistor)

C = 4700µ F
ton/off = 30 ÷ 50 ms

Direct operation

120 A U T O M A T I O N & C O N T R O L
AGRICULTURE

Conduits Sizing

GEM-SOL®
Wires cross-section selection for distance installation of GEM-SOL® solenoids
Solenoid type: GEM-SOL® 8W 24V AC
No. of solenoids 1 2 3 4 Distance
1.0 1.5 2.5 4.0 100m
1.5 4.0 6.0 6.0 200m
2.5 6.0 300m
4.0 6.0 400m
Cross-section 4.0 500m
[mm2] 6.0 600m
6.0 700m
6.0 800m
900m
1000m
Max. conduits resistance 4
Solenoid type: GEM-SOL® 5.5W 24V AC
No. of solenoids 1 2 3 4 Distance
0.75 1.5 2.5 2.5 100m
1.5 2.5 4.0 6.0 200m
2.5 4.0 6.0 300m
2.5 6.0 400m
Cross-section 4.0 500m
[mm2] 4.0 600m
6.0 700m
6.0 800m
6.0 900m
1000m
Max. conduits resistance 5

G75
Wires cross-section selection for distance installation of G75 solenoids
Solenoid type: G75 24V AC
No. of solenoids 1 2 3 4 Distance
0.5 0.5 0.75 1.0 100m
0.5 1.0 1.5 2.5 200m
0.75 1.5 2.5 2.5 300m
1.0 2.5 2.5 4.0 400m
Cross-section 1.5 2.5 4.0 6.0 500m
[mm2] 1.5 4.0 4.0 6.0 600m
2.5 4.0 6.0 6.0 700m
2.5 4.0 6.0 800m
2.5 4.0 6.0 900m
2.5 6.0 1000m
Max. conduits resistance 15
Solenoid type: G75 latch 4Ω
No. of solenoids 1 2 3 4 Distance
0.75 1.5 1.5 2.5 10m
1.5 2.5 4.0 6.0 20m
1.5 4.0 6.0 6.0 30m
2.5 6.0 6.0 40m
Cross-section 4.0 6.0 50m
[mm2] 4.0 60m
4.0 70m
6.0 80m
6.0 90m
6.0 100m
Max. conduits resistance 0.6

Tackling climate
change together 121
TECHNICAL INFORMATION

Long Distance Operators Charts

LDOS | Long distance operating solenoid


Number of solenoids that operate simultaneously as a function of wire cross-sectional [mm2]
area and distance [mt] from energy source
Distance in WIRE CROSS-SECTIONAL AREA [mm2]
meters from
energy source 0.50 1.00 1.50 2.50
200 12 25 38 65
400 6 12 19 40
600 4 8 12 21
800 3 6 9 16
1,000 2 5 7 13 LDOS | assembled
1,500 1 3 5 9 with GEM-S solenoid
2,000 1 2 3 6
2,500 1 2 3 5
3,000 1 2 4
3,500 1 2 4
4,000 1 2 3
5,000 1 1 2
6,000 1 2
7,000 1 1
8,000 1 1
9,000 1
10,000 1
Wire’s maximum resistance for one solenoid is 175
For further technical information, please refer to product pages in Controllers & Special section

G75-LDO | Long distance operator 2 Way, 3 Way NC, NO


GEM-LDO | Long distance operator 2 Way, 3 Way NC, NO
Number of solenoids that operate simultaneously as a function of wire cross-sectional [mm2]
area and distance [mt] from energy source
Distance in WIRE CROSS-SECTIONAL AREA [mm2]
meters from
energy source 0.50 1.00 1.50 2.50
200 24 56 78 130
400 12 28 39 65
600 8 18 26 43
800 6 14 19 32 G75-LDO | assembled
1,000 4 11 15 26 with G75-A operator
1,500 3 7 10 17 & solenoid
2,000 2 5 7 13
2,500 2 4 6 10
3,000 1 3 5 8
3,500 1 3 4 7
4,000 1 2 3 6
5,000 1 2 3 5
6,000 1 2 4
7,000 1 2 3
8,000 1 1 3
9,000 1 1 2
10,000 1 1 2
Wire’s maximum resistance for one solenoid is 390 GEM-LDO | assembled
For further technical information, please refer to product page in Controllers & Special section with GEM-A solenoid

122 A U T O M A T I O N & C O N T R O L
AGRICULTURE

Tackling climate
change together 123
BACCARA WORLD WIDE
BACCARA Corporate Headquarters Baccara Australia Pty Ltd. Baccara Automation S.L.U.
Kvutzat Geva, 1891500, 6 Jacks Road, Oakleigh South, Avenida De La Industria,
Israel Victoria 3167, 38, Nave A-15
T. +972 4 653 5960 Australia 28823 – Coslada (Madrid)
F. +972 4 653 1445 T. +61 3 9570 2130 Spain
info@baccara-geva.com www.baccara-geva.com/australia/ T. +34 91 344 6310
www.baccara-geva.com Online Store: www.baccarastore.com.au F. +34 91 344 6311
spain@baccara-geva.com
www.baccara-geva.com/es/

Baccara USA Baccara India


1312 W Stanford Ave, Empirical Business Center, Office
Englewood, CO 80110, no. 405, Navale Icon, Near Navale
USA Bridge, Off NH4, Narhe, Pune. PIN-
T. +1 720 221 3221 411041. [Maharashtra]
info.us@baccara-geva.com M. +91 91 685 27007
www.baccara-geva.com/usa/ india@baccara-geva.com
05/2022

Tackling climate
A U T O M A T I O N & C O N T R O L change together

You might also like