Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Product Type

Performance Curve BS2151.011 LT


Date Project Curve No Issue
2020-01-30 63-232-00-0410 6
1/1-Load 3/4-Load 1/2-Load Rated 30 hp Impeller Diameter
Power ... ( 22.37 kW)
Power Factor 0.94 0.93 0.90 Starting 166 mm
Efficiency 86.5 % 86.5 % 84.5 % Current ... 330 A Motor # Stator Rev
Rated
Motor Data --- --- --- Current ... 42 A 27-15-2AA 30D 13
Comments Inlet/Outlet Rated Freq. Phases Voltage Poles
ALSO VALID FOR 2151.050
Speed ... 3535 rpm
-/150 mm Tot. Mom. of 60 Hz 3 380 V 2
AND IMP. CODE 252 Imp. Throughlet Inertia ... 0.062 kgm2 Geartype Ratio
No. of
--- Blades 4 --- ---

24
[kW]
22
Power

Best Eff. Point


20

18

16

Duty-Point Flow [l/s] Head [m] Power [kW] Eff. [%] NPSHR[m]
B.E.P. * *
63.0 22.9 23.8 ( 20.6) 59.7 (68.8) 9.5

[m] Eff.

NPSHR
[%]
45

40 80

35 [m] 70
Head (H)

30 12 60

25 10 50

20 8 40
SACU (rev:8.1)

15 6 30

10 4 20
unix AUTHOR: MSILVA

5 2 10

0
Status = OLD 0
0 10 20 30 40 50 60 70 80 90 100
[l/s]
NOTE: Flow (Q)
CURVES SHOW PERFORMANCE WITH CLEAR COLD WATER
* : Pump EFFICIENCY/Shaft POWER
TESTED ACC. TO :
O : Overall EFFICIENCY/Input POWER
NPSHR = NPSH3 + min. operational margin
ISO 9906:2012 & ANSI/HI 11.6:2012

You might also like