Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

TDS.

TECHNICAL DATA SHEET


TECNOFLOOR T-3020 v.22-11-2022
1/7

TECNOFLOOR T-3020 - TWO-COMPONENT EPOXY


RESIN FOR FLOORING

Two-component , colored, aromatic and fluid epoxy resin as a cotaing. Once cured, it forms a continuous
seamless high resistant to abrasion and wear coating. For flooring and coating surfaces for pedestrian and
vehicular traffic in commercial or industrial uses.

USES
For application in the following situations:

Traffic areas as garages, car-parks, or industrial floorings


In areas such as the chemical and food industries and commercial areas
As protection against liquid spills and aggressive chemicals

NOTE: call our technical department about the application to other substrates or scopes of use

Density 1,55 g/cm³


Viscosity 3.000 - 3.200 cps
Dry time 4-6 hours
Cured time ±7 days
Walkable (pedestrian/ vehicular) ±24 hours/5 days
Application method By roll, notched trowel,or squeeze

COLORS
Green RAL 6001
Grey RAL 7042
Red RAL 3016

RAL
* For special pigmentations and minimum quantities, please see page Sale conditions on the price list
TDS. TECHNICAL DATA SHEET
TECNOFLOOR T-3020 v.22-11-2022
2/7

GENERAL SPECIFICATIONS
100% solid, colored epoxy resin, with high fluidity and covering power, which once dry forms a coating with high
surface hardness, continuous, completely adhered to the substrate and with great adhesion, without joints or
overlaps and easy to clean and maintain.
Solvent-free, odorless (100% solids). Do not add water or solvent in any case
It has obtained the highest A+ classification according to the ISO 16000 standard (Air emissions) for emissions
of volatile organic compounds (VOCs).
The application must be carried out on firm, resistant supports, and in conditions of no presence of moisture in
the substrate or water from the substrate or backsplash, either at the time of application or afterward (pressure
from the water table...). In the case of existing humidity in the substrate at the time of application, consult the
technical data sheets of our primers where the ranges of resistance to humidity are specified.
The final product is made by mixing the two components delivered in the kit. In case of making applications with
partial mixture of both components, respect the mixing ratio at all times so that the final product obtains the best
product conditions.
Use the same batch of product in each area of application to avoid the minimum and possible color change
Do not use heat cannons that burn fossil fuels in case of need to increase the ambient temperature. These
conditions facilitate the appearance of white spots related to the carbonation of the material. Use in any case
electric heaters.

PACKAGING
Metallic pail kit, in two different formats:

LARGE KIT: 20,60 kg + 4,40 kg


SMALL KIT: 4,12 kg + 0,88 kg

SHELF LIFE
12 months at temperatures between 5° C and 35° C (41 ºF to 95 ºF), provided it is stored in a dry place. Once the tin
has been opened, the product must be used.

MIXING PROCEDURE
These are the steps for the correct mixing of both components:

Open pails of both components and homogenize each one by mixing equipment at medium speed
Pour component B into the container of component A
Mix using electric mixing equipment at medium speed, until a homogeneous product is obtained
In case of doubt, apply in a limited area to check

APPLICATION METHOD
The following factors prior to application should be checked:

Previous preparation of the substrate according to its type


Detail work (upsands,drains/evacuations, expansion or structural joints)
General cleaning of the substrate, removing existing dust, dirt, grease, or efflorescence

Cement or concrete substrates

The concrete must be completely cured (the curing process is 28 days), or in any case, it is necessary to check
the maximum degree of moisture permittivity of the substrate depending on the primer to be used
TDS. TECHNICAL DATA SHEET
TECNOFLOOR T-3020 v.22-11-2022
3/7

Previous preparations of the substrate through physical processes (substrate preparation (sanding, polishing,
shot blasting, or milling) for laitance and reliease agents as well as for the opening of the surface pore, achieving
a suitable anchorage profile. (CSP 3 -4-5, according to the ICRI)
Existing holes or areas with a lack of material must be repaired using some or our epoxy resins: Primer EP-
1020/Primer EP-1010
Joint fillings with Mastic PU
In existing dilatations joints: remove old material, clean, and fill with Mastic PU. Use also Tecnoband 100 to
cover, if necessary.
Joint filling for installation, work and consolidation of surfaces.
General cleaning of the substrate, removing existing dust, dirt, grease or efflorescence. The substrates must be
resistant and cohesive.
Primer application Primer PU-1050/Primer PUc-1050 of a polyurethane resin with a total yield of approximately
300 g/sqm (applied in several thin layers) or Primer WET depending on the humidity existing in the substrate and
with a total consumption of 450 g/ sqm. Consumption of primers always subject to the physical characteristics of
the substrate and its absorption coefficient.
Resin application

NOTE: For other types of supports, weather conditions or the substrate to be applied, consult our technical department.

