Professional Documents
Culture Documents
RedGear Catalog 2022 v1.0
RedGear Catalog 2022 v1.0
RedGear Catalog 2022 v1.0
com
RedGear &
RedPipe ®
Custom Installation Supplies
LINEAR HEAT &
AIR SAMPLING
INSTALLATION
MATERIALS
Scan QR Code
For More
Information
ABOUT US
Traditionally the fire industry has adapted off the shelf
installation materials to install air sampling smoke and
linear heat detection systems. At the request of a
manufacturer and with their assistance, RedGear
evaluated the installation materials for these systems,
and with the assistance of the installers redesigned
new, more practical installation supplies made
specifically for these systems.
Fire Resistant
UL Listed
Lowest Cost Guaranteed
Pipe is Approved Plenum Spaces
Meets NFPA Standards
Designed, Built and Shipped
from North Carolina, USA
1 www.safefiredetection.com
CONTENTS
Strain Relief
Optional
Intrinsic 5 3ft. (1m) 7
2 Safety Mounting Accesories
Barrier
4 Splice Connector 15’ when using Guidewire
Splice Kits can be
Safe used for Install AND 8
Repair in place of
1 Optional
Distance
Linear Heat Detection
Alarm Point
Distance Locator
Zone 1 Zone 2
J-Boxes
Locator
Fault Alarm Power Alarm Fault
Zone
Location
3
Zone
Location
System Components
www.safefiredetection.com
704-821-7920
3 www.safefiredetection.com
ADDRESSABLE SYSTEM EXAMPLE
ADDRESSABLE
JBox
SYSTEM
3’
Contact
Monitor
Module ONE LINEAR
HEAT DETECTION
SYSTEM PER
CONTACT MONITOR MODULE
Optional Zone
JBox CONVENTIONAL
SYSTEM
3’
ONE LINEAR
HEAT DETECTION
SYSTEM PER
ZONE ON PANEL
Optional Zone
To Determine
Cable Amount: Spri
nkle
40=r r Pip Double
2πr LLH
HDDC
Caabble
le
e Loop
Cable Tie
Freezer or Rack
LHD Cable Mount
FLUE Attach to sprinkler pipe mounting
attaching cable every 3’ (1m).
CONVEYORS
GENERATORS
RedGear®
Guidewire/Messenger Wire Mount 3’ (1m)
1
Support Supplies
Universal Surface Mount
There are four areas you 2
with built in Cable Tie
could use linear heat detection
Fire Resistant to protect a conveyor from
different fire scenarios 3
RedGear®
Determine the number
RedGear®
EyeBolt with of clips you need by
Guide Wire every 15’(5m) dividing the length
Cable Clip Tie
OR One Piece Cable Clip, All Cable Tray Clip
of the cable tray by
3, then add 1.
Cable Clip Ties in one Design. One Piece with built-in Cable tie
every 3’(1m).
Fire Resistant Fire Resistant Sine Wave Calculation for Cable Tray to
determine amount of cable required
5 www.safefiredetection.com
INSTALLATION SUPPLIES
ISB MODULE
Intrinsic Safety Barriers for
Explosive and Hazardous Areas
S6652
Distance To Alarm
Safe Area
Fire Alarm Equipment
Zone 1 Zone
Zone 22
Fault Alarm Power Alarm
Zone1
Zone Zone2
Zone
Location
Location Location
Location
www.safefiredetection.com
www.safefiredetection.com
704-821-7920
704-821-7920
Part# DLM-Z2
System Components
ISB Protecting
DLM-Z2 1 1. RedGear Intrinsic Safety Barrier
2. J-Box (beginning of LHD zone)
Your
To 3. End of Line Test Switch
Fire Alarm 24VDC
Control Panel
Note: A additional ISB is necessary for each zone
DLM-Z2 Example
SafeSafe
One Conduit
For Up To 2 Zones Distance To Alarm
Zone 1 Zone
Zone 22
Fault Alarm Power Alarm
Fault Alarm Fault
Fault
Zone1
Zone Zone2
Zone
Location
Location Location
Location
www.safefiredetection.com
www.safefiredetection.com
704-821-7920
704-821-7920
Part# DLM-Z2
Programmable Configurations
Ÿ 1 Zone
Ÿ 2 Zone
Your Ÿ Cross Zoned
Fire Alarm
Control Panel
7 www.safefiredetection.com
