AT200 From UHZ-517CFB Side Mounted LG

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

AT200 ‫ى‬ዂฦ໫ᅂ࿋Վໃഗ!

ፌߛ࿒‫܈‬੗‫ٳ‬420ņ ׂ೗჋ದॲኮ຺

MAGNETOSTRICTIVE LEVEL TRANSMITTER

႙ࡽ MODELǖAT200 ߾ፕᇱ૙ WORKING PRINCIPLE


AT200ဣଚ዇ీ‫ى‬ዂฦ໫ᅂ࿋Վໃഗ๟ฉ࡛႓ฤᅏ AT200ဣଚ዇ీ‫ى‬ዂฦ໫ᅂ࿋Վໃഗ๟ᅜ઒ӿႚ๕ࠦ
՗ᆶ၌ࠅິჺ݀‫ڦ‬ႎׂ೗ă๟ᅃዖߛ৛‫ڦ܈‬ᅂ࿋֪ଉᅏ ۨሞUHZ-517ဣଚ‫݋ى‬ዹᅂ࿋ऺዷ‫֨ྔ࠶ڞ‬Ljഄ‫ت‬ᇀཞᅃ
՗ăᅏ՗֪ଉ‫ٷྷݔ‬Lj߾ፕ੗੍LjሎႹ๑ᆩ࿒‫ߛ܈‬Ljᆶ ‫ى‬᳘ဣཥዐLjᆯփ‫ڦىڞ‬փႮߒ࠶(֪߇)Ă‫ى‬ዂฦ໫၍(հ
‫ܠ‬ዖҾጎႚ๕Ljۙ๬੺যLjਏᆶटߛ‫ڦ‬ႠॏԲă ‫ڞ‬၍)Ă዇ీ‫ۉ‬ጱևॲ‫ڪ‬և‫ݴ‬ፇ‫ׯ‬ăஞ؋݀ิഗ݀‫ୁۉ؜‬ஞ
AT200 Series Magnetostrictive Liquid Level Transmitter ؋(ഐ๔ஞ؋)ᄂհ‫ڞ‬၍‫د‬խLj‫ୁۉ‬ஞ؋ׂิ‫ׇىڦ‬ᇑ‫ޝ‬൰
is a new product developed by Shanghai Xingshen Instruments ా‫ׇى࣍ىڦ‬๐ଉ၎ेႚ‫ׯ‬அ჉‫ׇى‬Ljׂิຨ้౦૰Lj๑
Co.,Ltd It is a liquid level instrument with high precision, հ‫ڞ‬၍౦‫ۯ‬ժׂิዕኹஞ؋Ljᄂհ‫ڞ‬၍‫࣮د‬ăཚࡗ֪ଉ‫؜‬
wide measurement range and high reliability. Its mounting ഐ๔ஞ؋ࢅዕኹஞ؋ኮक़‫้ڦ‬क़ઠ৛ඓ‫ں‬ඓۨԥ֪ᅂ࿋Lj
types are optional. It can be used where the temperature is ๼‫؜‬4-20mA‫ୁۉ‬႑ࡽă
high. The commissioning is simple. This transmitter has high AT200 Series Intelligent Magnetostrictive Level
performance/cost ratio. Transmitter is composed of magnetism-insulation stainless steel
tube (measuring pole), magnetostrictive line (guided wave line),
रຍ֖ຕ SPECIFICATION
movable magnetic floater and electronic parts etc. It is attached
֪ଉ‫ྷݔ‬Measuring rangeǖ300~8000mm outside UHZ-517 magnetic level gauge and couples with level
৛ඓ‫܈‬Accuracyǖ±0.01% F.S gauge. Impulse generator emits a current impulse (inception
๼‫؜‬႑ࡽOutputǖ4~20mA DC ܾ၍዆Ăෙ၍዆!HART impulse) along with guided wave line. The magnetic field
ࠃ‫ۉۉ‬უPower supplyǖ24V DC (13.5~36V) produced by the current impulse
޶ሜీ૰Load capacityǖļ600ˮ combines the magnetic circle
and magnetic field vector in
߾ፕ࿒‫܈‬Working temperatureǖ-40~200ņ<!-40~420ņ
floater and generates spiral
࣍ৣ࿒‫܈‬Ambient temperatureǖ-40~65ņ magnetic field. It will result in
‫ڪࢺݞ‬पEnclosure classcificationǖIP66 instantaneous torsion, actuate
֪߇֌ዊProbe materialǖ304 316L g u id ed wave wire twist and
produce terminal impulse, and then the
terminal impulse will return along the
guided wave wire. By measuring the time
between the inception impulse and terminal
impulse, the level can be determined, and
4-20mA current signal will be output.
႙ࡽࡀ߭ SPECIFICATION
AT20 0 Քጚ႙!๼‫؜‬ଇ၍዆4~20mA DC HART R2

Basic type, two-wire 4~20mA output

1 ๼‫؜‬ෙ၍዆4~20mA DC HART R3
Three-wire 4~20mA DC output

2 ๼‫؜‬ଇ၍4~20mA DC HART R4
Two-wire 4~20mA DC output

3 ๼‫؜‬ෙ၍዆4~20mA DC HART R5
AT200

Three-wire 4~20mA DC output

D ߰Ԗ႙ Explosion proof

ExdIIBT4~T6 ExdIICT4~T6

E ԨҾ႙ Intrinsically safe

ExibIICT4~T6

EF ԨҾ႙‫ټ‬Ҿඇ߰૗ቆ ExibIICT4~T6

Intrinsically safe with safety barrier

H ‫ټ‬HARTཚ႑ၹᅱ HART protocol

.ŕŕŕ ֪ଉ‫(ྷݔ‬mm)Measure range

Ҿ!ጎ!ጀ!ᅪ AT200Ҿጎ้Ljׂ೗ူ‫ࢤڦ܋‬෥ଭ࿋ՔऻႴ
AT200ాዃҾጎ AT200ྔዃҾጎ AT200ᇱ૙๖ᅪ཮ ᇑUHZ-517ဣଚᅂ࿋ऺ‫ڦ‬ଭ࿋ਗ਼‫ت܈‬ᇀཞᅃ຤ೝ၍ฉă
Internal mounting External mounting Working principle diagram On installing, the red zero mark should be at the same
level as UHZ-517 series level gauge.

ฉ࡛႓ฤ ᅏ ՗ ᆶ ၌ ࠅ ິ ‫(ࣆۉ‬Tel.)ǖ+86-021-58308800 58309977 Http: //www.c10.cn


SHANGHAI XINGSHEN INSTRUMENT CO.,LTD ‫د‬ኈ(Fax)ǖ+86-021-58309955 E-mail: 8800@c10.cn 39

You might also like