7 - Annexes
Annex 1 - Electrical connection layout
Annex 2 - Electronic layout
Annex 3 - Hydropneumatic layout
Annex 4 - Exploded drawings
Annex 5 - Exploded drawings
Annex 6 - Exploded drawings
Annex 7 - Exploded drawings
m
0c
=5
B
cm
50
A=
35cm
mínimo = 65cm
30cm 25cm
para equipo
Obs: It is important to emphasize that the principal tools were listed above for the dental
unit installation and that these tools do not go with the equipment.
If the customer opted for installing the equipment without the aid of the Technician, we
advise the acquisition of the listed items or perform a “loan”.
Step 1 Step 2
Remove the packing staples (indicated by the Remove the carton box, by pulling it upwards. It
arrows), using a screwdriver or any similar tool. is advisable that this operation be executed by 2
people.
* The filling in this figure is only illustrative; it is not part of this packing.
K4 K5 K6
K1 K2 K3
3 7
4
6
8 9
5
Step 6 (Equipment): Cut the arm setting Step 7: Remove The packing Equipment Step 8 (Cask Packing): Remove the cask
clamp. and place it in the floor carefully so as not packing and place it on the floor carefully
to damage it. so as not to damage it.
Step 9 (Chair Arm): Loosen the arm, using Step 10 (Motor Cover): Remove the motor Step 11 (Unit): Loosen the unit, using a
a 1/2” open or ring wrench, place it on the cover and place it on the floor carefully so 7/16” open or ring wrench.
floor carefully so as not to damage it. as not to damage it.
Step 12 (Unit): Remove the unit and place Step 13 (Equipment): Remove the support Step 14 (Equipment): Loosen the
it on the floor carefully so as not to damage cover, in order to facilitate the next equipment support, using a 1/2” barrel
it. operation. screwdriver, place it on the floor carefully
so as not to damage it.
Step 18: Position the joint hole with the Step 19: Fix the joint axle with the ring Step 20: Loosen the seat complement,
coupling hole on the chair’s headrest and (according to the photo). using a 1/2” open or ring wrench.
place the joint axle.
Step 21: Position the seat complement, Step 22: Set the seat complement, using a Step 23: Loosen the chair from the pallet,
according to the photo. 1/2” open or ring wrench. using a 1/2” open or ring wrench.
(2 screws and 2 nuts)
Step 24: Position the mat on the floor, Step 25: Remove the chair from the pallet,
observing the dental unit location inside and place it on top of the mat. It is
the room. advisable that this operation be executed
by 2 people.
!
AMBIDEXTROUS DENTAL UNIT: The mounting of the auxiliary unit
and equipment support should be on the right side of the chair for
left-handed dentist.
Step 26: Remove the rack cover using a Step 27: Position the unit on the seat plate Step 28: Loosen the unit body end support,
Philips screwdriver and a 5/16” fixed and set it using a 1/2” open or ring wrench, using a Philips screwdriver.
wrench. and the items K1 of the kit indicated on
page 7.
Step 29: Position the unit body point Step 30: Pass the unit hoses and cable Step 31: Mount the basin, the cup holder
support and set it using the Philips through the upper rack hole and, leaving grill; the basin grill and basin grill cover.
screwdriver. them as indicated on the photo.
Step 32: Position the equipment support Step 33: Position PET support on the Step 34: Mount the support cover, by
on the seat plate and set it using a 1/2” equipment support and set it using a 5/16” positioning it as indicated in the photo.
open or ring wrench and items K2 of the kit barrel screwdriver.
indicated on page 7.
Step 35: Mount the plug in the “smaller” Step 36: Get the equipment mount it on Step 37: Fit correctly the arm joint parts.
tube of the equipment (please refer to the support, passing the hoses through the
position according to the photo), being plug, fit the tube into the plug, being
careful such that the lateral split of the careful such that the tube pin may fit in the
plug fits in the tube pin. plug split.
Step 38: Pass the equipment hoses above Step 39: Then pass the equipment hoses Step 40: Cut the arm protection net using a
the beams of the equipment support. through the clamp located below the seat pair of scissors.
plate and tighten the clamp, leaving
slightly free.
Step 41: Unpack the equipment head items Step 42: Pass the equipment and unit Step 43: Mount the rack cover using a
and position them on the end support, hoses and cables through the elevation Philips screwdriver and a 5/16” fixed open
according to the photo. lever. Perform an evaluation in order to wrench, operation contrary to Step 25.
Note: The high rotation instruments and micro motor assure that the hoses are not bent.
are sold separately.
Step 44: Mount the plug in the “larger” Step 45: Get the reflector mount it on the Step 46: Fit correctly the arm joint parts.
reflector tube (please refer to position support, passing the wires through the Cut the reflector arm safety clamp.
according to Step 34), being careful such plug, fits the tube in the plug, being careful
that the lateral split of the plug fits in the such that the pint (please refer to inside
tube pin. the tube) fits in the plug split.
Step 47: Pass the wires of the reflector Step 48: Cut the arm protection net using a
above the equipment support beams. pair of scissors.
6.7 - Setting the arm on the chair and placing rack cover finishing
Step 49: Position the arm on the seat plate Step 50: Fit the finishing rubber on the
and set it using two 1/2” Sext. screws rack cover.
removed during the execution of Step 9
and a 1/2” fixed open or ring wrench.
D
G
H
H
H
B
J
Step 51: Separate the hoses that are Step 52: Connect hose H in nipple H, Step 53: Connect hose G to the upper
identified with letters, according to the connect hose B in nipple B, connect hose J nipple and the other point of hose H in the
above figure. to nipple J. Connect hose D to the pedal PET deposit support. Then tighten the
hose nipple. bottle in the support.
2 8
F2
1
1
77
7 F3
F1 Air
Sewer
Step 54: Separate the wires and also hoses Step 55: Connect hose 1 to nipple 1,
identified with numbers and letters, connect hose 2 to nipple 2, connect hose 8
according to the above figure. to nipple 8.
77
7
Water
Air
F1
F2
Sewer
Water
F3
Step 56: Connect hose 7 to nipple 7, Step 57: Tighten the sewer Box and the
connect hose 77 to nipple 77, connect wire Black Water Nipple in the already defined
F1 to connector F1, connect wire F2 to places, then connect blue hose WATER to
connector F2 and wire F3 to connector F3. black nipple WATER setting it with clamp
K5 indicated in the kit of page 7, connect
hose SEWER to the SEWER input.
Step 59: Remove the packing staples (indicated by the Step 60: Remove the items inside the packing in accordance
arrows), by using a screwdriver or any similar tool. with the order of mounting.
Step 61: Position the Cover above the Step 62: With the parts in position, Step 63: Mount the headrest on he
Filling, aligning the holes. Please refer to perform the setting using 4 nuts and 4 headrest structure. Please see above photo.
the above photo. Philips screws and a Philips screwdriver.
Note: The nuts and the screws are in the packing Kit.
Step 64: There are 6 points with Velcro in Step 65: Remove the protective film of the Step 66: Clean well the head rest plate.
the headrest filling and 6 points with Velcro, in two parts. Position the filling above the headrest
Velcro in the head rest plate. plate, being careful so that it is centralized
and perform pressure, as indicated, so that
there is adherence of one part to the other.
Step 67: Position the seat filling above the Step 68: Perform the setting of the rear Step 69: Perform the setting of the front
seat plate, being careful so that the setting part using two 5/16” nuts and a 5/16” part using two 5/16” nuts and a 5/16”
screws fit in the holes (front and rear). fixed open wrench or barrel screwdriver. fixed open wrench or barrel screwdriver