Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 2

ARKIFLOOR EHG

Two-component, glass-flakes reinforced floor coating system

PRODUCT DESCRIPTION TECHNICAL PROPERTIES

Arkifloor EHG is a epoxy flooring system with superb EHG EHG


DESCRIPTION
chemical resistance and good adhesive properties (Standard) (Non-slip)
designed specially for environment demanded for high Adhesion Strength
specifications of aesthetic and corrosion control. 2.5 N/mm2 2.5 N/mm2
JIS K 5400 8.7
Arkifloor EHG Standard gives a smooth, uniform and
hard surface preventing dust accumulation and able to
Abrasion Resistance
take medium to heavy-duty vehicular movement. When 30 mg 26 mg
it is applied in non-slip form, excellent anti-skid JIS K 5400 8.9 (1000 rounds)
performance can be achieved.
Anti-skid Coefficient 70 (Dry) 78 (Dry)
Arkifloor EHG is suitable to be applied on old or new Portable Skid Test 36 (wet) 55 (wet)
concrete and cementitious floor of industrial and Freezing and Melting Test
commercial laboratories, food factories, production (After 100 cycles of each
factories, warehouses, workshops, carpark floors, power No change No change
cycle = -20 oC x 16 hrs + 20
plants, wafer plants, and chemical storage rooms, etc. o
C x 8 hrs)
Arkifloor EHG comes in a wide range of colors for your
flooring needs. For standard colors, please refer to our Hardness 2H 2H
Color Chart. Special color requests are available on
request. Heat and Cool Test
JIS A 6909 5.9.1 (100 cycles
of each cycle = immersion in No change
FEATURES water x 18 hrs, – 20oC x 3
hrs, + 50oC x 3 hrs)
 Excellent resistance to a wide range of chemicals
and oil spills Tensile Strength &
 Dust proof, reduces floor maintenance Elongation At Break
14.07 N/mm2
 Strong and durable with seamless finish ASTM D 882:95a
 Excellent impact and abrasion resistance for Impact Resistance
medium to heavy-duty vehicular movement
JIS K 5400 8.3.2 Dupont test : No peeling / cracks
 Retards the growth of bacteria and mould
Dropping 500g of steel ball
 Non-slip finish available
from 50 cm height
Odor Low
PHYSICAL PROPERTIES
Toxicity Physically safe
Color Wide range
Finish Gloss
SURFACE PREPARATION
Film Thickness Wet Film : 350 microns
Concrete Substrate
Dry Film : 260 microns
Concrete surfaces should be well cured and free from
Flash Point 20oC dirt, dust, oil, grease and foreign matters. Any unsound
substrates, cracks, and pot-holes should be made good
Loading Capacity Surface Dry : 4 hrs
with the appropriate SKK filler product.
(30oC) Fully Cured : 7 days
Pot Life (30oC) Approx. 60 mins Concrete is highly susceptible to uprising moisture,
which can decrease the effectiveness of any coating
Volume Solid 75 + 3% system. Installation of a water-proofing membranes
mandatory to prevent glitches in the dynamics of any
Shelf Life coating system. Smooth concrete surfaces may have to
Up to 6 mths
(in sealed container) be chemically cleaned or mechanically scarified to
Specific Gravity Approx. 1.22 + 0.10 provide bonding keys before the coating can be laid.
Etching neutralizes the alkaline surface and provides a
better bond. It also helps remove salt deposits or
laitance that can occur on concrete surfaces.

Masonry and Mortar Substrate

1/2
ARKIFLOOR EHG
Two-component, glass-flakes reinforced floor coating system

Masonry surfaces may peel due to efflorescence, where CHEMICAL RESISTANCE


soluble salts are present. It is therefore essential to
treat the surfaces free from dirt, dust, oil, grease and Resistance to splash or
Slight
foreign matters. Environmental determinants like spillage of industrial No
Degradation/
humidity can also cause structural or superficial chemicals at ambient Degradation
Discoloration
cracks with mortar. temperatures
Restoration work should be carried out to amend these INORGANIC ACIDS
problems prior to the application of paint. If 50% Sulfuric Acid ♦
efflorescence is also evident, it must be removed before 37% Hydrochloric Acid ♦
repainting. Remove all flaking or chalking paint from the 50% Nitric Acid ♦
damaged area by wire brushing or sandblasting. If
50% Phosphoric Acid ♦
surface is very porous, apply SK Floor Filler, an epoxy
resin-based cementitious conditioner to mend the ORGANIC ACIDS
surface. 10% Lactic Acid ♦
5% Formic Acid ♦
APPLICATION PROCEDURES 10% Acetic Acid ♦
ALKALINE
 M
IXING 30% Calcium Chloride ♦
20% Potassium Chloride ♦
Mixing Ratio (by weight ratio) Saturated Calcium ♦
Base Hardener Hydroxide
25% Ammonia ♦
100 22.3 50% Sodium Hydroxide ♦
Firstly, mix the entire content of the hardener with the 10% Sodium Hypochlorite ♦
base thoroughly in a container. Subsequently, dilute the ORGANIC SOLVENT
mixture with EH Thinner as needed. Methyl Alcohol ♦
Toluene ♦
APPLICATION Petrol ♦
Ensure that substrate surface is cleaned prior to AQUEOUS SOLUTION
priming. Apply one coat of SK Arkiprimer and two Water ♦
coats of Arkifloor EHG over the substrate by roller or Sugar Solution ♦
brush. After allowing adequate curing, the surface 10% Sodium Chloride ♦
should be inspected for runs, foreign matter and under
cured areas. Do not apply Arkifloor EHG at CLEANING
temperature below 10oC.
Tools must be cleaned immediately after use with SKK
Coverage Thinner.
Per Coat 110 - 130 m2 (or 0.19Ltr/ m2)
Overcoating Interval 8 hrs, max 3 days SAFETY PRECAUTIONS
No. of Coats 2 This product contains volatile and inflammable solvents
and must not be used near flame or welding operations.
Avoid contact with skin or eye. Any skin or eye
PACKING STYLE contamination should be washed immediately with
plenty of water and seek medical treatment. If
Arkifloor EHS (22 Ltr/set) swallowed, do not induce vomiting. Contact a physician
Arkifloor EHS Base 17 Ltr can immediately.
Arkifloor EHS Hardener 5 Ltr can

MATERIAL HANDLING

Always wear the appropriate safety goggles, breathing


protection, clothing and gloves during the handling of
epoxy resins and hardeners. Work with adequate
The technical information given herein is of a general nature
ventilation during application. Any sources of ignition and correct to the best of our knowledge based on laboratory
should be eliminated and only use equipment tests and professional experiences. It shall not to be construed
incorporated with explosion protection. Do not smoke. as implying any guarantee of performance. Due to
Store all materials in a cool, well-ventilated and dry unforeseeable conditions and constraints, we will not assume
liability for the unsuccessful use of this product. We reserve the
place, away from direct sunlight. Properly dispose all right to alter or modify any data given without prior notice.
used containers and excess materials in accordance to When in doubt, please consult our technical department for
the local governing safety rules and regulations. further information.

2/2

You might also like