Text Imprinted Covers
J-BOXES
No more Hole Saws Needed X
NO MORE DRILLING
NOTE: Text on product is not White
LHD Cable
Splice Connector
In Line
Conduit Test Switch
Connector or J-Box
NO HOLE SAWS
REQUIRED
NEMA 4 (IP66)
NEMA 6P (IP68)
NEMA 4X (IP67)
DIGITAL
LINEAR HEAT
DETECTION CABLE
TM
www.safefiredetection.com
Spr
CABLE TIES
Dou inkl
ble er P
Loo
pC
able
ipe
Tie
New RED nylon 6.6 fire resistant
cable ties; multiple sizes for use with Line
pre-action sprinkler systems and other Cab ar He
le a t De
tect
applications ion
UNIVERSAL SMALL
3/4”-2” SINGLE
DOUBLE LOOP TIE
LOOP PRE-ACTION SPRINKLER
2 ½” PIPELOOP
- 3” DOUBLE DOUBLE LOOP
RedGear ® Small Single RedGear ® Pre-Action 3/4”- 2”
Loop Cable Ties Double Loop Cable Ties
Part #: RG1114C 100/pk Part #: RG1112C 100/pk
Part #: RG1114M 1000/pk Part #: RG1112M 1000/pk
UNIVERSAL LARGE SINGLE LOOP TIE PRE-ACTION SPRINKLER PIPE DOUBLE LOOP
9 www.safefiredetection.com
UNIVERSAL RedGear
RedGear
Cable
Cable Clip-Tie
Clip-Tie
CABLE CLIP-TIE 3’ (
1m
)
Typical Installation
TIME Combines a beam clamp and cable tie all in one for easy use. Rated from
-100°F to 392°F(-73°C to 200°C).
RedGear®
Cable Tray Clip (2 Sizes)
One Piece with built-in Cable tie
Fire Resistant
11 www.safefiredetection.com
FREEZER MOUNTS
Sprinkler Pipe
FREEZER
Freezer-Rack
Pre-Action Freezer-Rack
Pre-Action
Mount
Mount Mount
Mount
3” C Channel
Rack Mount:
1 Push mount on rack.
2 Secure Linear heat
detection cable with
built-in cable tie. 3/4”- 2” 2 ½” - 3 ½”
RedGear Freezer-Rack RedGear Pre Action RedGear Pre Action
Mount Double Loop Cable Ties Double Loop Cable Ties
(Every 3’) (1m) Part #: RG1128C 100/pk Part #: RG1112C 100/pk Part #: RG1113C 100/pk
Linear Heat
Detection Cable Part #: RG1128M 1000/pk Part #: RG1112M 1000/pk Part #: RG1113M 1000/pk
almost anywhere
FIRE RESISTANT
SURFACE MOUNT & One Size Fits All LHD Cables
CABLE TIE IN ONE Simply Apply Surface
Mount Adhesive to Back
Built-in
Cable Tie
Or Use The Built In
Screw Mount*
RedGear
13 www.safefiredetection.com
TEST SWITCH
New easy to use test switch, no
more complicated hard wired boxes X
now just flick of a switch
Outside View
TEXT IMPRINTED BOX COVER
NOTE: Text on product is not White
System Components
1. J-Box
2. Splice Connector
3. Strain relief Connector
4. Linear Hear Detection Cable
5. Mounting Accessories
6. Strain Relief Connector
7. End of Line Test Switch
IMPRINTED
METAL SWITCH
PLATE
WITH NEW
IMPRINTED LID RedGear HD/ELR-Test Switch
Part #: RG5223
FIRE RESISTANT & EZ KNOCKOUTS
LHD
Splice Connector
Connector
SPLICE KIT
No need to replace entire cable, Splice Barrel
No tape or screws needed
RedGear
5”
Strain Relief
Connector
1”
Strain Relief
Connector Splice Barrel
NEW WEATHERPROOF SPLICE FOR LHD
USE WITH QUICK SPLICE IN-LINE CONNECTOR
RedGear ®
Part #: RG1126
15 www.safefiredetection.com
TYPICAL SPLICE EXAMPLE:
NEW REDGEAR SPLICE KIT
NO MORE TAPE, NO MORE LEAKS Existing Cable
Existing Cable
New Cable
WEATHERPROOF
INSTRUCTIONS
1. Strip outer LHD jacket back 1”on one end of 2. Slide a Strain Relief connector on the end of
LHD to be spliced. Strip the inner conductors each LHD cable. As illustrated.
back ½”. Repeat on the other LHD cable to be
spliced. Strain Relief Connector
Strain Relief Connector
3. Slide the splice barrel onto one of the LHD 4. Lift the Splice Connector’s tabs up, insert one
cable ends. end of the LHD cable ino to the Splice connector.
