1
Chapter 1 MATERIAL PROPERTIES
2
1.2. Reinforced concrete material
- The reinforced concrete material should have Fc’=28 Mpa with the following
properties.
3
Chapter 2 SECTIONS PARAMETERS
2.1. COLUMNS
- Columns have sections of 40x40 cm
- Shown the columns schedule with corresponding reinforcement
4
2.2. BEAMS
- Beams connecting columns have sections 20x60 & 40x60
5
Chapter 3 LOADS
6
3.2. LIVE LOADS
- The live loads used not exceed 400 kg/m2 for office buildings.
7
3.3. DEAD LOADS (BEAM)
- Super imposed dead loads are taken 0.7/1.25 T/m including wall load .
8
3.4. WIND LOAD
9
WX
WY
10
3.5. EQ LOAD
EQX+ecc
11
EQX-ecc
EQY+ecc
12
EQY-ecc
13
3.6. LOAD COMBINATIONS ULT
- Ultimate main load combination in the model have factor for live =1.7 but
should have factor 1.4 according to SBC.
14
3.7. LOAD COMBINATIONS LATERAL LOADS
15
1.2DL+0.5LL+-EQX-
1.2DL+0.5LL+-EQX+
1.2DL+0.5LL+-EQY+
1.2DL+0.5LL+-EQY-
1.2DL+0.5LL+-WX
1.2DL+0.5LL+-WY
0.9DL+-EQX+
0.9DL+-EQX-
0.9DL+-EQY+
0.9DL+-EQY-
0.9DL+-WX
0.9DL+-WY
16
17
18
19
20
Chapter 4 SECTIONS DESIGN
21
4.2. CHECK BENDING
- Shown the bottom reinforcement map for slab direction x which not need
additional reinforcement at different locations
- Use 6 t 12 MR = 2.81 when Ts = 150 mm
22
- Shown the bottom reinforcement map for slab direction y which not need
additional reinforcement at different locations
- Use 6 t 12 MR = 2.81 when Ts = 150 mm
23
4.3. COLUMNS DESIGN
- Shown the reaction of columns per ultimate combination.
24
No red column design so all column safe
25
26
4.4. BEAM DESIGN
- Shown the plan of GROUND BEAMS
- M33 DIGRAM AT LEVEL GROUND FLOOR / GROUND BEAM
27
DESIGN GROUND BEAM USING ETABS
28
DESIGN BEAM USING ETABS AT LEVEL GROUND FLOOR
29
DESIGN BEAM USING ETABS AT LEVEL FIRST FLOOR
30
4.5. SHARE WALL DESIGN
31
32
4.6. FOUNDATIONS DESIGN
33
LOADS
34
Shown the check results of bearing capacity (DL+LL)
35
Shown the check results of bearing capacity (ENV EQ) MAX
36
- Shown the check results of punching
37
- Shown the bottom bending moment maps for foundations for x-direction
- Shown the bottom reinforcement map for slab direction X which not need
additional reinforcement at different locations
- Use 9 t 16 when Ts = 500 mm MR = 26
38
- Shown the bottom bending moment maps for foundations for y-direction
- Shown the bottom reinforcement map for slab direction Y which not need
additional reinforcement at different locations
- Use 9 t 16 when Ts = 500 mm MR = 26
39
40