Villa Building Calc Note

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 41

i

DESCRIPTION OF THE PROJECT


- The project is located at Saudi Arabia.
- This model/project consists of villa building consisting of 2 stories with
overall height 03.8m

- The structural system consists of reinforced concrete columns


- and share wall.
- The material with type C35mpa (Fc’=28 Mpa) is used through the structure
from the foundations system to columns and also floor system.
- The rebar material with Fy=400 Mpa is used through the structure parts.

1
Chapter 1 MATERIAL PROPERTIES

1.1. Rebar material:

- Rebar material properties should be as follow


Fy=400 Mpa
Fu=600 Mpa
Fye = 440 Mpa
Fue = 660 Mpa

2
1.2. Reinforced concrete material
- The reinforced concrete material should have Fc’=28 Mpa with the following
properties.

3
Chapter 2 SECTIONS PARAMETERS

2.1. COLUMNS
- Columns have sections of 40x40 cm
- Shown the columns schedule with corresponding reinforcement

4
2.2. BEAMS
- Beams connecting columns have sections 20x60 & 40x60

5
Chapter 3 LOADS

3.1. DEAD LOADS (FLOOR)


- Super imposed dead loads are taken 0.15 T/m2 including covering materials .

6
3.2. LIVE LOADS
- The live loads used not exceed 400 kg/m2 for office buildings.

7
3.3. DEAD LOADS (BEAM)
- Super imposed dead loads are taken 0.7/1.25 T/m including wall load .

8
3.4. WIND LOAD

9
WX

WY

10
3.5. EQ LOAD

EQX+ecc

11
EQX-ecc

EQY+ecc

12
EQY-ecc

13
3.6. LOAD COMBINATIONS ULT
- Ultimate main load combination in the model have factor for live =1.7 but
should have factor 1.4 according to SBC.

14
3.7. LOAD COMBINATIONS LATERAL LOADS

15
1.2DL+0.5LL+-EQX-
1.2DL+0.5LL+-EQX+
1.2DL+0.5LL+-EQY+
1.2DL+0.5LL+-EQY-
1.2DL+0.5LL+-WX
1.2DL+0.5LL+-WY
0.9DL+-EQX+
0.9DL+-EQX-
0.9DL+-EQY+
0.9DL+-EQY-
0.9DL+-WX
0.9DL+-WY

16
17
18
19
20
Chapter 4 SECTIONS DESIGN

4.1. CHECK DEFLECTION


- Shown the deflection map which is safe
- Max deff = 9.43 mm > allowable deff 430/240= 17.9mm

21
4.2. CHECK BENDING
- Shown the bottom reinforcement map for slab direction x which not need
additional reinforcement at different locations
- Use 6 t 12 MR = 2.81 when Ts = 150 mm

22
- Shown the bottom reinforcement map for slab direction y which not need
additional reinforcement at different locations
- Use 6 t 12 MR = 2.81 when Ts = 150 mm

23
4.3. COLUMNS DESIGN
- Shown the reaction of columns per ultimate combination.

24
No red column design so all column safe

25
26
4.4. BEAM DESIGN
- Shown the plan of GROUND BEAMS
- M33 DIGRAM AT LEVEL GROUND FLOOR / GROUND BEAM

27
DESIGN GROUND BEAM USING ETABS

28
DESIGN BEAM USING ETABS AT LEVEL GROUND FLOOR

29
DESIGN BEAM USING ETABS AT LEVEL FIRST FLOOR

30
4.5. SHARE WALL DESIGN

PIER D/C RATIO

31
32
4.6. FOUNDATIONS DESIGN

SHOW THE PLAN OF FOUNDATIONS

33
LOADS

34
Shown the check results of bearing capacity (DL+LL)

35
Shown the check results of bearing capacity (ENV EQ) MAX

Shown the check results of bearing capacity (ENV EQ) MIN

36
- Shown the check results of punching

37
- Shown the bottom bending moment maps for foundations for x-direction

- Shown the bottom reinforcement map for slab direction X which not need
additional reinforcement at different locations
- Use 9 t 16 when Ts = 500 mm MR = 26

38
- Shown the bottom bending moment maps for foundations for y-direction

- Shown the bottom reinforcement map for slab direction Y which not need
additional reinforcement at different locations
- Use 9 t 16 when Ts = 500 mm MR = 26

39