ActronConnect Module
ACM-1
INTRODUCTION
SAFETY INSTRUCTIONS
CONGRATULATIONS on your purchase of an
ActronConnect Module! This has been designed and
Safety instructions and warnings provided on this
engineered to give you total control of your ActronAir
installation manual are in-exhaustive and given as
ducted air conditioner, whether you are at home or
a guide only. Prevailing WH&S regulations must
away. By using either the ActronConnect App on your
be observed and will take precedence to the safety
Apple iOS devise or through supported web browsers
instructions contained in this manual. Safe work
from any smart phone, tablet or PC / Mac, you can now
practices and environment must be of paramount
monitor and control your air conditioner from wherever
importance in the performance of all service
you have internet connectivity.
procedures.
The procedures outlined in this guide are provided • Ensure that all safety work procedures & Instructions
to correctly & safely install the ActronConnect are adhered to at all times in order to prevent personal
Module (ACM) to an appropriate ActronAir ducted air injury or damage to the equipment.
conditioning system. Failure to follow these procedures
may result in personal injury, damage to the air • Only licensed service persons are allowed to perform
conditioner, damage to the ActronConnect module or the procedures described in this manual.
incorrect operation of the air conditioning system. Such • The indoor (evaporator) unit electrical panel has
failure could render your warranty null and void. 230VAC electrical components inside. PLEASE
ISOLATE THE INCOMING POWER SUPPLY BEFORE
COMMENCING WORK. Supply can be isolated at the
Main Isolator located near the Air Conditioner (if fitted)
KIT CONTENTS LIST or at the Main Supply Circuit Breaker in the Distribution
Board supplying the Air Conditioner. Correct Lock Out
1 Pc - ActronConnect Wi-Fi Module & Tag Out procedures should be followed to ensure
(ActronAir Part No. ACM-1) Power Supply is not re-energized accidently.
1 Pc - ActronConnect Antenna • The ActronConnect Module is IP20 Rated - NOT
1 Pc - Power Supply pre-wired with FOR OUTDOOR USE. Install your ACM away from
Power & Data cables - Sold as Spare Part Kit excessive dust, heat and moisture.
(ActronAir Part No. 2020-200K)
1 Pc - Adhesive Back Wiring Diagram label • The ActronConnect Module is not a toy, keep away
(ActronAir Document No. WD0904) from children and ensure that they are not allowed to
1 Pc - Installation & Commissioning Guide play or tamper with the device.
(ActronAir Document No. 9590-1000) • The air conditioning electrical panel & the Actron
1 Pc - Quick Start Guide Connect module / kit contain static sensitive electronic
1 Pc - Double Sided Tape (50 x 30 x 2mm) components. Careful handling & correct anti-static
2 Pcs - M3 x 4mm Pan Head Screws procedures must be followed to prevent damage of the
2 Pcs - #6 x 30mm Pan Head Needle Point Screws equipment. Failure to protect the electronic components
1 Pc - Shipping Carton from static electricity may cause unrepairable damage,
which is NOT COVERED for replacement under
Warranty.
SPECIFICATIONS
Lid- Electrical
Panel
Indoor Unit
Step 1.1.3. Mount the ActronConnect power supply kit, using either of the two options below, to the base of
the electrical panel as shown below:
Double Sided
Tape NOTES: Use double sided tape where there are no holes in the Electrical Panel base.
Make sure that the base of the electrical panel and the power supply are
clean and free of dirt or dust in order to provide a strong tape adhesion.
“PLUG A” P1
2 Pin Power 2 Pin Socket
Connector Ultima Power
Auxiliary Power Connector
Socket
P1
2 Pin Socket
Connect “PLUG A” (2 Pin Power Connector) for the Unplug Ultima 2 Pin Power Connector from “P1”
230VAC of the power supply into the corresponding and connect “PLUG A” as in Step 5A above.
2 Pin Socket labelled “P1 (240VAC)” on the Indoor Then, plug the Ultima power connector into the
PCB AMIB. (This plug only goes in one way, ensure auxiliary power socket.
it is in correct orientation before pushing it all the
way in).
