Room 1 / Summary
Height of Room: 9.000 ft, Light loss factor: 0.80 Values in Lux, Scale 1:47
Workplane:
Height: 2.493 ft
Grid: 64 x 64 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.607, Ceiling / Working Plane: 0.443.
Luminaire Parts List
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
PHILIPS RC132V G4 W30L120 PSU 1
1 4 3600 3600 29.0
xLED36S/840 OC (1.000)
PHILIPS WL131V PSR 1 xLED20S/830 D350
2 1 2000 2000 25.0
(1.000)
PHILIPS WL131V PSR 1 xLED20S/840 D350
3 1 2000 2000 25.0
(1.000)
Total: 18400 Total: 18400 166.0
Specific connected load: 0.77 W/sq ft = 0.11 W/sq ft/100 lx (Ground area: 215.99 sq ft)
Page 4
Project 1
07 / 17 / 2023
Operator
Telephone
Fax
e-Mail
Page 5
Project 1
07 / 17 / 2023
Operator
Telephone
Fax
e-Mail
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²]
direct indirect total
Workplane 386 308 693 / /
Floor 291 298 590 20 38
Ceiling 54 254 308 80 78
Wall 1 174 249 423 90 121
Wall 2 125 245 370 90 106
Wall 3 139 260 399 80 102
Wall 4 140 262 402 90 115
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.607, Ceiling / Working Plane: 0.443.
Specific connected load: 0.77 W/sq ft = 0.11 W/sq ft/100 lx (Ground area: 215.99 sq ft)
Page 6