APPLICATION TYPOLOGIES
Paint

Apply a first layer of the resin by brush, short-haired roller. Consumption approx.: 275-300 g/m²
Wait for its total drying
Apply a second coat. For the application, a brush or short-haired roller can be used. Consumption approx.: 275-
300 g/sqm
On very absorbent supports or for very light colors, it may be necessary to apply a third layer of resin.

Multilayer

This system provides a non-slip surface to give the coating a slip resistance level of >45 (Class 3).
Apply a first coat of the resin by brush, short-haired roller. Consumption approx.: 300 g/sqm
Wait for its total drying
Sprinkle the surface with aggregates (Silica Sand) until saturation.
Once hardened, the remaining aggregate must be removed by sweeping.
Lightly sand the surface and then vacuum the residues generated.
Apply a second coat of the resin by brush, short-haired roller. Consumption approx.: 300 g/sqm

Self-leveling

In this type of application is possible to mix graded clean and dry quartz sand 0,1~0,5 mm. In mixing ratio of
±1:0.7 or ±1:1 depending on the temperature and desired workability
Pour the resin on the substrate, then distributing it with a notched trowel with which you can control thickness
and consumption.
Once past 20 minutes is necessary to pass a spiked roller with which the air outlet will facilitate within the material
The performance is more or less 1,65.kg/sqm/mm (pure material), depending on the degree of roughness of the
substrate.
TDS. TECHNICAL DATA SHEET
TECNOFLOOR T-3020 v.22-11-2022
4/7

PERFORMANCE TABLE (DEPENDING ON SUBSTRATE AND APPLICATION SYSTEM


USED):
product paint paint multilayer Self-leveling
PRIMER EPw-1070 ±150-200 g/sqm/coat
PRIMER EP-1020/ PRIMER
±250- 300 g/sqm/coat
EP-1010
±275~300 ±300g/sqm/coat + spreading of silica
TECNOFLOOR T-3020 1,55 kg/sqm/mm
g/sqm/coat sand+400 g/sqm/coat

NOTE: All values that are included in the table above, are approximate and may fluctuate due to the situation of the
support or the methodology employed.

HEALTH AND SAFETY


These safety recommendations for handling, are necessary for the implementation process as well as in the pre and
post, on exposure to the loading machinery.

Respiratory Protection: When handling or spraying use an air-purifying respirator.


Skin protection: Use rubber gloves, remove immediately after contamination. Wear clean body-covering. Wash
thoroughly with soap and water after work and before eating, drinking or smoking.
Eye / Face: Wear safety goggles to prevent splashing and exposure to particles in the air.
Waste generation should be avoided or minimized. Incinerate under controlled conditions in accordance with
local laws and national regulations.

Anyway, consult the material and safety data sheet of the product (MSDS), or contact our technical department.

COMPLEMENTARY PRODUCTS
The following products can be applied as complements to their use. In this way, its physical-mechanical characteristics
are protected and improved depending on its exposure, desired finish, or type of substrate:

PRIMER EP-1010: epoxy resin with charges for filling existing holes in concrete or ceramic surfaces, to be
applied in a single coat
PRIMER EP-1020: epoxy resin to apply on concrete or ceramic substrates, improving adherence, absorbing
substrate moisture, and regularizing the planimetry of the substrate.
PRIMER PU-1050/PUc-1050: solvent-free polyurethane resin to apply on concrete, improving adherence,
absorbing substrate moisture, and regularizing the planimetry of the substrate.
PRIMER EP-1040: epoxy resin to apply on metal or ceramic substrates, improving adherence, absorbing
substrate moisture, and regularizing the planimetry of the substrate
PRIMER EPw-1070: water-based epoxy resin to apply on concrete, asphalt, metal, or ceramic substrates,
absorbing substrate moisture and regularizing the planimetry of the substrate.
PRIMER WET: epoxy resin to apply on very wet concrete or ceramic substrates, improving adherence,
absorbing substrate moisture, and regularizing the planimetry of the substrate.
MASTIC PU: polyurethane mastic for filling joints (use together with Tecnoband 100 when necessary).
TDS. TECHNICAL DATA SHEET
TECNOFLOOR T-3020 v.22-11-2022
5/7