Step 1.1.6. Connect “EARTH RING LUG” to the earthing bolt of the indoor unit electrical panel. Unscrew
the nut, remove the washer & slide the EARTH RING LUG over the bolt making sure all of the existing
earthing lugs remain connected. Replace earthing washer & nut and tighten the nut securely.
Earthing Bolt
& Washer
Existing
Earth Wires
ACM
Earth Wire
Step 1.1.7. Connect “PLUG B” (4 Pin JST) for the data of ActronAir Connect Module into the
corresponding 4 Pin Socket labelled “J4 DATA” on the Indoor PCB AMIB. (This plug only goes in one
way, ensure it is in correct orientation before pushing it all the way in).
Indoor ACM
PCB AMIB “PLUG B”
(4 Pin JST)
J4 DATA
(4 Pin Socket)
DATA
DATA
Large
Cable Gland
NOTE: For optimum performance & module communication integrity, keep the ActronConnect
Module data cable as far as possible from the 230VAC mains.
Step 1.1.9. Take the wiring diagram with adhesive back, peel off adhesive protection strip & stick the wiring
diagram unto the front the electrical panel lid.
Indoor Unit
Lid- Electrical
Panel
Step 1.1.10. Check all connections and screw lid back onto indoor electrical panel.
Step 1.2.1. Install the ActronConnect Module to a suitable secure location, like a roof joist or similar using
the supplied screws. Keep the module at least 0.5m away from the roof line and 1m from the indoor
unit, large metal objects or other sources of interference (e.g. antennas, exhaust fans, duct work, etc.).
Also ensure it is kept away from potential sources of dust, heat & moisture (i.e. light fixtures, heaters,
bathroom exhaust fan outlets, etc.)
ActronConnect Module
Roof 0.5
m> Manhole
Indoor Unit A
DETAIL - “A”
NOTES:
1. Maximum Allowable Cable Length between the indoor unit and the ActronConnect module is 10m. This can be
achieved with the use of a 2-Way Joiner PN: 2045-121 (Sold Separately) and a 7m ACM extension cable PN: 4070-027
(Sold Separately). The Actron Power Supply kit comes pre-wired with 3m cable. Do not run ACM cable in parallel with the
240V power supply cable and keep 300mm minimum distance from other cables (mains, data, antenna, etc).
2. DO NOT USE Actron CAT5E zone cables to extend ACM cables.
3. Locate the ActronConnect Module as close as possible to the ceiling and the manhole for ease of access, ensuring that
LED is facing towards the manhole and that the roof insulation does not come into contact with the module.
4. Do not install ActronConnect Module in roof cavities where temperature can exceed 60oC. In the event where you require
to install the Actron Connect Module below the ceiling line (Eg. Storage cabinet), please ensure you use an appropriate
plastic enclosure (supplied by others) that complies with all relevant safety codes, regulations and standards.
Mounting Orientation
As much as possible, install the module in a direct line of sight with the router and keep the antennas parallel.
Location / Positioning
Do not locate the module where the signal will be blocked by any large metal, concrete structure or objects
with high water content. People, animals and plants are composed mostly of water. Make sure that these do
not interfere with the module signal. Maintain at least 0.5m distance between the ACM & router antennas.
Avoid getting the antenna in direct contact with any metal or near power supply.
Step 1.2.3. Refer to the module mounting diagram - Requirements for ACM Optimum Signal Performance,
for the best mounting direction of the module based on your particular installation requirement.
Step 1.2.4. Refer to the wiring diagram for the cable connections on pages 29 - 33.
Step 1.2.5. Take the ActronConnect module 3m Grey Data Cable running from the indoor electrical panel
& run it to the installed module, ensuring it is in a position where it cannot be easily damaged and it is at
least 300mm away from any other installed cables (i.e. power, lights, PC data, TV antenna, etc.). If it is
impossible to avoid running the ACM data cable close to the other cables, run it across the other cables
at 90 degree (do not run in parallel).
3m ACM
Data Cable from the
Indoor Unit
ActronConnect
Module
Step 1.2.6. Secure the 3m Grey Data Cable to the timber roof joist or similar with the cable ties or other
suitable cable fixing fasteners. Do not loop any excess cable in a tight loop. Leave it loose.