Splice Barrel
Close the tabs to secure the cable.
Splice Connector Tabs
5. Repeat Step 4 to attach the other end of LHD 6. Slide the barrel over the connector, screw the two
cable to the opposite end of the Splice strain relief connectors onto the splice barrel,
Connector, and complete the connection. and tighten. You have completed your splice.
Tighten
Splice, End Jbox
of Line or
or Test
Jbox Switch
17 www.safefiredetection.com
Snap-In Snap-In TENSIONER
Eyebolts
INSULATED EYE BOLTS
Guidewire
4.5”
System 2.4”
19 www.safefiredetection.com
RedPipe 8’ Pipe
Lengths Can Be
RedPipe is a UL listed fire resistant Shipped Overnight
3/4" CPVC pipe, approved specifically 8’(2.4m) OR 15ft(4.5m) Lengths
for use with any UL Approved 8’ Length 3/4” CPVC
air sampling smoke detector Part #: RP5209
15’ Length 3/4” CPVC CSFM
Part #: RP5209-15
UL Approved
For Plenum Spaces Pipe Kit 3/4” CPVC
Covers a 50’x50’ Area
Contents: 96’ of RedPipe, 3-90 Degree Elbows, 8-
NFPA PRINTING ON PIPE Couplings, 1-Tee, 2-Endcaps, 32-Pipe Hangers
Printed in Both English and Spanish Part #: RP5240
Threaded Rod
Push Down to
2 Snap in Place
1 JUST
3
SNAP
IN PLACE
OPEN CLOSED
RedPipe 3/4” Pipe Clip Hanger
One Piece Pipe Clip, Pipe Size 3/4 In, Max Load 250 Lb, For
Vertical Or Horizontal Tubing Support.
Part #: RP5212 25/pk
RedPipe Square Nut
Required with pipe clip hanger
Mount with Screw, Bolt or Threaded Rod to install threaded rod.
Part #: RP5213 50/pk
3/4” 90° Radius Bend 3/4” Low Profile 3/4” 90° Elbow 3/4”45° Elbow
90° Radius Bend
Part #: RP5215X 10/pk Part #: RP5230X 10/pk Part #: RP5202X 10/pk Part #: RP5203X 10/pk
PIPE FITTINGS
Part #: RP5206X 10/pk Part #: RP2226 Part #: RP5204X 10/pk Part #:RP5205X 10/pk
FILTER CAPILLARY
A B
Quick Quick
Air Sample Disconnect ½ Capillary Tubing Disconnect 3/8” Capillary Tubing
Points ½” tubing 3/8” tubing
Use in drop ceiling or in- Use in drop ceiling or in-
3/4” Inline Air Filter Use in drop ceiling Use in drop ceiling cabinet applications for Use in drop ceiling cabinet applications for
or in-cabinet or in-cabinet air sampling smoke or in-cabinet air sampling smoke
Used to filter out dust in the
applications for air applications for air detection. applications for air detection.
air going into the air
sampling smoke detection sampling smoke sampling smoke 3/8”ID 1/2” OD sampling smoke 1/4”ID 3/8” OD
system. Used in hazardous detection. detection. detection.
and industrial environments.
A Part #: RP5216 Part #: RP5225 Part #: RP5227 50ft. Part #: RP5223 Part #: RP5219 50ft.
Part #: RP7125 Note: 2 Required for
each Capillary Drop
B Part #: RP5222 Part #: RP5229 100ft. Part #: RP5239 100ft.
21 www.safefiredetection.com
REDPIPE ACCESSORIES RedPipe
Everything you need to TEST WITHOUT
GOING TO
complete your installation CEILING
Test Point
TESTING ACCESSORIES
(Telescoping)
Laser Smoke Blue LED Smoke
Smoke Testing Pen Detector Tester Detector Tester
Smoke Pen used in the Telescoping smoke Aresol based smoke
testing of light scattering, detector tester. Used to detector tester. used to
laser, and cloud chamber test Laser based and hard test photoelectric and blue
type Air Sampling Detectors. to reach smoke detectors. LED Smoke Detectors.
DO NOT PAINT