Configuration / Function Passenger Cabin Ventilation System: Effectivity: ALL Ventilation Control
Configuration / Function Passenger Cabin Ventilation System: Effectivity: ALL Ventilation Control
Version: C2e, C2
Configuration / Function
Passenger Cabin Ventilation System
Effectivity : ALL
A. Ventilation Control
The blower (3, Figure 1) operates when the circuit breaker PAX BLW (8) is pushed
and the switch PAX BLW (7) is set to the position ON.
B. Air Distribution
The airflow from the NACA duct (1) goes through the inlet duct (2) and the blower ( 3).
Then the airflow is sent via the ducts (4) to the outlets ( 5). It is possible to move the
outlets (5) in their mounts to change the direction of the airflow or to close them. The
periscope (6) keeps water out of the NACA duct (1).