Antenna ACM
Data Socket
Label - ACM
Data Socket
Antenna
“PLUG C”
(RJ45 Data Plug)
ACM
ACM ACM Data Socket
Antenna Socket Data Socket
Step 1.2.8. Check all connections & cables to ensure correct connections and cables are secured properly.
Step 1.2.9. Power-up the air conditioner by turning-On the main isolator or at the Main Supply Circuit
Breaker in the Distribution Board. Ensure that the air conditioner powers up and operates correctly.
Step 2.1. Download the ActronConnect “App” from the Apple app store.
Step 2.2. Open the “App” in order to create your account with ActronAir.
Step 2.4. Terms & Conditions* page will appear, read through it and accept:
SCROLL DOWN
to read the
Terms & Conditions
and Accept
NOTE:
• Ensure that you read the Terms &
Conditions and if you are happy, press
“Accept” to proceed with commissioning.
NOTE:
• You can chose any password, which is not necessarily the one you use for your email
access. It is also advisable to create a different password for your ActronConnect
account, for your extra security.
Step 2.6. Set up your air conditioning type & number of zones. Then press the “next” button and the
“Welcome” page will appear. Close the “App”.
4
Do not press “next”
NOTE:
• You may need to Turn-On your Wi-Fi, if it is Turned-Off.
Step 2.8. Select the “ActronConnect” Wi-Fi network for your air conditioner:
NOTE:
• You are now connected to ActronConnect network.
• You must be within 15 meters between the installed
ActronConnect Module and the configuration device
(iphone, ipod, PC...), to ensure optimum communication
signals.
Wi-Fi signal
IMPORTANT:
iOS 6 - the Wi-Fi signal ( ) will appear almost instantaneous after
selecting ActronConnect in the list of Network.
iOS 7 and later - wait for the Wi-Fi signal ( ) to appear (approximately
1 minute). If it hasn’t appear for 1 minute, continue with
the set up process.
Step 2.9. After establishing your air conditioner’s Wi-Fi network (after connecting to ActronConnect),
re-open the ActronConnect “App” and click “next”:
Step 2.11. Set up your air conditioner network connection to your router by selecting your SSID (your
Wi-Fi network name) and typing your Pass Phrase (your Wi-Fi network password).
NOTES:
• SSID - Service Set Identifier, the name of the wireless
network. All of the wireless devices on a wireless local
area network (WLAN) must employ the same SSID in
order to communicate with each other.
3 • Pass Phrase - Password for your Wi-Fi network.
Step 2.12. Wait for the system to finish encrypting your air conditioner for access:
Step 2.14. Re-open the “App” and press the “home” button:
IMPORTANT:
IMPORTANT :
DONOT
DO NOTMOUNT
MOUNT ACM
ACM DIRECTLY
DIRECTLY ON INDOOR
ON INDOOR UNIT
UNIT.
- FOR OPTIMUM PERFORMANCE OF Wi-Fi
- FOR OPTIMUM PERFORMANCE OF
SIGNAL MOUNT 1 METRE AWAY (OR GREATER)
WIFI SIGNAL MOUNT MINUMUM OF
AND NOT ABOVE THE INDOOR UNIT.
1 METRE AWAY & NOT ABOVE
EVAPORATOR
- MOUNT MINIMUM 0.5 METRE BELOW ROOF
LINE.
