Before adding new device, please check following checklist on ACTi device:
Make sure the ACTi device is TCP 2.0 compliant
Plug in the network cable in the WAN port
- Page 3 -
[Support Package]
For Genetec Omnicast v4.0 installation programs, please visit Genetec Web Site or
contact Genetec Sales directly.
Following steps list how to activate license key from Omnicast v4.0
- Page 4 -
[Support Package]
- Page 5 -
[Support Package]
- Page 6 -
[Support Package]
- Page 7 -
[Support Package]
- Page 8 -
[Support Package]
- Page 9 -
[Support Package]
3. Click on “System Info”. You can see the Firmware Version is
A1D-M2N-V2.05.12-AC, this is the TCP 2.0 Version.
4. Note that V2.05.12 indicates this is a TCP 2.0 compliant firmware, and
the version is V2.05.12
- Page 10 -
[Support Package]
Step 2: Check the Video Streaming Method is RTP Over UDP & Multicast.
1. Click on “Video Setting“
2. Choose the Streaming Type is “Version V2.0”
3. Click on “Setting” Button to apply.
- Page 11 -
[Support Package]
4. Select Streaming Method as “RTP Over UDP & Multicast“.
5. Change the Video RTP Over Multicast port to 4780, this is the Omnicast
software default port.
6. Click on “Apply” Button.
7. Click on “Save Reboot” Button to reboot the device.