1 2 3 4

D E D E
Rebate to tank by specialist

9800
S

Acrylic to specialist information


IWS-751 SD

209
0
Terrazzo Trim IWS-751 E
TRM-851
TRM-851

Terrazzo trim
AV-2.3.1 T-2.3.1_1 AV-2.3.1
E Acrylic to specialist
Acrylic to specialist information

13
information

20
120°
IWS-751

SGN-353

05 05
SD

B T-2.3.1 TRM-851 B
Terrazzo Trim S E
Information Legend

366
0
text panel SD
T-2.3.2_1

1990
Scope Delineation
FX-551

00
GRP Cladding

12
13° FRP lining. See
3133 S aquarium specialist
CLG-854 information Fire Safety
3640
Sounds Of The Reef SGN-353 SD
AV-2.3.1
Sounds of the Reef A Door Exit Sign (EX3) (High Level Signage)
T-2.3.2 2090 FX-551
AV-2.3.1
Information text panel
E
55° B Door Exit Sign (EX1) (High Level Signage)
52°
T-2.3.1_2
W-2.3.2 W-2.3.2

C Door Exit Sign (EX2) (High Level Signage)

FE Fire Extinguiser Cabinet


T-2.3.2_2

Area 2.3 Area 2.3


Coral Reef Coral Reef S
95 Lighting

3220 1080 1080


1080 1080 Acrylic to specialist SD
SD
information EX-D04 Fixed Downlight Light
S E
PLS-103
01 E Emergency Lighting
01
IM-LG-DWG-AR- IM-LG-DWG-AR-
72730 72731 EX-L07a Linear Light
Rebate to tank by
specialist EX-L03 Strip Light Type
2100 IWS-751 TRM-851 Terrazzo trim

Caustic Projector

01 Lower Ground Floor Plan - Area 2.3


1 : 50 03 Lower Ground Floor RCP - Area 2.3
1 : 50
Vertical Caustic Projector

Ceiling Elements

Tanks
PLS-103
W-2.3.1 - Water Tank - Coral Reef Sprinkler
MEP Zone - Freckled Hawkfish
- Hector’s Goby SD Smoke Detector
- Butterfly Goby
- Yellowbreast Wrasse
S Communication Speaker System
- Yellowtail Wrasse
- Longfin Fairy Wrasse
A Speaker System A
02
CLG-854
IM-LG-DWG-AR-
W-2.3.2 - Water Tank - Coral Reef 2
DRS-652 FX-851
72734 - Lyretail Hogfish WIFI
- Bluefinpygmy Angelfish
- Dartfish
- Sixline Wrasse Slot Air Diffuser
Terrazzo cladding CLG-851 - Regal Angelfish
FX-854 LIN-951 FX-854
PLS-103
WL +5.738 Slot Air Intake
Terrazzo trim TRM-851 Rebate to tank
by specialist CCTV Dome Camera
LIN-951
AudioVisual
04 Wall Mounted CO2 detector
IM-LG-DWG-AR- IWS-751
4300

IWS-751 71652 AV-2.3.1 - Soft Coral


3800

- Dendronepthya Digital Exhibit Wall Mounted Manual Fire Call Points


LIN-951 W-2.3.2 W-2.2.3 W-2.4.1

Terrazzo AV-2.3.2 - Symphony of the Reef


Interactive sensors
cladding - Localised Audio Experience
W-2.3.2 SGN-353 W-2.3.1 W-2.3.1
SGN-352
FX-552 AV-2.3.3 - Digital Coral Wall
TRM-851
- Interactive Coral Projections
FL-951 LIN-951
FX-551 RAF-101 Tank support.
See structural
engineer
information
NB: The exhibition water tanks are a contractor design item. Thicknesses, materials
and connections highlighted in red are design intent and to be developed by water
N tank contractor. Acrylic specifications and performance to follow acrylic design

02 Lower Ground Floor Section - Area 2.3 documentation. Look and feel of exhibits are to match the visual intent shown in the
architectural packages. Tank substructure design to be optimised by contractor.
1 : 50

DEVELOPER CONTRACTOR LEAD CONSULTANT SUB CONSULTANT KEYPLAN PROJECT NAME PROJECT STAGE DRAWING TITLE

RSMLI Detailed Design Exhibition Design


Riverside, 22 Hester Road 03 18/11/22 DD Fit-Out Exhibition Design AR PROJECT DESCRIPTION DISCIPLINE Level LGF
Immersive Museum
London SW11 4AN

02 19/08/22 DD Fit-Out Exhibition Design AR Cultural Exhibition and Research Institute


Architecture
T +44(0)20 7738 0455
F +44(0)20 7738 1107
www.fosterandpartners.com © Foster + Partners 2020
01 01/07/22 DD Fit-Out Exhibition Design AR
CONSULTANT: SIGNATURE SIGNATURE SUB CONSULTANT 00 22/03/22 SD Fit-Out Exhibition Design AR
BUILDING NAME SCALE AT ISO A1
As indicated Detail Arrangement - Area 2.3
Rev. Date Reason For Issue Chk Red Sea Marine Life Institute SHEET ISSUE DATE 19/08/22
Middle East N

STAMP STAMP
www.wsp.com

AOR CONSULTANT
GENERAL NOTES
1. Do not scale drawings. Dimensions govern.
BUILDING NUMBER DRAWN BY
EM
AR
2. All dimensions are in millimeters unless noted otherwise. PROJECT CODE CONTRACT CODE ORIGINATOR VOLUME LEVEL/LOCATION DOCUMENT TYPE DISCIPLINE SEQUENCE NUMBER
W E 3. All levels are in metres unless noted otherwise. CHECKED BY
4. All dimensions shall be verified on site before proceeding with the work.
S 5. Any discrepancies on these drawings shall be brought to the immediate attention of Foster + Partners. PLOT NUMBER
TB-04-05 APPROVED BY
MS 1TB01005 - 005D01 - FOS - IM - LG - DWG - AR - 71713
6. Any areas indicated on this sheet are approximate and indicative only.