- MOUNT MINIMUM 1 METRE BELOW ROOF
ACTRON
CONNECT
ACM POWER SUPPLY MODULE
(240VAC - 12VDC 1.3A) (ACM)
ANTENNA
P1
E2
3G LPW WIFI ETH
AC IN DC OUT ADJ
A N -V +V RST MODE
BROWN
GREEN / YELLOW
BLUE
ETH AC PWR
BRN / WHITE (GREEN)
BROWN
EXV
BLUE
BROWN
COIL IN
EC CONTROL
SENSOR
COIL OUT
SENSOR
EARTH
SCRN
DATA
NEUT
COM
PWR
COM
KEY
ACT
BLUE
WC
BROWN
BROWN
NEUT ACT RLY
GREEN / YELLOW
BRN / WHITE (GREEN)
WIRING DIAGRAM
WIFI
MODULE
BLUE
BROWN
ECM
IF-1 CONTROL
1 EC MODULE ANTENNA
EXV
EXV
IF FITTED
INDOOR FAN (IF) INDOOR (DEPENDANT ON
P1
E2
COIL IN
INTERNAL AUTO RESET SENSOR MODEL VARIANTS)
OVERLOAD PROTECTION FERRITE
RST MODE
EC CONTROL
SEE JUMPER PIN POSITION
INDOOR
COIL OUT TABLES ON UNIT WIRING DIAGRAM
SENSOR FOR CORRECT POSITION
N
A
ACT
NEUT
EARTH
DATA
COM
KEY
PWR
COM
SCRN
EMC-1
SCREEN
E WIRES
N
A
DO NOT
CONNECT
SENSOR SCREEN SENSOR
AT WALL
KEY CONTROL KEY
COM COM
POWER POWER
FIELD WIRING BY
INSTALLER
TO OUTDOOR UNIT
OPTIONAL OPTIONAL SENSOR WIRING
SENSOR 1 SENSOR 2
R
Base Variation Code: Variation:
Model No:
Description: SRG/V EVAPORATOR WITH EC FAN MOTOR
B LAYOUT CHANGES, ADDED SRV DETAILS N/A MJH 05-11-13 & OPTIONAL ACM WIFI MODULE & POWER SUPPLY
Description PCR By Date This drawing remains the intellectual property of Actron Engineering Drawn: Date: Drawing No: Revision Size:
Rev. MH 02-07-2013
Pty Ltd. Reproduction, modification and/or distribution are prohibited
Approved: Date: WD0903 B A4
A ORIGINAL without written consent. MJH 05-11-2013
ZONE
CONTROL 1
ULTIMA 8Z-VAV MODULE CONNECTIONS & ACCESSORIES ACM POWER SUPPLY AMIB
(SRM MODELS ONLY) IMPORTANT:
ZONE
SENSOR 1
(240VAC - 12VDC 1.3A) DO NOT MOUNT ACM DIRECTLY ON INDOOR UNIT.
AM-ZC DO NOT MOUNT WIFI MODULE
DIRECTLY ON EVAPORATOR UNIT
EMC
ZONE
- FOR OPTIMUM PERFORMANCE OF Wi-Fi SIGNAL
AM-ZS
MOTOR
TO ZONE 2 - 8 - FOR OPTIMUM
MOUNT 1 METRE PERFORMANCE
AWAY (OR GREATER)OF AND EXV
WIFI SIGNAL MOUNT 1 METRE AWAY
NOT ABOVE& THE INDOOR
NOT ABOVE UNIT.
EVAPORATOR F
ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE
8 7 6 5 4 3 2 1 - MOUNT MINIMUM METRE BELOW ROOF LINE.
- MOUNT0.5
MINIMUM 1 METRE BELOW IF
ROOF
ULTIMA MODULE
(8Z-VAV) AC IN DC OUT ADJ
IFRC
240V AMIB TX
MAINS DATA LOG A N -V +V
BLUE
WC
BROWN
BROWN
GREEN / YELLOW
BLUE
BROWN
BRN / WHITE (GREEN)
WIRING DIAGRAM
WIFI
MODULE
BLUE
BROWN
ECM
IF-1 CONTROL
1 EC MODULE ANTENNA
EXV
EXV
INDOOR FAN (IF) INDOOR
P1
E2
COIL IN
INTERNAL AUTO RESET SENSOR
OVERLOAD PROTECTION FERRITE
RST MODE
EC CONTROL
INDOOR
COIL OUT
SENSOR
N
A
ACT
NEUT
EARTH
DATA
COM
KEY
PWR
COM
SCRN
EMC-1
SCREEN
E WIRES
N
A
DO NOT
CONNECT
SENSOR SCREEN SENSOR
AT WALL
KEY CONTROL KEY
COM COM
POWER POWER
FIELD WIRING BY
INSTALLER
TO OUTDOOR UNIT
FIELD WIRING BY INSTALLER -
CABLE MUST BE 2 CORE SHIELDED CABLE WITH SHIELD WIRE
