Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 10

Design and Analysis of Square Fo

INPUT
COLUMN DIMENSIO
DEAD LOAD
LIVE LOAD
DEPTH OF FOOTING BAS
SOIL ALLOWABLE BEARING PRESSURE (qa
UNIT WT OF SOIL ABOVE FOOTING
UNIT WT OF CONCRET
DIAMETER OF STEEL BAR
f'c
fy
CLEAR COVER
THE DEPTH PERCENTAGE IN TERMS OF LENGTH

DESIGN AND ANALYSIS


STEP 1: APPROXIMATE THE TOTAL DEPTH OF FOOTING
AREA:
L:
d:
TOTAL DEPTH,D:

Actual Depth (d):

STEP 2: SOLVE FOR EFFECTIVE SOIL BEARING PRESSURE(qe)

STEP 3: SOLVE FOR THE ACTUAL REQUIRED AREA


A:
L:
ultimate bearing pressure (qu):
STPE 4:CHECK THE BEAM SHEAR

Design Shear Strenght (Vc):

x:
Ultimate Shearing Stress (Vu):

STEP 5:CHECK FOR PUNCHING SHEAR


y=

Design Shear Strenght (Vc)=

Ultimate Shearing Stress (Vu)=

STEP 6:SOLVE FOR THE REQUIRED STEEL BARS:


Z=
As =
No. of Bar =
Clear Spacing =
Moment Capacity of the Beam
As

INTERNAL MOMENT,Mui
EXTERNAL MOMET,Mue

STEP 7:CHECK FOR DEVELOPMENT LENGTH:


DEVELOPMEN LENGTH,ld =
PROVIDED DEVELOPMENT LENGTH =
GROUP MEMBERS:

1 MERCADER, MYRX F.
2 MOLOBOCCO, ACE ROMYR
3 SILAGAN, JONATHAN L.
4 SUMAYANG, MIKE O.

s of Square Footing
VALUE UNIT
COLUMN DIMENSION 350 mm
DEAD LOAD: 1080 kN
LIVE LOAD: 500 kN
DEPTH OF FOOTING BASE: 1.5 m
ABLE BEARING PRESSURE (qa): 240 kPa
WT OF SOIL ABOVE FOOTING: 15.74 kN/m^3
UNIT WT OF CONCRETE: 23.5 kN/m^3
DIAMETER OF STEEL BARS: 20 mm
f'c : 21 MPa
fy : 415 MPa
CLEAR COVER: 75 mm
NTAGE IN TERMS OF LENGTH: 20%

AND ANALYSIS
OF FOOTING
6.58333333333333 m^2
2.56580071972344 m^2
0.513160143944688 m^2
598.160143944688 mm say 600 mm

515 mm

G PRESSURE(qe)
height of soil (hs): 0.9 m
height of concrete (hc): 0.6 m
qe: 211.734 kPa

7.46219312911483 mm^2
2.73170150805589 m say 2.74 m
279.183760456071 kPa

808309.070394023 N or 808.30907039 kN

0.68 m
520.175182481752 kN or 520175.18248 N

SAFE

0.865 m

6124268.72313136 N or 6124.2687231 kN

1887.10773083276 kN or 1887107.7308 N
SAFE

1.195 m
4760.33734939759 mm^2 Raw minimum (Pmin) =
15.1603100299286 pcs say 16 pcs
151.333333333333 mm
5024 a= 42.6293729171

926382718.18929 N-mm or 926.38271819 kN-mm


68.2741879562044 kN-m or 68274187.956 N-mm

SAFE

65.2035056025145 mm
1120 mm

OKAY
E ROMYR

MODIFICATION FACTORS FOR DEVELOPMENT OF


DEFORMED BARS AND DEFORMED WIRED IN TENSION
BASED ON NSCP 2015
MODIFICATION FACTOR Condition Value of Factor

Lighweight Normal -weight concrete 1


Epoxy Uncoated or zinc coated 1
(galvanized factor)
Casting position Other 1
0.003373