Professional Documents
Culture Documents
Proj 1 Design of Square Footing Procedure
Proj 1 Design of Square Footing Procedure
INPUT
COLUMN DIMENSIO
DEAD LOAD
LIVE LOAD
DEPTH OF FOOTING BAS
SOIL ALLOWABLE BEARING PRESSURE (qa
UNIT WT OF SOIL ABOVE FOOTING
UNIT WT OF CONCRET
DIAMETER OF STEEL BAR
f'c
fy
CLEAR COVER
THE DEPTH PERCENTAGE IN TERMS OF LENGTH
x:
Ultimate Shearing Stress (Vu):
INTERNAL MOMENT,Mui
EXTERNAL MOMET,Mue
1 MERCADER, MYRX F.
2 MOLOBOCCO, ACE ROMYR
3 SILAGAN, JONATHAN L.
4 SUMAYANG, MIKE O.
s of Square Footing
VALUE UNIT
COLUMN DIMENSION 350 mm
DEAD LOAD: 1080 kN
LIVE LOAD: 500 kN
DEPTH OF FOOTING BASE: 1.5 m
ABLE BEARING PRESSURE (qa): 240 kPa
WT OF SOIL ABOVE FOOTING: 15.74 kN/m^3
UNIT WT OF CONCRETE: 23.5 kN/m^3
DIAMETER OF STEEL BARS: 20 mm
f'c : 21 MPa
fy : 415 MPa
CLEAR COVER: 75 mm
NTAGE IN TERMS OF LENGTH: 20%
AND ANALYSIS
OF FOOTING
6.58333333333333 m^2
2.56580071972344 m^2
0.513160143944688 m^2
598.160143944688 mm say 600 mm
515 mm
G PRESSURE(qe)
height of soil (hs): 0.9 m
height of concrete (hc): 0.6 m
qe: 211.734 kPa
7.46219312911483 mm^2
2.73170150805589 m say 2.74 m
279.183760456071 kPa
808309.070394023 N or 808.30907039 kN
0.68 m
520.175182481752 kN or 520175.18248 N
SAFE
0.865 m
6124268.72313136 N or 6124.2687231 kN
1887.10773083276 kN or 1887107.7308 N
SAFE
1.195 m
4760.33734939759 mm^2 Raw minimum (Pmin) =
15.1603100299286 pcs say 16 pcs
151.333333333333 mm
5024 a= 42.6293729171
SAFE
65.2035056025145 mm
1120 mm
OKAY
E ROMYR