CONNECTED TO THE SCREEN / COMMON TERMINAL
(EITHER 2C 14/0.20 SHIELDED OR 2C TWISTED PAIR 7/0.30 SHIELDED CABLE ACCEPTABLE)
R
Base Variation Code: Variation:
Model No:
Description: SRM
EVAPORATOR WITH EC FAN MOTOR, 8Z-VAV ULTIMA
MODULE & OPTIONAL ACM WIFI MODULE & POWER SUPPLY
Description PCR By Date This drawing remains the intellectual property of Actron Engineering Drawn: Date: Drawing No: Revision Size:
Rev. MH 05-11-2013
Pty Ltd. Reproduction, modification and/or distribution are prohibited
Approved: Date: WD0907 B A4
A ORIGINAL without written consent. MJH 05-11-2013
BLUE
BROWN
AMIB
BROWN
240V
MAINS DATA LOG IFRC
GREEN / YELLOW
ZONE TX
BLUE
ANTENNA
BROWN
UNTIL TERMINAL ON AMIB
B (-)
A
N
OUTDOOR
P1
E2
(+) A
EMC-1
RST MODE
DATA
BLUE
3G LPW WIFI ETH
E ETH AC PWR
BROWN
N
A INDOOR
COIL IN
SENSOR
EC CONTROL
CB-1
10 A
DATA CABLE SCREEN WIRE -
KEEP AS SHORT AS POSSIBLE
ACT
NEUT
EARTH
DATA
COM
KEY
PWR
COM
SCRN
ACT
NEUT
NEUT
LINE 1
SENSOR
SCREEN
WIRES KEY
COM
POWER
R
Base Variation Code: Variation:
Model No:
Description: ERM EVAPORATOR WITH EC FAN MOTOR
& OPTIONAL ACM WIFI MODULE & POWER SUPPLY
Description PCR By Date This drawing remains the intellectual property of Actron Engineering Drawn: Date: Drawing No: Revision Size:
Rev. MH 05-11-2013
Pty Ltd. Reproduction, modification and/or distribution are prohibited
Approved: Date: WD2004 A A4
A ORIGINAL without written consent. MJH 05-11-2013
BLUE
20VA
BROWN
BROWN
IFRC
GREEN / YELLOW
TX
FERRITE
MODULE
(IF FITTED)
WIRING DIAGRAM
B (-)
A
N
OUTDOOR
P1
E2
(+) A
EMC-1
RST MODE
DATA
BLUE
3G LPW WIFI ETH
E ETH AC PWR
BROWN
N
A INDOOR
COIL IN
SENSOR
EC CONTROL
CB-1
10 A
DATA CABLE SCREEN WIRE -
KEEP AS SHORT AS POSSIBLE
ACT
NEUT
EARTH
DATA
COM
KEY
PWR
COM
SCRN
SENSOR
KEY
ACT
NEUT
NEUT
LINE 1
COM
SCREEN POWER
WIRES
DO NOT
CONNECT
SCREEN
AND SENSOR
AT WALL
CONTROL
PCB JUMPER PIN
SENSOR POSITION TABLES
KEY
PCB Model: AMIB-P1VV
COM
POWER Jumper Pin
FIELD WIRING BY A/C Model
Position
INSTALLER
OPTIONAL
SENSOR 2 A ERV2-14AS
FIELD WIRING BY INSTALLER - B ERV3-17AS
CABLE MUST BE 2 CORE 7/0.30 SHIELDED TWISTED PAIR DATA CABLE
WITH SCREEN WIRE CONNECTED TO THE SCREEN TERMINAL ON INDOOR UNIT C ERV4-19AS
& SCREEN FOIL CLAMPED TO P-CLIP ON OUTDOOR UNIT
OPTIONAL D N/A
SENSOR 1
E N/A
R
Base Variation Code: Variation:
Model No:
Description: ERV EVAPORATOR WITH EC FAN MOTOR
& OPTIONAL ACM WIFI MODULE & POWER SUPPLY
Description PCR By Date This drawing remains the intellectual property of Actron Engineering Drawn: Date: Drawing No: Revision Size:
Rev. MH 05-11-2013
Pty Ltd. Reproduction, modification and/or distribution are prohibited
Approved: Date: WD2005 A A4
A ORIGINAL without written consent. MJH 05-11-2013
MAC
Address
Serial
Number