NOTES:

1. ALL DIMENSIONS IN MILLIMETERS.


2. BRACING TO BE PLACED ON INSIDE OF MESH.
3. FASTENERS: 6 GAUGE ALUMINUM OR HEAVIER
4. ALL POSTS AND PIPE RAILS TO BE GALVANIZED, SCHEDULE 40 PIPE TO BE USED.
5. ALL HARDWARE TO BE GALVANIZED.

3000
90MM O.D. END TERMINAL POSTS INSTALLED AT
ALL ENDS, CORNERS, STRAINING AREAS AND
GATES. ALL POSTS TO BE CAPPED.
43MM O.D. TOP RAIL 178MM LINE COUPLINGS

38MM OR 50MM NUMBER 9 GAUGE


GALVANIZED WIRE FENCE MESH
(REFER TO SIZING TABLE BELOW)

STRETCHER BAR BANDS AT 3000MM O.C.


1) STEEL: 3MM X 19MM MINIMUM
2) ALUMINUM: 5MM X 19MM MINIMUM
1800

43MM O.D. BRACE RAIL (1800MM HIGH SINGLE STRAND 9


FENCE ONLY). TO BE INSTALLED AT ALL GAUGE GALVANIZED
ENDS, STRAINING AREAS, AND STEEP WIRE WOVEN THROUGH
TOPOGRAPHY. FENCE MESH OR WIRE
5MM X 19MM STRETCHER BAR TIED AT 450MM O.C.
DROP FORGED TURNBUCKLE FINISHED GRADE
50

300
UNDISTURBED
1050

SUBGRADE
1200

TOP OF CONCRETE FOOTING TO SURFACE TREATMENT


BE SLOPED AWAY FROM POST TO OVER ALL DISTURBED
ALLOW FOR POSITIVE DRAINAGE. AREAS DUE TO FENCE
INSTALLATION TO
150

32MPA CONCRETE PIER FOOTING SET TO A DEPTH RECEIVE 300MM


OF 1200M. POST TO EXTEND 1050MM INTO CENTER SCREENED TOPSOIL
OF CONCRETE PIER FROM FINISHED GRADE. AND SEED UNLESS
CONCRETE FOOTING TO BE 300MM DIA. FOR ALL OTHERWISE SPECIFIED.
300 ENDS, CORNERS, STRAINING AREAS AND GATES AND 250
250MM DIA. FOR ALL LINE POSTS.

FENCE HEIGHT LENGTH BETWEEN POSTS MESH SIZE (9 GAUGE FOR ALL HEIGHTS)
900 MM 3000 MM 38 MM WIRE MESH
1200 MM 3000 MM 38 MM WIRE MESH
1500 MM 3000 MM 38 MM WIRE MESH
1800 MM 3000 MM 50 MM WIRE MESH

CHAIN LINK
FENCE
PARKS PLANNING
AND DEVELOPMENT
COMMUNITY SERVICES DEPARTMENT
DRAWN BY: MW APPROVED BY: MW DETAIL NUMBER
DATE: 2022-04-22 SCALE: 1:30 P-301