Content

© 20 FRIMEC-INTERNATIONAL. All rights reserved.


Product Nomenclature

Air-Cooled Ducted Indoor Unit

Air-Cooled Ducted Outdoor Unit


Features

Wide Range of
Products

Multi Circuit Design

Low Noise

Intelligent Control
(Optional)

Simple Installation
Engineering Specification
General Data - Air-Cooled Split Ducted (R22)
General Data - Air-Cooled Split Ducted (R22)
General Data - Air-Cooled Split Ducted (R407C)
General Data - Air-Cooled Split Ducted (R407C)
Operating Range

Cooling
System
Model : FASN080/100/125/150

Indoor Outdoor
Indoor Outdoor 1 Outdoor 2
Model : FASN350/450

Outdoor Heat Exchanger Compressor

High Pressure
Switch

Low Pressure
Switch
Outdoor 3

Outdoor Heat Exchanger Compressor


High Pressure
Switch

Low Pressure
Switch
Outdoor 2

Outdoor Heat Exchanger Compressor


High Pressure
Switch

Low Pressure
Switch
Outdoor 1

TXV

TXV

TXV Indoor Heat Exchanger

Indoor
Outdoor 1 Outdoor 2 Outdoor 3 Outdoor 4

Indoor
Model : FASN400/500/600
Controller Features And Algorithm (Optional)

Single stage operation instruction

Use of buttons on LED wall pad controller

SENSOR

ON/OFF

AUTO COOL
HIGH DRY
TEMP
MED FAN HEAT
MODE
LOW FAN

TIMER SLEEP

Operation Instruction
Fault Error code Remarks
Controller Features And Algorithm (Optional)

Multi-stage operation instructions

Wall Pad

10PM
1 2
1 2 3
4 5 6
Wall pad guide:

<MODE>

<CLOCK>
<TIME+/->
<CLOCK>

<DAY>

<TIMER> <TIMER>

<TIMER>
<TIME+/->
<CANCEL>
<TIMER>

<TIME+/->

<TIME+/->
<CANCEL>
<TIMER>
<CANCEL>
<TIMER>
<DAY>

<CANCEL>

<TiO2> <TiO2>
<TiO2>

Temperature Browsing

<DISPLAY>
<SELECT >

<DISPLAY>
<SET>
<SELECT >
<RESET>
80 800
Input Power (W)

60 600
Pt (Pa)

40 400

20 200

0 0
5,000 8,000 11,000 14,000
BLOWER COIL

BLOWER

COIL
BLOWER

COIL
Wiring Diagram
Installation

Warning:

Indoor Unit Installation

Minimum 800mm
Condensate drain pipe installation:

Note:
A U-bend must be installed along the
drain pipe. The recommendation is as
following:
100mm<h<150mm and x>h/2

Air Ducting Installation


Outdoor Unit Installation

Installation Clearance

Min 1500mm

Min 700mm Min 1200mm

Min 500mm

Min 500mm
Min 700mm
Refrigerant Piping

Maximum Length Maximum Elevation Maximum


Model
(m) (m) Bends

Vacuuming and Refrigerant Charging

Vacuuming

Charging

Additional Charging

Outdoor Model
Add. Charge, g/m

Attention:
Servicing and Maintenance

Indoor Unit
Air Filter

Motor

Heat Exchanger

Drain Pipe

Outdoor Unit

Warning!

Do not use oxygen, acetylene, poisonous gas or other gas that will cause
explosion under high temperatures and pressure for leak checking. Instead,
use nitrogen or R22 for air leakage test.