TECHNICAL FEATURES
PROPERTIES VALUES
Density ISO 1675 1,55 g/cm³
Viscosity ISO 2555 3.000 - 3.200 cps
Density compounds A/B ISO 1675 1,65 g/cm³ / 1,15 g/cm³
Viscosity compounds A/B ISO 2555 4.500 - 4.900 cps / 600 - 800 cps
Mixing ration ( in weigth) 4,7:1
Solids content ISO 1768 100 %
VOC content (volatile organic compounds)
PASS: 16 g/l
SCAQMD rule 1113
Emission VOC (volatile organic compounds)
A+ (according to the French Attestation)
ISO 16000
Hardness Shore D at 7 days >95
Concrete adherence >1,5 MPa

Class 3 (PTV=58), suitable for surfaces with a slope <6%,


dry interior areas
Antiskid UNE 41901:2017 EX
Application with addition of Tecnoplastic C (7-8% by
weight)

Pot-life ±50 minutes


Drying time 4-6 hours
±7 days (avoid until this moment contact with water or other
Total curing time
reagents)
Recoat range time 6~8 hours
Walkable (pedestrian/ vehicular) ±24~48 hours / 7 days
Application temperature range (substrate /
5ºC ~ 35ºC / 5ºC ~ 30ºC
environment)
Use temperature Range (environment) -20 ºC ~ 80 ºC
Max. environment moisture 80 %
Results performed in the laboratory at 23ºC (73ºF) and 50% RH, under controllable conditions. These values may vary
depending on the application, climatology, or substrate conditions.
TDS. TECHNICAL DATA SHEET
TECNOFLOOR T-3020 v.22-11-2022
6/7

CHEMICAL RESISTANCES

INORGANIC ACIDS

Sulfuric 10% ++ (loss of color)


Hydrochloric 37% ++ (loss of color)
Nitric 20% ++ (loss of color)
Phosphoric 20% +++
ORGANIC ACIDS

Citric 10% +++


Lactic 10% ++ (loss of color)
Acetic 10% ++ (loss of color)
Formic 10% +
Tartaric 10% +++
ALKALIES

Sodium hydroxide 50% +++


Potassium hydroxide 50% +++
Ammonia 25% +++
SOLVENTS

White spirit +++


Xylene +++
Gasoline +++
Diesel +++
Acetone + / +++ (casual exposure)
+++ Resistant
++ Resistant with a lighter lose of properties
+ Resistant to spills or splashes

NOTE: resistance measurements were measured in permanent immersion for 21 days at 23 °C.

The information herein is to assist customers in determining whether our products are suitable for their applications. Our products are only intended for sale to
industrial and commercial customers. The customer assumes full responsibility for quality control, testing, and determination of the suitability of products for its
intended application or use.
We warrant that our products will meet our written liquid component specifications. We make no other warranty of any kind, either express or implied, by fact or
law, including any warranty of merchantability or fitness for a particular purpose since Tecnopol Sistemas S.L.U. does not control the execution, since Tecnopol
Sistemas S.L.U, does not control the execution. Our total liability and customers’ exclusive remedy for all proven claims is the replacement of the nonconforming
product and in no event shall we be liable for any other damages. While descriptions, designs, data and information contained herein are presented in good faith
and believed to be accurate, they are provided for guidance only. Because many factors may affect processing or application/ use, Tecnopol Sistemas S.L.U.
recommends that the reader make tests to determine the suitability of a product for a particular purpose prior to use.
No warranties of any kind, either expressed or implied, including warranties of merchantability or fitness for a particular purpose, are made regarding products
described or designs, data or information set forth, or that the products, designs, data or information may be sued without infringing the intellectual property
rights of others. In no case shall the descriptions, information, data or designs provided be considered a part of Tecnopol Sistemas S.L.U. terms and conditions
of sale. Further, the descriptions, designs, data, and information furnished by Tecnopol Sistemas S.L.U. hereunder are given gratis and Tecnopol Sistemas
S.L.U. assumes no obligation or liability for the description, designs, data or information is given or results obtained, all such being given and accepted at the
reader’s risk.
All data furnished refers to standard production using manufacturing testing tolerances. The product user, and not Tecnopol Sistemas S.L.U., is responsible for
determining the suitability and compatibility of our products for the final user’s intended use.
TDS. TECHNICAL DATA SHEET
TECNOFLOOR T-3020 v.22-11-2022
7/7

The liability of Tecnopol Sistemas S.L.U.and its affiliates for all claims is limited to the purchase price of the material.
Products may be toxic and require special precautions in handling. Users should obtain detailed information on toxicity, together with proper shipping, handling
and storage procedures, and comply with all applicable safety and environmental standards.
No freedom from any patents or other industrial or intellectual property rights is granted or to be inferred.